HomeMy WebLinkAboutCARRIAGE HOUSE APARTMENTS - PDP - PDP120035 - REPORTS - RECOMMENDATION/REPORTCarriage House Apartments, #f 120035 March 21, 2 Planning & Zoning Board
6. Findings of Fact/Conclusions:
In reviewing the request for Carriage House Apartments PDP, Staff makes the
following findings of fact:
A. Multi -family dwelling units are a permitted use in the N-C-B, Neighborhood
Conservation Buffer District.
B. The Project Development Plan complies with the applicable provisions of
Article Four, District Standards.
C. The Project Development Plan complies with the applicable General
Development Standards of Article Three.
RECOMMENDATION:
Staff recommends approval of Carriage House Apartments, Project Development Plan
#PDP120035.
ATTACHMENTS:
1. Site Plan (architectural elevations included)
2. Landscape Plan
3. Tree Mitigation Plan
4. Plat
5. Planning Objectives
6. Traffic Study
7. Minutes from October 10, 2012 Landmark Preservation Commission.
8. Notes from the October 29, 2012 Neighborhood Meeting
9. Citizen Comments
Page 13
Carriage House Apartments DP120035 March 2 )13 Planning & Zoning Board
abutting single-family home to the south at 1321 South Shields Street.
This standard is not applicable because the N-C-B District standards
contained in Article 4 would govern the rear/side setback due to Section
3.1.2. This Section states that, "In the event of a conflict between a
standard or requirement contained in Article 3 and Article 4, the standard
in Article 4 shall prevail." The N-C-B District requires a 15 foot setback in
this instance. The project provides a 15 foot 5 inch setback and meets the
requirements.
(2) 3.8.30(F)(2)— Variation Among Repeated Buildings
These standards require developments containing between 3 — 5 buildings
to provide two different building designs with two different muted, color
palettes. The project meets this standard by the two different "green" and
"white" designs. The green buildings contain 13 and 14 units while the
while buildings are smaller and contain 10 units. The green buildings are
a total of 8,092 square feet and the white buildings are 7,699 square feet.
(3) 3.8.30(F)(4)— Entrances
The project provides covered entrances that are visible from Springfield
Drive and South Shields Street, meeting the standard.
(4) 3.8.30(F)(5)— Roofs
The two building designs employ traditional forms such as hip and gable
roofs with articulation and accent brackets. Both building designs have low
pitches, reflecting the Craftsman style. The secondary roofs transition over
the second story balconies. The PDP meets the standard.
(5) 3.8.30(F)(5)— Facades and Walls
Each multifamily building is articulated with projections and covered
entries, assisting with dividing the fagade into human -scaled proportions
similar to adjacent single family dwellings. There are no blank walls. The
PDP complies with the standards.
4. Compliance with Applicable Article Two, Administration:
A. Section 2.2.2 — Neighborhood Meetings
A neighborhood meeting was held on October 29, 2012. A summary of this
meeting is attached. Discussion centered around the impact on the adjacent
neighborhoods to the west and south, and the number of parking spaces.
Page 12
Carriage House Apartments, #F 120035 March 21, 2 Planning & Zoning Board
City's levels of service standards for both pedestrians and bicycles are
met.
Overall, the Traffic Study concludes that with this project, the future level
of service at the Springfield Drive and Shields Street intersection will be
acceptable.
Q. Section 3.6.5 — Transit Facilities Standards
This standard requires new developments to accommodate existing and
planned transit routes by providing transit stops and associated facilities.
The site is served by Transfort Route 19 on Shields Street with both north
and south service. Transfort Route 3 provides northbound service on
Shields Street. Both Route 19 and 3 serve the CSU Transit Center. Route
19 runs every 60 minutes year-round and every 30 minutes at AM and PM
peak periods during the school year.
The PDP provides a Transfort bus stop concrete pad along South Shields
Street. The project meets the standards of this Section.
R. Section 3.8.30 — Multi -family Dwelling Development Standards
Multi -family developments located in the TOD Overlay Zone are specifically
exempt from the mix of housing unit types requirement, access to park, central
feature or gathering place requirements and the building requirements. The multi-
family buildings are not exempt from meeting the block or design standards.
S. Section 3.8.30(D) — Block Requirements
The block requirements mandate multi -family developments to feature a series of
blocks, made up of public streets, private streets or street -like private drives, no
more than 7 acres in size. The PDP is only 1 block with buildings fronting along
Springfield Drive and South Shields Street. The site is 1.48 acres, satisfying the
requirements.
Section 3.8.30(F) — Design Standards for Multi -Family Dwellings
This Section of the LUC addresses architecture and site design as it relates to
multi -family developments. Moreover, this Section is intended to promote variety
in multi -family buildings and enhance visual interest, reinforcing architectural
elements.
(1) 3.8.30(F)(1) — Orientation and Setbacks
This standard states that setbacks from the property line of abutting
property containing single and two-family dwellings is 25 feet. There is an
Page 11
Carriage House Apartments IDP120035 March Z D13 Planning & Zoning Board
This standard requires that compatibility be achieved by consideration of
scale, form, materials, color, buffer yard and operational standards. Staff
has considered the cumulative effects of the issues related to
neighborhood compatibility and pertinent issues related to scale, form,
materials and color have been addressed. As previously stated, it is
important to note that there is no one single standard in the Land Use
Code that would be equivalent to a compatibility test. In fact, the definition
of "Compatibility" (above) specifically states that it "...does not mean the
same as." Rather, the Code further breaks the issues down. The PDP has
been evaluated by these standards and the PDP is found to be in
compliance.
O. Section 3.5.2(C) — Relationship of Dwellings to Streets and Parking
This standard requires that every front fagade with a primary entrance
shall face the public street (smaller than an arterial) and be within 200 feet
of a connecting walkway, to the extent reasonably feasible. Buildings 1 — 4
face Springfield Drive and feature porches with entrances and connecting
walkways out to the public sidewalk along Springfield Drive. In the case of
Building 5, the building has a connecting walkway to the sidewalk along
Shields Street. The PDP meets the standards.
P. Section 3.6.4 — Transportation Level of Service Requirements
The Transportation Impact Study (TIS) memorandum was provided as
part of this Project Development Plan. Since the site is close to campus,
the standard practice of a 25 percent trip reduction was taken into account
for utilization of multi -modal transportation options.
The Shields Street and Springfield Drive intersection will operate
acceptably based on adopted level of service standards. The TIS shows
that the existing single family homes on site generate 28 daily trip ends
and the trip generation for Carriage House Apartments is calculated at 204
daily trip ends. While the traffic on Springfield Drive will increase to the
west of the site, it is still commensurate with that expected on a local
street. Nevertheless, the project meets the City's level of service
standards.
In addition, the PDP is in an area in which a pedestrian and bicycle Level
of Service evaluation is required. In terms of pedestrian connectivity and
level of service, there are existing crosswalks at the Prospect Road and
Shields Street and Elizabeth Street and Shields Street signalized
intersections. Additionally, there is a striped crosswalk (across Shields
Street) with a pedestrian signal at Lake Street. The TIS shows that the
Page 10
Carriage House Apartments, #F. 120035 March 21, 2. Planning & Zoning Board
standard of quality. Moreover, the compatibility standards of this section
require that the characteristics of the proposed buildings and uses are
compatible when considered within the larger context of the surrounding
area. The Land Use Code offers the following definition of the term
"compatibility":
Compatibility shall mean the characteristics of different uses or
activities or design which allow them to be located near or adjacent to
each other in harmony. Some elements affecting compatibility include
height, scale, mass and bulk of structures. Other characteristics
include pedestrian or vehicular traffic, circulation, access and parking
impacts. Other important characteristics that affect compatibility are
landscaping, lighting, noise, odor and architecture. Compatibility does
not mean "the same as. " Rather, compatibility refers to the sensitivity
of development proposals in maintaining the .character of existing
development.
The definition of compatibility is unique as no single element of the
compatibility definition is essentially equivalent to a compatibility litmus
test; rather it is a contextually driven notion and is derived based on
circumstances on a case -by -case basis.
The proposed buildings are three -stories (40 feet tall) in height and are
compatible with single family homes on Springfield Drive to the east and
the two-story (28 feet tall) single-family homes to the south on Bennett
Road. The height of the project, in tandem with its location on an arterial,
provide an appropriate and compatible transition from the high traffic and
commercial east of Shields Street to the adjacent single-family
neighborhoods to the west. Instead of one large, massive multi -family
structure, the PDP responds to the existing residential character to the
north, south and west, by breaking up the project into five smaller
buildings that are articulated with front porches assisting with the project
blending in with the existing streetscape composition.
The architectural character borrows from the Craftsman Bungalow
vernacular of the area and sets an enhanced standard of quality for future
projects. The primary building material is horizontal lap siding with the
inclusion of stone and brick at the base. The buildings are appropriately
articulated, further breaking up each building's mass, as they read more
like large single-family homes. Detailing features such as hip and gable
roofs, accented window trim and timber brackets enhance the architectural
character and reinforce the compatibility of the project with the area.
N. Section 3.5.1(H) — Land Use Transition
Page 9
Carriage House Apartments #PDP120035 March 272013 Planning & Zoning Board
Willow
214
24
21-bd
22 2-bd
35 spaces
42 spaces
Street Lofts
Willow
units
Total: 46
Proposed:
1305-
57
29 1-bd
16 2-bd
Carriage
1319 S.
units
12 3-bd
58 spaces
96 spaces
House Apts.
Shields
Total: 97
As illustrated by the table above, the data would suggest that the market
response is to provide one parking space per dwelling unit in the TOD.
Section 3.2.2(K)(5) — Handicap Parking
The code requires 3 handicap parking spaces for projects that provide 51-
75 total parking spaces. The Carriage House Apartments PDP meets the
required three handicapped accessible spaces, including one van
accessible space.
J. Section 3.2.4 — Site Lighting
The Applicant submitted a photometric plan and the proposed site lighting
complies with the requirements set forth in this section of the Land Use
Code. Site lighting will feature down -directional, fully shielded, cut-off
fixtures that are consistent in character with the craftsman bungalow style
architecture proposed. Public street lighting has been factored into the
lighting plan to avoid redundancy.
K. Section 3.2.5 — Trash and Recycling Enclosures
The proposed trash collection/recycling enclosure satisfies the Land Use
Code requirements. A new trash enclosure is proposed on the southwest
corner of the site and is approximately 250 square feet in size on a
concrete slab. As proposed, the enclosure will be 6 feet in height,
constructed of masonry pilasters and cedar lumber.
L. Section 3.4.7(F)(5) — Historic Landscaping
Existing on -site, there are Crabapple trees along the south side of
Springfield Drive, that the City Forester estimates to be around 100 years
old. As such, these Crabapple trees will be preserved.
M. Section 3.5.1— Building Project and Compatibility
This standard requires that new projects be compatible with the
established architectural character and context of the general area. The
standard also states that where the architectural character is not
definitively established, new projects should establish an enhanced
Page 8
Carriage House Apartments, #F-L)P120035 March 21, 2v 13 Planning & Zoning Board
enclosed, located within the building, and 44 spaces will be distributed
among 4 exterior fixed bicycle racks.
H. Section 3.2.2(K)(1)(a)(1) — Parking Lots — Required Number of Spaces
This Section of the Code states that Multi -family dwellings within the
Transit -Oriented Development (TOD) Overlay Zone have no minimum
parking requirements. The project provides 58 parking spaces, thus
meeting the Land Use Code requirement.
The intent of removing the minimum parking requirements in the TOD was
to alleviate a barrier to redevelopment in the area, and to reflect the fact
that multi -modal travel options were available or planned for those areas.
The removal of minimum parking requirements in the TOD was not meant
to remove the entire obligation for development -related parking. Instead,
the provision was intended to recognize that the need for parking should
be a market -based decision based on specific project needs, the
surrounding context, and available travel options and facilities.
If Carriage House Apartments was held to the required minimum number
of spaces as it would be elsewhere in Fort Collins (non-TOD), then a total
of 96 parking spaces would be required. Instead, 58 parking spaces are
provided and supplemented with both interior and exterior bike parking for
103 bikes. The site is served by Transfort route 19 and a bus stop will be
located 20 feet directly east of Building 4. The proposed project
encourages alternative modes and further reinforces fundamental polices
of City Plan.
The table below illustrates how the proposed project compares to existing
projects located in the TOD in terms of parking provided.
Comparative Parking Analysis for Multi -Family Proiects located within the
TOD Overlay Zone
Project
Name
Location Units
Bedrooms
Parking
Spaces
Provided
Parking
Required
if Not in
TOD
20 1-bd
Pura Vida
518 W.
52
16 2-bd
900a 06
Apartments
Laurel
units
16 3-bd
49 spaces
spaces
Total: 100
12 1-bd
Flats at Oval
306 W.
47
19 2-bd
571-
402-83
Laurel
units
16 3-bd
spaces
spaces
Total: 96
Page 7
Carriage House Apartment& IDP120035 March 2 013 Planning & Zoning Board
slope and aspect of the different hydrozones. An irrigation plan will be
provided by the Applicant concurrently with their building permit
application. The water budget chart provided by the Applicant calls out
that the average water usage for the site is 13.48 gallons per square foot,
under the maximum 15 gallons per square foot permitted. The project
meets the water conservation standards.
D. Section 3.2.1(E)(4) — Parking Lot Perimeter Landscaping
The perimeter of the projects' vehicular use area will be effectively
screened from the residential uses to the south and west with a
combination of plant material featuring evergreen trees and a 6 foot tall
wood fence, meeting the requirements of this standard.
E. Section 3.2.1(F) - Tree Protection and Replacement.
This standard requires that existing trees be preserved to the extent
reasonably feasible. The City Forester conducted an on -site meeting with
the Applicant and determined a mitigation schedule. Currently, there are
57 trees existing on this site. For this project, 19 trees will be protected (in
place) and 43 trees will be removed. Of these 43 trees to be removed, 15
trees that are proposed to be removed require mitigation. These trees
have a mitigation value of 23 trees. The Applicant is providing 28 upsized
trees, meeting the mitigation requirement.
F. Section 3.2.2(B) — Access, Circulation and Parking,
The site is an infill location surrounded by existing development including
Colorado State University to the northeast. A new 6 foot attached sidewalk
will be constructed along Springfield Drive and a new 6 foot detached
sidewalk will be constructed along South Shields Street before joining the
existing attached sidewalk along Shields Street. The buildings will feature
connecting walkways out to Springfield Drive.
In terms of pedestrian connectivity to off -site destinations, there are
existing crosswalks at the Prospect Road and Shields Street and
Elizabeth Street and Shields Street signalized intersections. Additionally,
there is a striped crosswalk (across Shields Street) with a pedestrian
signal at Lake Street. The project meets connectivity requirements.
G. Section 3.2.2(C)(4) — Bicycle Facilities
This standard requires multi -family residential is required to provide 1 bike
parking space per bedroom with a minimum of 60% of these spaces
enclosed. The PDP proposes 97 bedrooms and requires 58 enclosed
bicycle parking spaces. As proposed, the project provides 103 bicycle
parking spaces total. Of these spaces, 59 bike parking spaces are
Page 6
Carriage House Apartments.,#F 120035 March 21, 2 Planning & Zoning Board
The proposed roof pitches for the buildings are 5:12, meeting the
minimum roof pitch of 2:12 and within the maximum roof pitch of 12:12.
The front elevation features a variety of treatments creating a well -
articulated appearance.
E. Section 4.9(E)(5) — Site Design
In the N-C-B District, permanent off-street parking areas cannot be located
any closer to a public street than the distance of the setback of the
building and the street. The parking stall furthest to the north is setback
approximately 40 feet from the property line and Building 1 is set back 30
feet, satisfying the standard.
3. Compliance with Applicable Article 3 - General Development Standards:
As illustrated by the previous section, the N-C-B zone contains numerous
specific standards. Where N-C-B Zone District standards of Article Four are more
specific or stringent, they prevail over the less specific or stringent standard that
may be found in the General Development standards of Article Three, except in
the case of the contextual setback regulations.
The PDP complies with the applicable General Development standards as
follows:
A. Section 3.2.1(C) & (D) — Landscaping and Tree Protection
The PDP provides full tree stocking and foundation shrubs around the
perimeter of the buildings. Existing crabapple trees will be retained.
B. Section 3.2.1(D)(3) — Minimum Species Diversity
This standard requires that no one species of tree (deciduous or
evergreen) will exceed the allowable 25 percent of the total number of
trees on the landscape plan. The landscape plan proposes 59 new trees,
and no more than 15 can be of one species. The most of any one species
is the Autumn Brilliance Serviceberry, with 15 trees, complying with the
standard.
C. Section 3.2.1(E)(3) — Water Conservation Standards
Water conservation techniques and materials are incorporated into the
Carriage House Apartments PDP landscape plan by the use of drought
tolerant trees and moderate water use plant materials where practical. An
automatic, underground irrigation system will be designed to address
specific needs of different plan species, soil conditions, as well as the
Page 5
Carriage House Apartments, IDP120035 March 2 013 Planning & Zoning Board
The N-C-B zone district permits a building to contain an amount of square
footage that equals the lot area, which in this case is 64,828 square feet.
The proposed square footage combined total is 39,281 square feet, thus
complying with the standard.
Additionally, the Land Use Code requires there to be a maximum Floor
Area Ratio of .33 on the rear 50 percent of the lot, or in this case, 10,433
square feet. The project proposes 10,272 square feet in the rear 50
percent of the lot, for a .325 rear Floor Area Ratio, meeting the standard.
C. Section 4.9(D)(6) - Dimensional Standards
PDP provides a lot width of approximately 400 feet, meeting the minimum
N-BC-B lot width requirement of 50 feet.
The project utilizes a contextual front yard setback of 30 feet. The
contextual setback provision of Section 3.8.19 states that regardless of the
minimum front setback requirement imposed by the zone district
standards (in this case 60 feet for areas within the West Central Plan
neighborhoods), Applicants are allowed to use a contextual front setback.
The setback of the abutting home to the west at 1201 Springfield Drive is
30 feet. Therefore, the project meets setback requirements.
The PDP provides a 15 foot 5 inch rear yard setback from the property to
the south, meeting the minimum requirement of 15 feet.
The PDP provides a 76 foot side yard setback along the west side
property line and a 27 foot setback along the east property line. This
complies with the standard that the side yard setback be a minimum of
five feet for the first 18 feet of height and then one additional foot for each
two feet of height thereafter. With a building height of 40 feet, the 22 feet
over the baseline of 18 feet requires 11 additional feet of side yard
setback. The 16 feet consists of five feet plus 11 feet to accommodate a
40 foot high building.
The building is three stories in height thus not exceeding the maximum
allowed of three stories in height for the N-C-B zone district.
D. Section 4.9(E)(1) - Building Design
Since the buildings are rectilinear, all exterior walls are constructed
parallel to or at right angles to the side lot lines.
The primary entrances of the buildings are oriented to Springfield Drive.
The entrances are enhanced by porches with overhangs.
Page 4
Carriage House Apartments.` #F 120035 March 21, 2. Planning & Zoning Board
minutes from October, 2012). As the residence at 1305 South Shields Street is no
longer eligible for Local Landmark Designation, it can be demolished, as proposed.
West Central Neighborhood Plan
The proposed project is located within the West Central Neighborhood Plan Area
(Adopted, 1999). The West Central Neighborhood Plan Area (WCNP) identifies the
subject parcels as a redevelopment area on page 2 of Chapter 3. For WCNP identified
redevelopment areas, the predominant uses (in this case single-family) are not
considered to be the most appropriate for the future and have potential for selective
conversion to more efficient uses. Moreover, the WCNP continues on to state that, "the
area along the west side of Shields Street,... are candidates for redevelopment in a
manner that allows conversion from (single-family) residential to multi -family
residential." The WCNP calls for redevelopment to create a buffer for the single-family
residential neighborhoods to the west from Shields Street. The proposed Project
Development Plan is an appropriate redevelopment of the area, and creates buffer in
conformance with the adopted policies of the West Central Neighborhood Plan.
2. Compliance with Article Four- Neiahborhood Conservation, Buffer District
(N-C-B) Standards:
As previously mentioned, the site is located within the Neighborhood
Conservation, Buffer District (N-C-B). The purpose of the N-C-B Zone District is:
"...intended for areas that are a transition between residential neighborhoods and
more intensive commercial -use areas or high traffic zones that have been given
this designation in accordance with an adopted subarea plan."
To the east of the site is a commercial area and Colorado State University; to the
west is primarily single family residential. The proposed project fits the intent and
purpose of the N-C-B Zone District.
A. Section 4.9(B) - Land Use
In the Neighborhood Conservation, Buffer zone district, the review and
decision making body for multi -family housing projects are governed by
the number of dwelling units and the residential net density. The proposed
land use is considered multi -family and is permitted in the N-C-B zone
district. The net area of the PDP is 1.45 acres. As 57 units are proposed,
the density is 39.3 dwelling units per net acre. Since the PDP contains
more than four dwelling units in one building, at a density of more than 24
dwelling units per net acre, the land use is permitted, subject to review
and a public hearing by the Planning and Zoning Board.
B. Section 4.9(D) - Density
Page 3
Carriage House Apartment PDP120035 March . 1013 Planning & Zoning Board
The proposed three story multi -family buildings were reviewed under the Code's
compatibility standards and found to be compatible with the surrounding context by its'
complementary architectural design featuring Craftsman architectural detailing and
pitched roofs, appropriately blending in with the adjacent single-family homes to the
south and west.
COMMENTS:
1. Background:
The surrounding zoning and land uses are as follows:
N: N-C-B—Neighborhood Conservation Buffer District (existing single-family
residential with free -stall barns and farm character);
S: R-L— Low Density Residential District (existing single-family residential
and Bennett Elementary School);
E: H-M-N—High Density Mixed -Use Neighborhood District (existing
commercial);
W: R-L— Low Density Residential District (existing single-family residential
neighborhoods)
In late 2011, the home located at 1305 South Shields Street was determined to be
individually eligible for Local Landmark designation by the Landmark Preservation
Commission Chair and the Community Development and Neighborhood Services
Director, under the provisions of the City's Municipal Code. At that time, this decision
was not appealable to City Council.
Additionally, the Historic and Cultural Resource Section of the Land Use Code (Section
3.4.7) protected the home from being demolished, however the Applicant was still
requesting to move forward with the redevelopment application and question of the
demolition of the home came before the Planning and Zoning Board in 2012 not as a
proposed development plan, but as two stand-alone requests for the modification of
standards to Sections 3.4.7(B) and 3.4.7(E) of the Land Use Code.
The Board denied the stand-alone modification requests and the Applicant appealed the
decision to City Council in April, 2012. The City Council upheld the Board's denial
decision, and instructed Staff to revisit the determination of eligibility section of the
Municipal Code.
In summer of 2012, changes were made to the Municipal Code relating to the
determination of Local Landmark eligibility process. In September 2012, the Applicant
provided new information to the Landmark Preservation Commission regarding the
home at 1305 South Shields Street and in October, 2012 the Commission overturned
the previous determination that the home was individually eligible for Local Landmark
Designation (please see page 5 of the attached Landmark Preservation Commission
Page 2
,moof
t` Collins
ITL . NO 5.
MEETING DATE , yr l
STAFF L&VIA`66rD
PLANNING & ZONING BOARD
PROJECT: Carriage House Apartments, Project Development Plan,
#PDP120035
APPLICANT: Mr. Chuck Bailey
Catamount Properties, Ltd.
7302 Rozena Street
Longmont, CO 80503
OWNER: Carlson Residential
210 Hollyhill Lane
Denton, TX 76205
PROJECT DESCRIPTION:
This is a request to demolish two existing single family homes at 1305 and 1319 South
Shields Street and in their place, construct five, three story multi -family buildings,
combining the two lots for a 1.48 acre site. The project proposes 57 units to be divided
among one, two and three -bedroom apartments for a total of 97 bedrooms. Parking
would be in the rear with 58 spaces gaining access off of Springfield Drive. The project
is located in the Neighborhood Conservation Buffer (N-C-B) District and is within the
Transit -Oriented Development (TOD) Overlay District.
RECOMMENDATION: Approval
EXECUTIVE SUMMARY:
Multi -family is permitted in the N-C-B zone district. The Project Development Plan
(PDP) complies with development standards of the N-C-B Zone District and with the
applicable General Development Standards of the Land Use Code. After additional
information was presented by the Applicant to the Landmark Preservation Commission
regarding the existing single family home at 1305 South Shields Street, the property
was re -reviewed and found not to be individually eligible for Local Landmark designation
and is allowed to be demolished under the provisions of the Municipal Code and Land
Use Code.
Current Planning 281 N College Ave - PO Box 580 - Fort Collins, CO 80522-0580
fcgov.com/currentplanning 970.221.6750