HomeMy WebLinkAboutRIDGEVIEW CLASSICAL SCHOOL - SPAR - 16-01 - CORRESPONDENCE - (4)9 Issue Contact: Jeff Hill Show and label all existing and proposed water/sewer services, curb stops, meter pits, etc. 10 Issue Contact: Jeff Hill Will proposed temporary office and class room need water or sewer services? Zoning 1 Issue Contact: Gary Lopez show in more detail on overall site plan location of school,and other features 2 Issue Contact: Gary Lopez add'I landscaping in parking lot required - some missing in islands 3 any elevations on the additions? Issue Contact: Gary Lopez 4 Issue Contact: Gary Lopez parking lot lighting may need updated if not already met to LUC standards Be sure and return all of your redlined plans when you re -submit. If you have questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Yours Truly, BRIAN GRUBB City Planner 3 of 4 Stormwater Utility 7 Drainage Requirements Issue Contact: Wes Lamarque The City of Fort Collins requires all development projects, new or modifications to existing, creating an additional impervious area of 350 SF or more to provide a storm drainage design per the City's Storm Drainage Design Criteria Manual. This needs to include grading and drainage plans, as well as a drainage report. Transportation Planning 17 Issue Contact: Tom Reiff Student pick-up and drop-off will not be permitted along Lemay or Stuart St. 18 Issue Contact: Tom Reiff Create a more defined pick-up and drop-off location within the site by perhaps eliminating some of the parking near the entrance (see red lines), This would improve vehicular circulation and the safety of the children. 19 Issue Contact: Tom Reiff Transportation Impact Study is required — F IER l G k. 20 Issue Contact: Tom Reiff If a classroom is built near the northeast corner a defined walkway for students and staff to access the main building is necessary (see red lines). 21 Issue Contact: Tom Reiff Locate bike parking near the building's main entrance with a ramp for accessibility. 22 Issue Contact: Tom Reiff Increase the attached sidewalk width along Stuart to a minimum of 6-feet for fronting property. ,ate P� 23 Issue Contact: Tom Reiff Sidewalk connections from Stua a`fiLemay to the building's main entrance is required (see red lines). Co S Water Wastewater 8 Issue Contact: Jeff Hill Will new or larger water/sewer services be needed for the proposed addition? 2 of 4 STAFF PROJECT REVIEW DUNAMIS III UNITED PARTNERSHIP Date: 06/06/2001 ZEILER-PENROCK, INC. 2127 BRYANT ST. #600 DENVER, CO 80211 Staff has reviewed your submittal for RIDGEVIEW CLASSIBAL SCHOOL SITE PLAN ADVISORY REVIEW #16-01, and we offer the following comments: ISSUES: Engineering PFA 11 Issue Contact: Dave Strinqer rJm Z.O. W " 12 Issue Contact: Dave Strinqer I only received a site plan that shows trees, parking lots and buildings. No other underground or below grade features shown 13 Issue Contact. Ron Gonzales ACCESS A fire lane may be required 14 Issue Contact: Ron Gonzales WATER SUPPLY A hydrant is required within 300 feet of the building; on 600 ft centers Fire flow = 1500 gpm @ 20 psi 15 Issue Contact: Ron Gonzales ADDRESS Required to be visible from the street on which you front minimum 6" numerals on contrasting background 16 Issue Contact: Ron Gonzales FIRE SPRINKLERS This change of occupancy will likely prompt a sprinkler requirement for the entire building. Police 24 Issue Contact: Joseph Gerdom Lighting: clarify type and location of parking lot and building entrance lighting. 1 of 4