Loading...
HomeMy WebLinkAboutRIDGEVIEW CLASSICAL SCHOOL - SPAR - 16-01 - CORRESPONDENCE -at 7:45 and Intermediate at 7:55 to eliminate any traffic congestion. We hope this clarifies some of the issues and concerns. It is the intent of Ridgeview Classical Schools to provide the community with a quality, education alternative and that the facility is a major component of this goal. Please forward any questions and concerns and we look forward to working together in the success of this project. Yours truly, r6Joh C. Hellgre A Principal Zeiler -Pennock, Inc./OHA Encl. drawings transportation impacts assessment Preliminary Storm Detention Analysis ✓' contrasting materials, color and brick masonry to give the building a new, updated facade along Lemay Ave, the addition will be an important phase to this project. To address the city's concerns, elevations will be made available for comment as soon as they are developed and will represent the level of quality expected by a facility of this kind. ❑ Phase III: Move -Out of the Church, Full Use of the Facility - Summer 2002 Once the church has moved, upon completion of their new facility, the school will have full use of the site. Remodel of the remaining church facility will occur at this time to satisfy the school's requirements. The temporary classrooms will be removed, Summer 2002. Any other improvements can be analyzed at this time. Site Issues: ❑ Shared Use Parking: Parking Requirements: The existing parking lot contains 201 spaces. 187 spaces will be available after the temporary classrooms have been located and will satisfy all the shared parking scenarios. • Weekend Use: 187 spaces existing total. • Existing Sanctuary: 700 seats/4spaces = 175 spaces required. (Evening/Weekend use.) • Weekday Use: 120 Spaces Total • Church: Limited Staff - 10 spaces • School: 25 staff and parent volunteers, 10-15 high school able to drive. • Medical Office Building: 50 shared spaces. • Children's World: 20 shared spaces. ❑ Site Circulation: Drop -Off and pick-up will occur on the south side of the building. Cars will be required to enter from Stuart St. only, drop-off at the south walk and loop the parking lot and exit on the existing Stuart St. exit or by right turn to Lemay northbound as recommended by the enclosed traffic study. The loop will provide plenty of interior site circulation to eliminate any backup on Stuart St. and potentially Lemay Ave. The school will also have a staggered start time with High School starting at 7:35, Elementary K.1 ZEILER-PENN0CK91NC./OHA LN ARC HITECTS -ENGINEERS PRINCIPALS July 13, 2001 PAUL R. PENNOCK W. KELLY OLIVER JOHN C. HELLGREN City of Fort Collins 281 N. College Ave. P.O. Box 580 Ft. Collins, CO 80522-0580 Re: Ridgeview Classical Schools 1800 S. Lemay Ave. To Whom It May Concern: In response to the City of Fort Collin's questions in regard to Ridgeview Classical Schools and the Timberline Church facility, outlined here is a phased use master plan that will further address the time line and scope of the proposed project. PROJECT PHASING: ❑ Phase I: Shared use with the church for Fall 2001 This phase consists of limited use of the existing church facility and limited use of the site for location of temporary classrooms. Specifically, a portion of the second floor classrooms will be remodeled for 4 high school classrooms along with use of the restrooms. Life safety improvements throughout the church as required by current code for E-occupancy such as installation of fire alarm will be done at this time. The church has asked for no changes to the site until after the church has left in Summer 2002. ❑ Phase II: Classroom Addition - Spring 2002 The classroom addition will follow the Phase I remodel and begin as soon as design and drawings are complete, approximately August 2001. The classroom temporaries will fill some of the school's needs until completion and other uses will be postponed until Summer 2002 when the church has moved out. The addition design is at the concept master plan stage as illustrated on the site plan. Building design has not been developed at this time. Conceptually, the addition will be complementary to the existing brick masonry building conveying the new use of the facility. Using 2727 BRYANT ST. Suite 600 DENVER, COLORADO 80211 (303) 455-3322 Fax (303) 455-3708