HomeMy WebLinkAboutREMINGTON ROW (FORMERLY REMINGTON ANNEX) - FDP - FDP130017 - CORRESPONDENCE -Department: Water-Wastewaer Engineering • Contact: Roger Buffington, 970-221.6854, rbuffington(a)fcgov.com Topic: Construction Drawings Comment Number: 1 Comment Originated: 06/11/2013 06/11/2013: Label/note the curb stops on the water services. Comment Number: 2 Comment Originated: 06/11/2013 06/1112013: Will lowerings be required on the fire lines crossing the electric duct bank? Pothole? Department: Zoning Contact: Noah Beals, 970.416.2313, nbeals(cDfcgov.com Topic: General Comment Number: 1 Comment Originated: 06/11/2013 O6/11/2013: Plans should be labeled Final Plan now (rename all the PDP labels) Comment Number: 2 Comment Originated: 06/11/2013. O6/11/2013: On the site plan include a note with reference to the approved modifications. Comment Numberq *Comment Originated: 06/12/2013 O6/12/2013: The City would like to discuss the landscaping in the PLDs. Cobble rock has not worked well in the past in other developments. Comment Number: 3 Comment Originated: 06/12/2013 O6/12/2013: Please add details for the outlet works for the detention ponds in the parking lot and the front yard PLDs. Comment Number: 4 Comment Originated: 06/1212013 06/12/2013: Please see other minor redlined comments on the utility plan set. Department: Technical Services Contact: Jeff County, 970.221-6588, jcounty(rDfcgov.com Topic: Building Elevations Comment Number: 1 O6/12/2013: No comments. Topic: Construction Drawings Comment Originated: 06/12/2013 Comment Number: 2 Comment Originated: 06/12/2013 06112/2013: There are line over text issues on sheets HC01, UT01, GR01 & RDOt. See redlines. Comment Number: 3 Comment Originated: 06/12/2013 O6/12/2013: Please mask the text in hatched areas on sheets HC01, DR01 & UT01. See redlines. Topic: Landscape Plans Comment Number: 4 Comment Originated: 06/12/2013 O6112/2013: There are line over text issues on sheet 1-1. See redlines. Comment Number: 5 Comment Originated: 06/12/2013 O6/12/2013: Please mask the text in hatched areas on sheet PDP2. See redlines. Topic: Plat Comment Number: 6 Comment Originated: 06/12/2013 O6/12/2013: Should "Remington Annex" in the Owners signature block be "Remington Row"? See redlines. Topic: Site Plan Comment Number: 7 Comment Originated: 06/12/2013 O6/12/2013: There are line over text issues on sheet PDP2. See redlines. Comment Number: 8 Comment Originated: 06/12/2013 06/12/2013: Please mask the text in hatched areas on sheet PDP2. See redlines. Department: Traffic Operation Contact: Ward Stanford, 970.221.6820, wstanford(o)fcgov.com Topic: General Comment Number: 1 Comment Originated: 06/12/2013 O6/12/2013: No Comments. Topic: General • 40 Comment Number: 1 Comment Originated: 05/30/2013 05/30/2013: Unique street addresses will be assigned to each structure and will eliminate the building letter designations. The north structure will be addressed as 705 Remington St and the south structure will be addressed as 715 Remington St. Unit addresses can be requested through the GIS Department for these two structures as specified below. The middle structure will be assigned 711 Remington St and no additional unit designation will be necessary. Comment Number: 2 Comment Originated: 05/30/2013 05/30/2013: Projects with three or more tenant units require the Unit Level Addressing form to be completed and submitted to the GIS Department once plans have met final approval through Development Review and are recorded with the City. This can occur anytime during construction, but before any utilities are set within the structure to ensure the meter banks match the official addressing for the structure. The Unit Level Addressing form can be obtained by contacting the GIS office at gis@fcgov.com or (970) 416-2483. Addressing will be determined by the GIS Department. Department: Park Planning Contact: Craig Foreman, 970.221.6618, cforeman(&fcaov.com Topic: General Comment Number: 1 05/17/2013: No comments Department: PFA Contact: Jim Lynxwiler, 970-416.2869, ilynxwilerftoudre-fire.org Topic: General Comment Number: 01 06/1112013: All prior fire department concerns have been resolved. Department: Stormwater Engineering Contact: Jesse Schlam, 970-218-2932, 0schlam0fcgov.com Topic: Erosion Control Comment Number: 1 Comment Originated: 05/17/2013 Comment Originated: 06/11/2013 Comment Originated: 05/29/2013 05/29/2013: The current Erosion Control Materials Submitted do not meet requirements. See redlines for corrections in the Erosion Control Plan. The plan should also include a sequence chart. The Erosion Control Report (Stormwater Management Control) submitted was incomplete, please address 1) Nature and Purpose of the Construction in the Site Description, 2) Need an actual number of percent vegetation, 3) Seed/Sod Mix, 4) Soil Amendment Requirements, 5) Mulch Requirements. If you need clarification concerning this section, or if there are any questions please contact Jesse Schlam 970-218-2932 or email @ jschlam@fcgov.com Contact: Wes Lamarque, 970.416.2418, wlamarauena.fcgov.com Topic: General Comment Numbe4P *Comment Originated: 06/12/2013 06/12/2013: The alley plan and profile sheet has me a little confused with the information being shown with how the transition from inverse crown to slope to one side occurs. I would envision that the plan view would show a flowline that transition from the center to the east side of the alley as it heads north through the identified transition area. Perhaps that is what's occurring, though I'm not sure. Perhaps some cross -sections in three locations along the transition area would help identify what is to occur. Comment Number: 4 Comment Originated: 06/12/2013 O6/12/2013: Is a 50.51 % flowline grade actually occurring and is the centerline profile approaching Laurel Street having a reverse grade compared to the right flowline? It might be beneficial to meet of line for more clarity on my part. Comment Number: 5 Comment Originated: 06/12/2013 06/12/2013: Please provide a concrete joint pattern detail for the alley to illustrate panel size, dowelling, joint type, etc. Comment Number: 6 Comment Originated: 06/1212013 06112/2013: I'm understanding that variances were approved to not require a utility easement along Remington Street and require a 5' utility easement along the alley. Please have this variance approval identified on general note #48. Topic: General Comment Number: 1 06112/2013: Comment Originated: 06/12/2013 An easement from the property owner located on the southeast corner of the alley and Laurel Street is needed for the offsite work. Topic: Plat Comment Number: 7 Comment Originated: 06/12/2013 O6112/2013: The certification of dedication language on the plat has been updated. Please provide a contact information email address for me to forward the current language. Department: Environmental Planning Contact: Lindsay Ex, 970.224.6143, lex fcgov.com Topic: General Comment Number: 1 Comment Originated: 05/22/2013 05/22/2013: No comments. Department: Historical Preservation Contact: Karen McWilliams, 970.224.6078, kmcwilliams(a)fcclov.com Topic: General Comment Number: 1 Comment Originated: 06/11/2013 06/11/2013: Per Hogestad, the owners' historic preservation architect, is reviewing some design alterations contained in the submitted Final Plans. These design changes are not anticipated to be significant, and should not affect the projects compliance with LUC Section 3.4.7. Department: Internal Services Contact: Todd Reidenbach, , City of Fort Collins June 13, 2013 Jeff Hansen Vaught Frye Larson Architects 401 Mountain Avenue Suite 100 Fort Collins, CO 80521 RE: Remington Row (formerly Remington Annex), FDP130017, Round Number 1 Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6760 970.224.6134 - fax fcgov. com/deve/opmentreview Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Courtney Levingston, at 970-416-2283 or clevingston@fcgov.com. Comment Summary: Department: Current Planning Contact: Courtney Levingston, 970.416.2283, clevingstonbfcnov.com Topic: Building Elevations Comment Number: 2 Comment Originated: 06/07/2013 06107/2013: Since GIS has determined that each building will be assigned a separate address, please update the east graphics on PDP3 Topic: General Comment Number: 1 Comment Originated: 06/07/2013 06/07/2013: The bike racks are shown only 9 inches from the wall. These will need to be at least 24 inches from the wall according to the standards contained in Section 17.4.2 of the Larimer County Urban Area Street Standards. 9 inches is not enough room to secure the bike to the rack. Department: Engineering Development Review Contact: Marc Virata, 970-221.6567, mvirata(&fcgov.com Topic: Construction Drawings Comment Number: 2 Comment Originated: 06/12/2013 06/12/2013: The spacing of the street cuts shown on Remington Street has three street cuts occurring at a distance of 64 feet. At a distance of less than 75 feet, LCUASS requires that the street repair be expanded to extend from the westernmost patch through to the easternmost patch. This should be indicated on the plans.