Loading...
HomeMy WebLinkAboutLITTLE BEAR'S CHILD CARE - PDP - PDP120017 - CORRESPONDENCE - (3)Department: Zoning Contact: Gary Lopez, 970.416.2338, gloaez@fcgov.com Topic: General Comment Number: 1 Comment Originated: 06/15/2012 O6/15/2012: Reminder that all signs and their locations are not approved by the PDP or the FDP. A separate sign permit is required for approval, this includes refacing of existing signs. 14 Department: Technical Services Contact: Jeff County, 970.221.6588, Icountynafcoov.com Topic: Building Elevations Comment Number: 5 Comment Originated: 06/19/2012 06/19/2012: Please change the sheet number to 4 of 4. Topic: Construction Drawings Comment Number: 6 Comment Originated: 06/19/2012 O6/19/2012: Please change the datum for the benchmark on sheets 1 & 2. The City of Fort Collins Vertical Control Network is on the 1929 Datum (unadjusted). Comment Number: 7 Comment Originated: 06/19/2012 O6/19/2012: Please remove "Riverside II Condo Amended" from the sub -title. The Site Plan shows Lot 2, Viking I Subdivision being part of this project. Please add this to the sub -title. Comment Number: 8 Comment Originated: 06/19/2012 O6/19/2012: Please correct the lot designations on sheets 3 & 4. See redlines. Comment Number: 9 Comment Originated: 06/19/2012 06/19/2012: There are line over text issues on sheet 3. Topic: General Comment Number: 10 Comment Originated: 06/19/2012 O6/19/2012: The 2 legal descriptions for the right of way dedication state that the land is for easement purposes. Please change this to right of way. Topic: Landscape Plans Comment Number: 4 Comment Originated: 06/19/2012 06/19/2012: Please block out around the text on sheet 3. See redlines. Topic: Site Plan Comment Number: 1 Comment Originated: 06/19/2012 O6/19/2012: Please increase the size of the legal description text on sheet 1. See redlines. Comment Number: 2 O6/19/2012: Please increase the text size on sheet 2. See redlines. Comment Number: 3 O6/19/2012: Please block out around the text on sheet 2. See redlines. Department: Water -Wastewater Engineering Contact: Roger Buffington, 970.221.6854, rbuffington(a fcgov.com Topic: Landscape Plans Comment Number: 1 Comment Originated: 06/19/2012 Comment Originated: 06/19/2012 Comment Originated: 06/19/2012 06119/2012: If additional landscaping is planned along Riverside, show existing water/sewer services and fire line and provide the required separation distances. Department: Zoning i Department: Light And Power Contact: Doug Martine, 970-224.6152, dmartine(cbfcgov.com Topic: General Comment Number: 2 Comment Originated: 06/05/2012 O6/05/2012: Electric development charges will apply for the lot at 1230 E. Elizabeth, even if no power is required to the site. Comment Number: 3 Comment Originated: 06/05/2012 06/05/2012: Clearance of 8 ft. on the front (door) side, and 3 ft. on the other three sides of the transformer must be maintained. Also, the transformer must be accessible to utility personnel and equipment. The electric meter(s) must be accessible to utility personnel at all times without obtaining permission or an escort. Comment Number: 4 Comment Originated: 06/05/2012 06/05/2012: There is an existing streetlight on Elizabeth St. as shown on the site plan. Street tree locations must be adjusted to provide 40 ft. clearance between the light pole and street trees (15 ft. if the tree is an ornamental type). Department: PFA Contact: Ron Gonzales, 970.416-2864, rgonzales(a)uoudre-fire.org Topic: General Comment Number: 1. Comment Originated: 06/19/2012 06/19/2012: Address numerals required to be visible from the street fronting the property. Comment Number: 2. Comment Originated: 06/19/2012 O6/19/2012: This is classified as an 1-4 institutional day care facility. It is required to be licensed by the State of Colorado. Comment Number: 3. Comment Originated: 06/19/2012 06/19/2012: The existing fire sprinkler system shall be extended to cover any new areas in need of proper fire protection coverage. Comment Number: 4. Comment Originated: 06/19/2012 O6/19/2012: Should grease -laden vapors be generated while heating meals, fire protection will be required under a Type 1 hood. Department: Stormwater Engineering Contact: Wes Lamarque, 970.416-2418, wlamargue(&fcgov.com Topic: General Comment Number: 1 Comment Originated: 06/19/2012 O6/19/2012: Please use the City's hydrology computation method per our Stormwater Criteria Manual. This should actually reduce the quantity detention volume requirement. Comment Number: 2 Comment Originated: 06/19/2012 06/19/2012: Discussions need to take place on what treatment method is best for water quality. Comment Number: 3 Comment Originated: 06/19/2012 O6/19/2012: Stormwater is ready for a public hearing. Department: Engineering Development Review Contact: Andrew Gingerich, 970.221.6603, agingerich(a.fcgov.com Topic: Construction Drawings Comment Number: 3 Comment Originated: 06/19/2012 06/19/2012: Please confirm with Water/Wastewater but engineering would request that existing and proposed (if applicable) water, sewer, and services be shown on the grading plan if a utility plan is not provided. Topic: General Comment Number: 2 Comment Originated: 06/19/2012 06/19/2012: Thank you to the Owner, Applicant and Consultant's for addressing the conceptual review comments adequately. , Comment Number: 4 Comment Originated: 06/19/2012 06/19/2012: As mentioned in Conceptual Review this project is responsible for dedicating right of way for East Elizabeth to meet the 76' wide right of way for collector with parking. The Viking I subdivision plat shows 60' was dedicated previously, however the right of way proposed to be dedicated by separate document is only 6' and the proposed dedication is shown as 7' on the site plan. Please provide additional information to support only dedicating 6' of additional right of way. If no other documents support a situation where this project is responsible for half the remaining right of way then 8' will need to be dedicated. Comment Number: 5 Comment Originated: 06/19/2012 06/19/2012: It appears that fencing is proposed inside of the existing access and utility easement off of Elizabeth Street. The fence will need to be located outside of the easement. Contact: Sheri Langenberger, 970.221.6573, slangenberger(a)fcgov.com Topic: General Comment Number: 1 Comment Originated: 06/14/2012 O6/14/2012: The project owes an additional $215 for TDR fees. The acerage calculation on the application did not match that identified on the site plan. Department: Environmental Planning Contact: Lindsay Ex, 970.224-6143, lex( fcgov.com Topic: General Comment Number: 1 06108/2012: No comments. Department: Light And Power Contact: Doug Martine, 970-224-6152, dmartine(a.fcgov.com Topic: General Comment Number: 1 Comment Originated: 06/08/2012 Comment Originated: 06/05/2012 O6/05/2012: Records show that the existing building has 5 electric meters of 100 amps each (500 amps total capacity) at 120/240 volt single phase. If any changes to the existing electric service is necessary, please contact Light & Power Engineering at (970)221-6700. v City of Fort Collins June 20, 2012 Troy Jones MTA Planning & Architecture 108 Rutgers Ave Fort Collins, CO 80525 RE: Little Bear's Child Care, PDP120017, Round Number 1 Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6760 970.224.6134 - fax fcgov, com/developmentreview Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Courtney Levingston, at 970-416-2283 or clevingston@fcgov.com. Comment Summary: Department: Current Planning Contact: Courtney Levingston, 970-416-2283, clevingston(a)fcgov.com Topic: General Comment Number: 1 Comment Originated: 06/14/2012 06/14/2012: Is the Shed exisiting or proposed? If proposed, please provide detail on elevations. Comment Number: 2 Comment Originated: 06/14/2012 06/14/2012: Please call out the location of the transformer on landscape plans. All utilities must be screened. Comment Number: 3 Comment Originated: 06/14/2012 06/14/2012: Please call out where the main entrance will be located. Topic: Site Plan Comment Number: 1 Comment Originated: 06/14/2012 06/14/2012: For final, please provide bike rack, trash enclosure and automobile parking stall detail to ensure each meets the LUC standards. Comment Number: 2 Comment Originated: 06/14/2012 06/14/2012: Plese call out the limits of development. I believe this is signified by the dashed line, correct? Comment Number: 3 Comment Originated: 06/14/2012 06/14/2012: The Land Use Code only requires 1 handicapped parking space LUC3.2.2(K)