HomeMy WebLinkAboutFOX POINTE PLAZA - PDP - 16-06 - REPORTS - RECOMMENDATION/REPORTFox Pointe Plaza - PDP, #16-06
September 21, 2006 Planning and Zoning Board Hearing
Page 7
4. Neighborhood Information Meeting
The Fox Pointe Plaza, PDP contains a proposed land use that is permitted
in the E — Employment Zoning District subject to a Planning and Zoning
Board (Type 2) review. The proposed use is a Convenience Shopping
Center containing office, retail, restaurant and drive-in restaurant uses.
The LUC does require that a neighborhood meeting be held for a Type 2
development proposal unless the Director determines that the
development proposal would not have significant neighborhood impacts..
In this case the Director did determine that the proposed Convenience
Shopping Center, being similar uses to existing uses in the fully developed
area surrounding the property, would not have significant impacts on the
commercial and residential neighborhoods; therefore, a City -facilitated
neighborhood meeting was not held to discuss this proposal.
FINDINGS OF FACT/CONCLUSIONS
After reviewing the Fox Pointe Plaza, PDP, staff makes the following findings of
fact and conclusions:
1. The proposed land use, a Convenience Shopping Center, is permitted in
the E — Employment Zone District.
2. The PDP complies with all applicable General Development Standards
contained in Article 3 of the Land Use Code.
3. The PDP complies with all applicable Land Use and Development
Standards contained in Article 4, Division 4.22 of the Land Use Code.
RECOMMENDATION:
Staff recommends approval of the Fox Pointe Plaza, Project Development Plan -
#16-06.
Fox Pointe Plaza - PDP, #16-06
September21, 2006 Planning and Zoning Board Hearing
Page 6
The west elevation of the office/retail/restaurant building will be
oriented to JFK Parkway, with greater than 50% of the west
elevation located 15' - 25' from the right-of-way for that street, being
a 4-lane arterial.
Build -to Line. Section 3.5.3(B)(2)(b) states that:
Buildings shall be located no more than 15' from the right-of-
way of an adjoining street if the street is smaller than a full
arterial of has on -street parking.
The north side of the building will be oriented to Boardwalk Drive,
with the north side located 20' -22' from the existing right-of-way for
that street, being a 2-lane arterial. There is a significant pedestrian
plaza on the east side and at the northeast corner of the building
that provides site improvements designed for pedestrian interest,
comfort, and visual continuity between the building entries and the
public sidewalk along Boardwalk Drive. In light of the plaza and
other pedestrian -oriented site improvements, the exception to the
build -to line standard, as set forth in Section 3.5.3(B)(2)(d)l , is
warranted.
Build -to Line. Section 3.5.3(B)(2)(c) states that:
Buildings shall be located at least 10' and no more than 25'
behind the street right-of-way of an adjoining street that is
larger than a two -land arterial that does not have on -street
parking.
The west elevation of the office/retail/restaurant building will be
oriented to JFK Parkway, with the majority of the west elevation
located 15' - 25' from the right-of-way for that street, being a 4-lane
arterial.
The drive-thru coffee shop building, consisting of drive-thru
windows on both sides of the building, does not relate directly to
either Boardwalk Drive or JFK Parkway. There is, however, an
enhanced pedestrian walkway between this building and the
pedestrian plaza in front of the office/retail/restaurant building.
Fox Pointe Plaza - PDP, #16-06
September 21, 2006 Planning and Zoning Board Hearing
Page 5
d. The proposal complies with Section 3.2.2(K)(2) in that it
provides 39 parking spaces for the 11,900 square feet of
leasable floor area for the Convenience Shopping Center,
containing office, retail, restaurant, and drive-in restaurant uses.
This is less than the 59 spaces allowed for the proposed land
use.
B. Division 3.3, Engineering Standards
1. Section 3.3.5, Engineering Design Standards
The proposal complies with the design standards, requirements,
and specifications for the services as set forth in this section.
C. Division 3.5, Building Standards
1. Section 3.5.1, Building and Project Compatibility
The PDP satisfies the criteria set forth in this section relating to the
physical and operational characteristics of the buildings and uses,
which are considered to be compatible within the context of the
surrounding area.
2. Section 3.5.3, Mixed Use, Institutional and Commercial Buildings
The PDP satisfies all Relationship of Buildings to Streets,
Walkways and Parking standards.
Orientation to Build -to Lines for Streetfront Buildings. Section
3.5.3(B)(2)(a) states that:
To establish "build -to" lines, buildings shall be located and
designed to align or approximately align with any previously
established building/sidewalk relationships that are
consistent with this standard. Accordingly, at least thirty (30)
percent of the total length of the building along the street
shall be extended to the build -to line area. If a parcel, lot or
tract has multiple streets, then the building shall be built to at
least two (2) of them according to (b) through (d) below, i.e.
to a street corner.
Fox Pointe Plaza - PDP, #16-06
September21, 2006 Planning and Zoning Board Hearing
Page 4
3. Article 3 - General Development Standards
The PDP complies with all applicable General Development Standards as
follows:
A. Division 3.2, Site Planning and Design Standards
1. Section 3.2.1, Landscaping and Tree Protection
a. The proposal complies with Section 3.2.1(D)(1)(c) in that it will
provide "full tree stocking" within 50' of the proposed
office/retail/restaurant building to be located at the corner of
Boardwalk Drive and JFK Parkway, according to the standards
set forth in this section.
b. The proposal complies with Section 3.2.1(D)(2)(b) in that
existing and new canopy shade (street) trees are provided at 35'
- 40' spacing in the parkway (between back of curb and
sidewalk) along JFK Parkway and at 35' - 40' spacing in the
parkway (detached sidewalk) and behind the sidewalk
(attached) along Boardwalk Drive.
2. Section 3.2.2, Access, Circulation and Parking
a. The proposal complies with Section 3.2.2(C)(4)(a) in that it
provides secure and conveniently located bicycle parking in the
amount of 10% of the total number of automobile parking
spaces on -site, satisfying the minimum requirement of 5%. The
bicycle rack in the pedestrian plaza between the two buildings
will accommodate 4 - 5 bicycles and there will be 39 vehicular
parking spaces on -site.
b. The proposal complies with Section 3.2.2(C)(5) in that it
provides direct, safe, and continuous walkways and bicycle
connections to major pedestrian and bicycle destinations in the
surrounding area.
c. The proposal complies with Section 3.2.2(D) in that it provides
for safe, convenient, and efficient bicycle, pedestrian, and
vehicular movement to and through the site. Vehicular access
will occur via one existing curb cut from JFK Parkway and one
new curb cut from Boardwalk Drive.
Fox Pointe Plaza - PDP, #16-06
September 21, 2006 Planning and Zoning Board Hearing
Page 3
E: E; existing federal building, office park (U.S. Post Office,
Promontory)
W: C; existing commercial/office/retail park (Fountainhead Center)
The property was annexed in December, 1979 as part of the South
College Properties Lemay Annexation.
The property currently is part of the U.S. Post Office -owned property.
2. Article 4 - Districts
The PDP complies with the applicable District standards as follows:
A. Division 4.22 - Employment Zone District
Office uses are permitted in the E — Employment Zoning District,
subject to administrative review.
This proposal, a Convenience Shopping Center, being an infill
project on a small parcel of land in a fully developed area, complies
with the purpose of the E District as it is a permitted, secondary
land use in developed commercial and residential corridors
containing a mix of office, retail, and residential uses along
Boardwalk Drive and JFK Parkway. Also, the City's main post
office, a Federal building, is directly south of this site.
1. Section 4.22(D)(4), Dimensional Standards
The proposed height for the office/retail/restaurant building will be
28'-6", with a clock tower at the main entry extending to 3T-10" in
height. This is a 2-story building. The proposed height for the drive-
thru coffee shop building will be 17'- 6". This is a 1-story building.
Section 4.22(D)(4)(a) states that the maximum height for all
nonresidential buildings shall be 4 stories. Typically, a 4-
story building would be a minimum of 48' - 50' in height. The
proposed building height of 28'-6", with a 37'-10" tower
element, in the shopping center is well under the maximum
height allowed.
Fox Pointe Plaza - PDP, #16-06
September 21, 2006 Planning and Zoning Board Hearing
Page 2
* standards located in Division 3.2 - Site Planning and Design
Standards, Division 3.3 - Engineering Standards, and Division 3.5 -
Building Standards, Division 3.6 - Transportation and Circulation of
ARTICLE 3 - GENERAL DEVELOPMENT STANDARDS; and
* permitted uses and standards located in Division 4.22 - Employment
District of ARTICLE 4 - DISTRICTS.
Office uses are permitted in the E — Employment Zoning District, subject to
administrative (Type 1) review. Retail, restaurant, and drive-in restaurant (drive-
thru coffee shop) uses are permitted only in Convenience Shopping Centers as a
Planning and Zoning Board (Type 2) review in the E District. The purpose of the
E District is:
Intended to provide locations for a variety of workplaces including light
industrial uses, research and development activities, offices and
institutions. This District also is intended to accommodate secondary uses
that complement or support the primary workplace uses, such as hotels,
restaurants, convenience shopping, child care and housing.
Additionally, the Employment District is intended to encourage the
development of planned office and business parks; to promote excellence
in the design and construction of buildings, outdoor spaces, transportation
facilities and streetscapes; to direct the development of workplaces
consistent with the availability of public facilities and services; and to
continue the vitality and quality of life in adjacent residential
neighborhoods. 1�
This proposal, a Convenience Shopping Center, complies with the purpose of the
E District as it is a permitted, secondary land use in a developed commercial and
residential corridor containing a mix of office, retail, and residential uses along
Boardwalk Drive and JFK Parkway. Also, the City's main post office, a Federal
building, is directly south of this site.
COMMENTS:
Background
The surrounding zoning and land uses are as follows:
N: E; existing office park (Landings)
S: E; existing federal building (U.S. Post Office)
ITEM NO. 4
MEETING DATE 9/21/06
STAFF Steve nlr
City of Fort Collins PLANNING AND ZONING BOARD
STAFF REPORT
PROJECT: Fox Pointe Plaza, Project Development Plan (PDP) - #16-06
APPLICANT: ZTI Development Group
c/o Ed Zdenek
631 West Mulberry Street
Fort Collins, CO. 80521
OWNER: U.S. Postal Service
c/o Randy Alder
160 Inverness Drive West, #400
Englewood, CO. 80112
Moomey Enterprises, LLC
c/o Larry and Judith Moomey
303 Apache Drive
Lexington, NE. 68850
PROJECT DESCRIPTION:
This is a request for a Convenience Shopping Center on 1.2 acres located at the
southeast corner of Boardwalk Drive and JFK Parkway, just north of the main
U.S. Post Office. The proposed uses are retail, office, and restaurant in a 2-story
building at the corner and a drive-thru coffee shop in a 1-story building interior to
the site. Access to the development would be from both adjacent streets. The
subject property is in the E — Employment Zoning District.
RECOMMENDATION: Approval
EXECUTIVE SUMMARY:
This PDP complies with the following applicable requirements of the Land Use
Code L( UC), more specifically:
the process located in Division 2.2 - Common Development Review
Procedures for Development Applications of ARTICLE 2 -
ADMINISTRATION;
COMMUNITY PLANNING AND ENVIRONMENTAL SERVICES 281 N. College Ave. P.O. Box580 Fort Collins, CO80522-0580 (970)221-6750
PLANNING DEPARTMENT