Loading...
HomeMy WebLinkAboutCANYON PLACE (331 S. MELDRUM) - FDP - FDP120024 - SUBMITTAL DOCUMENTS - ROUND 1 -Plaza in-between buildings needs increase to at least 1 foot candle. Response: Refer to revised photometric plan and Alternative Compliance narrative. Comment Number: 4 Comment Originated: 11/05/2012 11/0512012: On sheet 1-1-1 in the Site Plan Information table please provide the Data for the Parking Data and Bicycle Parking and Storage. Need to verify that this project meets the new bicycle standards. Response: The bicycle numbers have been provided on the Site Plan (L1-1) Topic: Plat Comment Number: 1 11/14/2012: The boundary closes. 10/09/2012: The boundary closes. Comment Number: 3 Comment Originated: 10/09/2012 Comment Originated: 10/09/2012 11/14/2012: The reference needs to match in the sub -title, Statement of Ownership And Subdivision & Basis Of Bearings statement. The reference has been added to the sub -title. 10/09/2012: Please add reference to the original plat of Fort Collins after Block 83 in the sub -title & the Statement of Ownership And Subdivision. Response: This has been revised. Topic: Site Plan Comment Number: 40 Comment Originated: 11/14/2012 11/14/2012: Please correct the spelling of description in the legal description on sheet 1-1-1. Response: See revised Drawings. Comment Number: 41 Comment Originated: 11/14/2012 11/14/2012: There are line over text issues on sheet 1-1-1. Response: See revised Drawings. Department: Traffic Operation Contact: Ward Stanford, 970-221-6820, wstanfordna,fcgov.com Topic: Construction Drawings Comment Number: 3 Comment Originated: 10/12/2012 11/15/2012: Please describe what your plans are regarding the parking stall striping on Meldrum once the old access is closed. Unable to tell from the Utility Plans what is being considered. No striping additions/changes noted on the plans. 10/12/2012: Hoping to add parking stalls on Magnolia without removing the existing painted stalls. In doing so the new stall widths can be a little larger than typical but not smaller. Please label stall widths that vary from standard widths. Response: The dimensions of the proposed striping have been added to the Horizontal Control Plan. A note has also been included to remove and replace all striping along Magnolia. Department: Zoning Contact: Noah Beals, 970-416-2313, nbealsnn.fcgov.com Topic: General Comment Number: 3 Comment Originated: 11/05/2012 11/05/2012: In the lighting plan fixtures DID and KK are not in compliance with the Land Use Code restrictions on up -lighting see section 3.2.4 This will need to be corrected. Also loading and unloading areas require a minimum of 5 foot-candles. The proposed lighting plan for the loading/unloading area on the north side of the building is not meeting this. 4. The foodplain and flood fringe boundaries have been included on the plat, but notes should also be included to indicate that the remainder of the site is in the moderate risk floodplain. Response: A note has been added to the Plat. 5. Add a note to sheet C1.00 and C2.00 referencing the Floodplain Exhibit on sheet C4.00. Response: These notes have been revised. 6.On the Floodplain Exhibit, add "(picnic tables, bike racks, etc.)" after the word "FLOODWAY" in note 8. Response: This note has been revised. 7. Also on sheet C4.00, label the BFE's and add the datum; i.e. BFE = 4997 NGVD29. Response: The datum information has been added to the BFE's. 8. Add the elevations and datum to CSL's; i.e. 3490 4997.3 ft. NGVD29 to sheet C4.00. Response: Elevation and datum information has been added to the CSL's 9. On sheet C4.00, change the label "Existing City 100-year floodplain boundary" to "flood fringe" boundary. Response: These callouts have been revised. Comment Number: 1 Comment Originated: 10/09/2012 10/09/2012: Stormwater is ready for a public hearing. Department: Technical Services Contact: Jeff County, 970-221-6588, 'countynMcclov.com Topic: Building Elevations Comment Number: 43 11/14/2012: No comments. Topic: Construction Drawings Comment Number: 38 Comment Originated: 11/14/2012 Comment Originated: 10/10/2012 11/14/2012: There is still aline over text issue on sheet C1.00. 10/10/2012: There are line over text issues on sheet C1.00 & C2.00. Topic: Landscape Plans Comment Number: 42 11/1412012: No comments. Topic: Lighting Plan Comment Number: 29 Comment Originated: 11/14/2012 Comment Originated: 10/10/2012 11/14/2012: This has not been corrected. 10/10/2012: There are text over text & cutoff text issues on sheet E1-1. Response: See revised Drawings. Comment Number: 31 Comment Originated: 10/10/2012 11/14/2012: The sheet numbering of sheets E1.3 & E1.4 does not match the first 3 lighting sheets, which are numbered with a dash (-) not a decimal. 10110/2012: The sheet numbering of sheets E2.0 & E2.1 does not match the first 3 lighting sheets. Response: See revised Drawings. Where adequate radio coverage cannot be established within a building, public -safety radio amplification systems shall be designed and installed in accordance with criteria established by the Poudre Fire Authority. Poudre Fire Authority Bureau Admin Policy #07-01 Response: Acknowledged. Comment Number: 05 Comment Originated: 11/12/2012 11/12/2012: FIRE ALARM & DETECTION SYSTEMS In Group B occupancies having an occupant load of more than 100 persons above or below the lowest level of exit discharge, fire alarm notification appliances shall be installed and activated upon sprinkler water flow or a manual fire alarm system shall be installed. Response: Acknowledged. Comment Number: 06 Comment Originated: 11/12/2012 11/12/2012: FIRE STANDPIPE SYSTEM & FIRE PUMP Standpipe systems shall be provided in new buildings and structures in accordance with Section 905 or the 2006 International Fire Code. Approved standpipe systems shall be installed throughout buildings where the floor level of the highest story is located more than 30 feet above the lowest level of fire department vehicle access, or where the floor level of the lowest story is located more than 30 feet below the highest level of fire department vehicle access. The standpipe system shall be capable of supplying at minimum of 100 psi to the top habitable floor. An approve fire pump may be required to achieve this minimum pressure. Response: Acknowledged. Comment Number: 07 Comment Originated: 11/1212012 11/12/2012: PREMISE IDENTIFICATION New and existing buildings shall be plainly identified. Address numbers shall be visible from the street fronting the property, plainly visible, and posted with a minimum of six-inch numerals on a contrasting background. Response: Acknowledged. Department: Stormwater Engineering Contact: Wes Lamarque, 970-416-2418, wlamarouea()fcgov.com Topic: Floodplain Comment Number: 3 11/1612012: Comment Originated: 11116/2012 1. None of my previous comments regarding the drainage letter were addressed. The comments were fairly minor, but they can't be ignored. Response: Our office never received these redlines from the City and apologize that they were not addressed. We still have not received these redlines for this submittal, but can work directly with you to ensure that they are incorporated for final Mylar. 2. A site plan was not included in this submittal, so I am not sure if those previous comments were addressed. Response: Site Plan drawing 0.1 was resubmitted, but perhaps not routed to this reviewer? 3.On the plat, please change label to "flood fringe", rather than "high risk floodplain line." Response: These ca/louts have been revised. Comment Number: 1 Comment Originated: 10/12/2012 10/12/2012: Comcast has facilities on this block and relocation is a the developer's expense. This comment and diagram was provided at the staff review meeting. Contact: Don Kapperman 970-567-0245 Response: Acknowledged. Comment Number: 2 Comment Originated: 10/12/2012 10/12/2012: Larimer County Assessor is showing a different owner than the signature block shows. This comment was provided at the staff review meeting. Contact: Megan Harrity 970-498-7065 Response: Acknowledged. Applicant has contacted Megan and will ensure signature block for final mylars includes all required signatures. Department: PFA Contact: Jim Lynxwiler, 970.416-2869, pynxwiler(ftoudre-fire.org Topic: General Comment Number: 01 Comment Originated: 10/10/2012 10/10/2012: ROOF ACCESS New buildings four or more stories in height shall be provided with a stairway to the roof. Stairway access to the roof shall be in accordance with IFC 1009.12. Such stairways shall be marked at street and floor levels with a sign indicating that the stairway continues to the roof. 2006 International Fire Code 504.3 Response: Acknowledged, Comment Number: 02 Comment Originated: 10/10/2012 10/10/2012: FIRE DEPARTMENT CONNECTIONS FDC's shall be installed in accordance with NFPA standards. The location of the FDC shall be approved by the fire department. Response: Acknowledged. Comment Number: 03 10/10/2012: KNOX BOX Comment Originated: 10/10/2012 Poudre Fire Authority requires at least one key box ("Knox Box") to be mounted in approved location(s) on every new building equipped with a required fire sprinkler or fire alarm system. The top shall not be higher than 6 feet above finished floor. 2006 International Fire Code 506,1 and Poudre Fire Authority Bureau Policy 88-20 Response: Acknowledged. Comment Number: 04 Comment Originated: 11/12/2012 11/12/2012: PUBLIC -SAFETY RADIO AMPLIFICATION SYSTEM New buildings or building additions that cause the building to be greater than 50,000 square feet will require a fire department, emergency communication system evaluation after the core/shell but prior to final build out. 10/11/2012: Accessibility: State Law CRS 9-5 & ICC/ANSI A117.1-2003. Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF. Frost Depth: 30 inches. Wind Load: 100- MPH 3 Second Gust Exposure B. Seismic Design: Category B. Climate Zone: Zone 5 Energy Code Use 1. Single Family; Duplex; Townhomes: 2009 IRC Chapter 11 or 2009 IECC Chap 4. 2. Multi -family and Condominiums 3 stories max: 2009 IECC Chapter 4. 3. Commercial and Multi -family 4 stories and taller: 2009 IECC Chapter 5. Fort Collins Green Code Amendments effective starting 1-1-2012. A copy of these requirements can be obtained at the Building Office or contact the above phone number. Response: Acknowledged. Comment Number: 4 Comment Originated: 10/11/2012 10/11/2012: Canyon Place Development— project specific concerns: 1. Building code requires a 5-story office building be of Type II -A construction to achieve 5 stories. This is a 1-hour fire -rated non-combustible building. 2. Any exterior walls closer than 10 feet to the property line must provide fire -rated walls, roof parapet, and limited openings. 3. Fire -sprinkler required if more than 7000 square feet. 4. Exit stairs must provide an area of refuge. 5. Elevator must have standby power. 6. New Green Code requires: a. Exterior walls and roof must meet a STC (sound resistance) rating of 40 min. if building located within 1000ft to train tracks. b. Low -flow Watersense plumbing fixtures (toilet, faucets, shower heads) are required. c. Low VOC interior finishes. d. LEED type commissioning is required for commercial buildings 15k sq.ft. and larger. e. See Green Code compliance guide for additional requirmements. Response: All construction requirements will be as discussed in further detail at presubmittal meeting. Department: Light And Power Contact: Justin Fields, 970.224.6150, ifieldsMcaov.com Topic: General Comment Number: 8 Comment Originated: 11/13/2012 11/13/2012: Informal discussions have been held regarding easements and equipment placement and we expect that these issues will be resolved by final submittal. Response: A Utility Easement has been added to the Plat to accommodate for all existing utilities within this area.. Department: Outside Agencies Contact: Seth Lorson, 970-224-6189, slorson(7afcgov.com Topic: General cut Outs. Response: This change has been made. Comment Number: 17 Comment Originated: 11/13/2012 11/13/2012: Consider if it is feasible to reposition the parking lot entrance drive off of Canyon street to preserve a better mix of species. Response: This was not feasible. Comment Number: 18 Comment Originated: 11/13/2012 11/13/2012: Please add this tree protection note: Grading within the drip line of trees in the parkway shall be kept to a minimum. Grade to be changed not more than 1 inch near tree trunks and not more than 2 inches in the outer area under the canopy. Do not cultivate soil in preparation for planting within the drip line zone of existing parkway trees. New irrigation lines to be kept the maximum distance from the tree trunk. Proposed grading and excavation for irrigation installation within the drip line of parkway trees shall be inspected prior to work by the City Forester. Contractor is responsible to call for inspections. Response: This has been added to L1-3 Department: Internal Services Contact: Russell Hovland, 970.416.2341, rhovland fcgov.com Topic: General Comment Number: 1 Comment Originated: 10/11/2012 10/11/2012: Building Permit Pre -Submittal Meeting Pre -Submittal meetings are offered to assist the designer/builder by assuring, early on in the design, that the new commercial or multi -family projects are on track to complying with all of the adopted City codes and Standards listed below. The proposed project should be in the early to mid -design stage for this meeting to be effective and is typically scheduled after the Current Planning conceptual review meeting. Applicants of new commercial or multi -family projects are advised to call 416-2341 to schedule a pre -submittal meeting. Applicants should be prepared to present site plans, floor plans, and elevations and be able to discuss code issues of occupancy, square footage and type of construction being proposed. Response: Presubmittal meeting held with Russ Hovland on 1210512012. Comment Number: 2 Comment Originated: 10/11/2012 10/11/2012: Construction shall comply with the following adopted codes as amended: 2009 International Building Code (IBC) 2009 International Residential Code (IRC) 2009 International Energy Conservation Code (IECC) 2009 International Mechanical Code (IMC) 2009 International Fuel Gas Code (IFGC) 2009 International Plumbing Code (IPC) as amended by the State of Colorado 2011 National Electrical Code (NEC) as amended by the State of Colorado Response: Acknowledged, Comment Number: 3 Comment Originated: 10/11/2012 • Contact the City Forester to inspect all street tree plantings at the completion of each phase of the development. All trees need to have been installed as shown on the landscape plan. Approval of street tree planting is required before final approval of each phase. Comment Number: 9 Comment Originated: 10/09/2012 10/09/2012: Please add the tree protection specifications found in 3.2.1 G Response: See Sheet L 1-3. Comment Number: 10 Comment Originated: 11/13/2012 11/13/2012: Please add tree protection and mitigation information identified during the onsite meeting with the City Forester. Response: See Sheet L 1-3. Comment Number: 11 Comment Originated: 11/13/2012 11/13/2012: Please add additional standard landscape notes that can be obtained from the City Project Planner. These can address such topics as mulch, edging, type of irrigation, plant quality etc. Response: See Sheet L1-2 Comment Number: 12 Comment Originated: 11/13/2012 11/13/2012: Please add this note. Tree pruning and removal work shall be done by a Fort Collins licensed arborist. Prior to pruning existing street trees to provide clearance for the construction of the building, contact the City Forester. Pruning of City street trees to be approved by the City Forester and performed by a licensed and certified arborist. Response: See Sheet L1-3. Comment Number: 13 Comment Originated: 11/13/2012 11/13/2012: Position the location of the edge of the planting beds in the parkway well away from tree trunks. Keep new shrubs and perennials as least 6 feet from the tree trunks. Use 1 gallon size plants with less density near trunks and in the root zone on existing trees. Response: Shrubs have been removed from these areas. Comment Number: 14 Comment Originated: 11/13/2012 11/13/2012: Are tree grates to be used around any of the new trees in the parkway? If so note and specify. Response: See Site Plan Sheet L1-1 Comment Number: 15 Comment Originated: 11/13/2012 11/13/2012: Please provide tree species diversity for new trees as described in 3.2.1 D 3. list percentages in the plant schedule. Response: See Sheet L1-2 Comment Number: 16 Comment Originated: 11/13/2012 11/13/2012: Using Skyline Honeylocust is probably the best choice for street trees in sidewalk number of upsized trees. Upsized trees as follows. The city Forester can provide the number of mitigation trees at the on -site meeting. Response: We have prepared a Tree Mitigation plan (Sheet L1-3) Canopy Shade Tree- 3.0 inch caliper Ornamental Tree- 2.5 inch caliper Conifer Tree- 8 feet height. Comment Number: 3 Comment Originated: 10/09/2012 1010912012:The final landscape and tree protection plan will need to identify all exiting trees as to size, condition and type with intent to save, remove or transplant. Response: See Sheet L 1-3. Comment Number: 4 Comment Originated: 10/09/2012 10/09/2012: Please list trees and other landscape plants as to size, quantity and percentage used in the plant schedule. Response: See Sheet L1-2. Comment Number: 5 Comment Originated: 10/09/2012 10/09/2012: Please provide tree species diversity as described in 3.2.1 D See Response: Sheet L1-2 Comment Number: 6 Comment Originated: 10/09/2012 10/0912012: Please keep new shrubs at least 5-6 feet away from existing street trees to prevent root damage at planting. Response: We revised our plans to remove shrubs under existing street trees. Comment Number: 7 Comment Originated: 10/09/2012 10/09/2012:Consider using Hotwings Tatadan Maple in place of Amur Maple as it is similar and does better in the Fort Collins environment. Response: We made this change. Comment Number: 8 Comment Originated: 10/09/2012 10/09/2012: Please add standard landscape notes including the following. Response: We added these notes. • The soil in all landscape areas, including parkways and medians, shall be thoroughly loosened to a depth of not less than eight (8) inches and soil amendment shall be thoroughly incorporated into the soil of all landscape areas to a depth of at least six (6) inches by tilling, discing or other suitable method, at a rate of at least three (3) cubic yards of soil amendment per one thousand (1,000) square feet of landscape area. Exception within the drip line of any existing tree. • A permit must be obtained from the City forester before any trees or shrubs as noted on this plan are planted, pruned or removed on the public right-of-way. This includes zones between the sidewalk and curb, medians and other city property. This permit shall approve the location and species to be planted. Failure to obtain this permit may result in replacing or relocating trees and a hold on certificate of occupancy. be located within the site boundaries and may not exist in the public right of way. Response: The fountain has been relocated inside the property line but is still in the public plaza. Comment Number: 8 Comment Originated: 10/10/2012 11/13/2012: The stone benches will need to be shown on the plans with a callout on the plans similar to "Final fountain location to be determined by separate revocable encroachment permit, location not approved per this plan." 10/10/2012: Stone benches cannot be approved in the Right of Way as a part of these plans. A separate encroachment permit will need to be submitted and reviewed after these plans have been approved. Benches should be positioned as to leave a clear and consistent path for the sidewalk without pedestrians needing to change direction to avoid them. Response: This note has been added to the Site Plan "Final bench location to be determined by separate revocable encroachment permit, location not approved per this plan." Comment Number: 10 Comment Originated: 10/10/2012 11/1312012: Further discussion with staff has eliminated the need for scoring or banding between the different materials. However, Concrete will need to be 6 inches thick within right of way and a not or callout needs to be added to plans. 10/10/2012: Concrete in the right of way will need to be 6 inches thick. Scoring, banding or different materials should be used along the right of way line to delineate the concrete that is in the right of way and the concrete outside of the right of way. Response: A note has been added to the Site Plan that concrete paving in the ROW will be a minimum of 6 inches thick. Department: Environmental Planning Contact: Lindsay Ex, 970-224-6143, lex cDfcgov.com Topic: General Comment Number: 1 Comment Originated: 10/10/2012 10/10/2012: No comments. Department: Forestry Contact: Tim Buchanan, 970-221-6361, tbuchananot7.fcgov.com Topic: Landscape Plans Comment Number: 1 Comment Originated: 10/09/2012 10/09/2012: The applicant should contact the City Forester for an on -site meeting to evaluate construction impact to existing trees and to determine mitigation for trees that will be removed. Hardscape placement around existing City street trees will need to be closely reviewed. Shrub bed placement and edging around existing City street trees will also need to be evaluated. Response: We met with the City Forester on 11108112 and have prepared a "Tree Mitigation Plan" (Sheet L1-3) to address comments. We have also made revisions to the Planting Plan (L1-2) based on these comments as well. Comment Number: 2 10/09/2012: Comment Originated: 10/09/2012 Removed trees will need to be mitigated as discussed in 3.2.1 F by planting the required Comment Number: 20 Comment Originated: 11/14/2012 11/14/2012: Sheet C3.00 -Thank you for providing sidewalk chases to minimize drainage from a private driveway. However, please design, construct and provide details per City of Fort Collins standard sidewalk chases. Verify with Stormwater the width of the sidewalk chase. Response: The sidewalk chase to the north has been revised to the standard 2' width as shown within the details. However, the sidewalk chase to the south is still shown at a 1' width as a small area is draining to this location. Topic: General Comment Number: 1 Comment Originated: 10/10/2012 11/13/2012: Applicant acknowledges this comment and requirement and will work with City Staff as their plans progress. 10/10/2012: The planning objectives indicated that a basement is proposed for the building. Consideration of the design and construction in relation to the property lines/right of way lines must be taken into account. No tie backs, footings or structures (permanent or temporary) are to encroach onto or into public right of way or utility easements. Comment Number: 16 Comment Originated: 10/10/2012 11/13/2012: Please add a note to final plans explaining that if any walk is removed or damaged that it will need to be replaced with 5' min. width sidewalk. 10/10/2012: All sidewalk that is removed and replaced per the construction plans or during construction must be constructed to a minimum width of 5' per commercial local standards. Response: This note has been added to the Site Plan drawing and sheet HC1. Topic: Plat Comment Number: 4 Comment Originated: 10/10/2012 11/13/2012: Per the utility coordination meeting, applicant was going to contact XCEL energy and Fort Collins Light and Power to discuss their specific needs. Does the plat provided with this submittal represent these discussions? 10/10/2012: Additional easements may need to be proposed for existing utilities that will no straddle the new lots as well as any proposed easements needed for the development. A utility coordination meeting can be set as early as the next couple of weeks if applicant desires. Response: A Utility Easement has been added to the Plat to accommodate for all existing utilities within this area. Topic: Site Plan Comment Number: 6 Comment Originated: 10/10/2012 11/13/2012: What is the height of the Stucco wall adjacent to the sidewalk? Is it 6' at this location or is stepped down? 10/10/2012: Ensure that site distance can be achieved at the proposed driveway approach onto Canyon Avenue. The site plan indicates a stucco wall adjacent to the access drive and it shall not obstruct drivers view of sidewalk. Response: The site line distance is shown on the plans and the 6' wall does not encroach upon it. Comment Number: 7 Comment Originated: 10/10/2012 11/13/2012: The fountain will need to be shown on the plans with a callout on the plans similar to "Final fountain location to be determined by separate revocable encroachment permit, location not approved per this plan." 10/10/2012: The proposed fountain along West Magnolia needs to at 20% enclosed and 80% fixed. Response: The bicycle numbers have been added to L1-1. Comment Number: 9 Comment Originated: 11/15/2012 11/15/2012: The site plan notes that the project is in the NCB zone district when it is actually in the D - Downtown (Canyon Avenue Subdistrict) zone district. Please revise. Response: We have changed this label. Department: Engineering Development Review Contact: Andrew Gingerich, 970-221-6603, agingerich anfcgov.com Topic: Construction Drawings Comment Number: 15 Comment Originated: 10/10/2012 11/13/2012: Ensure that Handicap Ramp details are included on final submittal. 10/10/2012: Sheet C2.00 - Sidewalk and handicap ramp will need to be removed and replaced to standard 5' in width and ramp will need to be constructed to most current ADA standards in the proximity of the sanitary sewer service. Response: The sanitary sewer has been rerouted, but a handicap ramp detail has still been provided. This detail is still pertinent to the proposed handicap ramp located at the northeast corner of the project. Comment Number: 17 Comment Originated: 10110/2012 1111312012: With the assumption that the Civil Plans are showing the correct configuration of the Driveway onto Canyon Avenue, Site & Landscape Plans need to have the driveway radiuses revised. 10110/2012: Sheet C3.00 Driveway curb return radius onto Canyon Avenue does not appear to be consistent with site plan. Please label the radius size. The radius appears to be much larger than what is allowed per the standard driveway details for a type I as indicated on the plans. Response: The drawings have been updated and the correct base is currently shown. Comment Number: 19 Comment Originated: 10/10/2012 11/13/2012: On the final plans please include a striping plan on an existing sheet or add a sheet for striping, include dimensioning from stop signs and crosswalks. 10/1112012: Per Discussions with Transportation and Parking Services staff a handicap space will be required on each end of the block face (East and West end of Magnolia, South end of Meldrum). Additionally, parking spaces may not exist within 20' of a cross walk and 30' from a stop sign on the approach. Please revise parking striping plan. Contact Randy Hensly (416-2058) for additional details. 10/10/2012: Sheet C3.00 - Provide detail and delineate between existing and proposed parking spaces and how the striping will match between the two. Contact Randy Hensley in parking services (416-2058) to discuss downtown parking requirements and if additional handicap spaces are needed adjacent to your building. If handicap spaces are required then depending on their location additional ADA access ramps may be required along the street frontage to provide access to the building. Response: The dimensions of the proposed striping have been added to the Horizontal Control Plan. A note has also been included to remove and replace all striping along Magnolia. functionality of the parkway. If accent shrub planting is desired, there is an opportunity at the corner for accent planting - it's more sunny, and appears due for replacement of the current landscaping. Response: As per prior comment and discussions with the City Forester we have removed the shrub beds adjacent to the street and underneath the mature trees along Magnolia St and Meldrum St within the project boudary. We have added sod in its place. Department: Current Planning Contact: Seth Lorson, 970-224-6189, slorson(.fcgov.com Topic: General Comment Number: 2 Comment Originated: 10/1212012 10/12/2012: Staff is discussing the proposal for the fountain in the ROW and will contact you as soon as we have a determination. Response: We have relocated the fountain further north and inside the future public plaza and out of the ROW. Topic: Lighting Plan Comment Number: 5 Comment Originated: 11/13/2012 11/13/2012: The DID and KK fixtures are oriented upward. Please see LUC L.2.4(D). Also, some of the DID fixtures are in the ROW. This can be added to the greater conversation regarding improvements in the ROW. Response: Refer to revised photometric plan and Alternative Compliance narrative. Comment Number: 10 Comment Originated: 11/16/2012 11/16/2012: As discussed, please submit a request and evidence for alternative compliance for the site lighting standards per LUC Sec. 3.2.4(E). Response: Refer to revised photometric plan and Alternative Compliance narrative. Topic: Plat Comment Number: 8 Comment Originated: 11/13/2012 11/13/2012: The signature block for planning should be titled "DIRECTOR OF COMMUNITY DEVELOPMENT AND NEIGHBORHOOD SERVICES". This does not have to be done prior to Final Plan. Response: This has been revised. Topic: Site Plan Comment Number: 6 Comment Originated: 11/13/2012 11/13/2012: Please label the "public plaza" element on the plan as required in LUC 4.16(E)(1) (c). Response: We have added this label. Comment Number: 7 Comment Originated: 11/13/2012 11/13/2012: Please provide parking data and bicycle parking data. Bicycle parking is required 1 space per 4,000 square feet = 54,000 s.f. / 4,000 = 13.5 spaces. These need to be provided Fort Collins Community Development and Neighborhood services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224,6134 - fax fcgov. com/developmentreview November 16, 2012 Steve Schroyer Blue Ocean Enterprises 416 W. Oak St. Fort Collins, CO 8521 RE: Canyon Place (331 S. Meldrum), PDP120023, Round Number 2 Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Seth Lorson, at 970-224-6189 or slorson@fcgov.com. Comment Summary: Department: Advance Planning Contact: Clark Mapes, 970.221.6225, cmapes(o)fcgov.com Topic: General Comment Number: 2 Comment Originated: 11/13/2012 11/13/2012: Where the plaza encroaches across the right-of-way, a continuous clear direct sidewalk path should be maintained to continue the fabric and pattern of the sidewalk system in the area. Any features such as benches and a fountain should be located accordingly. Tree cutouts in the plaza should be 6x6', not 44% for tree health. Response: The fountain has been relocated so there is a clear path for the walkway. We will work to incorporate larger tree grates (5x5 or larger) as we address the final paving design. Topic: Landscape Plans Comment Number: 1 Comment Originated: 11/13/2012 11/13/2012: Standards allow for either turf grass or ground cover plantings in the parkway. However, the parkways currently have turf and large trees, which are well established and highly functional in this high -activity area. It appears that the best solution is to retain this existing parkway landscaping. The landscape plan appears to show shrub planting underneath existing large trees. This could be disruptive for the trees, the shrubs could reduce the