HomeMy WebLinkAboutWEST RANGE FORT COLLINS - PDP - PDP120028 - CORRESPONDENCE - (5)The area along une west property line, north of the plaza, ino, rites lighting levels that exceed 0.1 foot candle (ranging from 0.3 — 0.7 foot candle) and appears to be a result of the two 20' tall lights in the parking area, along the west property line. The maximum 0.1 foot candle level must be attained at no more than 20' into the adjacent site, since the adjacent use (sorority) is considered a residential use under the Land Use Code. Topic: Site Plan Comment Number: 7 Since the proposed fraternity use is not affiliated with CSU at this time, the fraternity use must be deleted from the application and the project will become a multi -family development. Given the proposed density of less than 24 DU/acre, the project can be a Type 1 review. Comment Number: 8 Comment Originated: 11/13/2012 A wall is proposed along the west property line of the site plan and construction plans show this as a concrete wall. Please add the proposed height and description or sketch of the wall design, as well as indicate the extent of the wall along the west property line. A maximum height of 6' is permitted in the rear or side yard, and 4' is the maximum height in a front yard between the front building line and property line. Comment Number: 9 Comment Originated: 11/13/2012 The site plan notes "enhanced paving" on one of the parking areas. - Please provide a description of this proposed treatment. Comment Number: 10 Comment Originated: 11/13/2012 Additional information is needed on how the enclosed bicycle parking area is intended to function. Also, the bike rack shown in the sidewalk along Meldrum Street should be provided closer to an entrance or in an area that is more functional. Comment Number: 11 Comment Originated: 11/13/2012 The proposed height and materials of the trash enclosure must be provided. Also, please show how the collection and storage of recyclables will be addressed. Comment Number: 12 Comment Originated: 11/13/2012 The site plan notes that rooftop mechanical equipment will be screened. Please clarify how this will be accomplished. Comment Number: 13 Comment Originated: 11/13/2012 Section 3.2.3 addresses solar access, orientation and shading and requires that the right to solar access be protected and that elements of the site plan (building) not cast a shadow onto structures on the adjacent property that would be greater than the shadow of a 25' high wall located along the property line, between 9:00 AM and 3:00 PM on December 21. Please provide information to evaluate this requirement. Department: Building Inspection — see attached information sheet. Reviewer: COMCAST — Need to redo line to fee new building. At this time the .,ay has no proof of the Fraternity's affiliation ..,,h Colorado State University, therefore the applicant will need provide such proof. Comment Number: 2 Comment Originated: 10/31/2012 10/31/2012: 3.2.2(L)Table A and B Drive aisle width for two way traffic is a minimum of 24' this includes the egress/ingress. The east entry into the parking area needs to increase in width to 24'. Comment Number: 3 Comment Originated: 11/14/2012 11/14/2012: The lighting plan shows foot-candles less than 1 in some of the parking area. These areas need to be brought up to at least 1 foot-candle. Comment Number: 4 Comment Originated: 11/14/2012 11/14/2012: The trash enclosure is required to be designed with walk-in access without having to open the main service gate. Please show the walk-in access on the site plan and provide elevations of the enclosure. Department: Current Planning Contact: Sherry Albertson -Clark, 970-224-6174, salbertson-clark@fcgov.com Topic: Building Elevations Comment Number: 1 Comment Originated: 11/13/2012 The Building and Project Compatibility Standards (Section 3.5.1) of the Land Use Code require that the physical and operational characteristics of proposed buildings be compatible within the context of the surrounding area. These standards address architectural character; building size, height, bulk, mass, scale; privacy; building materials; building color; mechanical equipment; and operational/physical compatibility. The east elevation along Meldrum Street is the longest elevation and the one that would be most visible from the adjacent streets. Of concern to staff is the length of this elevation, as well as the parking below the 2nd story, which will be visible along Meldrum Street. Comment Number: 2 Comment Originated: 11/13/2012 Several of the elevations appear to have the labels for brick and stucco switched (as compared to the graphic symbol used). Comment Number: 3 Comment Originated: 11/13/2012 Building colors need to be added to the architectural elevations. Topic: Landscape Plans Comment Number: 4 Comment Originated: 11/13/2012 Shrub beds must be delineated and drawn to scale with dimensions; and the extent and location of all plant materials and quantities and type (deciduous vs. evergreen) shown so that compliance with Section 3.2.1 of the Land Use Code can be evaluated. Comment Number: 5 Comment Originated: 11/13/2012 Screening of the parking area visible along Meldrum Street requires a fence, wall, planter, berm, plant material or a combination at least 30" high and extending at least 70% of the length of the frontage of the parking area. As currently designed, the required screening does not appear to have been accomplished. A section showing the proposed screening will also be needed. Topic: Lighting Plan Comment Number: 6 Comment Originated: 11/13/2012 .;omment Originated: 11/14/2012 Comment Number. 20 11/14/2012: Please label all right of way widths. Topic: Site Plan Comment Number: 21 11/14/2012: There are line over text issues on sheet 2. Department: Traffic Operation Contact: Ward Stanford, 970-221-6820, wstanford@fcqov.com Topic: Construction Drawings Comment Number: 1 Comment Originated: 11/14/2012 Comment Originated: 11/15/2012 11/15/2012: Just for verification, this project is not expecting to change the current on -street parking layout on Meldrum correct? Topic: Landscape Plans Comment Number: 2 Comment Originated: 11/15/2012 11/15/2012: Looks like there will be sight triangle issues with the Red Baron Crabapple trees planted between the two alley accesses. The problem looks greater at the east access but both look to be problematic. Per review of Crab pictures on the internet they look to have a low habit and may not be the correct choice for the location. Please review for access sight triangle requirements. Topic: Traffic Impact Study Comment Number: 3 11/15/2012: The TIS is accepted. Comment Originated: 11/15/2012 Department: Water -Wastewater Engineering Contact: Roger Buffington, 970-221-6854, rbuffington@fcgov.com Topic: Construction Drawings Comment Number: 1 Comment Originated: 11/13/2012 11/13/2012: Show all existing water and sewer services and add appropriate notes on the abandonment of any services that will not be used for the proposed project. Unused services to be abandoned at the main. Comment Number: 2 Comment Originated: 11/13/2012 11/13/2012: See redlined utility plans for additional comments. Department: Zoning Contact: Noah Beals, 970-416-2313, nbeals@fcgov.com Topic: General Comment Number: 1 Comment Originated: 10/31/2012 10/31/2012: Land Use Code (LUC) 5.1.2 Fraternity and sorority houses shall mean residences housing students in organizations established primarily to promote friendship and welfare among the members (i.e., Greek -letter social fraternities and similar organizations), and which residences are affiliated with Colorado State University. plat. Comment Number: 5 Comment Originated: 11/14/2012 11/14/2012: There are line over text issues on sheet C1.00. Comment Number: 6 Comment Originated: 11/14/2012 11/14/2012: Please change the West Laurel Street right of way on all sheets to "varies". See the subdivision plat for more information. Topic: Landscape Plans Comment Number: 7 Comment Originated: 11/14/2012 11/14/2012: There are line over text issues on sheet 3. Topic: Lighting Plan Comment Number: 8 Comment Originated: 11/14/2012 11/14/2012: There are line over text & text over text issues on sheet 5. Topic: Plat Comment Number: 9 Comment Originated: 11/14/2012 11/14/2012: The boundary & legal description close. Comment Number: 10 Comment Originated: 11/14/2012 11/14/2012: Please add "A Part Thereof' & "And A Portion Of Lot 6" to the sub -title. Comment Number: 11 Comment Originated: 11/14/2012 11/14/2012: Please add the Sight Distance Restrictions statement. Comment Number: 12 Comment Originated: 11/14/2012 11/14/2012: Is the Arthur Ditch easement new or existing? If it is existing, please provide a reception number. If it is new, please add an Easement Dedication for the Arthur Ditch. Comment Number: 13 Comment Originated: 11/14/2012 11/14/2012: Are there any lienholders of this property? If so, please add the Lienholder signature block. Comment Number: 14 Comment Originated: 11/14/2012 11/14/2012: Please add "and it's southerly extension" to the Basis Of Bearings statement. Comment Number: 15 Comment Originated: 11/14/2012 11/14/2012: Please add a note #3 referencing the agreement the City & CSU have for the right of way of Laurel Street. If more information is needed please call. Comment Number: 16 Comment Originated: 11/14/2012 11/14/2012: Please make the found monument symbols the same size in the legend & on the boundary. Comment Number: 17 Comment Originated: 11/14/2012 11/14/2012: Please clearly label the sight distance easements. Comment Number: 18 Comment Originated: 11/14/2012 11/14/2012: Please make sure that all distances are clearly defined. Comment Number: 19 Comment Originated: 11/14/2012 11/14/2012: Please describe & tie the southeast corner of Block 86 or remove it. beneath other groups. Exception: Enclosed parking garages located beneath Group R3 occupancies. 2006 International Fire Code 903.2.9 & 903.2.9.1 Comment Number: 3 Comment Originated: 11/13/2012 11/13/2012: FIRE ALARM SYSTEMS -GROUP R-2 A manual fire alarm system shall be installed in Group R-2 (residential) occupancies where any dwelling unit is located three or more stories above the lowest level of exit discharge and where the building contains more than 16 dwelling units. Your current plan of 15 units and 2-stories does not trigger this need however, should the number of dwelling units increase, a manual alarm system may be required. 2006 International Fire Code 907.2.9 Comment Number: 4 Comment Originated: 11/13/2012 11/13/2012: FDC Fire Department Connections shall be installed in accordance with NFPA standards. The location of the FDC shall be approved by the fire department. 2006 International Fire Code 912.2 Comment Number: 5 Comment Originated: 11/13/2012 11/13/2012: KEY BOXES REQUIRED Poudre Fire Authority requires at least one key box ("Knox Box") to be mounted in approved location(s) on every new building equipped with a required fire sprinkler or fire alarm system. The top shall not be higher than 6 feet above finished floor. 2006 International Fire Code 506.1 and Poudre Fire Authority Bureau Policy 88-20 Comment Number: 6 Comment Originated: 11/13/2012 11/13/2012: PREMISE IDENTIFICATION New and existing buildings shall be plainly identified. Address numbers shall be visible from the street fronting the property, plainly visible, and posted with a minimum of six-inch numerals on a contrasting background. 2006 International Fire Code 505.1 Department: Technical Services Contact: Jeff County, 970-221-6588, jcounty@fcgov.com Topic: Building Elevations Comment Number: 1 Comment Originated: 11/14/2012 11/14/2012: There are line over text issues on sheets 7 & 8. Topic: Construction Drawings Comment Number: 2 Comment Originated: 11/14/2012 11/14/2012: Please change the sub -title on sheet C0.00 to match the subdivision plat. Comment Number: 3 Comment Originated: 11/14/2012 11/14/2012: The description for benchmark CSU2 does not match the City's published description. Please change this on all sheets. Comment Number: 4 Comment Originated: 11/14/2012 11/14/2012: The Basis Of Bearings statement on sheet C0.00 does not match the subdivision Comment Number: 2 Comment Originated: 11/13/2012 11/13/2012: Please add the following as a tree protection notes: All tree pruning and removal work shall be performed by a City of Fort Collins licensed arborist as required by code. Prior to grading or excavation with in the drip line zone of any existing tree contact the City Forester. Contractor is responsible to schedule inspections. Comment Number: 3 11/13/2012: The condition of tree #4 is poor. Department: Light And Power Contact: Rob Irish, 970-224-6167, rirish@fcgov.com Topic: General Comment Number: 1 Comment Originated: 11/13/2012 Comment Originated: 11/14/2012 11/14/2012: Will this site require any 3-phase power? 3-phase or 1-phase power will require system modifications with 3-phase being more problematic. Owner will be responsible for system modification charges. Comment Number: 2 Comment Originated: 11/14/2012 11/14/2012: The existing electric vault shown on the utility plan will need to be replaced with an oval vault or a switch cabinet. An oval vault maybe preferred due to the sight distance easement. This is something that cannot be driven over. Comment Number: 3 Comment Originated: 11/14/2012 11/14/2012: The proposed electric line and transformer will need to be in a utility easement. Comment Number: 4 Comment Originated: 11/14/2012 11/14/2012: Owner will be responsible for Electric Capacity Fees, Building Site charges and system modification charges for this development. Comment Number: 5 Comment Originated: 11/14/2012 11/14/2012: Relocate the proposed electric line to the West drive entrance so it's not located under the second story of the building. Department: PFA Contact: Jim Lynxwiler, 970-416-2869, Ilynxwiler@poudre-fire.org Topic: General Comment Number: 1 Comment Originated: 11/13/2012 11/13/2012: This building will require an automatic fire sprinkler system under a separate permit. Comment Number: 2 Comment Originated: 11/13/2012 11/13/2012: AUTOMATIC SPRINKLER SYSTEM An automatic sprinkler system shall be provided throughout buildings classified as enclosed parking garages (Group S-2 occupancy) in accordance with IBC 406.4 OR where located Comment Number. 5 Comment Originated: 11/14/2012 11/14/2012: Please revise General Note #34 to reference the City of Fort Collins Comment Number: 6 Comment Originated: 11/14/2012 11/14/2012: Construction details were not included in the plan set with this submittal. Comment Number: 7 Comment Originated: 11/14/2012 11/14/2012: Proposed utility plan and profiles were not included in the plan set with this submittal. Comment Number: 8 Comment Originated: 11/14/2012 11/14/2012: The site plan shows (2) trees in the sight distance easement. Please note that landscaping within the sight distance easement shall not exceed 24 inches in height. Topic: Plat Comment Number: 9 Comment Originated: 11/14/2012 11/14/2012: Please add the Sight Distance Easement Restrictions language to the plat- contact me for an updated copy of this language. Comment Number: 10 Comment Originated: 11/14/2012 11/14/2012: Arthur Ditch representatives will need to sign the plat for the easement dedication. Comment Number: 11 Comment Originated: 11/14/2012 11/14/2012: This submittal is not dedicating the standard 9 foot utility easement along the east boundary of the property. If you are not dedicating this easement then approval from utility owners must be confirmed prior to final approval of the plat. Comment Number: 12 Comment Originated: 11/14/2012 11/14/2012: Please add our standard note to the plat- "There shall be no private conditions, covenants or restrictions that prohibit or limit the installation of resource conserving equipment or landscaping that are allowed by Sections 12-120—12-122 of the City Code." Comment Number: 13 Comment Originated: 11/14/2012 11/14/2012: The drainage easement boundary is not clear. Please identify the boundary with arrows on the plat. Department: Environmental Planning Contact: Lindsay Ex, 970-224-6143, lex@fcgov.com Topic: General Comment Number: 1 Comment Originated: 11/13/2012 11/13/2012: No comments. Department: Forestry Contact: Tim Buchanan, 970-221-6361, tuchanan@fcgov.com Topic: Landscape Plans Comment Number: 1 Comment Originated: 11/13/2012 11/13/2012: Please add this sentence to Landscape note #14: To protect existing trees from root damage do not cultivate more than 2 inches deep within the drip line zone of existing trees. City of .For°t Collins /O ", Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax kgov. com/developmentreview November 15, 2012 Brent Cooper Ripley Design, Inc. 401 W. Mountain Ave., Suite 100 Fort Collins, CO 80521 RE: West Range Fort Collins, PDP120028, Round Number 1 Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Sherry Albertson -Clark, at 970-224-6174 or salbertson-cark@fcgov.com. Comment Summary: Department: Engineering Development Review Contact: Tyler Siegmund, 970-221-6501, tiegmund@fcgov.com Topic: General Comment Number: 1 Comment Originated: 11/14/2012 11/14/2012: A temporary construction easement/agreement from the adjacent property owner will be required for the concrete wall construction on the west property line. Comment Number: 2 Comment Originated: 11/14/2012 11/14/2012: It is the developer's responsibility to improve the frontage along the property including repairs to damaged curb, gutter and sidewalk. We understand that this may be difficult along Arthurs Ditch and we will work with you on alternatives for the repairs identified over the ditch. Comment Number: 3 Comment Originated: 11/14/2012 11/14/2012: You may want to think about shoring any excavations that could. potentially impact Arthurs Ditch. Comment Number: 4 Comment Originated: 11/14/2012 11/14/2012: Please update General Note #5