HomeMy WebLinkAboutARCADIA AT WILLOX LANE - FDP - 5-05B - CORRESPONDENCE -FINAL PLAN
REVISION COMMENT
Citvof Fort Collins
SHEET
DATE: January 10, 2007
C R-
�M: Park Planning
1b : PROJECT PLANNER: Ted Shepard
#5-05B ARCADIA PDP — FINAL PLANS
SECOND ROUND OF FINAL PLAN REVIEW
Please return all comments to the project planner no later than the staff
review meeting:
January 31, 2007
Note -.Please identify your redlines for future reference
No Problems
RECEIVED
JAN 18 2007
/) ® Problems or Concerns (see below, attached, or DMS)
/�✓%��s //✓%�'r /`�U��1R, � �I %�� �%!�� It^2-,��/�%.f/ S�„C �r " Pw6lLc /�IGQ.iS
�. G� GJ✓r T � r/ LCQ %zo /L.t.O✓ l! D 11 ��LZ `S (fir s/ DV �':�1 bL1(,� 2GYd SJ jj�c QQt r/�
� /
Chet ve,�u-� 11-2,1407
Name (please print)
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
kPlat _Site _Drainage Report _Other 4i'��!
kutility _Redline Utility _Landscape City of Fort Collins
Number: 127 Created: 2/2/2007
[2/2/07] At intersection of Shortline and Barn Door, the sanitary sewer passes over storm
sewer "F"; therefore, steel casing is not needed on the sanitary. Switch casing to the water
main which is below the storm sewer.
Number:128 1 Created: 2/2/2007
[2/2/07] If there is interest in using PVC for water main, additional notes and details will
need to be added to the plans.
Number: 129 Created: 2/2/2007
[2/2/07] Add air release valve near west end of 12" water main in Willox.
Number: 130 Created: 2/2/2007
[2/2/07] See plans for other comments.
Comments from Current Planning:
No major comments. Please see redlines for minor comments.
If you have any questions regarding these issues or any other issues related to this project,
please feel free to call me at (970) 221-6750.
Another formal round of review will not be necessary. Please submit paper revisions to
each department individually prior to submitting signed final mylars.
Since:
T
Ted Shepard
Chief Planner
Page 4
Topic: Detention Pond Maintenance
Number: 95 Created: 9/19/2006
[1/30/07] Agreement will need to be finalized prior to plan signature.
[9/19/06] Has there been an agreement with the Parks department regarding the
maintenance of the pond?
Topic: Grading Plan
Number: 97 Created: 9/19/2006
(1/30/07] Call out all high point elevations on lots.
[9/19/06] Please provide FF elevation and detailed spot elevations on the grading plans.
How will the proposed retaining wall be built along the property line? If construction would
affect neighboring property to the north and east, then a construction easement may be
needed.
Please add notes that no grading shall be done on neighboring properties.
Topic: Water Line Boring
Number: 100 Created: 9/19/2006
[1/30/07] _
(9/19/06] The boring of the water line under the railroad track will necessitate a license
agreement with the railroad company. The agreement that was submitted had the private
owners as the licensee, but since the City will own maintain and operate that line, the
license should have the City as the beneficiary of that license agreement.
The crossing of that water line with the existing sanitary line should be potholed now during
the design phase.
Topic: Water Plans
Number: 101 Created: 9/19/2006
[1/30/07]
[9/19/06] Please identify clearly City of Fort Collins lines and Northern Colorado Water
district line on the plans. The district line may have some conflict with the proposed trees in
the Willox Lane right of way.
Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington
Topic: WaterlWastewater
Number: 108 Created: 9/21 /2006
[2/2/07] Correct valve reference locations.
[9/21/06] Revise the valving on the water mains as noted on the redlined plans.
Number: 126 Created: 2/2/2007
[2/2/07] Add detail for the insulation over the sewer including the insulation specification (we
have manufacturer's info), and provide thickness design calculations for the insulation.
Page 3
Number: 123 Created: 1 /31 /2007
[1/31/07] Vertical curve data is missing for the Right Flow Line profile for Shortline rd. on
sheet 26.
Number: 124 Created: 1 /31 /2007
[1/31/07] Refer to sheet 30, Willox Lane Ultimate design. The proposed flow line elevation
at the bridge crossing is shown lower than the existing grade. You will need to show the box
culvert on the plans and provide the dimension for clearance below the proposed profile
elevation.
Number: 125 Created: 1 /31 /2007
[1/31/07] Please include additional elevation, cross slope and dimension information on the
T- intersection details on sheet 34 per LCUASS 7-27.
Department: Transportation Planning Issue Contact: Kurt Ravenschlag
Topic: General
Number: 37 Created: 1 /17/2006
[1/29/07] The plans still show a 5' wide walk along the eastern side of Hay'Bale Lane.
Please expand the width to 8' from the point at which the trail intersects the street north to
the pedestrian ramp at Willox. See redlines for detail.
[1/17/06] Section of trail that connects to the existing trail in Soft Gold Park must be
concrete from trail connection to the sidewalk along Willox.
Department: Transportation Planning Issue Contact: David Averill
Topic: Zoning
Number: 114 Created: 1 /29/2007
[1/29/07] There are some overlapping labels within tract C that make it hard to read
easements/dimensions/notes/etc (site plan, sheet 2). Please rectify.
Department: Stormwater-Water-Wastewater Issue Contact: Basil Hamdan
Topic: Details
Number: 131 Created: 2/2/2007
[2/2/07] Please provide details for the water quantity and quality outlet control plates and
detention pond spillways for all ponds on the plans.
Please specify which pan detail is being used at different locations.
Please label detention pond numbering on drainage plan and specify all spillway locations
reinforcement and size.
See plans for additional comments.
Topic: Detention on City Parks property.
Number: 93 Created: 9/19/2006
[1 /30/07]
[9/19/06] Agreement with the Parks Department should be provided regarding the proposed
work on the parks property.
Page 2
u,
STAFF PROJECT REVIEW
Cityof Fort Collins
MICHAEL CHALONA Date: 02/05/2007
LAND IMAGES, INC
1136 E. STUART #2040
FORT COLLINS, CO 80525
Staff has reviewed your submittal for ARCADIA PDP - TYPE II AND FINAL PLANS, and we
offer the following comments:
Department: Engineering Issue Contact: Randy Maizland
Topic: Engineering
Number: 115 Created: 1 /30/2007
(1/30/07] General - Please correct all line -over -text conflicts, overlapping text for scanability.
See redlines for clarification.
Number: 116 Created: 1 /30/2007
[1/30/07] Show street names with bold text consistently on all plan sheets. See redlines,
sheet 6 for clarification.
Number: 117 Created: 1 /30/2007
[1/30/07] Please label all utility easements on the Overall Utility Plan sheets. See redlines.
Number: 118 Created: 1 /30/2007
(1/30/07] Show and label the new proposed ROW for West Willox Lane on the Overall Utility
Plan sheet.
Number: 119 Created: 1 /30/2007
[1/30/07] Show the existing ROW limits for Willox Lane east of the Arcadia property on the
south side. The interim street widening and taper back into existing shall be contained
within City ROW. Additional ROW may be needed off -site to make the interim widening
work. If any additional ROW is needed, this will need to be dedicated by separate document
and shall be referenced on the Plat. See comments on sheet 13 for clarification.
Number: 120 Created: 1 /30/2007
(1/30/07] Shortline Road street name is not approved. Please provide an alternative street
name and revise the plans accordingly. There is an existing Shoreline Rd. in Fort Collins.
Number: 121 Created: 1 /30/2007
[1/30/07] No sight distance easements need to be dedicated for this project. Please remove
SDE labels at 90 degree elbow intersections on the Utility Plans and remove the SDE note
from the Plat cover sheet.
Number: 122 Created: 1 /31 /2007
[1/31/07] For all sag curves with inlets proposed, please show a maximum slope of 0.5
percent on both sides of the inlet per LCUASS 7.4.1.6.2
Page 1