HomeMy WebLinkAboutOLD TOWN NORTH SUNTERRACE TOWNHOMES - MAJOR AMEND./REPLAT - 16-09 - CORRESPONDENCE - CORRESPONDENCE-CONCEPTUAL REVIEWE. ADDRESS NUMERALS Address numerals shall be visible from the street fronting the property, and posted with a minimum six-inch high numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable). PLEASE NOTE: While not a requirement, it would be extremely helpful to emergency services and the general public if the addresses were mounted on both the front and rear of the structures. (2006 International Fire Code 505.1) For further information, please contact Carle Dann, 219-5337. Response: We agree with the address numeral requiement and will comply. 9. The change of the type of townhomes will have little effect on the existing electric system. There could be some minor system modifications charges for adding some new service lines. Response: Acknowledged. 10. Light and Power has existing primary and vaults along the south side of Osiander St. If the road is widened on the north side, there will be a systems modification cost for a primary vault at 302 Osiander St. and the system west of Blondel St. If the south side of the road is widened seven primary vaults, all of the primary and secondary cable and several secondary vaults and streetlights will need to be replaced and relocated at the owner's expense. For further information, please contact Alan Rutz, 221-6700. The Osiander Street Section will be widened on the north side with this replat from approximately Units M-18 to M-25 east to Redwood Street (Baum Street to Redwood Street). There will be no widening of Osiander on the south side. See Osiander Street Plan and Profile Sheet for the limits of the wider section and the Master Improvements Plan for the limits of the reconstruction of a portion of existing Osiander Street. 11 feet to the building, on 800-foot centers thereafter; residential outside Urban Growth Area, 500 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter. These requirements may be modified if buildings are equipped with automatic fire sprinkler systems. (2006 International Fire Code 508.1 and Appendix B.) Existing fire hydrants service the proposed lots and are well within the 400 feet requirement. See Master Utility Plan and its legend for existing fire hydrant locations. B. RESIDENTIAL AUTOMATIC FIRE SPRINKLERS An automatic sprinkler system installed in occupancies in accordance with Section 903.3 shall be provided throughout all buildings with a Group R (Residential) fire area. (Exceptions: Detached one- and two-family dwellings and multiple single-family dwellings (townhomes) not more than three stones above grade plane in height with a separate means of egress.) (2006 International Fire Code 903.2.7 and 2006 International Building Code 101.2.) Response: Proposed townhouse design does not exceed two stories in height and maintains a seperate means of egress for each unit. Therefore fire sprinklers are not required per these codes. C. BUILDING AREA The proposed building exceeds 5,000 square feet for Type V construction and shall be fire contained or fire sprinklered. PLEASE NOTE: This comment likely will not apply based on the information provided by the applicant, but I included it for reference. (2006 International Fire Code New Table 903.1 and Section 702). Response: Proposed townhouse units are a maximum of 1,313sf two-story units seperated by a 1hr. rated firewall containing 2 layers of 5/8" type X drywall each side. Therefore fire sprinklers are not required per these codes. D. KEY BOXES REQUIRED Poudre Fire Authority requires a key box ("Knox Box") to be mounted in approved location(s) on every new building equippedwith a required fire - sprinkler system or fire -alarm system. 2006 International Fire Code 506.1; PFA BUREAU POLICY 88-20 Response: Knox Box would not be required in this instance as fire sprinklers or alarms are not included. 10 the billings. Provide a copy of the HOA documents during the PDP process. Acknowledged. Water services will be provided similar to the original Old Town North project. A copy of the HOA documents will be provided during the PDP process. D. Water or sewer services not used must be abandoned at the main. In addition, the method of providing services must be consistent (i.e. all individual services to individual units or all one service to each 4 or 6 unit building). Existing water services not used will be abandoned at the main. Block 7 (single- family attached units M-18 to M-25) is serviced by existing water and sewer services, one service to each 4-unit building. Block 9 Single -Family Attached Units M-25 to M-32 (Originally Platted as Single Family Attached) are serviced by existing water and sewer services, one service to each 4 Unit Building. Block 9 Single -Family Attached Units 13-24 are provided sewer service individually at Alley L. These Lots were originally platted as Single Family detached and 5 existing services are usefuL One Water Service to each 6 Unit Building will be provided. Water services not used at Cajetan Street will be abandoned at the main. Block 9 Single -Family Attached Units 1-12 are provided sewer service individually at Alley L. These Lots were originally platted as Single Family detached and 6 existing services are useful. One Water Service to each 6 Unit Building will be provided. Two existing Services at the northwest Comer of the Site will be abandoned with the Osiander Street Re -Construct. See Master Utility Plan for Existing and Proposed Services and Water Services to be abandoned at the Main. See Master Improvements Plan for limits of Osiander Street Re - Construct. E. Development fees and water rights due at building permit. For further information, please contact Roger Buffington, 221-6700. .Acknowledged. 8. The following comments are from the Poudre Fire Authority: A. WATER SUPPLY Fire hydrants, where required, must be the type approved by the water district having jurisdiction and the Fire Department. Hydrant spacing and water flow must meet minimum requirements based on type of occupancy. Minimum flow and spacing requirements include: Commercial, 1,500 gpm at 20 psi residual pressure, spaced not further than 300 feet to the building, on 600-foot centers thereafter; residential within Urban Growth Area, 1,000 gpm at 20 psi residual pressure, spaced not further than 400 9 Acknowledged: Onsite detention with a 2-year historic release rate at 0.2 cfs/acre for water quantity has been provided. We are not detaining in a Parking area. See Final Drainage, Sediment / Erosion Control, and Stormwater Quality Report and Final Utility Plans submitted with this application. I. Water quality treatment is required as described in the Urban Storm Drainage Criteria Manual, Volume 3 — Best Management Practices (BMPs). The use of any of the BMPs is encouraged. Acknowledged: Water quality treatment is being provided as described in the Urban Storm Drainage Criteria Manual, Volume 3 — Best Management Practices (BMPs). See Final Drainage, Sediment / Erosion Control, and Stormwater Quality Report and Final Utility Plans submitted with this application. M. The design of this site must conform to the drainage basin design of the Dry Creek Master Drainage Plan as well the City's Design Criteria and Construction standards. The design of this site conforms to the drainage basin design of the Dry Creek Master Drainage Plan as well the City's Design Criteria and Construction standards. See Final Drainage, Sediment / Erosion Control, and Stormwater Quality Report and Final Utility Plans submitted with this application. n. The city-wide development fee is $4,420/acre ($0.1015/sq.ft.) for new impervious area over 350 sq.-ft. No fee is charged for existing impervious area. This fee is to be paid at the time each building permit is issued. For further information, please contact Glen Schlueter, 221-6700. Acknowledged. 7. Water and Wastewater comments are as follows: A. Existing mains: As shown in the Old Town North approved utility plans. Acknowledged. B. The section of 8-inch water main near the east end of Osiander must be completed north of the proposed townhome lots. Acknowledged: The section of 8-inch water main near the east end of Osiander will be completed north of the proposed townhome lots with this project. See the Master Utility Plan with the Final Utility Plans submitted with this application. C. A single water service to a building containing multiple single family attached units is allowed providing there is an HOA that is responsible for 8 h. Regarding the Dry Creek Floodplain, it has been remapped and is available online or from the Stormwater Utility. The NECCO (Northeast College Corridor Outfall) project is over 90% designed but construction of the outfall is not funded. The intent of the NECCO studies and design work is to provide guidance; however, the actual construction to facilitate development is not normally funded by the City. If regional improvements are involved, the Utility does take opportunities to cost share with developers if the funds are available. Stormwater projects are prioritized by City Council and are primarily projects that remove citizens from flooding. Acknowledged. Regarding interim drainage at northeast comer of site, Stormwater has not heard of any recent plans by the developer to construct any interim drainage improvements. A detention pond design has been provided at the northeast comer of the Old Town North site on Block 6 that will be considered a permanent drainage improvement due to lack of availability of Dry Creek storm drainage improvements. Discussions with the Stormwater Utility has resulted in the option of providing an absorption field type outfall. Design for this type of outfall has been provided by our firm in the past and we are well acquainted with the design parameters required for a well -functioning system The detention pond absorption outfall is designed based on the following: • A conservative assumed percolation rate of 15 minutes per inch (converted to cubic feet per second) for the existing sand and gravel layer. The percolation rate is most likely between 3 and 5 minutes per inch based on previous experience with percolation tests for similar materials. An allowable release rate of 0.20 cfs per acre for the contributing area for developed conditions for the Sunterrace Townhomes and future Block 6 development (assumed for apartments). j. A drainage and erosion control report and construction plans are required and must be prepared by a Professional Engineer registered in Colorado. Acknowledged. A Final Drainage, Sediment / Erosion Control, and Stormwater Quality Report and Final Utility Plans prepared by a Professional Engineer registered in Colorado have been submitted with this application. k. Onsite detention is required with a 2-year historic release rate for water quantity. Parking lot detention for water quantity is allowed as long as it is not deeper than one foot. In the Dry Creek basin the 2-year historic release rate is 0.2 cfs/acre. 7 B. There are no restrictions on the construction of townhomes in the Poudre 500-year floodplain. Acknowledged. C. Critical facilities may not be constructed in the Poudre 500-year floodplain. Any change of use of structure or property in a 500-year floodplain may not result in a new critical facility. Acknowledged. D. These comments only apply to the Old Town North property east of Jerome Street. Acknowledged. E. The floodplain administrator for this basin is Marsha Hilmes-Robinson (224-6036). Acknowledged. f. In response to the discussion item, the status of East Vine Drive is that the design is 30% complete. For more information please contact the project manager with the Engineering Department, Rick Richter (221-6798). Acknowledged. g. Regarding the Greeley Water line status, dewatering wells are currently being installed, and the schedule is to cross the Lake Canal before April 15`". The City does not approve the construction plans. Please contact the project engineer, Daniel Rice with Boyle/AECOM at (303) 978-3443 for more information. Acknowledged. We have received plans from Greeley's engineer, Boyle Engineering. J. Any other improvements needed to accommodate the site will need to be designed and constructed as part of this project. Acknowledged. K. All documents associated with the replat(s) shall have the same name as the replat. All final approved documents will have the same name as the replat. L. Street cut fees shall apply to any streets needing to be cut. The fee is tripled for any streets less than 5 years old. Acknowledged. M. A Development Construction Permit (DCP) will need to be obtained prior to starting any work on the site. Acknowledged. N. A utility coordination can be scheduled if needed. Utility coordination meetings are typically scheduled after the preliminary submittal of the project, but can be scheduled prior to submittal upon request, provided that a site plan with preliminary utility layout is provided for routing with the meeting notice. If you are interested in having a utility coordination meeting please contact the development review engineer to have a meeting scheduled. For further information, please contact Sheri Langenberger, 221-6505. A Utility coordination meeting will be scheduled after the first round of review of this submittal. 6. Stormwater Comments are as follows: A. Most of this site was removed from the floodplain by the Dry Creek Project. Some areas still remain in the Cache La Poudre River 500-year floodplain, and must meet applicable requirements of Chapter 10 of City Code. Acknowledged. i E. Any public improvements must be designed and built in accordance with the Larimer County Urban Area Street Standards (LCUASS).\ Acknow led-ed. F. This project is responsible for dedicating any right-of-way and easements that are necessary for this project. Known dedications are: Osiander (for the widening). Acknowledged. Osiander Street right-of-way has been widened from 45' to 51' as directed to meet the City of Fort Collins residential local typical section. See Typical Sections Sheet and Osiander Street Plan and Profile Sheet. G. Utility plans will be needed for this project. A development agreement will be done with this project and an amendment to the existing development agreement will need to be done for the area within the new plat. Acknowledged: Utility plans for this project have been submitted with this application. H. Osiander Street will need to be designed and rebuilt with this project (widened out to accommodate the wider section.) Osiander Street adjacent to Block 9 has been re -designed to accommodate the City of Fort Collins residential local typical section. Please note that a majority of this portion of Osiander Street was not installed with initial Old Town North Construction. A portion of existing Osiander Street will be rebuilt to accommodate the wider section at the intersection of Osiander Street and Baum Street. See Osiander Street Plan and Profile Sheet for the limits of this wider section and the Master Improvements Plan for the limits of the Osiander Street reconstruction. Redwood Street will also need to be constructed along the frontage of the property to be developed. Since the overall property line is not too far north of the intersection, the developer should consider improving Redwood to the overall property line and then all obligations regarding Redwood Street would be fulfilled. Redwood Street will be constructed along the frontage of the property to be developed (to the intersection with Osiander Street). Our preference would be to construct Redwood Street to the north boundary of Old Town North. However, due to the new defined limits of the existing Dry Creek Floodway, and potential conflicts with Stormwater Utility policy regarding floodways, Redwood is currently designed to stay out of the Dry Creek floodway. Refer to Redwood Street Plan and Profile sheet for limits of Redwood Street construction. 3. The narrative mentions widening Osiander to 30' to accommodate parking for the dwellings. Since the lots on the south side of Osiander are detached single-family dwellings, any street parking on Osiander does not count towards meeting the minimum number of parking spaces required as per 3.2.2(K)(1)(b). 4. For the easterly westerly portion, a replat will not be required. For the westerly easterly portion, a replat will be required. A replat is provided for the easterly portion This project will consist of Replatting Blocks 6 & 9, Old Town North and a Portion of Tract E Replat of Evergreen Park. The main purpose of the replat is to redefine Block 9 lots (originally single family detached) to accommodate 6- plex attached units. The widening of Osiander Street to the north results in the requirement for replatting Block 6. 5. Comments from Engineering are as follows: A. Larimer County Road Impact Fees and Street Oversizing Fees are due with the building permit application. Please contact Matt Baker at 221- 6108 if you have any questions regarding these fees. Acknowledged. B. Transportation Development Review Fee (TDRF) is due at the time of submittal. For additional information on these fees please see the development review bullet under www.fcgov.com/engineering/. Noted. C. Any damaged curb, gutter or sidewalk existing prior to construction, as well as streets, sidewalks, curbs and gutters, destroyed, damaged or removed due to construction of this project, shall be replaced or restored to City of Fort Collins standards at the Developer's expense prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. Acknowledged. D. Please contact Joe Olson, 224-6062, and Transportation Planning to schedule a scoping meeting and determine if a traffic study is needed for this project. On 03/03/2009 Shear Engineering Corporation sent the original traffic study for Old Town North prepared by LSC Transportation Consultants, Inc. (Leigh, Scott & Cleary, Inc.) to Matt Wempe (Transportation Planning) for his review and comment. We received an e-mail from Mr. Wempe on 03/27/2009 indicating that he did not feel a traffic study or a Pedestrian LOS worksheet was necessary. 3 April 8, 2009 written response to March 2, 2009 comments Planning ITEM: Old Town North — Sunterrace Townhomes MEETING DATE: March 2, 2009 APPLICANT: Ms. Monica Sweere, Sunterrace Townhomes, LLC, 749 Jerome Street, Fort Collins, CO 80524 c/o Mr. Brian Shear, Shear Engineering Corporation, 4836 South College Avenue, Suite 12, Fort Collins, CO 80525. LAND USE DATA: This is a request to amend the approved Final Plan for Old Town North to introduce a 56-unit townhome project. The primary change from previous land use approvals will be the placement of four 6-plex units in the portion of block 9 that is currently platted for single family lots. The other lots noted, (Block 2, Block 7 and a portion of Block 9) are proposed for 4- plex units. These were originally 4-plex lots, however the new proposed 4-plex units would be different than previously approved and the additional parking will be removed. The two areas affected are located in the northern portion of Old Town North. COMMENTS: 1. The property is zoned C-C-N, Community Commercial — North College. Since the number of total dwelling units is increasing by more than one percent, an Administrative (Type One) review will be required. Please note that the proposed housing type will be considered zero -lot line attached single family (each unit will be on its own lot). Please note as such on application and site plan. Housing type added to plans and application. 2. The minimum required number of parking spaces for single-family attached and multi -family is based on number of bedrooms per unit. 1 bdr = 1.5 spaces, 2 bdr = 1.75 spaces, 3 bdr = 2 spaces. Noted. N