HomeMy WebLinkAboutOLD TOWN NORTH SUNTERRACE TOWNHOMES - MAJOR AMEND./REPLAT - 16-09 - CORRESPONDENCE - (5)Shear Attachments:
Redwood Email and Exhibit (Sheri Langenberger).
TIS email (Joe Olson)
Page 7
R. Thank you.
Number: 66 Created: 6/19/2009
[6/19/09] Stormwater is ready for a hearing.
R. Thank you.
Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington
Topic: Water/Wastewater
Number: 60 Created: 6/16/2009
[6/16/09] On Sheet 11, revise plans to include encasing storm sewer joints within 10 feet
each side of water main when storm located above or less than 18-inches below water
main.
R. Sheet 11 now shows the encasing note as requested on all storm drain and
water crossings.
Number: 61 Created: 6/16/2009
[6/16/09] Has easement been provided for the sanitary sewer and manhole north of
Osiander Street?
R. A 20' x 20' easement is being dedicated with the plat.
Be sure and return all of your redlined plans when you re -submit.
Sincerely:
Ted Shepard
Chief Planner
Pane 6
street patch for the entire section and still satisfy the requirements in 25.5.2. We can talk
about this more in FC so don't worry about adjusting your design before going to public
hearing... we just like to give you an early heads up on this so you can plan your project's
true costs in as soon as possible.
R. Acknowledged. Thank you.
R. At Cajetan Street we now represent a mill and overlay from the outer edge of
first cut to the outer edge of the last cut on the Master Improvements Plan. Please
reference Master Improvements Plan Construction Note No. 13.
Number: 33 Created: 4/29/2009
[6/12/091 [4/29/09] = Scanning issues exist, please see Appendix E6 for all scanning
requirements and Jeff County in Tech Services if you have any questions.
R. Acknowledged.
R. Shear Engineering Corporation has been in contact Technical Services and all
Tech Services Plan scanning issues have been addressed.
Department: Light & Power Issue Contact: Doug Martine
Topic: Landscape Plan
Number: 6 Created: 4/13/2009
[6/5/09] In order to not obstruct the street lighting, street trees must be a minimum of 40 ft.
from streetlight standards (15 ft. if the tree is an ornamental).
RESPONSE: TREES HAVE BEEN ADJUSTED/REMOVED(1 TREE TOTAL) TO MEET
THE MINIMUM SPACING.
[4/13/09] A landscape plan showing planned electric facilities was sent to BHA Design on 4-
13-09. Street tree locations will need to be adjusted to provide 40 ft. minimum clearance
between lights and trees (15 ft. if the tree is an ornamental). Also, all trees must be a
minimum of 5 ft. from electric vaults.
Department: Traffic Operations Issue Contact: Ward Stanford
Topic: Plat
Number: 59 Created: 6/15/2009
[6/15/09] Since no Transportation Impact Study was received, please contact Ward
Stanford 221-6820, to discuss the extent of the change in unit type to townhomes and the
increase in the number of dwelling units versus what is already approved.
R. A TIS is not required per Joe Olson. Please see attached email.
Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque
Topic: Floodplain
Number: 67 Created: 6/19/2009
[6/19/09] Please label the floodplain on all sheets that the Floodplain is shown.
R. Acknowledged.
Topic: Stormwater
Number: 65 Created: 6/19/2009
16/19/09] The proposed 3:1 side slopes for the detention pond will be granted as a variance.
This is due to the pond being temporary. Extra language will be added in the Development
Agreement to ensure that the pond is built exactly as designed. Any slopes steeper than 3
to 1 will not be allowed and will have to be rebuilt in the field.
Page 5
Topic: Landscape Plan
Number: 47 Created: 5/3/2009
[6/12/09] 1 read your response to this comment and need to refer you to your City Planner
and the Light and Power Department from here.
RESPONSE: ACKNOWLEDGED
[5/3/09] Two trees are shown over the Lake Canal box culvert and storm line (NE corner of
Redwood and Cajetan). Are these two things low enough to accommodate the trees?
Number: 48 Created: 5/3/2009
[6/12/091 [5/3/09] M It might help the scannability/legibility of the plan sheet if you
removed all contours and perhaps only showed the contours around the drainage pond and
the Lake Canal drainage areas. We can talk about this more in Final Compliance.
Topic: Plat
Number: 51 Created: 6/12/2009
[6/12/09] The previous r.o.w. to be vacated needs to be shown as "Vacated by Council,
reception #....". Please see Technical Services for exact wording and requirements.
R. The callout has been added to the plat. As soon as a reception # is known, it
will be added to the plat.
Number: 56 Created: 6/12/2009
[6/12/09] Please provide a tract table or statement that states who owns and maintains
Tract HHH.
R. A note has been added to the plat indicating that Tract HHH will be owned and
maintained by the Homeowner's Association.
Number: 57 Created: 6/12/2009
16/12/09] The plat legend needs to indicate whether the easements (A-F) are existing (and if
so, how were they dedicated) or proposed with this plat.
R. The plat legend now differentiates between proposed and existing easements.
Number: 58 Created: 6/12/2009
[6/12/09] Would prefer to see all easements dimensioned and labeled on the plat itself and
not off to the side in a legend with all future plats. It makes it more difficult to determine
what is being dedicated. It's not that it's impossible to do, it's just more time consuming and
it's much easier to miss an error. Thank you.
R. Acknowledged.
Number: 69 Created: 6/22/2009
[6/22/09] Please show the neighboring property boundaries and label adjoining properties.
R. Acknowledged.
Topic: Utility Plan
Number: 14 Created: 4/28/2009
[6/12/09] [4/28/09] Sheet 5 - M Please see LCUASS 25.5.2 for street repair
requirements and adjust the approximate limits of street cut accordingly. There are a couple
of options with the best one to keep the project costs down being this: Continue to show the
full depth street patches in the locations shown and do a mill and overlay from the outer
edge of first cut to the outer edge of the last cut. This way you won't have to do a full depth
Page 4
[4/29/09] 3:1 slopes off the north sidewalk on Osiander requires a variance from
stormwater. Typically engineering requires 4:1 unless a flat to nearly flat area of 1-2' is
provided at the bow for pedestrian safety.
R. After researching the right-of-way and property ownership east of Redwood
Street, it has been determined that an offsite easement is not necessary due to
the old alignment of Redwood and associated right-of-way was never vacated.
Please see the email correspondence with Sheri Langenberger, Engineering,
attached to this letter.
R. A nearly flat area of 9' plus (exceeding the 1-2' requirement) is provided at the
bow for pedestrian safety. A variance request has been added to the drainage
report for the 3:1 slopes in the detention pond.
Number: 52 Created: 6/12/2009
[6/12/09] The site plan indicates a private access easement between lots 6 and 7; however,
the plat is calling it out as a public drainage easement. Which is correct? All plan sets need
to match.
R. The easement between Lots 6 and 7 is now labeled as an. "B' PUBLIC
DRAINAGE, UTILITY, & PRIVATE ACCESS EASEMENT' on the Site Plan,
Plat, and Utility Plans.
RESPONSE: LABELED AS SUCH ON THE SITE PLAN
Number: 53 Created: 6/12/2009
[6/12/091 The utility plans are showing a drainage pan on lot 1. Should this be called out as
a drainage easement in addition to the utility and access easement? Otherwise the lot
owner can remove this pan whenever he chooses to.
R. The easement is now called out as a drainage easement in addition to an
access easement. The pan is now entirely within the easement.
Number: 55 Created: 6/12/2009
[6/12/09] = Please remove all SDT lines and references where they fall within row. SDT
easements lines and dimensions only need to be shown where they fall on private property
and must be dedicated as such on the plat.
Number: 62 Created: 6/17/2009
[6/17/09] From Technical Services:
1. Plat - Boundary and legal do not close.
2. Plat - Numerous differences between legal and plat. See Redlines.
3. Landscape Plan - Minor line over text (scanning) issues on landscape plan.
R. Technical Services comments have been addressed.
RESPONSE: REDLINE COMMENT ADDRESSED. SCANNING ISSUES TO BE FURTHER
CLEANED UP AT (FC)
Number: 68 Created: 6/22/2009
[6/22/09] Please dedicate the alley row as shown in drawing 803 from LCUASS.
R. The plat now includes the sight distance triangles as shown in drawing 803.
Page 3
Department: Engineering Issue Contact: Susan Joy
Topic: General
Number: 10 Created: 4/28/2009
[6/12/091 [4/28/09] = Groundwater was found within 5 feet of the existing surface which
then requires a Subsurface Water Investigation Report. Please see 5.6.1 of LCUASS and
submit the report with the next round of review. This will need to be addressed prior to
public hearing only if basements are proposed, otherwise, this requirement can wait until
Final Compliance M.
R. Basements are not proposed with this Development. A Subsurface Water
Investigation Report will be provided at Final Compliance.
Number: 13 Created: 4/28/2009
[6/12/09] The Site and Landscape Plan titles do not match the plat. The Utility Plan set is
now correct.
[4/28/09] The plan set titles need to match the plat.
RESPONSE SITE AND LANDSCAPE PLAN TITLES CHANGED TO MATCH UTILITY
PLANS
Number: 28 Created: 4/29/2009
[6/12/09] Please remove all labeling stating that the sidewalk is "future" or "to be
constructed by others". This development is responsible for designing the sidewalk along
Block 6 and constructing the sidewalk along the detention pond as discussed in the earlier
comment. If moving the pond elsewhere on Block 6, the sidewalk is required where ever the
pond is placed.
14/29/09] The sidewalk along the north and east side of Osiander needs to be designed and
constructed along the detention pond frontage with this development or at minimum, from
the ramp at the intersection of Baum and Osiander to Redwood Street. The final limits will
be determined with the final site layout. Also, we'll need to look at the grading on the east
side of Redwood on the north end ... you'll want to either grade to accommodate the future
street and sidewalk or escrow cash in lieu of to regrade the area at such time the street and
sidewalk goes through. This will be addressed in the Development Agreement with
requirements that an estimate for our review and approval and the escrow due prior to the
first building permit.
R. All labels indicating that the sidewalk in Osiander would be "future" have been
removed. The sidewalk is shown as being constructed with the project.
R. The Sidewalk will be designed and constructed from the ramp at the
intersection of Baum and Osiander to Redwood Street. Our Preference would
be to accommodate the future Redwood street and sidewalk to the property line
now but due to the current FEMA Dry Creek 100 Year floodplain location we
cannot. However, Redwood Street has been installed as far as geometrically
possible to avoid disturbing the floodplain and matches the future Redwood
street grade.
RESPONSE'FUTURE' SIDEWALK LABEL REMOVED FROM SITE PLAN.
Number: 30 Created: 4/29/2009
[6/12/09] In addition to the comment below, 3:1 slopes are now shown off the back of
Redwood. A slope easement and temporary construction easement is required wherever
grading is shown offsite or outside of row. A letter of intent from the affected property owner
is required prior to hearing.
Page 2
STAFF PROJECT REVIEW
Cihof Fort Cullins
David Kasprzak Date: 6/23/2009
BHA Design
1603 Oakridge Drive
Fort Collins, CO 80525
Staff has reviewed your submittal for SUNTERRACE TOWNHOMES, OLD TOWN NORTH
MAJOR AMENDMENT/REPLAT - TYPE I, and we offer the following comments:
ISSUES:
Department: Current Planning
Topic: Grading Plan
Issue Contact: Dana Leavitt
Number: 21 Created: 4/29/2009
[6/16/09] The LOD line can be added to all sheets at the Final plan review. See Utility
Plans for redlined sheets for the LOD line.
[4/29/091 A Limit -of -Development (LOD) line shall be shown on the plans per Section
3.4.1.(N). The LOD will be determined by the Environmental Planner, Current Planning
Office.
R. The LOD is now shown as requested.
RESPONSE: (LOD) ADDED TO SITE AND LANDSCAPE PLANS
Topic: Landscape Plan
Number: 63
Created: 6/17/2009
[6/17/09] The detention pond will need to have landscape plantings in it to reduce the visula
impact to the adjacent area.
RESPONSE: SHRUBS HAVE BEEN ADDED TO THE PLAN PER DISCUSSION AT LAST
STAFF REVIEW MEETING IN REGARDS TO THE ULTIMATE INTENTION OF THE
POND. WHICH IS TEMPORARY IN THE LONG-TERM.
Topic: Overlot Grading Plan
Number: 34 Created: 4/29/2009
[6/16/09] To be addressed at Final Plan review. The LOD line per Section 3.4.1(N) is
different than the project development/limits of construction line. Show LOD line per redline
plans.
[4/29/09] Add the LOD line to the plan.
R. The LOD is now shown as requested.
Topic: Utility Plans
Number: 64 Created: 6/17/2009
[6/17/09] Remove Environmental Planner signature block from Utility Plan set per redline
sheets.
R. The Environmental Planner signature block has been removed from the redlined
sheets.
Page I Acypl'-J'nE 7�