HomeMy WebLinkAboutOLD TOWN NORTH SUNTERRACE TOWNHOMES - FDP - 16-09/A - CORRESPONDENCE -Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque
Topic: Plat
Number: 79 Created: 9/28/2009
[9/28/09] Some spot elevations are hard to read on the grading plan due to line over text
drafting issues.
Number: 80 Created: 9/28/2009
[9/28/09] Please include an erosion escrow calculation in the drainage report with the mylar
submittal.
Number: 81 Created: 9/28/2009
[9/28/09] Please submit 3 signed drainage reports with the mylar submittal.
Be sure and return all of your redlined plans when you re -submit.
If you have any questions regarding these issues or any other issues related to this project,
please feel free to call me at (970) 221-6750.
Sincerely:
TIC
Ted Shepard
Chief Planner
Page 4
they are entirely missing from the sheets. See Appendix E4 and LCUASS for other general
requirements.
Number: 87 Created: 9/30/2009
[9/30/09] Please complete and submit appendix E4 with the next submittal and make sure
that everything required by LCUASS or the checklist is correctly shown on the plans to avoid
additional comments and rounds of review.
Number: 92 Created: 10/6/2009
[10/6/09] Please adjust your line weights so that proposed = dark and existing = light.
Number: 93 Created: 10/6/2009
[1016/09] Sheet 6 - remove all pavement design notes. The pavement design is submitted
separately and must be approved prior to constructing the street.
Number: 94 Created: 10/6/2009
[10/6/09] Sheet 14 - will need some sort of erosion control at the end of Redwood's curb
and gutter. Please look at the grading to the bike path and make sure that the drainage isn't
directed over it.
Number: 95 Created: 10/6/2009
[10/6/09] Sheet 16 - Please label all private details as "private" or "on site". Please remove
detail 709 and provide Stormwater's detail D10, 11, 12, or 13, whichever applies. Please
add details 1601 and 1604. Remove detail "Ramp R-3" and the vertical 6" curb and gutter
detail if not private.
Number: 96 Created: 10/6/2009
[10/6/09] Detail Sheets - Please add CDOT M-412-1 details for the rebar in the street (there
are 5).
Number: 97 Created: 10/6/2009
[10/6/09] A variance to the minimum cover requirements was granted provided that the
street was constructed in concrete per the drawing sent by email on 10/5. Please add this
variance request to line 48 of the General Notes.
Department: Technical Services Issue Contact: Jeff County
Topic: Plat
Number: 75 Created: 9/22/2009
[9/22/09] The direction of the last curve in the legal description has not been added. This
comment has not been addressed from the last round of review.
Number: 76 Created: 9/22/2009
[9/22/09] The boundary & legal close.
Number: 77 Created: 9/22/2009
[9/22/09] Redwood ROW vacation must be recorded & noted on the plat prior to filing, or
the City must sign the plat as an owner.
Number: 78 Created: 9/22/2009
[9/22/09] Who owns & maintains the tracts?
Page 3
14
Number: 69 Created: 6/22/2009
[9/30/09] [7/21/09] [6/22/09] Please show the neighboring property boundaries and label
adjoining properties.
Topic: Site Plan
Number: 88 Created: 10/6/2009
[10/6/09] Please adjust your line weights so that proposed = dark and existing = light.
Number: 89 Created: 10/6/2009
[10/6/09] Please see Appendix E6 for all scanning requirements and bring the plan set up to
standard.
Topic: Utility Plan
Number: 14 Created: 4/28/2009
[9/30/09] Please identify all street cuts (see the earlier comment below) and add the street
cut note:
Limits of street cut are approximate. Final limits are to be determined in the field by the City
Engineering Inspector. All repairs to be in accordance with City street repair standards.
[7/21/09] Just keeping this comment alive through Final [6/12/09] [4/28/09] Sheet 5 - (FC)
Please see LCUASS 25.5.2 for street repair requirements and adjust the approximate limits
of street cut accordingly. There are a couple of options with the best one to keep the project
costs down being this: Continue to show the full depth street patches in the locations shown
and do a mill and overlay from the outer edge of first cut to the outer edge of the last cut.
This way you won't have to do a full depth street patch for the entire section and still satisfy
the requirements in 25.5.2. We can talk about this more in FC so don't worry about
adjusting your design before going to public hearing ... we just like to give you an early heads
up on this so you can plan your project's true costs in as soon as possible.
Number: 83 Created: 9/30/2009
19/30/091 Scannability and legibility continue to be a problem with the plan set. Please see
Appendix E6 or see Tech Services directly.
Number: 84 Created: 9/30/2009
[9/30/09] The Lake Canal Company is shown as signing the plat. They will need to sign the
utility plan set as well as the landscape plan if proposing grading or landscaping within their
easement or buffer.
Number: 85 Created: 9/30/2009
[9/30/09] This project is responsible for the design and construction of the street frontage
along the property boundary. All areas left unbuilt along your frontage for the future will
need to be escrowed with cash plus a 25% contingency in lieu of construction. An estimate
for our review and approval of the unconstructed areas must be submitted and the dollar
amount (plus the 25% in contingency) must be provided in cash prior to the first building
permit. We will put this in the development agreement at the time of writing.
Number: 86 Created: 9/30/2009
[9/30/09] The utility plan is very difficult to read due to scanning and legibility issues.
Existing and proposed construction is shown in the same light lineweights and its difficult to
determine what is actually proposed versus existing improvements (please show existing
using greyscale and proposed as dark lineweights). Incomplete legends are provided or
Page 2
STAFF PROJECT REVIEW
Cityof Fort Collins ,
David Kasprzak Date: 10/6/2009
BHA Design
1603 Oakridge Drive
Fort Collins, CO 80525
Staff has reviewed your submittal for OLD TOWN NORTH SUNTERRACE TOWNHOMES,
MAJOR AMEN DMENT/REPLAT - TYPE I AND FINAL PLANS, and we offer the following
comments:
ISSUES:
Department: Current Planning Issue Contact: Dana Leavitt
Topic: General
Number: 74 Created: 9/22/2009
[9/22/09] All comments have been resolved.
Department: Engineering Issue Contact: Susan Joy
Topic: General
Number: 10 Created: 4/28/2009
[9/30/09] Please provide a copy of the Subsurface Water Investigation Report.
[7/21/09] [6/12/09] [4/28/09] (FC) Groundwater was found within 5 feet of the existing
surface which then requires a Subsurface Water Investigation Report. Please see 5.6.1 of
LCUASS and submit the report with the next round of review. This will need to be
addressed prior to public hearing only if basements are proposed, otherwise, this
requirement can wait until Final Compliance (FC).
Topic: Landscape Plan
Number: 48 Created: 5/3/2009
[9/30/09] Scannability and legibility continue to be a problem with the plan set. Please see
Appendix E6 or see Tech Services directly.
[7/21/09] (6/12/09] [5/3/09] (FC) It might help the scannability/legibility of the plan sheet if
you removed all contours and perhaps only showed the contours around the drainage pond
and the Lake Canal drainage areas. We can talk about this more in Final Compliance :)
Number: 90 Created: 10/6/2009
[10/6/09] Please see Appendix E6 for all scanning requirements and bring the plan set up to
standard.
Number: 91 Created: 10/6/2009
[10/6/09] Please adjust your line weights so that proposed = dark and existing = light.
Topic: Plat
Number: 51 Created: 6/12/2009
[9/30/09] Just carrying this comment forward. It may need to be labeled as "Ordinance xx"
instead of variance.
[7/21/09] [6/12/09] The previous row to be vacated needs to be shown as "Vacated by
Council, reception #....". Please see Technical Services for exact wording and
requirements.
Page 1