HomeMy WebLinkAboutBDR FOUR-PLEX, 621 S. MELDRUM ST. - PDP120030 - CORRESPONDENCE - (5)Comment Number: 2 Comment Originated: 11/26/2012 11/26/2012: The applicant's conceptual review response letter indicates that the 14' front building setback matches the existing contextual setback. Documentation will be needed verifying the front setback of one or both of the buildings on abutting lots. Response: Revised Comment Number: 3 Comment Originated: 11/26/2012 11/26/2012: The parking stall depth for residential parking needs to be a minimum of 18'. This distance can be reduced to 16' if the space overhangs a minimum 6' wide landscape area (Sec. 3.2.2(L)(4)). The site plan shows 16' deep stalls, but doesn't dimension the width of the landscape setback. Putting a scale on the drawing, the setback is less than 6, meaning the stalls would need to be 18' in depth. Response: Revised. We now have 6' landscape setback (16' stall with 2' overhang) Comment Number: 4 Comment Originated: 11/26/2012 11/26/2012: Label the surface material of the parking lot (asphalt or concrete). Response: Labeled as asphalt Comment Number: 7 Comment Originated: 11/26/2012 11/26/2012: New 6' privacy fence is labeled along north lot line. A similar fence is required along the south lot line for the parking area. A fence appears to be shown on the plan. Please label the height of the fence and whether it's new or existing. Response: Fence is now a 5' privacy fence with detail shown on sheet LS1 Department: Traffic Oper, n Contact: Ward Stanford, 970-221-6820, wstanford@fcgov.com Topic: General Comment Number: 2 Comment Originated: 12/05/2012 12/05/2012: No additional comments. Topic: Traffic Impact Study Comment Number: 1 Comment Originated: 12/05/2012 12/05/2012: For the record, the TIS was waived. Department: Water -Wastewater Engineering Contact: Roger Buffington, 970-221-6854, rbuffington@fcgov.com Topic: Construction Drawings Comment Number: 1 Comment Originated: 12/04/2012 12/04/2012: Add the curb stop and meter pit at the front of the lot preferably between the curb and sidewalk. Get locates on gas and electric in that area and show on plans. Response: Curb stop and meter pit added. Existing gas and electric labeled. Comment Number: 2 Comment Originated: 12/04/2012 12/04/2012: Revise note on tapping saddle as shown on the redlined plans. Response: Comment acknowledged. Comment Number: 3 Comment Originated: 12/04/2012 12/04/2012: Show a minimum of 3 feet between the domestic service and the fire line. Response: Comment acknowledged. 3' shown between fire and domestic lines. Department: Zoning Contact: Peter Barnes, 970-416-2355, gbarnes@fcgov.com Topic: Building Elevations Comment Number: 5 Comment Originated: 11/26/2012 11/26/2012: The wall height of the stair enclosure on the south side appears to be 215. This requires aside setback of 7' per 4.9(D)(6)(d). The setback distance isn't shown on the site plan, but it scales to less than 7'. Response: Line of the required setback per 4.9(d)(6)(d) has been shown on the east and west elevations for reference. Comment Number: 6 Comment Originated: 11/26/2012 11/26/2012: label the finished grade line on the elevations. Response: Finish grade has been noted on the elevations. Topic: Site Plan Comment Number: 1 Comment Originated: 11/26/2012 11/26/2012: General note #13 on the site plan needs to be removed. It doesn't apply to this project. Response: Deleted Graphically it do of look like it. If It is not, show bearing & c ice to accepted corner. Response: Comment acknowledged.A new corner was set. The old corner was removed as well as the note referencing it. Department: Technical Services Contact: Jeff County, 970-221-6588, icountV@fcgov.com Topic: Plat Comment Number: 9 Comment Originated: 12/04/2012 12/04/2012: If the Athur Ditch easement is existing, please note. If it is being dedicated by this plat, a signature block & a signature by an appropriate Ditch Company representative is required. The signature block must acknowledge & accept the easement dedication. Response: Signature block added. Comment Number: 10 Comment Originated: 12/04/2012 12/04/2012: Are there any lienholders? If so, please add a Lienholders signature block. Response: No lienholders. Comment Number: 11 Comment Originated: 12/04/2012 12/04/2012: Please change "measured" to "assumed" in the Basis Of Bearings statement (Note #1). Response: Comment acknowledged. Comment Number: 12 Comment Originated: 12/04/2012: Are there any easements being vacated by this plat? Response: No easements are being vacated. Comment Number: 13 Comment Originated: 12/04/2012: Please correct the labels to the east of the property in Block 96. Response: Comment acknowledged. Comment Number: 14 Comment Originated: 12/04/2012: Please add "Basis Of Bearings" to the north line of the property. Response: Comment acknowledged. Comment Number: 15 Comment Originated: 12/04/2012: Why is this property being replatted? Response: As a single instrument for multiple easement dedications. Topic: Site Plan 12/04/2012 12/04/2012 12/04/2012 12/04/2012 Comment Number: 16 Comment Originated: 12/04/2012 12/04/2012: The project name does not match the Subdivision Plat. We are suggesting that the Subdivision Plat name change, so this may need to change. Response: Revised Comment Number: 17 Comment Originated: 12/04/2012 12/04/2012: There are line over text issues. Response: Reviewed and revised Comment Number: 18 Comment Originated: 12/04/2012 12/04/2012: The Owner's Certification of Approval shows Elizabeth And City Park Corner LLC as the owner. Is this correct? Response: Revised to BDR, LLC Subdivision Plat ie change, so this may need to change. Response: Comment acknowledged. Comment Number: 20 12/05/2012: There are line over text issues. Response: Comment acknowledged. Comment Number: 21 12/05/2012: There is a text over text issues. Response: Comment acknowledged. Topic: Lighting Plan Comment Originated: 12/05/2012 Comment Originated: 12/05/2012 Comment Number: 23 Comment Originated: 12/05/2012 12/05/2012: We are suggesting that the Subdivision Plat name change, so this may need to change. Response: Comment acknowledged. Topic: Plat Comment Number: 1 Comment Originated: 12/04/2012 12/04/2012: We would like the name to change, as a BDR is a city review process. Response: Comment acknowledged. Comment Number: 2 Comment Originated: 12/04/2012 12/04/2012: The boundary and legal description close. Response: Comment acknowledged. Comment Number: 3 Comment Originated: 12/04/2012 12/04/2012: The name in the Statement Of Ownership And Subdivision does not match the name in the title. Response: Comment acknowledged. Comment Number: 4 Comment Originated: 12/04/2012 12/04/2012: All easements must be locatable. Response: Comment acknowledged. Comment Number: 5 Comment Originated: 12/04/2012 12/04/2012: Please provide both record and measured bearings & distances. Response: Comment acknowledged. Comment Number: 6 Comment Originated: 12/04/2012 12/04/2012: Please make the set & found monument symbols the same size in the legend and on the boundary. Response: Comment acknowledged. Comment Number: 7 Comment Originated: 12/04/2012 12/04/2012: Please add a distance to the found property corner on the west side of the alley. See redlines. Response: Comment acknowledged. Comment Number: 8 Comment Originated: 12/04/2012 12/04/2012: Is the found pin at the southeast comer of the boundary at the accepted comer? Comment Number: mment Originated: 12/04/2012 12/04/2012: Is the piping that drains the roof sized for the 100-yr storm. Response: Most of the roof drain connections were replaced with at -grade downspouts and metal sidewalk chases that discharge into a swale. The remaining pipes are adequate for the 100-year storm. Comment Number: 2 Comment Originated: 12/04/2012 12/04/2012: The retaining walls look toy be in conflict with existing trees that are located on adjacent properties and may compromise the health of these. Response: Comment acknowledged. Comment Number: 3 Comment Originated: 12/04/2012 12/04/2012: A pld with an underdrain may be the best treatment for the water quality pond. Response: Comment acknowledged. With this submittal, a traditional EDB was sized with a 12-hour drain time (min. 0.50" dia. orifice openings). Department: Technical Services Contact: Jeff County, 970-221-6588, LountyC�fcgov.com Topic: Building Elevations Comment Number: 22 Comment Originated: 12/05/2012 12/05/2012: We are suggesting that the Subdivision Plat name change, so this may need to change. Response: Comment acknowledged. Topic: Construction Drawings Comment Number: 24 Comment Originated: 12/05/2012 12/05/2012: We are suggesting that the Subdivision Plat name change, so this may need to change. Response: Comment acknowledged. Comment Number: 25 Comment Originated: 12/05/2012 12/05/2012: The sub -title should match the Subdivision Plat. Response: Comment acknowledged. Comment Number: 26 Comment Originated: 12/05/2012 12/05/2012: The descriptions of benchmark CSU2 on sheets C0.00 & C0.01 do not match the published Clty of Fort Collins Vertical Control Network description. Response: Comment acknowledged. Department: Technical Services Contact: Jeff County, 970-221-6588, icounty@fcgov.com Topic: Construction Drawings Comment Number: 27 Comment Originated: 12/05/2012 12/05/2012: There are line over text issues on sheets C1.00, C2.00 & C3.00. Response: Comment acknowledged. Topic: Landscape Plans Comment Number: 19 Comment Originated: 12/04/2012 12/04/2012: The project name does not match the Subdivision Plat. We are suggesting that the Response: Comment acknowledged. The easement width was revised to 8'. Comment Number: 5 Comment Originated: 12/04/2012 12/04/2012: Please add our standard note to the plat -"There shall be no private conditions, covenants or restrictions that prohibit or limit the installation of resource conserving equipment or landscaping that are allowed by Sections 12-120—12-122 of the City Code." Response: Comment acknowledged. Note added. Department: Environmental Planning Contact: Lindsay Ex, 970-224-6143, lex@fcgov.com Topic: General Comment Number: 1 11/30/2012: No comments. Department: PFA Contact: Jim Lynxwiler, 970-416-2869, Topic: General Comment Number: 01 Comment Originated: 11/30/2012 j lynxwiler � poudre-fire.org Comment Originated: 12/04/2012 12/04/2012: PREMISE IDENTIFICATION Address numbers shall be visible from the street fronting the property, plainly visible, and posted with a minimum of six-inch numerals on a contrasting background. 2006 International Fire Code 505.1 Response: Comment noted. Department: PFA Contact: Jim Lynxwiler, 970-416-2869, Ilynxwiler@poudre-fire.org Topic: General Comment Number: 02 Comment Originated: 12/04/2012 12/04/2012: BALCONIES AND DECKS Sprinkler protection shall be provided for exterior balconies, decks, and ground floor patios of dwelling units where the building is of Type V construction. 2006 International Fire Code 903.3.1.2.1 Response: Comment noted. Comment Number: 03 Comment Originated: 12/04/2012 12/04/2012: KEY BOXES REQUIRED Poudre Fire Authority requires at least one key box ("Knox Box") to be mounted in approved location(s) on every new building equipped with a required fire sprinkler or fire alarm system. The top shall not be higher than 6 feet above finished floor. 2006 International Fire Code 506.1 and Poudre Fire Authority Bureau Policy 88-20 Response: Comment noted. Department: Stormwater Engineering Contact: Wes Lamarque, 970-416-2418, wlamargue@fcgov.com Topic: General Comment Number: 10 Comment Originated: 12/04/2012 12/04/2012: There are concerns about the proposed roof drain on the south side of the property that extends into the right-of-way and daylights into the curb and gutter. Please provide more information about the proposed depth of this roof drain in the right-of-way or redesign to terminate the drain at the back of sidewalk and run the water through a sidewalk chase and channel to the curb and gutter Response: Roof drains terminated prior to sidewalk with metal sidewalk chases added. Comment Number: 11 Comment Originated: 12/04/2012 12/04/2012: You are showing approximate asphalt patching limits on sheet C1, please add our street cut note to all sheets that show approximate patching limits. Response: Comment acknowledged. Comment Number: 12 Comment Originated: 12/04/2012 12/04/2012: Please update General Note #5 Response: Comment acknowledged. Comment Number: 13 Comment Originated: 12/04/2012 12/04/2012: Please revise General Note #34 to reference the City of Fort Collins Response: Comment acknowledged. Department: Engineering Development Review Contact: Tyler Siegmund, 970-221-6501, tsiegmund@fcgov.com Topic: General Comment Number: 14 Comment Originated: 12/04/2012 12/04/2012: Construction details were not included with this submittal Response: Will be provided at Final design Comment Number: 15 Comment Originated: 12/04/2012 12/04/2012: Proposed utility plan and profiles were not included with this submittal. Response: Will be provided at Final design Topic: Plat Comment Number: 1 Comment Originated: 12/04/2012 12/04/2012: Please add our Site Distance Easement Restrictions language to the plat- contact me for an updated copy of this language. Response: Comment acknowledged. Comment Number: 2 Comment Originated: 12/04/2012 12/04/2012: Easements dedicated on the plat need to be locatable. The site distance easement dimensions are not clear. Response: Comment acknowledged. The easements are locatable. Comment Number: 3 Comment Originated: 12/04/2012 12/04/2012: Arthur Ditch representatives will need to sign the plat. Response: Comment acknowledged. A signature block for Mark Taylor was added. Comment Number: 4 Comment Originated: 12/04/2012 12/04/2012: The current standard for utility easements along alleys are 8 feet wide. See LUCASS figure 7-11 F. Response: The .Iding elevations have been revised to men a intent of 3.5.1 (A) and (B). Topic: Landscape Plans Comment Number: 1 Comment Originated: 12/04/2012 12/04/2012: Other choices might be more appropriate than potentilla for planting in the small bioswale along the south property line. Response: Plantings have been revised Department: Current Planning Contact: Jason Holland, 970-224-6126, Lholland@fcgov.com Topic: Landscape Plans Comment Number: 2 Comment Originated: 12/07/2012 12/05/2012: It is difficult to tell which areas are to be mulch vs. cobble. We want to make sure that areas surrounding drain inlets and drainage areas are cobble. The bio-swale should be cobble as well. Perhaps areas to be cobble can be clarified with a general note. Also a smaller sized cobble would be more appropriate. Response: Hatches have been revised. 1.5"-3" Angular rock is now incorporated in the detention area. Large cobble is preferred for aesthetic around the foundations and fences Department: Engineering Development Review Contact: Tyler Siegmund, 970-221-6501, tiegmund@fcgov.com Topic: General Comment Number: 6 Comment Originated: 12/04/2012 12/04/2012: 3. The cross -sections provided on sheet C3 are both labeled A -A but the plan references cross-section B-B. Also, please show the property lines in relation to the proposed retaining walls to clarity that the walls do not encroach on the properties to the north and south. Response: Comment acknowledged. Cross section designation updated and property line added to the section details. Comment Number: 7 Comment Originated: 12/04/2012 12/04/2012: A temporary construction easement/agreement from the adjacent property owners will be required for the concrete retaining wall construction on the north and south property lines. Response: Comment acknowledged. Comment Number: 9 Comment Originated: 12/04/2012 12/0412012: Arthur Ditch representatives will need to review and sign the utility plans Response: Comment acknowledged. A signature block for Mark Taylor (i.e., ditch representative) was added to the plat and cover sheet. Comment Number: 9 Comment Originated: 12/04/2012 12/04/2012-. The existing sidewalk along the frontage of the property does not currently meet our minimum sidewalk width requirements for a residential local street. If 50 percent or more of the existing sidewalk is removed or damaged as part of the construction of this project then a new 4.5 foot wide sidewalk will be required with the developer responsible for the costs associated. Please add a note referencing this to the plans. Response: Note #13 has been added on sheet LS1. Removal noted on sheet C1.00 and proposed shown on sheet C3.00 City of 111�f1 December 07, 2012 Cathy Mathis The Birdsall Group Berthoud, CO 80513 RE: Big Deal Four Plex, PDP120030, Round Number 1 Community Development and Neighborhood services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax kgov.com/developmentreview Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Jason Holland, at 970-224-6126 or jholland@fcgov.com. Comment Summary: Department: Current Planning Contact: Jason Holland, 970-224-6126, Iholland@fcgov.com Topic: General Comment Number: 1 Comment Originated: 12/04/2012 The drive isle appears to be 23 feet wide, 24 feet is the standard dimension. Response: Drive is 24' wide Comment Number: 2 Comment Originated: 12/07/2012 12/05/2012: A small detail, you might as well reverse the hinges on the trash side door, north side. Comment Number: 3 Comment Originated: 12/07/2012 12/05/2012: Need elevation/detail for perimeter fence and walls. The detail on the utility plans shows a fence design that is too utilitarian, we need to see a more residential oriented design. We are concerned about the cumulative impact of the wall / fence height and design on the neighboring properties. We would like to see the heights minimized. Please present options for a wall surface finish / texture that is enhanced. Response: Priviacy fence it 5'. Detail is provided for the fence on sheet LS1 Comment Number: 4 Comment Originated: 12/07/2012 12/05/2012: The building design / elevations do not meet the intent of Section 3.5.1, most notably 3.5.1(A) and (B). Please explore and present different options and modifications to make the design more complementary to the architectural character of the neighborhood.