Loading...
HomeMy WebLinkAboutCARRIAGE HOUSE APARTMENTS - MOD - MOD120001 - CORRESPONDENCE - (6)• • Community Sopment and Neighborhood Services City of 281 North College Avenue F�ort Collins PO Box 580 Fort Collins, CO 80522 970.221.6760 970.224.6134 - fax /cgov.com Pre -Submittal Meetiines for Building Permits Pre -Submittal meetings are offered to assist the designer/builder by assuring, early on in the design, that the new commercial or multi -family projects are on track to complying with all of the adopted City codes and Standards listed below. The proposed project should be in the early to mid -design stage for this meeting to be effective and is typically scheduled after the Current Planning conceptual review meeting. Applicants of new commercial or multi -family proiects are advised to call 416-2341 to schedule a pre -submittal meeting. Applicants should be prepared to present site plans, floor plans, and elevations and be able to discuss code issues of occupancy, square footage and type of construction being proposed. Construction shall comply with the following adopted codes as amended: 2009International Building Code (IBC) 2009International Residential Code (IRC) 2009International Energy Conservation Code (IECC) 2009International Mechanical Code (IMC) 2009International Fuel Gas Code (IFGC) 2009International Plumbing Code (IPC) as amended by the State of Colorado 2008 National Electrical Code (NEC) as amended by the State of Colorado Accessibility: State Law CRS 9-5 & ICC/ANSI Al 17.1-2003. Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF. Frost Depth: 30 inches. Wind Load: 100- MPH 3 Second Gust Exposure B. Seismic Design: Category B. Climate Zone: Zone 5 Energy Code Use 1. Single Family; Duplex; Townhomes: 2009IRC Chapter 11 or 2009 IECC Chapter 4 2. Multi -family and Condominiums 3 stories max: 2009IECC Chapter 4. 3. Commercial and Multi -family 4 stories and taller: 2009IECC Chapter 5. 9 Comment Letter Generated: 6/8/2011 at 2:11 pm • Community eopment and Neighborhood Services City of 281 North College Avenue /+F�ort Collins PO Box 580 Fort Collins. CO 80522 970.221.6750 970.224.6134 - fax fcgov.com 8. This development proposal will be subject to all applicable standards of the Fort Collins Land Use Code (LUC), including Article 3 General Development Standards. The entire LUC is available for your review on the web at hftp://www.colocode.com/ftcollins/landuse/begin.htm. 9. If this proposal is unable to satisfy any of the requirements set forth in the LUC, a Modification of Standard Request will need to be submitted with your formal development proposal. Please see Section 2.8.2 of the LUC for more information on criteria to apply for a Modification of Standard. 10. Please see the Submittal Requirements and Checklist at: hftp://www.fcgov.com/developmentreview/applications.php. 11. The request will be subject to the Development Review Fee Schedule that is available in the Community Development and Neighborhood Services office. The fees are due at the time of submittal of the required documents for the appropriate development review process by City staff and affected outside reviewing agencies. Also, the required Transportation Development Review Fee must be paid at time of submittal. 12. When you are ready to submit your formal plans, please make an appointment with Community Development and Neighborhood Services at (970)221-6750. 8 Comment Letter Generated: 6/8/2011 at 2:11 pm • Community Apment and Neighborhood Services City of'� 281 North College Avenue Fort Collins PO Box 580 �- Fort Collins, CO 80522 970.221.6760 970.224.6134 - fax /cgov.com 1. Project is subject to normal electric development charges. Please contact me for additional detail. 2. There are two oval electric vaults on Springfield Dr one at the east end and one at the west end of the project area. Show these vaults on the Utility Plan. Advance Planning Contact: Courtney Rippy, 970-416-2283, crippV(&fcgov.com 1. Please see West Central Neighborhood Plan located at: http:/wwww.fcgov.com/advanceplanning/pdf/w-ce ntral-neighborhood-doc. pdf Current Planning Contact: Courtney Rippy, 970-416-2283, crippy(Mcgov.com 1. The property is located within the West Central Neighborhood Plan Subarea and within the NCB - Neighborhood Conservation, Buffer Zone District (LUC 4.9(D)) The Land Use Code standard calls for a 60' setback. The contextual front setback for the existing property on 1319 Shields is around 50'. The site plan submitted shows a 15' set back. Additionally, per LUC 4.9(E)(5) a parking lot can not be located any closer to a public street than the W distance by which the principal building is set back from the street. 2. Using South Sheilds Street as the front of the property, the rear Floor Area Ratio is greater than the maximum .33 on the rear fifty percent of the property. 3. Parking lot screening with 6' fence and trees (must block 75% of headlights) is required 3.2.1(E)(4)(b). 4. Additional building height review LUC 3.5.1 (G) will apply. 5. The building on the southeast comer's side setback is showing 10', the minimum is 14' per 4.9(D)(6)(d). 6. The proposed development project is subject to a Type 2 (Planning and Zoning Board) review and public hearing. The applicant for this development request is required to hold a neighborhood information meeting prior to formal submittal of the proposal. Neighborhood meetings offer an informal way to get feedback from your surrounding neighbors and discover any potential hiccups prior to the formal hearing. Please contact me, at 221-6750, to assist you in setting a date, time, and location. I and possibly other City staff, would be present to facilitate the meeting. 7. Please see the Development Review Guide at www.fcgov.com/drg. This online guide features a color coded flowchart with comprehensive, easy to read information on each step in the process. This guide includes links to just about every resource you need during development review. 7 Comment Letter Generated: 6/8/2011 at 2:11 pm • Community ftopment and Neighborhood Services City of 281 North College Avenue F�ort Collins PO Box 580 Fort Collins, CO 80522 970.221.6760 970.224.6134 - fax fcgov.com 4. Please contact the City's Traffic Engineer, Joe Olson (224-6062) to schedule a scoping meeting and determine if a traffic study is needed for this project. In addition, please contact Transportation Planning for their requirements as well. 5. Any public improvements must be designed and built in accordance with the Larimer County Urban Area Street Standards (LCUASS). They are available online at: hftp://www.larimer.org/engineeiing/GMARdStds/UrbanSt.htm 6. This project is responsible for dedicating any right-of-way and easements that are necessary for this project. For Shields Street there appears to be approximately 40 feet of existing right-of-way for the west half of this street. If accurate at 40 feet, an additional 11 feet of right-of-way is required to be dedicated in order to meet the constrained arterial standard half right-of-way width of 51'. In addition to the right-of-way dedication for Shields Street, an additional 15' utility easement behind the right-of-way is required for dedication. Along Springfield Drive, a 9' utility easement behind the existing right-of-way should be dedicated. 7. The detached sidewalk should be placed such that the back of walk coincides with the existing right-of-way in Springfield Drive and proposed right-of-way on Shields Street, with appropriate transitions to the south and west respectively. Sidewalk on Springfield Drive should be at a minimum of 4.5 feet and sidewalk on Shields Street should be at a minimum of 6 feet per LCUASS. Note that sidewalk being installed is not eligible for street oversizing reimbursement. 8. Access ramps in accordance with LCUASS criteria are required to be provided at the Springfield Drive/Shields Street intersection. 9. With the existing Hollywood type curb gutter sidewalk on Springfield Drive, the curb and gutter would need to be replace and built to a vertical curb standard. 10. The drive approach should be narrowed such that it comprises solely of the drive aisle width. The additional width for what appears to be a trash location to back into off of Springfield Drive needs to be reconfigured such that access is from the west, not the north. 11. A sight distance easement might be needed for the drive access to Springfield Drive in accordance with sight distance criteria specified in the LCUASS. 12. Chapter 19 of LCUASS specifies setback requirements from the public street to the first parking stall(s) in a drive aisles. The standard may require the removal of parking stalls depending upon information generated regarding the development's traffic generation. 13. Construction plans will be required and a Development Agreement will likely be required and recorded once the project is finalized with recordation costs paid for by the applicant. 14. A Development Construction Permit (DCP) will need to be obtained prior to starting any work on the site. Electric Engineering Contact: Alan Rutz, 970-224-6163, arutz(&-fcgov.com 6 Comment Letter Generated: 6/8/2011 at 2:11 pm • • Community i0opment and Neighborhood Services Foof 281 North College Avenue rt Collins pa Box 580 Fort Collins, CO 80522 970.221.6760 970.224.6134 - fax fcgov.com Fire Authority Contact: Ron Gonzales, 970-221-6635, rgonzales(ftoudre-fire.org 1. 1. FIRE SPRINKLERS Because this is a 50 unit, 3-story + bassement , MF R-Occupancy (student housing) project, fire sprinklers are required. A remote fire department connection will be required. 2. 2. FIRE LANE If the 3-story building exceeds a 30-foot height, then a fire lane at least 26' in width is rerquired. 06 IFC APPENDIX D105. If the fire lane exceeds 150' in length, a turnaround will be required with a 50' radius. 3. 3. WATER SUPPLY A fire hydrant is required to be located within 300' of the building ... to supply 1500 gpm at 20 psi Environmental Planning Contact: Lindsay Ex, 970-224-6143, lex(&fcgov.com 1. The applicant should make note of Article 3.2.1(C) that requires developments to submit plans that "...(4) protects significant trees, natural systems, and habitat". Note that a significant tree is defined as a tree having DBH (Diameter at Breast Height) of six inches or more. As several of the trees within this site appear to have a DBH of greater than six inches, a review of the trees shall be conducted with Tim Buchanan, City Forester (221-6361) to determine the status of the existing trees and any mitigation requirements that could result from the proposed development. 2. With respect to landscaping and design, the City of Fort Collins Land Use Code, in Article 3.2.1 (E)(2)(3), requires that you use native plants and grasses in your landscaping or re -landscaping and reduce bluegrass lawns as much as possible. Reveille Bluegrass is one option for having bluegrass lawns and using less water. Engineering Development Review Contact: Marc Virata, 970-221-6567, mvirataojcgov.com 1. Larimer County Road Impact Fees and Street Oversizing Fees are due at the time of building permit. Please contact Matt Baker at 224-6108 if you have any questions. 2. The City's Transportation Development Review Fee (TDRF) is due at the time of submittal. For additional information on these fees, please see: hftp://www.fcgov.com/engineering/dev-review.php 3. Any damaged curb, gutter and sidewalk existing prior to construction, as well as streets, sidewalks, curbs and gutters, destroyed, damaged or removed due to construction of this project, shall be replaced or restored to City of Fort Collins standards at the Developer's expense prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 5 Comment Letter Generated: 6/8/2011 at 2:11 pm • Community Apment and Neighborhood Services City of 281 North College Avenue Fort Collins Po Box 580 Fort Collins, CO 80522 970.221.6760 970.224.6134 - fax /cgov.com S. The design of this site must conform to the drainage basin design of the Old Town Master Drainage Plan as well the City's Design Criteria and Construction standards. 6. The city wide Stormwater development fee (PIF) is $6,313.00/acre ($0.1449/sq.ft.) for new impervious area over 350 sq.-ft., and there is a $1,045.00/acre ($0.024/sq.ft.) review fee. No fee is charged for existing impervious area. These fees are to be paid at the time each building permit is issued. Information on fees can be found on the City's web site at http:/twww.fcgov.com/util ities/b usiness/bu i lders-and-developers/plant-investment-developm ent-fees or contact Jean Pakech at 221- 6375 for questions on fees. There is also an erosion control escrow required before the Development Construction permit is issued. The amount of the escrow is determined by the design engineer, and is based on the site disturbance area or erosion control measures shown on the site construction plans. Historical Preservation Contact: Karen McWilliams, 970-224-6078, kmcwilliamsCa_fcaov.com 1. The existing structures at 1305 and 1319 S Shields were reviewed against Section 14-28 of the Municipal Code and the following determinations were made: 1305 S Shields - Front Single Family Residence - Determined to be individually eligible for Local Landmark Designation - The proposed demolition will impact that eligibility. 1305 S Shields - Additional Rear Residence - A split decision was rendered regarding the individual eligibility, the final decision maker would be the Landmark Preservation Commission. Contact Karen McWilliams at kmcwilliams@fcgov.com if you would like to bring this item to that or a later meeting. 1319 S Shields - A split decision was also rendered regarding the individual eligibility of this structure. The final decision maker would be the LPC as outlined above. Please follow the same instructions to determine this structure's eligibility. A process flowchart is available at http://www.fcgov.com/historicpreservation/pdf/ht_flowchart_3. pdf 2. Since one structure has been determined to be eligible for local landmark designation, the project will need to comply with Section 3.4.7 of the Land Use Code. 3. You will need to contact me via e-mail or phone to set up a Design assistance meeting with the Landmark Preservation Commission sub -committee. This meeting will help consider appropriate designs that will help this project better meet the requirements of Section 3.4.7 of the Land Use Code Forestry Contact: Courtney Rippy, 970-416-2283, criaaya(U.fcgov.com 1. Please contact Tim Buchanan, City Forester, for more information regarding the existing trees on site. His number is (970) 221-6361 and e-mail is tuchanan@fcgov.com 4 Comment Letter Generated: 6/8/2011 at 2:11 pm Community0okpment and Neighborhood Services City of 281 North College Avenue Fort Collins PO Box 580 Fort Collins, CO 80522 970.221.6760 970.224.6134 - fax fcgov.com density is greater than 24 dwelling units per acre, then this will be a Type 2. Based on information provided at the Conceptual Review meeting, approximately 50 units are anticipated to be proposed, which would require a Type 2, Planning and Zoning Board public hearing. Water -Wastewater Engineering Contact: Roger Buffington, 970-221-6854, rbuffington(&fcgov.com 1. Existing water mains and sanitary sewers in the area include a 6-inch water main and a 15-inch sewer in Shields and a 6-inch water main and a 10-inch sewer in Springfield. 2. All water and sewer lines extending to the site must be used or abandoned at the main. 3. The water conservation standards for landscape and irrigation will apply. Information on these requirements can be found at: http://www.fcgov.com/standards 4. Development fees and water rights will be due at building permit. Credit will be given for services where accounts have previously been established. Transportation Planning Contact: Aaron Iverson, 970-416-2643, aiverson(cDfcgov.com 1. Springfield is identified as a designated bike route to Shields. 2. The conceptual plan doesn't show the crosswalk configuration across Springfield, we will want to make sure this is done to current city standards Stormwater Engineering Contact: Glen Schlueter, 970-224-6065, gschlueter(a_fcgov.com 1. It is important to document the existing impervious area since drainage requirements and fees are based on new impervious area. An exhibit showing the existing and proposed impervious areas is required. 2. In the Old Town drainage basin a drainage and erosion control report and construction plans are required if there is an increase in impervious area greater than 5000 square feet. They must be prepared by a Professional Engineer registered in Colorado. 3. The drainage outfall for the site is the inlet at the southwest corner of the intersection of Springfield Dr. and Shields St as discussed in the drainage narrative. 4. Water quality treatment is also required as described in the Urban Storm Drainage Criteria Manual, Volume 3 - Best Management Practices (BMPs). Extended detention is the usual method selected for water quality treatment; however the use of any of the BM Ps is encouraged. (http://www.udfcd.org/downloads/down_cdtmanual_volill.htm) All of the methods described in the drainage narrative are acceptable especially the use of permeable pavers since that is also a Low Impact Development (LID) practice. 3 Comment Letter Generated: 6/8/2011 at 2:11 pm Community Dikpment and Neighborhood Services City of 281 North College Avenue Fort Collins PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov.com CONCEPTUAL REVIEW STAFF COMMENTS Meeting Date: September 19, 2011 Item: 1305 and 1319 S. Shields St. - Student Housing Applicant: Chuck Bailey 7302 Rozena Dr. Longmont, CO 80503 chades.baileyl @comcast.net Land Use Data: This is a request to demolish two existing single family dwelling units at 1305 and 1319 S. Shields St. and develop five (5), residential scaled buildings with a mix of 1, 2 and 3 bedroom student rental apartments plus 69 off-street parking spaces for the proposed community. Each building is estimated to have 10 dwelling units for a total estimate of 110 beds. The site is zoned NCB, Neighborhood Conservation Buffer. Comments: Zoning Contact: Peter Barnes, 970-416-2355, pbarnes(&fcaov.com 1. The property is in the TOD overlay zone. This means that no parking is required. However, we encourage the developer to provide as much parking as possible. 2. 3 handicap parking spaces will be required for a parking lot with 69 total spaces. Need to provide bike parking as well. 3. Need to show/label trash enclosure location. If the object shown on the site plan just off of Springfield at the driveway entrance is a trash enclosure, the dumpster must be totally screened from view. If this is the intended location, it's not ideal because tenants may stop their car in the driveway when leaving or entering the project to deposit trash. Also, the enclosure is required to be at least 20' from a public sidewalk. 4. The NCB zone has two lot area to floor area ratio requirements. The overall lot area has to be at least as large as the total floor area of all buildings. This appears to be met. The floor area ratio of the rear 50% of the lot (the west half) is limited to .33 (i.e. if the rear half lot area is 30,000 s.f., then the maximum floor area allowed in the rear half is 9900 s.f. S. The project description doesn't indicate how many dwelling units are proposed. The number of units deterimines whether this project will be subject to a Type 1 or a Type 2 review. If the density is 24 dwelling units per acre or less, then this will be a Type 1. If the 2 Comment Letter Generated: 6/8/2011 at 2:11 pm City of �Fort Collins June 08, 2011 Chuck Bailey 7302 Rozena Dr. Longmont, CO 80503 RE: 1305 and 1319 S. Shields St. - Student Housing Dear Chuck, Community Development and Neighborhood services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax Icgov.com Attached, please see a copy of Staff's comments concerning the request referred to as the 1305 and 1319 S. Shields St. - Student Housing, which was presented before the Conceptual Review Team on September 19, 2011. The comments offered informally by staff during the Conceptual Review will assist you in preparing the detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you should have any questions regarding these comments or the next steps in the review process, please feel free to contact me at 970-416-2283. Sincerely, Courtney Rippy City Planner 281 North College Avenue - P.O. Box 580 - Fort Collins, CO 80522 - 0580 -- (970) 221-6750 - FAX (970) 224-6134