HomeMy WebLinkAbout800, 808 & 814 W. PROSPECT RD. MIXED-USE (OBSERVATORY PARK) - PDP - 41-02A - CORRESPONDENCE - (27)Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Sincerely Ted Shepard Chief Planner Enc. Page 6 Number: 89 Created: 81912004 [2/25/05] [819104] Confirm with PFA concerning the 4-inch fire line being adequately sized. Noted. Coordination with the PFA will be coordinated once the pressure is known, and the fire line will be sized adequately to meet PFA standards. Number.- 91 Created: 8/9/2004 [2/25/051 Provide separate water and sewer services for each use proposed within the building (i.e. commercail and residential). Maintain the required landscape/utility separation distances on the landscape plans. [819104] See site, landscape and utility plans for other comments. Corrected, trees and shrubs have been moved appropriate distance from water and sewer lines. Department: Zoning Issue Contact: Jenny Nuckols Topic: Zoning Number. 27 Created. 511112004 (2/8/05] See land use code section 3.2.1(E)($)(b) [51111041 Landscaping is only being shown around a portion of the parking lot perimeter, please not the rest and call out the plants and counts. Corrected, plant counts are shown on the plan and in the plant legend. A portion of the west perimeter has a concrete drain pan, and it is not feasible to provide planting in this area. A privacy fence will be installed along the west property boundry. Comments From Current Planning 1. Staff is concerned about the entrance and compliance with Section 4.24(D)(1)(a). This standard calls for doorways to face the street at grade level or slightly elevated. In order to mitigate the fact the entrance is below grade, please explore design treatments that would make this entrance more prominent and visible to Prospect Road. Z See redline Preliminary Site Plan regarding adding more explanatory notes describing the size and location of the resident common area and the mixed -use area. Corrected, refer to site plan. 3. Is the emergency access through Hi -Lan Apartments restricted to emergency access only? Please explain on the plans how the bicycles and pedestrians are allowed access but cars are restricted. Will there be a gate, bollards or chain? If cars are not restricted, then it would be helpful to see the diagram of the Hi -Lan parking lot. Corrected, refer to site plan. Residents of the 808 W. Prospect project will be allowed to cross the Hi -Lan apartments as pedestrians, or walking their bicycles to access Lake St. and on to the CSU Campus. Vehicles will not be allowed to travel to Lake Street. An emergency access gate will be installed between the two properties. Please see redline comments on the architectural elevations. Page 5 Number. 135 Created: 2/23/2005 [2/23/051 The water quality ponds should not have micro pools and be designed to be dry extended detention. Mosquitoes and the wet mess will be a complaint to the City waiting to happen. Micropools have been taken out. Number. 136 Created: 2/23/2005 [2/23/051 Please provide more spot elevations along the north property line to show grading and proper freeboard required for the detention pond. Corrected. Number: 156 Created. 212512005 [2125105] A drainage easement dedicated to the City is required for the pond's outfall pipe to the north. This is now shown. Topic: Erosion/Sediment Control Number. 133 Created: 2/23/2005 [2/23/051 Plan is OK. Department: Transportation Planning Issue Contact: David Averill Topic: Drainage Number. 165 Created: 212812005 [2122105] How does the applicant propose to meet Bicycle/Pedestrian LOS standards with this new access design off of Lake St? It would appear that the favorable finding in the TI S (which states the LOS for both modes to be 'B" or better for the CSU destination area) needs to be revisited with this change. Corrected, see comment above, no 63. A letter with full explanation has also been submited [21281051 Follow up comment: a project came into Conceptual Review this morning for the parcel immediately east of this project. It is suggested that this applicant explore solving the bike/ped/vehicular access puzzle for this site with the parties to the east. The developer of this project has not yet secured access to Lake Street to date, and is not working with this project. Department: Water Wastewater Issue Contact: Jeff Hill Topic: General Number. 86 Created: 81912004 (2125105] [8191041 Provide a minimum of 10 feet of utility easement on both sides of the proposed sanitary sewer service for this project. Provide copies of the required offsite utility easements for our review. 20' easement is now shown. Page 4 the bike LOS to CSU. However, it must be designed to City standards so it can safely accommodate both bikes and pedestrians. Topic: Utility plans Number: 16 Created. 5/6/2004 [2/21/051 The ramp still does not meet the detail. Please revise and show spot elevations to ensure that ADA requirements are being met. Also, Truncated Domes need to be added to these ramps to meet current ADA standards. [8151041 The ramp on the west side of the driveway needs to meet the detail below. Please revise. [516104] See detail 707 for the correct construction of the driveway. The driveway radii should be dimensioned and meet LCUASS standards. 5 Scale ramp details are now shown. Number: 95 Created: 212112005 [2121105] Please provide letters of intent from the adjacent property owner for the proposed offsite utility and emergency access easements (and any other easements needed) prior to scheduling a public hearing. Department: Stormwater Utility Issue Contact: Wes Lamarque Topic: Drainage Number: 35 Created: 511812004 [21231051 [81101041 The TOW elevation is constant, but please provide BOW elevations periodically along the wall. Please provide TOW and BOW elevations for all retaining walls periodically along the length. BOW elevations are shown. Number. 37 Created: 511812004 [2/23/051 Need this before a hearing. [8110104] The sizing of the detention ponds is correct. A stage - storage table is needed to verify that the grading shown on the plans will provide the volume that is being proposed. Please provide a stage -storage table in the drainage report for the detention pond Provided. Number. 93 Created. 811012004 [2/23/05] [8110104] After hearing, a more detailed review will take place when 90% plans are submitted. Acknowledged. Number: 134 Created: 212312005 [2/23/051 The 8-inch outlet pipe is smaller than the minimum of 15-inches allowed. Clogging of this small pipe is likely over a short amount of time. A discussion needs to take place of all alternatives between the City and engineer. A 12" pipe is now shown. Page [815104] The emergency access easement near the building should be 30' wide to match the fire lane width. Topic: Site and Landscape plans Number: 7 Created: 5/6/2004 [2121105] The easements are shown differently on the plat and site plan and utility plans still. The EAE is required to be 30' wide for servicing buildings that are 3 or more stories tall. The drive aisle provided on the north side of the building is 30' wide, but the easement within it is only 20'. Please check with PFA to ensure that the drive aisle along the west side of the building doesn't need to be 30' wide as well. The new offsite EAE needs to meet the minimum radius requirements on the curves (25' interior, 50' exterior) unless specific approval is gotten from PFA for the smaller curves. Corrected, PFA has reviewed the site plan and has accepted what is shown. [84VO4] Please match the emergency access easement shown on the plat/utility plans/site and landscape plans. [5161041 Show the emergency access easement. Number. 80 Created: 8/5/2004 [21211051 (8/5/04] Please show the existing curb and gutter location. Corrected. Topic: Transportation Number.63 Created. 512112004 (2/21/05] How will this project meet its bike and ped LOS standards now that the bike/ped path to Lake Street is gone? Pedestrians and bicyclist will be allowed to access Lake Street through the Hi -Lan apartment site. A letter from the Hi -Lan owner / management will provide details of the agreement between the property owners to this affect. [8151041 Revised comment (David Averill, Transportation Planning): If the proposed drive out to Lake Street is to have bollards on both ends and is to be restricted to emergency use only, then the paved section of that drive (minimum 8' wide) could double as the required ped/bike path out to Lake Street. [51211041 Comment From Tom Reiff. [5119104] According to the applicant's planning objectives, the path out to Lake Street will serve as a connection for bikes and pedestrians from the proposed development to CSU. To safely accommodate both bikes and peds and to meet the City's design standards the path needs to be a minimum 8 feet in width (LUC 3.6.3 & 3.2.2). Number: 66 Created: 5/21/2004 [2/21/05] [815104] See comment #63. [5121104] Comment from Tom Reiff.[5/19/04] The submitted TiS is incorrect in stating that there are no bicycle destinations within a quarter mile. According to the City's Level of Service (LOS) Manual, public schools are considered a destination which includes CSU. Since there are no on -street bike lanes connected to this site to satisfy the LOS, it would be acceptable to allow the proposed path connection to Lake Street and its bike lanes to satisfy Page 2 0 STAFF PROJECT REVIEW Cih nt Furt Collin. EASTPOINT STUDIO Date: 03/02/2005 DON BROOKSHIRE 3207 KITTERY CT. FT. COLLINS, CO 80526 Staff has reviewed your submittal for 800, 808 AND 814 W PROPSECT ROAD EXPANDED CONDOMINIUM PROJECT PDR and we offer the following comments: Response to Comments &ROU*3 Department: Engineering Issue Contact: Katie Moore Topic: Drainage Number 97 Created: 2/21/2005 [21211051 When repaving/regrading the offsite parking lots, the drainage must be diverted from flowing over the public walk. Please re -grade to drain to an under -walk drain. This has been addressed with the proposed trench drain. Topic: General Number: 19 Created: 51612004 [21211051 [8151041 Repeat FYI. [516104] Please see redlines and utility plan checklist for further comments. Acknowledged. Number.- 77 Created: 8/5/2004 [2/21/051 [8151041 Please reivew LCUASS Appendix E for scanning requirements for all plans. Corrected. Number.78 Created: 81512004 [2121105] W51041 Please clearly identify ROW being dedicated by this project on the Site plan, and utility plans. Corrected. Number- 96 Created: 212112005 [2121105] Please show the parking configuration of the parking lot offsite to the north to show that parking stall and drive aisle standards will be met. Corrected, and a new parking lot striping is shown on the site plan. Topic: Plat Number: 10 Created: 51612004 [2121105] [815104] Please correct a few remaining typos. [5161041 Please correct the plat language (as redlined). And please correct the vicinity map. Number. 76 [2/21/051 See comment #7. Created.- 8/5/2004 Page I