Loading...
HomeMy WebLinkAboutCSU - WASHINGTON SCHOOL - APU - SPA110001 - CORRESPONDENCE - (5)City of ort Co ins 9. Construction plans will be needed for this project. 10. A Development Agreement will be required with this project. 11. A Development Construction Permit (DCP) must be obtained prior to starting any work on site. CURRENT PLANNING Contact: Ted Shepard, 970-221-6343, tsheaard(&fcaov.com 1. The proposed addition of permitted use is subject to Section 1.3.4 Addition of Permitted Uses, of the LUC. The proposed use is subject to a Type 2 (Planning and Zoning Board) review and public hearing. The applicant for this development request will be required to hold a neighborhood information meeting prior to formal submittal of the project. Type 2 development proposals are subject to the neighborhood meeting requirement, per Section 2.2.2 of the LUC. Please contact me at 221-6750, to assist you in setting a date, time, and location for a meeting. A planner and possibly other City staff, would be present to facilitate the meeting. 2. Please see the Development Review Guide at www.fcgov.com/drg. This online guide features a color coded flowchart with comprehensive, easy to read information on each step in the process. This guide includes links to just about every resource you need during development review. 3. This development proposal will be subject to all applicable standards of the Fort Collins Land Use Code (LUC), including Article 3 General Development Standards. The entire LUC is available for your review on the web at hftp://www.colocode.com/ftcollins/landuse/begin.htm. 4. If this proposal is unable to satisfy any of the requirements set forth in the LUC, a Modification of Standard Request will need to be submitted with your formal development proposal. Please see Section 2.8.2 of the LUC for more information on criteria to apply for a Modification of Standard. 5. Please see the Submittal Requirements and Checklist at: hftp://www.fcgov.com/currentplanning/submiftals.php. 6. The request will be subject to the Development Review Fee Schedule that is available in the Community.Development and Neighborhood Services office. The fees are due at the time of submittal of the required documents for the appropriate development review process by City staff and affected outside reviewing agencies. Also, the required Transportation Development Review Fee must be paid at time of submittal. 7. When you are ready to submit your formal plans, please make an appointment with Community Development and Neighborhood Services at (970)221-6750. Page 6 of 6 �rt o` Co ins fire -alarm system. Knox Boxes are required to be installed approximately 60 inches above grade and no higher than 72 inches above grade. 2006 International Fire Code 506.1; PFA BUREAU POLICY 88-20 6. FIRE DEPARTMENT CONNECTION Fire department connections shall be installed remote from the buildings, and located on the street or fire lane side of buildings, fully visible and recognizable from the street or nearest point of fire department vehicle access or as otherwise approved by the fire code official. 2006 International Fire Code 912.2 and PFA Fire Prevention Bureau Policy 7. FIRE LINE REQUIREMENT Buildings that are required to be fire sprinklered shall have a minimum 6-inch fire line unless hydraulic calculations can support a smaller fire line. NFPA 13 (2007) 23.1.3 8. COMMERCIAL COOKING FIRE EXTINGUISHING SYSTEM With the production of grease -laden vapors, an approved, automatic fire -extinguishing system shall be provided for the protection of commercial -type cooking equipment. 2006 Intemational Fire Code 904.2.1; 609.2; 904.11.2 ENGINEERING DEVELOPMENT REVIEW Contact: Marc Virata, 970-221-6567, mvirata(a)fcgov.com 1. Larimer County Road Impact Fees and Street Oversizing Fees are due at the time of building permit. Please contact Matt Baker at 224-6108 if you have any questions. 2. Transportation Development Review Fee (TDRF) is due at the time of submittal. For additional information on these fees, please see hftp://www.fcgov.com/engineering/dev-review.php 3. Any damaged curb, gutter and sidewalk existing prior to construction, as well as streets, sidewalks, curbs and gutters, destroyed, damaged or removed due to construction of this project, shall be replaced or restored to City of Fort Collins standards at the Developer's expense prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 4. Please contact Joe Olson and Transportation Planning to schedule a scoping meeting and determine if a traffic study is needed for this project. 5. All public improvements must be designed and built in accordance with the Larimer County Urban Area Street Standards (LCUASS). 6. This project is responsible for dedicating any right-of-way and easements that are necessary for this project. Known dedications are for Shields Street, as this roadway is identified as a 4 lane arterial and also a project on the City's Prioritized Bicycle Capital Improvement Project List to add bike lanes. 7. Section 3.6.2(J)(2) would require that as part of the development proposal that the alley behind the property be paved, with design and construction of the alley required by the applicant. 8. Sidewalk along Scott Street would need to be constructed by the applicant in accordance with Larimer County Urban Area Street Standards. Page 5 of 6 Cdy of ort Co ins facility, 5 or more persons) OR an A-3 if all occupants are capable of self-preservation without staff assistance. Because of the change in occupancy, the structure shall be brought up to current fire code requirements. 2. AUTOMATIC FIRE SPRINKLERS Fire sprinklers are required in all Group I occupancies, and Group A-3 occupancies that are more than 12,000 SF, have an occupant load of 300 or more, or any fire areas that are located on a floor other than the level of exit discharge. 3. WATER SUPPLY Fire hydrants, where required, must be the type approved by the water district having jurisdiction and the Fire Department. Hydrant spacing and water flow must meet minimum requirements based on type of occupancy. Minimum flow and spacing requirements include: - Commercial and multi -family dwellings 1,500 gpm at 20 psi residual pressure, spaced not further than 300 feet to the building, -on 600-foot centers thereafter - Residential within Urban Growth Area, 1,000 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter - Residential outside Urban Growth Area, 500 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter. These requirements may be modified if buildings are equipped with automatic fire sprinkler systems. 2006 International Fire Code 508.1 and Appendix B 4. REQUIRED ACCESS Fire access roads (fire lanes) shall be provided for every facility, building or portion of a building hereafter constructed or moved into or within the PFA's jurisdiction when any portion of the facility or any portion of an exterior wall of the first story of the building is located more than 150 feet from fire apparatus access as measured by an approved route around the exterior of the building or facility. This fire lane shall,be visible by painting and signage, and maintained unobstructed at all times. A fire lane plan shall be submitted for approval prior to installation. In addition to the design criteria already contained in relevant standards and policies, any new fire lane must meet the following general requirements: - Be designed as a flat, hard, all-weather driving surface (asphalt or concrete) capable of supporting fire apparatus weights. Compacted road base shall be used only for temporary fire lanes or at construction sites. - Have appropriate maintenance agreements that are legally binding and enforceable. - Be designated on the plat as an Emergency Access Easement. - Maintain the required minimum width of 20 feet throughout the length of the fire lane (30 feet on at least one long side of the building when the structure is three or more stories in height). If the building is equipped throughout with an approved automatic fire -sprinkler system, the fire code official is authorized to increase the dimension of 150 feet. 2006 International Fire Code 503.1.1, 503.2.3, 503.3, 503.4 and Appendix D 5. KEY BOXES REQUIRED Poudre Fire Authority requires a key box (6Knox Box6) to be mounted in approved location(s) on every new building equipped with a required fire -sprinkler system or Page 4 of 6 ort Co ins permit. 5. A grease interceptor may be required. STORMWATER ENGINEERING Contact: Glen Schlueter, 970-224-6065, cischlueter(cDfcgov.com 1. It is important to document the existing impervious area since drainage requirements and fees are based on new impervious area. An exhibit showing the existing and proposed impervious areas is required. 2. In the Old Town drainage basin a drainage and erosion control report and construction plans are required if there is an increase in impervious area greater than 5000 square feet. These must be prepared by a Professional Engineer registered in Colorado. If there is less than 5000 square feet of new impervious area, a drainage letter should be sufficient to document the existing and proposed drainage patterns. The 5000 square feet of new impervious area is a one time allowance and is cumulative over time so it is important to document it. A grading plan is required for all new construction with over 350 square feet of new impervious area. 3. If there is an increase in impervious area greater than 5000 square feet, onsite detention is required with a 2 year historic release rate for water quantity. Parking lot detention for water quantity is allowed as long as it is not deeper than one foot. If the gravel parking lot is paved it will require detention and water quality treatment. If the site is subdivided into more lots, the detention area for the lots needs to be in a separate track of land (not on a private lot) that is owned and maintained by all lots draining to it. 4. Water quality treatment is also required as described in the Urban Storm Drainage Criteria Manual, Volume 3 - Best Management Practices (BMPs). Extended detention is the usual method selected for water quality treatment; however the use of any of the BMPs is encouraged. 5. There is a storm sewer in Shield St. if there is a need for a deeper drainage outlet. 6. The design of this site must conform to the drainage basin design of the Old Town Master Drainage Plan as well the City's Design Criteria and Construction standards. 7. The city wide development fee (PIF) is $6,313.00/acre ($0.1449/sq.ft.) for new impervious area over 350 sq.ft., and there is a $1,045.00/acre ($0.024/sq.ft.) review fee. No fee is charged for existing impervious area. These fees are to be paid at the time each building permit is issued. Information on fees can be found on the City's web site at http://www.fcgov.com/utilities/builders-fees.php or contact Jean Pakech at 221- 6375 for questions on fees. FIRE AUTHORITY Contact: Carle Dann, 970-219-5337, CDANN[aaoudre-fire.ora 1. OCCUPANCY TYPE The proposed occupancy type will change from an E (Education) to either an 1-4 (day care Page 3 of 6 CONCEPTUAL REVIEW STAFF COMMENTS Meeting Date: September 13, 2010 Item: Washington School - 223 South Shields Street Applicant: Tom Kalert 318 East Oak Fort Collins, CO 80521 Land Use Data: City of F6rt Collins This is a request for a change of use from an educational facility to an adult day respite care (Elderhaus) facility. Any improvements made to the building (ADA accessibility, etc) will respect the Secretary of the Interior's Standards for the Treatment of Historic Properties. The site is zoned NCL and the use is not permitted within the NCL District, so an "Addition of a Permitted Use" will be necessary. Comments: ZONING Contact: Peter Barnes, 970-416-2355, pbarnesna fcgov.com 1. The property is located in the NCL zone. An 'adult day/respite care' use isn't allowed in the zone. Therefore, this use will require approval as an "addition of a permitted use", which will have to be processed as a Type 2, Planning and Zoning Board review. 2. The change of use will require that the property be brought into compliance with teh applicable regulations of the Land Use Code (i.e. parking lot, landscaping, etc.). WATER -WASTEWATER ENGINEERING Contact: Roger Buffington, 970-221 6854, rbuffington(a)fcgov.com 1. Existing water and sewer mains in the area include a 10-inch water main and a 10-inch sewer in Shields, a 6-inch water main and an 8-inch sewer in Olive, a 4-inch water main in Scott and an 8-inch sewer in the alley to the north. 2. The existing water service to this property is a 2-inch service. 3. If new lots fronting on Scott Avenue are created, a sanitary sewer must be installed in Scott, and utility plans will be required. 4. If there is a change to the existing water and sewer services or additional services are needed for newly created lots, development fees and water rights will be due at building Page 2 of 6 lK FCf ort Collins . September 13, 2010 Tom Kalert 318 East Oak Fort Collins, CO 80521 RE: Washington School - 223 South Shields Street Dear Tom, Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6760 970.224.6134 - fax kgov. com/cunentplanning Attached, please see a copy of Staffs comments concerning the request referred to as the Washington School - 223 South Shields Street, which was presented before the Conceptual Review Team on September 13, 2010. The comments offered informally by staff during the Conceptual Review will assist you in preparing the detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you should have any questions regarding these comments or the next steps in the review process, please feel free to contact me at 970-221-6343. Sincerely, Ted Shepard City Planner 281 North College Avenue - P.O. Box 580 - Fort Collins, CO 80522 - 0580 — (970) 221-6750 - FAX (970) 224-6134