HomeMy WebLinkAboutATRIUM SUITES - MOD - 7-04 - CORRESPONDENCE -22. There are two fees assessed by the Parks and Recreation Department at the time of
building permit for Community Parkland and Neighborhood Parkland Development.
Again, these fees are adjusted annually.
23. The Department of Natural Resources advises that any existing trees be preserved to the
maximum extent feasible. If any trees are to be removed, then mitigation trees must be
provided. The construction phase will require a Fugitive Dust Permit from the Larimer
County Health Department. Also, trash enclosures should be sized to accommodate
various containers for recycling. A single trash hauler should be used. For further
information on natural resource issues, please contact Doug Moore, 221-6750.
24. Utility Plans will be needed at the time of submittal. A Development Agreement will be
required prior to recording final documents. A Development Construction Permit will be
required prior to beginning site work. For further information, please contact Katie
Moore., 221-6605.
25. Additional right-of-way for Laurel Street may be needed. Laurel is classified as a
constrained arterial with a total right-of-way of 102 feet. The project must dedicate
sufficient right-of-way so that there is 51 feet from centerline of the roadway to the
property line. In addition, a 15-foot wide utility easement must be dedicated beyond the
property line. Along Sherwood Street, there must be a nine foot wide utility easement
dedicated beyond the property line.
26. If the property is not platted, a plat will be required.
27. Please feel free to schedule pre -submittal meetings with Staff when the architectural
character of the buildings is being designed. Windows, balconies, roofs, wall plane
projections should all be incorporated into the design.
28. A neighborhood meeting will be required. Please contact the Planning Department when
you are ready to proceed to this stage. We will prepare an area notification map. You are
responsible for providing self-adhesive mailing labels for all property owners of record
within the notification area. Also, please provide $0.50 cents per name to cover mailing
expenses.
Credit on the plant investment fees (tap fees) will be allowed for the existing services so
the new services will pay for only the net increase over existing. The water conservation
standards for landscape and irrigation will apply to the project. Development fees and
water rights will be due at time of building permit. For further information, please
contact Roger Buffington, 221-6681.
12. The site will be served by the Poudre Fire Authority. They will require that a fire hydrant
be within 300 feet of the building capable of delivering a minimum of 1,500 gallons per
minute at 20 p.s.i. An automatic fire extinguishing system will be required capable of
delivering 100 p.s.i. to the roof. The parking structure must also be equipped with an
automatic fire extinguishing system as well as a ventilation system. An automatic fire
alarm system will be required. Access roads to buildings must be no less than 30 feet
wide with no less than 25 feet inside and 50 feet outside turning radii. Designated fire
lanes must feature curbs painted red and "No Parking — Fire Lane" signs. The address
must be visible from the public street on which the building fronts. For further
information, please contact Ron Gonzales, 221-6570.
13. According to the Uniform Building Code, if the parking structure is five feet or closer to
the property line, then it must be completely enclosed with a solid wall.
14. The estimated Street Oversizing Fee is $1,120 per dwelling unit and payable at the time
of building permit issuance. Keep in mind fees are adjusted annually. In addition, the
City collects the Larimer County Road Impact Fee. For the exact fee amounts, please
check with Matt Baker, Street Oversizing Administrator, 221-6605.
15. A Transportation Impact Study will be required. Please contact Eric Bracke, Traffic
Operations Engineer, 221-6630, to determine the scope of the study. A T.I.S. must also
address alternative modes such as bike, pedestrian and transit levels of service.
16. A radial driveway design will be needed if there are more than 350 trips per day at the
driveway/Sherwood intersection.
17. An engineering variance will be required to allow the proposed driveway on Sherwood to
be less than the required 175 feet from the Laurel/Sherwood intersection.
18. A double loaded drive aisle in a parking lot must be 24 feet in width.
19. The developer is responsible for the repair of any damaged sidewalk, curb and gutter
along the frontages of the property. For further information regarding engineering issues,
please contact Katie Moore, 221-6605.
20. For an estimate of the Capital Improvement Expansion Fee, payable at the time of
building permit, please contact the Building Inspection Division, 221-6760. Keep in
mind fees are adjusted annually.
21. If there are any overhead utilities on the site, they must be placed underground.
The Code requires multi -family buildings to provide direct connecting walkways to
public streets. In this case, sidewalks would need to be provided to both Laurel and
Sherwood Streets. Please refer to Section 3.2.2 of the Land Use Code.
6. The minimum number of required parking spaces is based on the number of bedrooms
per dwelling unit. For two -bedroom units, there can be no less than 1.75 spaces per unit.
You may want to consider providing special amenities for visible and secured bicycle
parking since the site is close to the C.S.U. campus. Be sure to provide the required
minimum in accordance with Section 3.2.3.
The source of electrical power is from the alley approximately 50 feet north of the lot.
The existing secondary service line that serves the building will probably be inadequate
to serve the proposed structure. The size and location of the transformer and meter must
be coordinated with Light and Power. The transformer must be both accessible (within
ten feet) to hard surface for emergency change -out and screened for aesthetic purposes, if
visible from a public street.
8. A Commercial One ("C-1") Form must be completed by a licensed electrical contractor
to determine entrance capacity. The construction phasing schedule should be coordinated
with Light and Power. Normal electrical development fees and charges will apply. Any
change to the existing electrical system or facilities will be at the developer's expense.
Shade trees will be required in the parkway between sidewalk and curb along Lake
Street. Street trees must be kept 40 feet from street lights and ornamentals must be kept
15 feet from street lights. For further information, please contact Bruce Vogel, 221-6700.
9. This site is in the Old Town drainage basin where the new development fee is
$4,150/acre which is subject to the runoff coefficient reduction and due with building
permit issuance.
10. Onsite stormwater detention is required for the amount of only the new impervious
surface created by the proposed development. For detained flows, the release rate cannot
exceed the two-year historic release rate. There is also a water quality extended detention
requirement to treat the runoff. Storm flows that enter the under -structure parking lot
must be accounted for. Water quality must be done in a grassy area, not on pavement.
The standard drainage and erosion control reports and construction plans are required and
they must be prepared by a professional engineer registered in Colorado. The applicant
will need to consider a pumping system if storm flows are detained in a below -grade area.
Detained storm flows cannot be released across the sidewalk and driveway along
Sherwood Street. Rather, these flows must be released into the street via a pipe. Since
the outfall is the street, this may determine how deep the detention/water quality pond
can be. For further information, please contact Wes Lamarque, 221-6700.
11. There is an eight -inch diameter water main in Laurel. There is a six-inch sanitary sewer
main in Sherwood and an eight -in sewer main in the east -west alley north of the site.
There is no sanitary sewer in Sherwood Street. The developer shall use or abandon
existing services which presently serve the site. Any abandonment shall be at the main.
CONCEPTUAL REVIEW STAFF COMMENTS
of Fort
ITEM: 502 West Laurel Street — Apartment Project
MEETING DATE: January 5, 2004
APPLICANT: Mrs. Barbara Siek c/o Mr. Dana McBride, 1510 Hillside Drive,
Fort Collins, CO 80524.
LAND USE DATA: Request for approximately 28 - 30 two -bedroom multi -family dwelling
units in a three-story structure with a portion of the parking spaces located underneath the
dwelling units on the ground floor. The ground floor would also contain four dwelling units that
face Laurel Street. The balance of the dwelling units would be contained within the upper two
stories. The lot size is 19,200 square feet. The site is located at 502 West Laurel Street at the
northwest comer of Laurel Street and Sherwood Street.
COMMENTS:
The site is zoned N-C-B, Neighborhood Conservation — Buffer District. Multi -family
that is greater than 24 dwelling units per acre is a permitted land use in this zone, subject
to review by the Planning and Zoning Board. The maximum building height is three
stories. If a Modification of Standard is requested, the request must be forwarded to the
Planning and Zoning Board as either a stand-alone request or consolidated into a Project
Development Plan (P.D.P.)
2. The minimum lot area shall be equivalent to the total floor area of the building.
Therefore, if the lot is 19,200 square feet in size, the floor area for the building cannot
exceed 19,200 square feet in area including (or not including) the area on the ground
floor devoted to under -structure parking.
The minimum front yard setback is 15 feet. The minimum rear yard setback is 15 feet.
The minimum side yard setback is five feet for interior side yards except that whenever
any portion of a wall or building exceeds 18 feet in height, such portion of the wall or
building shall be set back from the interior side lot line an additional one foot beyond the
minimum required for each two feet, or fraction thereof, of the wall that exceeds 18 feet
in height. Minimum side yard width shall be 15 feet on the street side of any comer lot.
4. There are a variety of other development standards in the N-C-B zone relating to building
design, site design, landscaping and access. These are found in Section 4.8(E) of the
Land Use Code.
COMMUNITY PLANNING AND ENVIRONMENTAL SERVICES 281N.College Ave. P.O.Box580 Fort Collins, CO 80522-0580 (970)221-6750
CURRENT PLANNING DEPARTMENT
Commu y Planning and Environmental _ .rvices
Current Planning
City of Fort Collins
January 9, 2004
Mr. Dana McBride
1510 Hillside Drive
Fort Collins, CO 80524
Dear Mr. McBride:
For your information, attached is a copy of the Staff s comments for 502 West Laurel Street
Apartment Project which was presented before the Conceptual Review Team on January 5,
2004.
The comments are offered by staff to assist you in preparing the detailed components of the
project application. Modifications and additions to these comments may be made at the time of
formal review of this project.
If you should have any questions regarding these comments or the next steps in the review
process, please feel free to call me at 970-221-6750.