HomeMy WebLinkAboutODELL BREWERY PARKING LOT EXPANSION - PDP - PDP120032 - CORRESPONDENCE - (3)Department: Technical Services
Contact: Jeff County, 970-221.6588, icounty(a fcgov.com
Topic: Construction Drawings
Comment Number: 3 Comment Originated:
11/28/2012
11/28/2012: Please correct the Basis Of Bearings statement on sheet C000.
Comment Number: 4 Comment Originated:
11/28/2012
11/28/2012: Please correct the description on benchmark R402 of sheet COO 1.
Comment Number: 5 Comment Originated:
11/28/2012
11/28/2012: There are line over text issues on sheet C101.
Comment Number: 6 Comment Originated:
11/28/2012
11/2812012: There is a text over text issues on sheet C200.
Topic: General
Comment Number: 1 Comment Originated: 11/28/2012
11/28/2012: This project is on unplatted property. Does this need to be platted?
Topic: Lighting Plan
Comment Number: 2
11/28/2012: The plans need to be 24"x36" in size.
Department: Zoning
Contact: Noah Beals, 970.416-2313, nbeals(a)fcgov.com
Topic: General
n
Comment Originated: 11/28/2012
Comment Number: 1 Comment Originated: 11/28/2012
11/28/2012: The new parking area is not meeting the minimum 1 foot-candle requirement.
Comment Number: 5
Comment Originated: 11/27/2012
11/27/2012: Sheet C101: Which asphalt section is being proposed. It appears that there is
conflicting callouts on this sheet and the detail that is referred to shows two different pavement
sections.
Comment Number: 6
11/27/2012: Sheet C200: Text over text
Comment Originated: 11/27/2012
Comment Number: 7 Comment Originated: 11/27/2012
11/27/2012: Sheet C300: Please label the elevations on the contours from Colorado Iron and
Metal. Additionally add a note or someway to denote that those contours are from another
project and not a part of these plans.
Topic: Easements
Comment Number: 3 Comment Originated: 11/27/2012
11/27/2012: With the preparation of a subdivision plat it maybe worthwhile dedicating
easements for the parking lot on the plat than by separate document.
Topic: Plat
Comment Number: 2
Comment Originated: 11/27/2012
11/27/2012: This area exists on property that has not yet been subdivided. A subdivision plat
will be required to construct the employee parking lot on this piece of property.
Department: PFA
Contact: Jim Lynxwiler, 970-416-2869, ilynxwiler(a)poudre-fire.org
Topic: General
Comment Number: 01
FIRE LANE SPECIFICATIONS
Comment Originated: 11/27/2012
Maintain the required 20 foot minimum unobstructed width & 14 foot minimum overhead
clearance. For structures three stories or more in height: required fire lanes shall be 30 foot
wide minimum on at least one long side of the building.
Fire Lanes shall be designed as a flat, hard, all-weather driving surface capable of supporting
40 tons. They shall be designated on the plat as an Emergency Access Easement.
Department: Stormwater Engineering
Contact: Wes Lamarque, 970-416-2418, wlamargue(aUcgov.com
Topic: General
Comment Number: 1 Comment Originated: 11/30/2012
11/30/2012: Please include a drainage plan in the plan set. The copy attached to the drainage
report is too small to read.
Comment Number: 2 Comment Originated: 11/30/2012
11/30/2012: The detention pond calculations for the north pond were not included in the
drainage report.
r
CRY'-,
�° a
t _ InNIT
_.
Community Development and
Neighborhood Services
H1 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970.224.6134 - fax
fcgov. com/developmentre view
December 03, 2012
Mike Mcbride
1603 Oakridge Drive
Fort Collins, CO 80525
RE: Odell Brewery Parking Lot Expansion, PDP120032, Round Number 1
Please see the following summary of comments from City staff and outside reviewing agencies for your
submittal of the above referenced project. If you have questions about any comments, you may contact the
individual commenter or direct your questions through the Project Planner, Ted Shepard, at 221-6343 or
tshepard@fcgov.com.
Comment Summary:
Department: Current Planning
Contact: Ted Shepard, 970-221.6343,
Topic: General
Comment Number: 1
12/03/2012: Please see redlines.
Comment Number: 2
tshepard(a)fcgov.com
Comment Originated: 12/03/2012
Comment Originated: 12/03/2012
12/03/2012: If the intent is to have low lighting levels, then please address the proposed
lighting under the Alternative Compliance provision that is available under Section 3.2.4(E).
Department:- Engineering Development Review
Contact: Andrew Gingerich, 970-221-6603, aginaerichPfcaov.com
Topic: Construction Drawings
Comment Number: 1 Comment Originated: 11/27/2012
11/27/2012: The construction drawings should include an erosion control plan. Please include
in the set and add to the sheet index.
Comment Number: 4
Comment Originated: 11/27/2012
11/27/2012: Sheet C100: The plan shows removing existing concrete from west side of the
existing building. Does this need to be removed per these plans?