HomeMy WebLinkAboutLARIMER COUNTY MIDPOINT CAMPUS EXPANSION - SPAR - SPA110002 - CORRESPONDENCE - (3)City of F--rt Collins Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov.com 05/24/2011: All I received to review was sheet A-100, the Master Site Plan. If this is the only site plan.that was submitted, it is lacking sufficient detail to comment on. i.e., need to show parking stall and drive aisle dimensions, building footprint or envelope dimensions and setbacks to lot lines, labeled bike racks, trash enclosure locations, parking lot light poles, etc. Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to contact me at 970-221-6343. Sincerely, Ted Shepard Chief Planner 1 Staff Review Letter Generated: 6/13/2011 at 2:03 pm City of Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov.com Number: 2 Issue Originated: 06/07/2011 06/07/2011: Are there any modifications to the water lines in the area between the Sheriffs Office and the Detention Center? If so, schedule a meeting to review the existing water mains, services and fire lines in that area. Number: 3 Issue Originated: 06/07/2011 06/07/2011: On the shallow sanitary sewers, include the design of the insulation (thickness and width) and a specification for the insulation. It must a brand and type that is suitable for underground applications. Number: 4 Issue Originated: 06/07/2011 06/07/2011: Clarify the note on the connection to the existing sanitary sewer MH emphasize that the MH must be core drilled. Number: 5 Issue Originated: 06/07/2011 06/07/2011: At locations where encasement is required on sewers (at crossings with water mains), "EZ Wrap" or similar product may be applied to the sewer joints for encasement. Department: Water -Wastewater Engineering Contact: Roger Buffington, 970-221-6854, rbuffington(cDfcgov.com Topic: Construction Drawings Number: 6 Issue Originated: 06/07/2011 06/07/2011: See redlined plans for other comments. Department: Zoning Contact: Peter Barnes, 970-416-2355, pbarnes(CDfCgov.com Topic: Landscape Plans Number: 1 Issue Originated: 05/24/2011 05/24/2011: Per Sec. 3.2.1(E)(5)(c) of the LUC, each parking lot landscape island must have at least 1 tree. Most shown don't have a tree. Number: 2 Issue Originated: 05/24/2011 05/24/2011: Sec. 3.2.1(E)(5)(e) - The easternmost row of parking has more than 15 parking spaces in a row without an intervening landscape island. Number: 3 Issue Originated: 05/24/2011 05/24/2011: Sec. 3.2.2(E)(4) - the ends of parking aisles should be defined by a landscape island. Many of the end of aisles are defined by a "painted" island. Topic: Site Plan Number: 4 Issue Originated: 05/24/2011 Staff Review Letter Generated: 6/13/2011 at 2:03 pm City of Flirt Collins Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970,224.6134 - fax fcgov.com 06/08/2011: There are many sheets with line over text & text over text issues. Number: 5 Issue Originated: 06/08/2011 06/08/2011: The subtitle on sheet CV01 does not describe the property completely. Number: 6 Issue Originated: 06/08/2011 06/08/2011: Benchmark 2-94's elevation has changed as of the 2008 publishing of the City of Fort Collins Vertical Control Network. Number: 7 Issue Originated: 06/08/2011 06/08/2011: Please change the "County Road 9" references in the benchmark descriptions to "Ziegler Road". Per Resolution 2000-73 the road was renamed. Department: Technical Services Contact: Jeff County, 970-221-6588, icountyftfcgov.com Topic: Landscape Plans Number: 2 06/08/2011: No comments. Topic: Site Plan Number: 1 06/08/2011: No comments. Department: Traffic Operation Issue Originated: 06/08/2011 Issue Originated: 06/08/2011 Contact: Ward Stanford, 970-221-6820, wstanford(cDfcgov.com Topic: Traffic Impact Study Number: 1 Issue Originated: 06/08/2011 06/08/2011: TIS does not review or provide analysis of the existing, background or total conditions related to the Workender program being extended into the weekday. It is adding significant traffic to the area roadways but fails to analyze or contrast how the new traffic will impact the area. The TIS fails to meet typical LCUASS TIS review standards. Department: Water -Wastewater Engineering Contact: Roger Buffington, 970-221-6854, rbuffington(a)-fcgov.com Topic: Construction Drawings Number: 1 Issue Originated: 06/07/2011 06/07/2011: Water service from water main to a point 5 feet downstream of the meter pit must be 2" or 3" (same size as the meter). No 2.5" available. Beyond the meter pit, the size of service may be increased. 3 1 Staff Review Letter Generated: 6/13/2011 at 2:03 pm City of Flirt Collin Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov.com Department: Stormwater Engineering Contact: Wes Lamarque, 970-416-2418, wlamargue(Mcgov.com Topic: General Number: 1 Issue Originated: 06/08/2011 06/08/2011: Please provide HGLs for the storm sewer profiles. Department: Stormwater Engineering Contact: Wes Lamarque, 970-416-2418, wlamargue(CDfcgov.com Topic: General Number: 2 Issue Originated: 06/08/2011 06/08/2011: Class V RCP is probably not necessary, and class 3 can be used. Number: 3 Issue Originated: 06/08/2011 06/08/2011: Please design the outlet structure for the ultimate design with the 1 cfs per acre release. This will prevent from having to alter the outlet structure each time future additions to the campus are proposed. Number: 4 Issue Originated: 06/08/2011 06/08/2011: Please revise wq outlet structure detail. per redlines. Elevations A and B do not correspond to the water quality depth of 2.43 ft. Discussion should take place on the pros and cons of providing a temporary WQ orifice plate or the ultimate plate. Number: 5 Issue Originated: 06/08/2011 06/08/2011: Please revise erosion control notes per redlines. Number: 6 Issue Originated: 06/08/2011 06/08/2011: Please add a riprap detail. Fort Collins requires riprap to be buried with 6 inches of topsoil with temporary erosion control. Number: 7 Issue Originated: 06/10/2011 06/10/2011: The City of Fort Collins has detention pond landscape standards adopted by City Council.. Please review standards and revise ponds accordingly. These standards are located on the City's website. Department: Technical Services Contact: Jeff County, 970-221-6588, icounty(cDfcgov.com Topic: Construction Drawings Number: 3 Issue Originated: 06/08/2011 06/08/2011: The text on sheet DT06 is very bold & hard to read. Can it be toned down? Number: 4 Issue Originated: 06/08/2011 1 Staff Review Letter Generated: 6/13/2011 at 2:03 pm City of Fort Collins Department: PFA Contact: Carie Dann, 970-219-5337, CDANN(cDpoudre-fire.org Topic: General Number: 1 Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov.com Issue Originated: 06/08/2011 06/08/2011: WATER SUPPLY: PFA will require two new hydrants to service the new ASD structure: One to the southwest of the building, another to the northeast. It's difficult to determine if plans currently show one or two new hydrants; UT01 and 02 seem to show a hydrant symbol in one place but a hydrant label in another. General hydrant requirements are below: Fire hydrants, where required, must be the type approved by the water district having jurisdiction and the Fire Department. Hydrant spacing and water flow must meet minimum requirements based on type of occupancy. Minimum flow and spacing requirements include: • Commercial -1,500 gpm at 20 psi residual pressure, spaced not further than 300 feet to the building, on 600-foot centers thereafter These requirements may be modified if buildings are equipped with automatic fire sprinkler systems. 2006 International Fire Code 508.1 and Appendix B Number: 2 _ _ _ _ _ ._ Issue Originated: _06/08/2011 0.6/08/2011: FIRE DEPARTMENT CONNECTION: PFA will allow the FDC for the new ASD to be located on the building, instead of remote. Location TBD and approved by PFA. ALSO, please show locations of FDCs on existing buildings. Number: 3 Issue Originated: 06/08/2011 06/08/2011: TURNING RADII: Minimum turning radii is 25 feet inside, 50 feet outside. Some existing curves are less but new curves must meet 25/50. Number: 4 Issue Originated: 06/08/2011 06/08/2011: EMERGENCY VEHICLE ACCESS: Because this is a county -owned property, we cannot dedicate an emergency access easement to ourself. However, we may consider an emergency access alignment, to ensure access to structures. Can we please meet on site soon to discuss. Number: 5 Issue Originated: 06/08/2011 06/08/2011: HYDRANTS: Several existing hydrants are shown but are not labeled (as #11). Staff Review Letter Generated: 6/13/2011 at 2:03 pm City of Fart Collins Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov.com perhaps the concrete channel can taper the curb height as it approaches the sidewalk in order to not have a raised curb section up against the sidewalk. Number: 12 Issue Originated: 06/08/2011 06/08/2011: There is a potential question posed to our legal staff as to whether the unplatted property that comprises the site would be interpreted as to needing to be platted in conjunction with this review. Number: 13 Issue Originated: 06/08/2011 06/08/2011: Please note that the legal descriptions of the site do not match between the site plan and the construction plan set. Department: Engineering Development Review Contact: Marc Virata, 970-221-6567, mvirata(cDfcgov.com Topic: General Number: 14 Issue Originated: 06/08/2011 06/08/2011: Just as a heads -up, the data on the Larimer County GIS specifies that the parcel of land in which the new ASD building is to be located has a legal description of "East Elizabeth Medical Condo", it -appears to be an error and might be worth correcting. Department: Light And Power Contact: Doug Martine, 970-224-6152, dmartine(cDfcgov.com Topic: General Number: 1 Issue Originated: 05/25/2011 05/25/2011: Relative to the ASD building, Light & Power Engineering will need a Commercial Service Information (C-1) form completed. Will also need to coordinate the location of the electric transformer, and the name/address of who to invoice for the Light & Power Development Charges. Please contact Light & Power Engineering at 221-6700. Number: 2 Issue Originated: 05/25/2011 05/25/2011: Records indicate that the existing electric services to the Sheriffs office and the Comcorr building are each 1200 amps at 277/480 volts. If either of these need to change, please contact Light & Power Engineering to coordinate power requirements and associated costs. 1 Staff Review Letter Generated: 6/13/2011 at 2:03 pm City Of Fort Collins /410 .. Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov.com 06/08/2011: Please coordinate the titles to be consistent on all the drawings, the construction plan set has a different title than the other documents. Topic: General Department: Engineering Development Review Contact: Marc Virata, 970-221-6567, mvirata(cDfcgov.com Topic: General Number: 1 Issue Originated: 06/08/2011 06/08/2011: Ideally, additional right-of-way or access easement should be dedicated to the City to encompass all of the sidewalk along Midpoint (existing and proposed). Currently it appears portions of the existing sidewalk as well as new sidewalk. Number: 2 Issue Originated: 06/08/2011 06/08/2011: It appears that with the attached sidewalk shown on Midpoint Drive as the roadway heads south (though is labeled as detached), relocation of streetlights, fire hydrants, and other utilities would be needed. Out of curiosity, has a detached sidewalk been looked at? It appears there could be room to do an attached sidewalk that would avoid relocation of streetlights, hydrants, and other utilities and perhaps still keep the fence in its present location. Number: 3 - Issue Originated: 06/08/2011 06/08/2011: The access ramps out to Midpoint that are "mid -block" and not at intersections with public streets appears awkward in that there are no access ramps across the street for pedestrians to "receive" and is it preferred to promote these crossing not at intersections? Do these access ramps need to be provided? If these crossings are intended to promote pick-up/drop-off maneuvers, can this be accomplished on -site as Midpoint is not intended to have parking on -street and bike lanes could potentially be added to this roadway. Number: 5 Issue Originated: 06/08/2011 06/08/2011: The conceptual review plans indicated additional storm sewer line installation that would traverse offsite several thousand feet to the future Sharp Point street roadway connection. This was not shown on the construction plan set. Is it no longer under consideration? Number: 6 Issue Originated: 06/08/2011 06/08/2011: It appears that an existing gutter pan that takes parking lot flows and directs it over the existing sidewalk on Midpoint onto a cross pan across Midpoint is being reconfigured into a concrete channel (Sheet SW02) that empties out onto and over the existing sidewalk on Midpoint. It would be ideal if perhaps in conjunction with the concrete channel, a sidewalk chase were installed to direct flows under the walk and not continue to perpetuate nuisance flows over the sidewalk, as noted in 7.7.4 of the Larimer County Urban Area Street Standards. If the applicant is not wanting to provide a sidewalk culvert, 1 Staff Review Letter Generated: 6/13/2011 at 2:03 pm City of F&I C611ins /" Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224,6134 - fax fcgov.com June 13, 2011 Carr Bieker The Architect's Studio 151 W Mountain Avenue Fort Collins, CO 80524 City staff and outside reviewing agencies have reviewed your submittal for Larimer County Midpoint Campus Detension Center Expansion, and we offer the following comments: Department: Engineering Development Review Contact: Marc Virata, 970-221-6567, mvirata(cDfcgov.com Topic: Construction Drawings Number: 4 Issue Originated: 06/08/2011 06/08/2011: The existing conditions, horizontal control, grading and erosion control sheets are missing the portion of area that includes -Where Midpoint Drive starts to -curve from east -west to north -south: Please include this information as it may help to better understand what's occurring with what appears to be a new driveway cut and closure of an existing. Number: 7 Issue Originated: 06/08/2011 06/08/2011: Ideally a vicinity map should be provided on all the sheets, not just the sidewalk plan sheets. Number: 8 Issue Originated: 06/08/2011 06/08/2011: Please replace "Director of Engineering" with "City Engineer" on the utility plan approval block. Number: 9 Issue Originated: 06/08/2011 06/68/2011: The General Notes on the construction plan set need to reflect that it is based upon the 4/1/2007 version. It was last repealed and reenacted on April 1, 2007. Number: 10 Issue Originated: 06/08/2011 06/08/2011: On the existing conditions sheet replace General Note #4 with: "Limits of street repair are approximate. Final limits to be determined in the field by the City Engineering Inspector at the time the streets cuts are made. All repairs to be done in accordance with City standards." Number: 11 Issue Originated: 06/08/2011 Staff Review Letter Generated: 6/13/2011 at 2:03 pm