HomeMy WebLinkAboutMCINTYRE HOUSE (137 & 143 MATHEWS ST.) - PDP/APU - PDP120007 - SUBMITTAL DOCUMENTS - ROUND 1 - (3)Department Engineering Development Review
Contact: MarcYrata, 970-221-6%7, mviratakcfcgcv.com
completed improvements and/or prior to the issuance of the first Certificate of Occupancy.
jPlease contact the City's Traffic Engineer oe Olson ( -6062) to schedule a scoping meeting and
b� determine if a traffic study is needed for this project. In addition, please contact Transportation Planning
( I J . j for their requirements as well.
lA9
5. Any public improvements must be designed and built in accordance with the Latimer County Urban Area
Street Standards (LCUASS). They are available online at:
http://www.larimer.org/engineedng/GMARdStds/LJrbanSt.htm
6. This project is responsible for dedicating any right-of-way and easements that are necessary for this
project. A 9' utility easement behind the existing right-of-way along Mathews Street and an Futility
easement behind the existing right-of-way along the alley is required for dedication in accordance
LCUASS, unless agreed to otherwise by the utility providers.
O/ 7. Figures 7-11 F and 7-12F of LCUASS requires a minimum setback from garage doors to the alley of 8 feet
�� instead of the 6 feet specified.
8. Construction plans may be required and a development agreement may be required with recordation
fees to record the development agreement paid by the applicant once the project is finalized.
9. A Development Construction Permit (DCP) or an excavation permit may be needed to be obtained prior
n -I ////// a to starting
/any
,work on the site for any public infrastructure work.
A0_„Current Planning
ir Contact: Steve Ott, 970-221-6341, soltOfcaov.com
1. Because the applicant wants to create 2 legally platted lots for sales purposes, this requires that the
request for the "single-family attached" use go through the "Addition of Permitted Use" process as set forth
in Section 1.34 and Section 3.5.1 of the Land Use Code. The Planning & Zoning Board is the City authority
on decisions regarding this process.
2. Section 4.9(D)(5) Floor Area Ratio in the Neighborhood Conservation, Buffer District may apply to this
request to create 2 separate lots on the property. Each lot will be subject to the FAR requirement.
3. This development request will be subject to the requirements set forth in Section 4.9(D) Land Use
Standards and Section 4.9 (E) Development Standards in the Neighborhood Conservation, Buffer District of
the Land Use Code.
4. This development request is subject to the applicable General Development Standards asset forth in
Article 3 of the Land Use Code.
5. The proposed development is subject to a Basic Development Review, please contact the Zoning
Department regarding your formal submittal.
Department: Historical Preservation
Contact: Karen McWilliams, 970-224-6078, kmcwilliams(a)fcoov.com
1. This property has already been reviewed under the City's Demolition/Alteration Review Process, City
Code Section 14-72, and found to be individually eligible for Landmark designation.
2. This change of use will not affect the exterior characteristics of the property, and so will not be subject to
reviewed for compliance with LUC Section 3.4.7.
3. However, if any exterior alterations are later proposed, those would be subject to review for compliance
with the Demolition/Alteration Review Process (Section 14-72 of the Municipal Code), and possibly LUC
Section 3.4.7.
4. Properties that are, or become, designated as Fort Collins Landmarks, and/or on the National or State
Registers of Historic Places, qualify for financial incentives, for both interior and exterior work. These
include $15,000 Historic Structure Assessment grants, State Historic Fund grants of $300,000 and more,
both 20% State and 20% Federal Tax Credits, and City no interest loans of up to $7,500 each year.
GtLILnAW Lc�
Department: Fire Authority
Contact: Ron Gonzales, 970-221.6635, raonzales(dpoudre-fire.ora
1. This building will be required to post two addresses, and these numerals shall be visible from the street
Acliiioand posted on a contrasting background.
NO. &OP c� t Pk ovi- wcn � cier s
Department: Environmental Planning 0
Contact: Lindsay Ex, 970-224-6143, lex(&fcoov.com
The applicant should make note of Article 3.2.1(C) that requires developments to submit plans that "... (4)
protects significant trees, natural systems, and habitat". Note that a significant tree is defined as a tree
having DBH (Diameter at Breast Height) of six inches or more. At the rear (west side) of the property, it
appears there may trees on site that have a DBH of greater than six inches. If this is the case, a review of
the trees shall be conducted with Tim Buchanan, City Forester (221.6361) to determine the status of the
existing trees and any mitigation requirements as the result of development impacts.
2. With respect to landscaping and design, the City of Fort Collins Land Use Code, in Article 3.2.1 (E)(2)(3),
� requires that you use native plants and grasses in your landscaping or relandscaping and reduce
ry lre�/ bluegrass lawns as much as possible.
0" Department Engineering Development Review
Contact: Marc Virata, 970-221-6567, mviratata egov.com
1. Latimer County Road Impact Fees and Street Cversizing Fees are due at the time of building permit
Please contact Matt Baker at 224-6108 if you have any questions.
2. The City's Transportation Development Review Fee (TDRF) is due at the time of submittal. For additional
information on these fees, please see: httpllwww.fcgov.com/engineedng/dev-review.php
40* 3. Any damaged curb, gutter and sidewalk existing prior to construction, as well as streets, sidewalks,
curbs and gutters, destroyed, damaged or removed due to construction of this project, shall be replaced
Ac��
or restored to City of Fort Collins standards at the Developer's expense prior to the acceptance of
le� / Cep.
xo
Department Water -Wastewater Engineering
Contact: Roger Buffington, 970-221-6854, rbuffington((Dfcgov.com
2. The existing water service to the property is a'/ inch service. A detail has been provided which allows
splitting this service and installing separate meters for the two units.
3. If the property is being replatted into two lots, provide easements which allow the respective owners to
maintain their portions of the utility services.
rT�.Y.nawxeG/corn p.Qe-CQ-d
Department Stormwater Engineering
Contact: Glen Schlueter, 970-224-6065, gschlueter(&fcgov.com
1. It is important to document the existing impervious area since drainage requirements and fees are based
on new impervious area. An exhibit showing fhe existing and proposed impervious areas is required.
2. In the Old Town drainage basin, a drainage and erosion control report and construction plans are
required if there is an increase in impervious area greater than 5000 square feet These must be
prepared by a Professional Engineer registered in Colorado. If there is less than 5000 square feet of
new impervious area, a drainage letter should be sufficient to document the existing and proposed
drainage patterns.
3. Water quality treatment is provided for this site in the Udall Natural Area water treatment facility. However
onsite water quality treatment is encouraged as described in the Urban Storm Drainage Criteria Manual,
Volume 3 - Best Management Practices (BMPs).
(http:/ANww.udfod.org/downloads/down—chtmanual_vollll.htm)
4. It does not appear there will be an increase in impervious area greater than 5000 square feet. If there is,
onsite detention is required with a 2 year historic release rate for water quantity.
5. The design of this site must conform to the drainage basin design of the Old Town Master Drainage Plan
as well the City's Design Criteria and Construction standards.
6. The Stormwater development fee (PIF) is $6,313.00/acre ($0.1449/sq.ft.) for new impervious area over
350 sq.-ft., and there is a $1,045.00/acre ($0.024/sq.ft.) review fee. No fee is charged for existing
impervious area. These fees are to be paid at the time each building permit is issued. Information on
fees can be found on the City's web site at
http://www.fcgov.com/utilitestbusiness/buildersand-developers/plantAnvestment-development-fees or
by contacting Jean Pakech at 221- 6375. There is also an erosion control escrow required before the
Development Construction permit is issued. The amount of the escrow is determined by the design
engineer, and is based on the site disturbance area or erosion control measures shown on the site
construction plans.
Aclmwltd/
Depart ent: Park Planning
Contact: Craig Foreman, 970.221-6618, cforeman(@,fcgov.com
1. 1. 12/9/2011: No comments
Fort Collins
December 12, 2011
Rayno Seaser
Eggs -It Properties, LLC
719 Breakwater Drive
Fort Collins, CO 80525
Community Development and
Neighborhood services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970.224.6134 - fax
Icgov.00m
Re: 137 Mathews Duplex
Description of protect This is a request to replat the lot into two lots and to allow an addition of a permitted
use for 2 attached, single family dwelling units at 137 Mathews to a duplex. The site is zoned NCB,
Neighborhood Conservation Buffer.
Please see the following summary of comments regarding the project request referenced above. The
comments offered informally by staff during the Conceptual Review will assist you in preparing the detailed
components of the project application. Modifications and additions to these comments may be made at the
time of formal review of this project. If you have any questions regarding these comments or the next steps in
the review process, you may contact the individual commenter or direct your questions through the Project
Planner, Steve Olt, at 970-221-6341 or solt@fcgov.com.
Comment Summary:
Department: Zoning
Contact: Noah Beals, 970-416-2313, nbeals(a),fcaov.com
1. The replat would create two lots with the lot line running down the middle of the building.
Therefore this would need to be an addition of a permitted use to allow 2 attached single family dwelling
units on two lots.
2. This will also require a modification to the lot width to allow less then 40 ft, and less 5000 sq ft per lot
If the addition of the permitted use of attach single family is allowed no modification for zero side
setback.
3. The lot line should be adjusted to allow both single family units direct access to the front sidewalk from
*8
t air front door. Or perhaps a easement to be recorded allowing access.
Pr/j�! notvl�
"t p Department: Water -Wastewater Engineering
(J Contact: Roger Buffington, 970-221-6854, rbuffngton(cfcgov.com
1. Existing water mains and sanitary sewers in the area include a 4-inch water main in Mathews and an
8-inch sewer in the alley to the west.