Loading...
HomeMy WebLinkAboutLEGACY AUTO - PDP - PDP120001 - CORRESPONDENCE - (9)Department: Zoning Contact: Peter Barnes, 970.416.2355, pbarnes(cDfcgov.com Topic: Landscape Plans Comment Number: 7 Comment Originated: 01/24/2012 01/24/2012: Add a Planting Note stating that all landscaping and irrigation must be installed in each phase prior to the issuance of a certificate of occupancy for use of anybuilding or property within that phase or, if not installed, must be guaranteed with a financial guarantee in the amount of 125% of a written estimate from a landscape contractor of the value of labor and materials to complete the installation. Topic: Lighting Plan Comment Number: 3 Comment Originated: 01/24/2012 01/24/2012: New and existing lighting must comply with current code regulations. This means that lights must be down -directional and light sources shielded. No fixtures at an angle on angle brackets are allowed, and no adjustable angle brackets are allowed. Add note to plan that all new and existing fixtures will be down -directional and shielded. The lighting plan shows parking lot light poles and location. Please also show the locations on the site plan. Are any ground -mounted lights proposed? If so, show them on the lighting and site plans. Are the Aero-Dome light fixtures shown on the lighting plan 'shielded'? It's difficult to tell from the drawing if the light source is concealed. Topic: Site Plan Comment Number: 2 Comment Originated: 01/24/2012 01/24/2012: Provide a detail of the construction of the'decorative display spaces', i.e. materials, color, etc. Comment Number: 4 Comment Originated: 01/24/2012 01/24/2012: show/label/dimension existing canopy on plans. Indicate front setback of existing building and phase 2 addition. Indicate setback from Phase 4 building to north lot line. Comment Number: 5 Comment Originated: 01/24/2012 01/2412012: The 53 space storage parking area in Phase 1 is labed "stacked storage parking". What does "stacked" mean. Is the intent to stack items two high? If so, the 6' tall screen fence isn't tall enough. Or does 'stacked' really mean tandem parking (one space behind the other)? Comment Number: 6 Comment Originated: 01/24/2012 01/24/2012: The 8' wide customer parking stalls need to be 9' wide (Sec. 3.2.2(L) Table A). Department: Environmental Planning Contact: Lindsay Ex, 970-224.6143, lex(cDfcgov.com Topic: Lighting Plan Comment Number: 1 Comment Originated: 0112712012 01/27/2012: With respect to lighting, the City of Fort Collins Land Use Code, in Article 3.2.4(D) (6) requires that "natural areas and natural features shall be protected from light spillage from off -site sources." Thus, lighting from the parking areas or other site amenities shall not spill over to the buffer areas. The lighting plan must not allow for any foot candle spilllage into the buffer zone, in addition to addressing zoning's comments below. Department: Light And Power Contact: Doug Martine, 970.224-6152, dmartine@fcgov.com Topic: General Comment Number: 1 Comment Originated: 02/01/2012 02/01/2012: Electrica development and system modification charges will apply. Please coordinate power requirements with Light & Power Engineering at (970)221-6700. Comment Number: 2 Comment Originated: 02/01/2012 02/01/2012: Light & Power Engineering will need a paper copy (or pdf) of the final utility plan. A pdf can be sent to Doug Martine at DMARTINE@FCGOV.COM. Comment Number: 3 Comment Originated: 02/01/2012 02/01/2012: Please send an AutoCad drawing of the final site plan to Terry Cox at TCOX@FCGOV.COM. Department: Park Planning Contact: Craig Foreman, 970-221.6618, cforeman(a-fcgov.com Topic: General Comment Number: 1 01/23/2012: No comments Department: Zoning Contact: Peter Barnes, 970.416.2355, Pbarnes@fcgov.com Topic: General Comment Number: 8 Comment Originated: 01/23/2012 Comment Originated: 01/24/2012 01/24/2012: Note should be added to project data on cover sheet that a maximum of 36 display models will be displayed on designated display spaces and excess inventory will be stored on the designated screened storage spaces. Topic: Landscape Plans Comment Number: 1 Comment Originated: 01/24/2012 01/24/2012: The 15' landscape strip along College Avenue needs trees/shrubs per Sec. 3.2.1(E)(4). Phase lines on site and landscape plans are difficult to determine for Phases 1-3. The phases should be delineated in a clearer manor. Fort Collins Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins. CO 80522 970,221,6760 970.224 6134 - fax fcgov. com/devetopmentreview February 02, 2012 0 6. J� , �&,K 2Qoq # 0(� Don Shields 49 —t(,L• � WG Architects P.O. Box 270788 Fort Collins, CO 80527 lAfiu RE: Legacy Auto, PDP120001, Round Number 1lt���h Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Steve Olt, at 970-221-6341 or solt@fcgov.com. Comment Summary: Department: Environmental Planning Contact: Lindsay Ex, 970.224-6143, lex�fcgov.com Topic: Construction Drawings Comment Number: 3 Comment Originated: 01/2712012 01/2712012: The following notes/graphics will need to be added to the utility plan: 1. Please indicate the "limits of development" line, as per Section 3.4.1(14)(1) of the Land Use Code. 2. Please add the following note to the utility, site and landscape plans "See Section 3.4.1 of the Land Use Code for allowable uses within the buffer zone" 3. Please add an Environmental Planner signature to the signature blocks on the utility plans. Topic: Landscape Plans Comment Number: 2 Comment Originated: 01/27/2012 01/27/2012: Within the 50' buffer zone, according to Article 3.4.1(E)(1)(g), the City has the ability to determine if the existing landscaping within the buffer zone is incompatible with the purposes of the buffer zone. The landscaping in the buffer zone, as currently proposed, in insufficient to meet the standards of 3.4.1. For instance, the trees proposed within the buffer area (only three) are lacking both in quantity (we want more trees and shrubs throughout the entire site) and quality (the proposed trees are not native, please see the City's Native Plants Guide available at hftp://www.fcgov.com/naturalareas/native-plants.php for a more appropriate plant palette). Staff would be happy to meet with you to discuss these issues in more detail. Topic: Lighting Plan