HomeMy WebLinkAboutNEW PROSPECT - FDP - FDP120011 - CORRESPONDENCE - (3)VIGNEi TE s t i o s points so that adequate clearance and protection can be designed and added to the utility plans now. Potholing completed, storm sewer profiles updated. Comment Number: 2 Comment Originated: 08/14/2012 Provide a detail on the proposed MH to be constructed over the 30" sewer near Lots 9 & 10. Complete. Comment Number: 3 Comment Originated: 08/14/2012 Is there an irrigation tap planned for the open space area? N" Irrigation tap added to NW corner of central open -space Department: Zoning Contact: Peter Barnes, 970-416-2355, nbarnesQfc-gov.com Topic: Site Plan Comment Number: 1 Comment Originated: 07/27/2012 Site plan sheet 2 of 5 indicates that the front building setback for lots 18 - 22 will be 10'. The code requires a 15' miniumum front setback. The proposed 10' setback will require a modifica- tion. The 'Typical Lot' details on the same sheet show similar non -complying setbacks for other lots. See Current Planning comment #1. This issue has been resolved. Comment Number: 2 Comment Originated: 07/27/2012 Note #19 on site plan sheet 1 of 5 is confusing. It states that lots 1-25 can be duplexes or de- tached single family, but goes on to state that there can be only one unit per lot. I assume the term °unit" means dwelling unit, and if so, that means there can't be any duplexes on those lots since that would be 2 units on a lot. If by 'unit' they mean 'building', then that's the term they should use instead. If 'unit' means 'building', then Note #20 becomes confusing in that it would mean that 2 single-family dwellings could be on lot 26 and on lot 27. This note has been corrected to be less confusing. Thank you for your time spent in reviewing these plans. If you have any further questions, please feel fiw to contact any of the team members. Yours Truly, ASLA, LEED AP New Prospect Response to Comments 10.5.12 Page 11 VIGNETTE s t u d i o s Contact: Jeff County, 970-221-6588, jcounjUQfcgovcoM Topic: Site Plan Comment Number: 11 Comment Originated: 08/14/2012 There are line over text issues on sheet 2. Completed Comment Number: 12 Comment Originated: 08/14/2012 What are the "s" shown under the lot numbers? Please add a note in the legend for this. Completed Comment Number: 13 Comment Originated: 08/1412012 Please change Ellis Drive to Ellis Street. Completed Comment Number: 14 Comment Originated: 08/14/2012 The typical lot detail for Lots 1-2 & 18-25 is very busy & confusing. It would be easier to read if it were at a larger scale. Completed Comment Number: 15 Comment Originated: 08/1412012 Please correct the easement widths on sheet 2. These should match the subdivision plat. Completed Comment Number: 16 Comment Originated: 08/14/2012 Please change the 51' ROW to Varies, for Ellis Street & Apex Drive. Completed Department: Traffic Operation Contact: Ward Stanford, 970-221-6820, wstanford6fcgov.com Topic: General Comment Number: 1 Comment Originated: 08/17/2012 No Comments. Thanks! Department: Water -Wastewater Engineering Contact: Roger Buffington, 970-221-6854, rbuffington cgQv.com Topic: Construction Drawings Comment Number: 1 Comment Originated: 08/14/2012 The Spring Creek sanitary sewer trunk lines are critical lines in the City's collection system. At the points where the storm drains are crossing over the trunk lines, the clearances currently shown on the plans are not adequate. Pothole these trunk sewers at the storm drain crossing New Prospect Response to Comments 10.5.12 Page 10 VIGNETTE s t u d i o s Please remove the P.D.P. from the title, and P.U.D. from the statement of ownership and subdi- vision. Corrected. Comment Number: 3 Comment Originated: 08/14/2012 Please add a space between the comma after Collins and County. Complete. Comment Number: 4 Comment Originated: 08/14/2012 Is there right of way for Prospect Road being dedicated by this plat? ROW is existing. Comment Number: 5 Comment Originated: 08/14/2012 Why is a 9.5' utility easement needed in a tract that is being dedicated as a utility, drainage, grading & access easement? Corrected. Comment Number: 6 Comment Originated: 08/1412012 What is the heavy dashed line at the south end of Ellis Street for? If it is the division line for streets, please thin the line down & add arrows. See redlines. Corrected. Comment Number: 7 Comment Originated: 08/14/2012 Are Ellis Street & Sprocket Drive private streets? If they are private, do they need to be emer- gency access easements? Complete/ labeled. Comment Number: 8 Comment Originated: 08/14/2012 There are line over text issues. Corrected. Comment Number: 9 Comment Originated: 08/1412012 There are text over text issues. Corrected. Comment Number: 10 Comment Originated: 08/14/2012 Please mask the text in Tract F, if possible. Complete. Department: Technical Services New Prospect Response to Comments 10.5.12 Page 9 VIGNETTE s t u d i o s Complete. Comment Number: 23 Comment Originated: 08/14/2012 There are line over text issues on sheet 8, 11 & 16. Complete. Comment Number: 24 Comment Originated: 08/14/2012 Please mask the text in the profiles on sheet 11 & 12. Complete. Comment Number: 25 Comment Originated: 08/14/2012 Please mask all text in the hatched area on sheet 18. Complete. Topic: Landscape Plans Comment Number: 17 Comment Originated: 08/14/2012 Please change Ellis Drive to Ellis Street. Completed Comment Number: 18 Comment Originated: 08/14/2012 Please correct the easement widths on sheet 2. These should match the subdivision plat. Completed Comment Number: 19 Comment Originated: 08/14/2012 Please label Sprocket Drive on sheet 4. Completed Comment Number: 20 Comment Originated: 08/14/2012 There are line over text issues on sheet 4. Completed Comment Number: 21 Comment Originated: 08/14/2012 Please correct the sheet title on sheets 4 & 5. Completed Topic: Plat Comment Number: 1 Comment Originated: 08/14/2012 The legal description & boundary close. Comment Number: 2 Comment Originated: 08/14/2012 New Prospect Response to Comments 10.5.12 Page 8 VIGNETTE studios All items have been addressed. Aspen will work with Wes and Jesse to complete the Site Specific Report for Erosion and Maintenance of the site. Aspen understands mylars will not be signed until this is complete and approved by Jesse and Wes. Department: Stormwater Engineering Contact: Wes Lamarque, 970-416-2418, wlamaraue fcgov.com Topic: Floodplain Comment Number: 1 Comment Originated: 08/17/2012 1. Please make all the changes called out in the red -lined notes on the plat, the landscape plan (Sheets 4/5 of 5), the drainage basin exhibit (Sheet 7 of 18), the grading plan (Sheet 8 of 18), the floodplain plan (Sheet 18 Of 18), and the drainage report. 2. Please add a fencing detail of breakaway fencing, to the storm drainage detail sheet. A copy of the detail drawing will be sent to John Gooch, the developer's engineer. Fencing detail has been added to the Civil Plans. Topic: General Comment Number: 3 Comment Originated: 08/17/2012 The detention pond needs to meet the Detention Pond Landscape Standards as well as the landscape requirements of the Environmental Planner due to the pond's proximity to Spring Creek. This has been revised with additional plantings located in the pond. Comment Number: 4 Comment Originated: 08/17/2012 Please revise the storm sewer profiles as to what is public or private. See redlines. Corrected/Jabeled. Comment Number: 5 Comment Originated: 08/17/2012 Please add temporary erosion control over the rip -rap section for protection until vegetation is established. Corrected/labeled. Comment Number: 6 Comment Originated: 08/17/2012 Please revise the water quality outlet structure detail to show 1 column and revise correspond- ing hole diameter. The City recommends only 1 column per row so larger diameter holes can be used to minimize clogging. Correctedllabeled. Department: Technical Services Contact: Jeff County, 970-221-66889 jcounjXQfcgovcom Topic: Construction Drawings Comment Number. 22 Comment Originated: 08/14/2012 Please remove the bearings & distances from sheet 4 & 5. New Prospect Response to Comments 10.5.12 Page 7 VIGNEi TE s t i o s Please provide a copy of these redlines back to staff and indicate how this comment was ad- dressed. Number:78 Created:2119/2010 Unresolved [2/19/10] Add notes to Plat per redlines regarding conservation measures and buffer zones. Ron Department: Forestry Contact: Tim Buchanan, 970-221-6361, tbuchananoGgov.com Topic: Landscape Plans Comment Number: 1 Comment Originated: 08/14/2012 Contact the City Forester for a final review of existing trees in an on site meeting to confirm if any mitigation is required. This has been completed with the existing trees and notes shown on the plans, as well as the mitigation trees. Department: LightAnd Power Contact: Doug Martine, 970-224-6152, dmartine(&fcgov.com Topic: General Comment Number: 1 Comment Originated: 07/25/2012 07/25/2012: The developer will need to coordinate and pre -determine the electric meter loca- tions with Light & Power Engineering (970)221-6700. Noted Department: Park Planning Contact: Craig Foreman, 970-221-6618, cforemanDfcgov.com Topic: General Comment Number: 1 Comment Originated: 07/20/2012 07/20/2012: No comments Thanks! Department: Stormwater Engineering Contact: Wes Lamarque, 970-416-2418, wlamarnue cgov.com Topic: Erosion Control Comment Number: 2 Comment Originated: 08/17/2012 Please see the attached Erosion Control Checklist for the requirements needed on the Erosion Control Plan & Report. New Prospect Response to Comments 10.5.12 Page 6 VIGNEITTos s t i [2/19/10] Add note to Plat, Site, Landscape, Demolition, Grading and Erosion Control plans: "Refer to Section 3.4.1(E) of the Land Use Code for allowable uses within a buffer zone Comment Number: 12 Comment Originated: 08/15/2012 In order to ensure compliance with Section 3.4.1(0) of the Land Use Code, please provide a copy of the ACOE permit for the work adjacent to Spring Creek or written verification that a permit is not required. his will be provided prior to construction. Comment Number: 14 Comment Originated: 08/15/2012 A bond will be required for the plantings within the buffer zones on the project at the. time of CO and will be documented in the Development Agreement. I can provide you with examples of other bonds, if that is helpful. Noted Comment Number: 15 Comment Originated: 08/16/2012 A weed management plan will also be required with the involvement of a Certified Pesticide Ap- plicator, specifically in the Rangeland category. This will be coordinated Topic: Landscape Plans Comment Number: 9 Comment Originated: 08/15/2012 1 did not see "ALTE" in the landscape plan planting list. As this tract is within the Natural Habitat Buffer Zone, additional shrubs and trees shall be planted to comply with Section 3.4.1(E)(1)(g) of the Land Use Code. This has been added, and is Thinleaf Alder Number:76 Created:211912010 Unresolved [2/19/10] Add native landscape material in Tract F to integrate and blend the open space with the adjoining natural area. Additional Landscaping has been added. Comment Number: 13 Comment Originated: 08/15/2012 Is it possible to drill seed the dryland seed mix instead of hand seeding? This will increase the success of the plantings. I will also work with the staff in Natural Areas to see if a cover crop would be appropriate for this seed mix. Drill Seeding is appropriate for this area, but some hand seeding may also occur. Department: Environmental Planning Contact. Lindsay Ex, 970-224-6143, IexQfcgovcom Topic: Plat Comment Number: 10 Comment Originated: 08/1512012 New Prospect Response to Comments 10.5.12 Page 5 VIGNETTE s t u d i o s LIGATION OF OPERATION, MAINTENANCE OR RECONSTRUCTION OF SUCH PRIVATE STREETS AND/OR DRIVES NOR SHALL THE CITY HAVE ANY OBLIGATION TO ACCEPT SUCH STREETS AND/OR DRIVES AS PUBLIC STREETS OR DRIVES." This note has been added. Comment Number: 11 Comment Originated: 08/17/2012 The plat language has since been updated and will need to be modified to the updated version. An electronic version of this can be sent, or a hard copy provided. Corrected. Comment Number: 14 Comment Originated: 08/17/2012 Are there lots that are prohibited from having basements, and if so, can these lots be called out specifically on the plat as not being allowed to have basements? This would ensure that the in- formation is known at time of record searches with the plat being recorded at Larimer County. A note has been added to the Plat to reflect that basements can not be utilized when groundwa- ter is within 3' of the finish floor elevation of the basement, unless an engineered sub -drain, de- signed by a Professional Geotechnical Engineer, is provided. Department: Environmental Planning Contact: Lindsay Ex, 970-224-6143, lex fcgov.com Comment Number: 1 Comment Originated: 08/16/2012 Environmental Planning staff will be place a hold on the building permits for these lots to ensure that the design standards proposed are upheld. Noted Number:69 Created:2/1912010 Unresolved 12/19/10] For lots 23-25, address how Sections 3.4.1(1) & (L) of the Land use Code are being met. Of major importance will be how the three homes fit into the landscape. Design guidelines addressing bulk, massing and colors shall be developed. For the public hearing a draft of pro- posed guidelines shall be developed. Landscape improvements shall also be depicted within the design guidelines. Comment Number: 6 Comment Originated: 08/15/2012 Please show a detail for the fence. This has been shown Number:74 Created:2119/2010 Unresolved [2/19/10] Show a detail for the fence. Comment Number: 7 Comment Originated: 08/15/2012 Please remove the'(2)' from the plat on this note. Completed Number:76 Created:211912010 Unresolved New Prospect Response to Comments 10.5.12 Page 4 rTVIGNETTE s t u d i o s The site and construction plans need to specify signs being added to the entrances of the Sprocket Drive and Ellis Street loop indicating that each street is privately owned and main- tained. Please provide a detail of these signs on the construction plan set, examples of these are with the existing Council Tree Avenue in Front Range Village and the under construction Choice Center Drive in Choice Center. These signs have been added. Comment Number: 10 Comment Originated: 08/17/2012 Please verify whether driveover curb is intended to be used in public right-of-way. A driveover curb detail didn't appear to be provided in the details sheet. No drive -over curb will be used in the ROW. All curb for public streets is 30" vertical curb. Comment Number: 13 Comment Originated: 08/17/2012 What are the agreements that will be required for the work that occurs offsite of the property onto City owned land to the south? (Is it unusual for a private storm sewer line to be placed in City owned property?) The storm sewer is within an approved 20' drainage easement. Please refer to documentation in the City's file. Comment Number: 15 Comment Originated: 08/17/2012 The engineer will need to verify whether a 404 permit is needed from the Army Corps. This permit, if required, will be provided prior to construction and shall be noted in the DA. Topic: Plat Comment Number: 1 Comment Originated: 08/17/2012 Please remove "P.D.P." at the end of "New Prospect P.D.P." on the title of the plat. This has been removed. Comment Number: 6 Comment Originated: 08/17/2012 In addition to the previous comment, on the plat, there needs to be a Tract created to designate the Sprocket Drive and Ellis Street loop (with then dedication of permanent easements to the City for utility, drainage, access, and emergency access easement). Currently the plat appears to show these as public right-of-way, dedicated to the City, which would be problematic. This has been provided. Comment Number: 7 Comment Originated: 08/17/2012 Please add a Notice the City has created regarding the use of private drives on the plat. A paper copy will be provided for the proper illustration, the text of the note is as follows: "ALL RE- SPONSIBILITIES AND COSTS OF OPERATION, MAINTENANCE AND RECONSTRUCTION OF THE PRIVATE STREETS AND/OR DRIVES LOCATED ON THE PRIVATE PROPERTY THAT IS THE SUBJECT OF THIS PLAT SHALL BE BORNE BY THE OWNERS OF SAID PROPERTY, EITHER INDIVIDUALLY, OR COLLECTIVELY, THROUGH A PROPERTY OWN- ERS' ASSOCIATION, IF APPLICABLE. THE CITY OF FORT COLLINS SHALL HAVE NO OB- New Prospect Response to Comments 10.5.12 Page 3 VIGNETTE s t u d i o s Detail and note updated. Comment Number: 9 Comment Originated: 08/17/2012 More information is needed on the construction plan set for the two inlets proposed in proposed driveways. Please have details provided on the construction plan set showing cross sectional views for both the inlets and the driveways, how the inlet grate matches these driveway grades, etc. It may be worth looking into having the inlets be placed behind the gutter. Detail provided for clarification. Comment Number: 12 Comment Originated: 08/17/2012 Were additional variance requests intended to be submitted beyond those granted during the PDP? If so, I did not receive a copy with this submittal. All variances listed were approved with the PDP/ hearing for the project. Topic: General Comment Number: 2 Comment Originated: 08/17/2012 Can the possibility be explored of widening Ellis Street out to 36 feet in width approaching Pros- pect Road? The wider width would help create an approach onto Prospect Road that would bet- ter allow a three lane cross-section to function (with right -in, left -out, and right -out maneu- vers). The intent would be that the 36 feet would extend for a short distance past the intersec- tion such that vehicles at the intersection We've had the 30 feet local street cross section wid- ened out to 36 feet or larger at arterial intersections in development such as Pinnacle Town - homes (with Robertson Street at 39 feet), Lemay Avenue Estates, Sidehill and Observatory Vil- lage. It appears that since additional right-of-way occurs on the west side of Ellis Street, it may not be as impactive to accommodate this widening. This was explored, but required cutting beyond our project limits, as well as affecting landscap- ing and other offsite improvements being required to make this work. The Client declined to in- corporate this into the plan due to offsite improvements that would be required and the trickle down of changes that would be required. Comment Number: 4 Comment Originated: 08/17/2012 Please provide access ramps that allow for a crossing for the Ellis Street/Apex Drive street turn (no striped crosswalk), perhaps this could occur with the extension of the trail from Tract C out to this street turn (realizing that it appears an electric transformer may be planned for this area, which may be of concern). Ramps have been added and the transformer moved. Comment Number: 5 Comment Originated: 08/17/2012 Please label "(Private Drive)" on all sheets for the Sprocket Drive and Ellis Street loop south of Apex Drive. Complete Comment Number: 8 Comment Originated: 08/17/2012 New Prospect Response to Comments 10.5.12 Page 2 VIGNETTE s t u d i o s October 5, 2012 Ted Shepard City Planner Community Planning and Development 281 North College Avenue Fort Collins Colorado 80524 Dear Ted, The following is the applicant's response to the New Prospect staff comments. Please find at- tached copies of the revised FCP plans for your review. RE: New Prospect, FDP120011, Round Number 1 Department: Current Planning Contact: Ted Shepard, 970-221-6343, tshe and fcgov.com Topic: General Comment Number: 1 Comment Originated: 08/23/2012 A review of the P.D.P. and Staff Report reveals that Lot 25 is to be restricted to a one-story building and in another section of the Staff Report there is a reference that the western portion of the house will be restricted to being a one-story garage. The restriction on this lot should be stated clearly in note D under Design Guidelines. It was agreed to limit the western portion to a story and a half garage. Not D has been changed to reflect this. Comment Number: 2 Comment Originated: 08/23/2012 With regard to the comment from Zoning regarding the front setbacks, please note that I have discussed this with Peter Barnes and we agree that Section 3.5.2(D)(2)(a) supersedes the re- quirement for a 15 foot minimum front setback. This is because Lots 18 - 25 will be served by a private drive. In order to avoid confusion in the future, please clearly label, on both the site plan and plat, the segments of roadway that are private drives. This has been completed Department: Engineering Development Review Contact: Marc Vista, 970-221-6567, mvirata fcaov.com Topic: Construction Drawings Comment Number: 3 Comment Originated: 08117/20120 The drive approaches for the two private drives intersecting the south side of Ellis Street and Apex Drive appear to be built as a standard street intersection as. evident by the reference of LCUASS detail 708. These drive approaches need to be concrete to the property line and be built with the Standard Drive Approach (LCUASS Detail 707). Note #3 on Sheet C-010 does indicate the use of concrete to the right-of-way, but combining this with 708 instead of 707 seems confusing. New Prospect Response to Comments 10.5.12 Page 1