Department: Zoning Issue Contact: Jenny Nuckols
Topic: Zoning
Number: 6 Created: 1/26/2010
[1/26/10] Setbacks in the LMN zone require a 8' rear setback. Typical Lot Details are
showing a 6' rear setback on lots 1-2 and 18-25
This has been corrected.
Number: 7 Created: 1 /27/2010
[1/27/10] Am I correct in reading that the front of the homes on lots around the perimeter
face INTO the street and the homes in the center have garages facing the streets.
Therefore the interior lots face onto the courtyard, but the exterior lots look onto the rear
yards, garages of those homes across the street from them? Just concerned with the
'view" for those homes that look at garages and back yards from the front of their
homes.
This is a valid concern, and is one we have discussed and are addressing within the
design guidelines for the project.
Number: 8 Created: 1 /27/2010
[1/27/10] Street trees are required along both sides of both drives.
I have not been able to find this requirement in the land use code. Nor has this been
required of other projects with private drives. We do understand the concern, and have
provided some guidance to this on our lot typical s.
Thank you for your time spent in reviewing these plans. If you have any further
questions, please feel free to contact any of the team members.
Yours Truly,
PO Box 1889
Fort Collins, CO 80524 (970) 472-9125
www. v i pnpttestt ir♦ ios. com
VIGNETTE
s t u d i o s
Number: 23 Created: 2/9/2010
[2/9/10] Show the N/S water mains in the west edge of Pinnacle TH development.
Complete
Number. 24 Created: 2/9/2010
[2/91101 Check the locations shown for the water/sewer mains in Prospect.
Complete and corrected
Number: 25 Created: 2/9/2010
[219/10] Is the water valve shown in the center of the access off Prospect a curb stop?
If so, add note to abandon this service at the main.
The valve is a curb stop and has been noted as .such.
Number: 26 Created: 2/9/2010
[2/9/10] Will these houses have basements? If not, add the detail for the 3/4-inch meter
pit. Water meters are not allowed in crawl spaces.
Some of the houses will have basements. The detail has been added to sheet 12.
Number: 27 Created: 2/9/2010
[2/9/10] Revise the alignment of the sewer services for Lot 27 and the house east of Lot
26 to eliminate the clean -outs in the street.
Complete
Number: 28 Created: 2/9/2010
[2/9/10] Label locations of water main lwerings. Provide details with elevations of
water main and storm sewer.
Lowerings may be required, and details will he provided for each lowering in the final
design.
Number: 29 Created: 2/9/2010
[2/9/10] See redlined plans for other comments.
Complete
Number: 30 Created: 2/9/2010
[2/9110] Schedule a meeting to review these comments and discuss the location of
water/sewer services on the lots.
Complete
PO Box 1889
Fort Collins, CO 80524 (970) 472-9125
www. vianettasti ulins.rnm
VIGNETTE
s t u d i o s
Number: 52 Created: 2/10/2010
(2/10/10] Are the pipes and storm sewers sized for the 100-year storm? If not, a
conveyance needs to be designed for these flows to the detention pond including safely
conveying these flows and erosion protection.
Pipes will be sized for 100 year flow conveyance in the final design.
Number: 54 Created: 2/10/2010
[2/10/10] The swales may erode the landscaped surfaces. Some have supercritical
flow.
Swales and the permanent erosion control calculations will be provided in the final
design.
Department: Stonmwater-Water-Wastewater Issue Contact: Roger Buffington
Topic: Water -Wastewater
Number: 17 Created: 2/9/2010
[2/9/10] As noted in the conceptual review comments, provide minimum of 15 foot
easement on the south side of the 24-in sanitary trunk sewer.
Complete
Number: 18 Created: 2/9/2010
[2/9/10] Location of sewer south of Lots 8-10 too close to 30 inch truck line.
Line has been revised per meeting with Roger Buffington.
Number: 19 Created: 2/9/2010
[2/9/10] Add gate valves where shown on redlined plans.
Complete
Number: 20 Created: 2/9/2010
[2/9/10] Would moving the hydrant near Lot 27 to just NE of Lot 3 address PFA's
concern noted in comment No. 9?
Third hydrant added per PFA' comments.
Number: 21 Created: 2/9/2010
[2/9/10] Label length's of pipe between valves,fittings, etc.
This will be done at final design.
Number: 22 Created: 2/9/2010
[2/9/10] Label swivel tees, TB's and valves at the hydrant locations.
Complete
PO Box 1889
Fort Collins, CO 80524 (970) 472-9125
www. vi pnpttesti i(i ins. com
VIGNETTE
s t TIT!
i o s
Number: 43 Created: 2/10/2010
[2/10/101 The "P.U.D." needs to be taken out of the title & ownership statement
This has been corrected.
Number: 44 Created: 2/10/2010
[2/10/101 Is the "loop" (Ellis & Soule Drives) public or private? According to the site plan,
this is a 20' Private Drive/Emergency Access.
This is a private drive.
Number: 45 Created: 2/10/2010
[2/10/10] The "Sight Distance Easement Restrictions" statement is not needed, if no
sight distance easements are on the plat.
Topic: Site Plan
Number: 47 Created: 2/10/2010
[2/10/10] Please add the "less" to the legal description on the site plan.
Complete
Topic: Utility Plans
Number: 53 Created: 2/10/2010
(2/10/10] We were not routed an utility plan set. We will need to review them before they
go to mylar.
Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque
Topic: Floodp/ain
Number: 49 Created: 2/10/2010
[2/10/101 Please see redlined plans and 50% F000dplain Checklist for all floodplain
comments.
All redlines have been addressed per the checklist, with the exception of the typical
foundation plan, which will be shown in the final design.
Topic: Stonnwater
Number: 50 Created: 2/10/2010
[2/10/10] The quantity detention volume claculated in the drainage report is low
compared to talcs done in our office. The detention volume required should be around .
75 ac-ft, not .55 ac-ft.
We have revised the FAA calculations based on the new City spreadsheet.
Number: 51 Created: 2/10/2010
[2/10/10] The outfall needs to be determined before a hearing can be scheduled.
Outfall will be directly to Spring Creek
PO Box 1889
Fort Collins, CO 80524 (970) 472-9125
www. vi pnpttasti irl ins. com
VIGNETTE
s t u d i o s
volume, constrained arterial. Please provide further discussion and options for aligning
Ellis.
This has been addressed in the transportation memorandum dated February 24, 2010.
Number. 60 Created: 2/11/2010
[2/11/10] Following the previous discussion of difficulty in agreeing with the proposed
offset to Ellis, please provide discussion and options for reducing the negative aspects of
the proposed offset intersection.
This has been addressed in the transportation memorandum dated February 24, 2010.
Number: 61 Created: 2/11 /2010
[2/11/10)Disregard.
Department: Transportation Planning Issue Contact: Matt Wempe
Topic: Transportation
Number. 2 Created: 1/26/2010
[1/26/10] Per conversation with Terence Hoaglund, Transportation Planning (Matt
Wempe) has preliminarily approved the internal sidewalk network shown on Tract C.
This preliminary approval is contingent upon 1) homes facing the internal sidewalk
network (condition met), and 2) installation of pedestrian crossing markings along the
outer Soule Drive sidewalk in the southeast comer of the property (condition met). No
pedestrian crossing markings are required on the west side of Soule Drive due to
landscaping and drainage requirements.
Number: 3 Created: 1 /26/2010
[1/26/101 The plans seem to show a gap in the sidewalk along Apex Drive connecting to
the development to the east. Is this correct?
This has been corrected.
Number: 4 Created: 1 /26/2010
[1/26/10] All ADA ramps must be directional
These have been added
Number: 5 Created: 1 /26/2010
[1/26/101 What type of shade trees will be planted along the sidewalks? They should
not be low enough to block the sidewalks.
These will follow typical street tree requirements.
Department: Technical Services Issue Contact: Jeff County
Topic: Plat
Number: 42 Created: 2/10/2010
[2/10/10] The boundary & legal close.
PO Box 1889
Fort Collins, CO 80524 (970) 472-9125
www.vianattasti irlins.rnm
VIGNETTE
s t u d i o s
Number: 14 Created: 2/9/2010
PLAT
On the plat, please label the southernmost drive, which runs east -west. It currently is
Soule but is not labeled. Also, the roadway currently named Soule, for addressing
purposes, will be considered a north -south roadway.
Completed
Number: 15
HYDRANT CLEARANCE
Unless groundcover or equivalent heighttsize,
from a fire hydrant (full growth).
Noted
Created: 2/9/2010
landscaping must be at least 36 inches
Number: 16 Created: 2/9/2010
FIRE LANE/NO PARKING
Please be aware that PFA has similar developments in its district (Emergency Access
Easement/dedicated parking stalls) that have difficulty keeping residents and visitors
from parking along the no -parking areas. This causes access problems for emergency
vehicles. Please convey to the HOA that it has a responsibility for not only maintaining
the EAE, but also enforcing no parking.
A note to this affect has been added to the site plans.
Department: Traffic Operations Issue Contact: Ward Stanford
Topic: Traffic
Number: 58 Created: 2/11 /2010
[2/11/10] The counts in the TIS at Ellis may be low due to the time of year of the counts
and changes this Fall in Lesher's transportation plan providing parental drop-off/pick-up
on Ellis. The possible low count gives concern from the proposed offset of the south leg
of Ellis and the possible left turn conflicts an offset intersection can have. Reviewing the
increase in traffic volumes on Prospect in the morning shows Prospect traffic rising
significantly during the 7 AM hour. Recent Travel Time studies show traffic flow
impediments in the vecinity of Stover. Being a signalized ped crossing this indicates
crossing ped and/or vehicle activity near the school as early as 7:05 AM and as late as
7:50 AM. I believe it's beneficial to get a good picture of the current vehicular activity at
Ellis to help make an informed decision on the proposed Ellis offset. Please re-count
Ellis and Prospect between 7:15 AM and 7:45 AM.
This has been addressed in the transportation memorandum dated February 24, 2010.
Number: 59 Created: 2/11/2010
[2/11/10] The offset of the proposed south segment of Ellis with the existing north
segment is of concern. Offset intersections are problematic due to possible left turn
conflicts. Closely spaced ped crossings are not expected by motorists: Stover Street just
west of Lesher is an offset intersection and has been a source of traffic and pedestrian
problems for many years. To accept another offset intersection on the school's east side
is difficult to reconcile. The Variance process in the LCUASS has a Justification section
(1.9.4.d) that does not seem to be met by this proposed offset intersection on a high
PO Box 1889
Fort Collins, CO 80524 (970) 472-9125
www-vi a nP.ttP.Sh f d ins. cnm
VIGNETTE
s t u d i o s
located more than 150 feet from fire apparatus access as measured by an approved
route around the exterior of the building or facility. This fire lane shall be visible by
painting and signage, and maintained unobstructed at all times. Afire lane plan shall be
submitted for approval prior to installation. In addition to the design criteria already
contained in relevant standards and policies, any new fine lane must meet the following
general requirements:
(R Be designed as a flat, hard, all-weather driving surface (asphalt or concrete)
capable of supporting fire apparatus weights. Compacted road base shall be used only
for temporary fire lanes or at construction sites.
(0 Have appropriate maintenance agreements that are legally binding and
enforceable.
® Be designated on the plat as an Emergency Access Easement.
® Maintain the required minimum width of 20 feet throughout the length of the fire
lane (30 feet on at least one long side of the building when the structures is three or
more stories in height).
If the building is equipped throughout with an approved automatic fire -sprinkler system,
the fire code official is authorized to increase the dimension of 150 feet.
2006 International Fire Code 503.1.1, 503.2.3, 503.3, 503.4 and Appendix D
The emergency access easement has been shown on the plat.
Number. 11 Created: 2/9/2010
STREET NAME
After thinking about this for some time, PFA cannot approve the proposed name Soule,
based on the Larimer County 'Rules of the Street." This document states that new street
names: be simple to pronounce, in the opinion of the review jurisdiction; road names
should be unique and not be repeated in the county, with the exception of continuation of
existing streets; and all names shall be of the commonly acceptable spelling, according
to a standard dictionary. PFA already has an existing Sol Court and there is the potential
people would pronounce this new street as "soul' or "sol" instead of SOO-lee. Please
suggest a new, proposed name.
The street name has been changed to Sprocket Drive.
Number: 12 Created: 2/9/2010
GENERAL NOTE 8: Please write: Curbs on fire lanes will be painted red, and/or posted
"No parking, fire lane" except at designated parking stalls.
Since we don't really have any curbs, signs will be posted.
Number: 13 Created: 2/9/2010
GENERAL NOTE 9: Please write: Address numerals shall be visible from private drive
and/or alley at rear of SFA/MF dwelling units.
Completed
PO Box 1889
Fort Collins, CO 80524 (970) 472-9125
www.viunettP,;h idins_cnm
VIGNETTE
s t u d i o s
Department: Forestry Issue Contact: Tim Buchanan
Topic: General
Number: 57 Created: 2/10/2010
[2/10/10] Applicant needs to schedule an on- site meeting with the City Forester to
determine the condition of existing trees and suitability for retention.
Trees (including street trees) need to be direct labeled on the plan as to type.
We have met on site with the City Forester(s) to evaluate the existing trees. It was
determined that no mitigation will be required. Tree types will be labeled at final as is
common practice.
Department: Light & Power Issue Contact: Doug Martine
Topic: Electric
Number. 1 Created: 1 /25/2010
[1/25/10] No comments from Light & Power.
Department: PFA Issue Contact: Carie Dann
Topic: Fire
Number: 9 Created: 2/9/2010
WATER SUPPLY
One more hydrant needs to be added, for a total of three. Remove the hydrant shown
near Lot 10; add a hydrant near Lots 6 and 14; keep the hydrant near Lot 27. While the
utility plan submitted meets the requirements for hydrant spacing, what would happen if
we use the hydrant near Lot 27, is that the supply hose would stretch across Apex Drive,
cutting off all access for later -arriving apparatus. Here's our general water supply
requirements:
Fire hydrants, where required, must be the type approved by the water district having
jurisdiction and the Fire Department. Hydrant spacing and water flow must meet
minimum requirements based on type of occupancy. Minimum flow and spacing
requirements include:
• Commercial, 1,500 gpm at 20 psi residual pressure, spaced not further than 300
feet to the building, on 600-foot centers thereafter
• Residential within Urban Growth Area, 1,000 gpm at 20 psi residual pressure,
spaced not further than 400 feet to the building, on 800-foot centers thereafter
• Residential outside Urban Growth Area, 500 gpm at 20 psi residual pressure,
spaced not further than 400 feet to the building, on 800-foot centers thereafter.
These requirements may be modified if buildings are equipped with automatic fire
sprinkler systems.
2006 International Fire Code 508.1 and Appendix B
Noted
Number: 10 Created: 2/9/2010
EMERGENCY VEHICLE ACCESS
Please show the Emergency Access Easement (private drives Ellis and what's now
shown as Soule) on the plat. Access requirements are:
Fire access roads (fire lanes) shall be provided for every facility, building or portion of a
building hereafter constructed or moved into or within the PFA's jurisdiction when any
portion of the facility or any portion of an exterior wall of the first story of the building is
PO Box 1889
Fort Collins, CO 80524 (970) 472-9125
www.vipnpttp,;tiirlin-.com
VIGNETTE
s t u d i o s
Number: 37 Created: 2/9/2010
[219/10] Checklist E4 indicated that sight distance triangles and easements would be
shown at final. However, these are required prior to hearing - are there any sight
distance easements that need to be dedicated?
Sight Easements are now shown and letters of intent have been provided.
Number: 39 Created: 2/9/2010
[219/10] Please provide a detail in accordance with Figure 7-24 that calls out all
dimensions as shown so that we can determine if the street widening is to standard and
that the correct row has been dedicated.
Complete
Number: 41 Created: 2/10/2010
[2/10/10] Lot 18 and 811 E Prospect are showing the driveway placed over the storm
inlet. Please provide a detail with the intended inlet so I can see how this will work.
Thanks :)
The driveways will have concrete cross pans with concave gutter inlets installed. The
concave inlets will provide contouring that matches the cross -pan. Because of the steep
grade from Prospect to the connection to existing Apex Drive, the inlet locations are the
most feasible without requesting more variances to code.
Number: 65 Created: 2/17/2010
[2/17/10] Please show offsite grades for a minimum of 50'.
Existing topography has been shown to the limits that are feasible to provide tie-in to
existing roadways, the out/all in Spring Greek, and the adfaceni properties. Grading
limits match into existing in all areas of the lopo.
Number: 66 Created: 2/17/2010
[2/17/10] Please label all onsite details as "on site".
All details used are either standard City of Fort Collins details, or if nol standard details
are called out as -modified ". Some details are Apex details.
Number: 67 Created: 2/17/2010
[2/17/10] A culvert and flared end section is shown off site at the southeast property line.
Are there existing easements in place to allow for this construction or will you need to
obtain those?
The proposed storm outfall will now discharge directly to Spring Creek, with a 20'
drainage easement being required and shown in the plans.
PO Box 1889
Fort Collins, CO 80524 (970) 472-9125
www.vipnptteetti(lins.com
VIGNETTE
s t u d i o s
the Planning Department to see how they want to handle the site and landscape plan
changes later as I'm not sure if there's an additional process involved with that.
We have removed sidewalk connections to private lots from the plan sets. As an editors
note, I really don t see why it would matter where they get built. This has not been an
issue on past projects
Topic: Landscape Plans
Number: 46 Created: 2/10/2010
[2/10/10] Lot 26 has a street tree placed right at the edge of the driveway and may
cause a problem for the future homeowner. Other trees along the west side of the
private drive need to be placed further west to allow people to open their car doors.
This has been corrected
Topic: Plat
Number. 63 Created: 2/17/2010
[2/17/10] Please provide a tract table and remove the sight distance language if no SDE
is proposed.
This has been completed.
Topic: Utility Plans
Number: 31 Created: 2/9/2010
[2/9/10] Please label the public street typical street section and the private street typical
street for Ellis Drive with stations and curb type to make sure there are no confusions
later. Thanks John.
Complete
Number: 32 Created: 2/9/2010
[2/9/10] Please remove the word "Preliminary" from the cover page title.
Complete
Number: 34 Created: 2/9/2010
[2/9/10] Please remove "Proposed flow" labeling from the private drive on the plan
sheets.
Complete
Number. 36 Created: 2/9/2010
[2/9/10] Please list out all variances to street design standards under line 48 of the
general notes.
Complete
PO Box 1889
Fort Collins, CO 80524 (970) 472-9125
www_ vi anettash id ins. rnm
rVIGNETTE
s t u d i o s
This has been corrected
Number: 40 Created: 2/10/2010
[2/10/10] Please show the Limits of Development, all plan sets.
This has been added.
Number: 48 Created: 2/10/2010
[2/10/10] Please show all driveway locations in addition to the utilites for the homes
located off the private drive so that we can determine how and if everything will fit.
Several of the lots are less than 50' and if trees are required by Zoning, then there may
be an issue.
As agreed, we are showing a typical of how both a rear load, and a front load lot will
work with driveways and services.
All driveway locations will need to be dimensioned off the property line so that in the
future, they are constructed in the exact location approved.
Rather than determine exactly where driveways will be, we would prefer to create a
window upon which the driveways can be built, yet still work with services. This allows
flexibility with exact garage placement, door width, etc. As mentioned above, we have
shown a typical. At final, all driveway "windows" will be shown.
Number: 55 Created: 2/10/2010
[2/10/101 Please remove the utility easements shown in the public row at the
intersection of Prospect and Ellis as we do not grant easements on City property or row
(strange, I know, but it's a "legal" thing).
Complete
Number: 56 Created: 2/10/2010
[2/10/10] No structures of any kind are allowed in utility easements including overhangs,
footings, fireplaces, etc. Lots 2 and 17 are showing the utility easement placed over the
lot lines (which is fine) but need to place a note on the plan sets indicating this restriction
so that future homeowners and builders have no misunderstanding.
This note has been added
Number: 62 Created: 2/17/2010
[2/17/101 The private drive needs to be called out as a tract on the plat, etc.
This has been corrected
Number: 64 Created: 2/17/2010
[2/17/101 All sidewalk connections to private homes must be shown where they are to
be built or remove them entirely and handle them as an as -built later. Please check with
PO Box 1889
Fort Collins, CO 80524 (970) 472-9125
www.vianettesh id ins.rom
VIGNETTE
s t u d i o s
Number: 74 Created: 2/19/2010
[2/19/10] Show a detail for the fence.
This has been added.
Number: 76 Created: 2/19/2010
[2/19/10] Add note to Plat, Site, Landscape, Demolition, Grading and Erosion Control
plans: "Refer to Section 3.4.1(E) of the Land Use Code for allowable uses within a buffer
zone."
This has been added.
Number: 77 Created: 2/19/2010
[2/19/101 You will need to work with Natural Resources and Parks staff to allow the trail
to cross the natural area and be into the existing trail.
We are working with them on this issue.
Topic: Landscape Plans
Number: 75 Created: 2/19/2010
[2/19/101 Add native landscape material in Tract F to integrate and blend the open
space with the adjoining natural area.
We have added some trees, which will meet natural area requirements. At this point we
are not proposing shrubs due to concerns_ from the flood plain administrator.
Topic: Plat
Number: 78 Created: 2/19/2010
[2/19/10] Add notes to Plat per redlines regarding conservation measures and buffer
zones.
This has been completed
Topic: Utility Plans
Number: 68 Created: 2/19/2010
[2/19/10] Add the Environmental Planner signature line to Sheets 3-6 on the Utility Plans
set.
This has been added.
Department: Engineering Issue Contact: Susan Joy
Topic: General
Number: 38 Created: 2/9/2010
[2/9/10] Proposed sidewalks along Ellis must connect into the existing sidewalks. In
other words, no gap can be left between the two systems. It also appears that the
existing Apex Drive was not constructed to the property line and this development is
responsible for tying into the existing improvements. Please show the approximate
removals and street cuts required to tie the two sections of street together.
PO Box 1889
Fort Collins, CO 80524 (970) 472-9125
www. vi onettasti id i nc. rom
VIGNETTE
s t u d l o s
March 17th, 2010
Ted Shepard
City Planner
Community Planning and Development
281 North College Avenue
Fort Collins Colorado 80524
Dear Ted,
The following is the applicant's response to the New Prospect staff comments dated
February 16th, 2010. Please find attached copies of the revised PDP plans for your
review.
Department: Current Planning Issue Contact: Dana Leavitt
Topic: Environmental Planning
Number: 69 Created: 2/19/2010
[2/19/10) For lots 23-25, address how Sections 3.4.1(1) & (L) of the Land use Code are
being met. Of major importance will be how the three homes fit into the landscape.
Design guidelines addressing bulk, massing and colors shall be developed. For the
public hearing a draft of proposed guidelines shall be developed. Landscape
improvements shall also be depicted within the design guidelines.
These have been included in our submittal package
Number: 70 Created: 2/19/2010
[2/19/10] On all plans show the trail connection to the existing trail.
This has been done.
Number: 71 Created: 2/19/2010
[2/19/10] Add the Limits -of —Disturbance (LOD) line to all plans based upon the final
location per the Site Plan.
This has been done
Number: 72 Created: 2/19/2010
[2/19/10] On all plans the buffer zone is to be labeled as" Natural Feature Buffer Zone."
Add label for the buffer line also.
This has been done.
Number: 73 Created: 2/19/2010
[2/19/10] Natural Resources Department staff are calling for a 3-rail, open fence with
wire mesh along the south property line that abuts the City's natural area.
This has been shoivn on the site and landscape plans.
PO Box 1889
Fort Collins, CO 80524 (970) 472-9125
www. v ivnattesti id ins. cnm