HomeMy WebLinkAboutBROOKDALE SENIOR LIVING - MJA - MJA120003 - CORRESPONDENCE - (5)I Department: Zoning Contact: Noah Beals, 970.416.2313, nbeals(a)fcgov.com Topic: General Comment Number: 1 Comment Originated: 06/22/2012 06/22/2012: Sheet A302 Key Notes 11 states the cupola will be relocated. Plans should indicate the new location. Comment Number: 2 Comment Originated: 06/2212012 O6/22/2012: Land Use Code (LUC) 3.2.4 This section requires a Site Lighting Plan (see section for requirements). If there was one zoning did not receive a copy. Comment Number: 3 Comment Originated: 06/22/2012 06/22/2012: Plans (elevations, site plan, and landscaping plans) do not indicate any locations of new mechanical/utility equipment (vents, flues, conduits, meters and units). These need to be indicated with a note on how such equipment will be screened/painted. Comment Number: 4 Comment Originated: 06122/2012 O6/22/2012: LUC 3.2.5 Trash/Recycling enclosures shall be constructed on a concrete cement pad and designed with a walk-in access without having to open the main service gate and be at least twenty ft from a public sidewalk. Currently it appears there is no walk-in access.�e-E-'� Elevation drawings are required for the trash/recycling hrelosum Comment Number: 5 Comment Originated: 06/22/201122 At ex 06/22/2012: There is an existing sidewal ccoonnection along the middle driveway this connect should be completed and conne ted t st of of C internal sidewalks. c��xQ j"�- I Department: Technical Services Contact: Jeff County, 970.221.6588, icountv&fcgov.com Topic: Plat Comment Number: 1 Comment Originated: 06/22/2012 06/22/2012: There was no Subdivision Plat in this review. We will need to see it next review. Topic: Site Plan Comment Number: 2 Comment Originated: 06/22/2012 06/22/2012: Please add a legal description of the property to sheet TS. Comment Number: 3 Comment Originated: 06/22/2012 06/22/2012: There are line over text issues on sheets C100 & C110. Department: Water -Wastewater Engineering Contact: Roger Buffington, 070.221.6854, rbuffington(o fcgov.com Topic: Construction Drawings Comment Number: 1 Comment Originated: 06/22/2012 06/22/2012: Show existing City water and sewer mains. Comment Number: 2 Comment Originated: 06/22/2012 O6/22/2012: Show the water, sewer and fire service(sr o' he�g buildings. Comment Number: 3 Comment Originated: 06/22/2012 O6/22/2012: Schedule a meeting with Pou F� , u ority and Water Utilities to discuss location of the proposed fire hydrgnt-Wautihtiesuld prefer to have the hydrant located closer to Rule Drive Comment Number: 4 ) Comment Originated: 06/22/2012 06/22/2012: Move the portion�Ne\,)pestic water service near Rule Drive to the east and locate the curb stop and meter pit in the landscaped area similar to what's shown on the redlined utility plans (but not in the detention pond). Curb stop must be within a utility easement Comment Number: 5 Comment Originated: 06/22/2012 06/22/2012: Fire hydrant must be within a utility easement. Comment Number: 6 Comment Originated: 06/22/2012 O6/22/2012: Survey existing sewer main and provide design elevations for the sewer service. Topic: Plat Comment Number: 7 Comment Originated: 06/22/2012 O6/22/2012: Provide a copy of the plat with the next submittal. Department: Zoning Contact: Noah Beals, 970.416.2313, nbeals(@fcgov.com Topic: General Department: PFA Contact: Ron Gonzales, 970.416.2864, rgonzales(cDaoudre-fire.org Topic: General Comment Number: 1. Comment Originated: 06/26/2012 O6/26/2012: These two buildings are out of access from the fire lanes; therefore fire sprinklers are required. Knox Key Box(es) are to be provided for emergency ingress. Comment Number: 2. Comment Originated: 06/26/2012 06/26/2012: The proposed new fire hydrant is out of access from the parking lot fire lane; therefore, it shall be located south of the proposed location and made accessible from the parking lot fire lane. Comment Number: 3. Comment Originated: 06/26/2012 06/26/2012: There shall be provided an emergency access sidewalk, 5 ft wide, for the safe egress of those seeking the publlic way. It shall be signed and shall not be obstructed at any time, including snow. Department: Stormwater Engineering Contact: Wes Lamarque, 970.416-2418, wlamargue(a.fcgov.com Topic: General Comment Number: 1 ` 06/2712012: Stormwater is ready for a hearing. wdcft oil Department: Technical Services Contact: Jeff County, 970.221.6588, icourffv lIc-g om Topic: Building Elevations Comment Number: 5 06122/2012: No comments. Topic: Construction Drawings Comment Number: 6 Comment Originated: 06/27/2012 . Comment Originated: 06/22/2012 Comment Originated: 06/22/2012 06/22/2012: Benchmark 6-94 has been destroyed. Benchmark 7-94 is to the north at Harmony Road & Lemay Avenue. Comment Number: 7 Comment Originated: 06/22/2012 06/22/2012: Please change the benchmarks on sheet C2 to match the cover sheet & the project site. Comment Number: 8 Comment Originated: 06/22/2012 06/22/2012: There are line over text & text over text issues on sheets C3, C4 & C5. Topic: Landscape Plans Comment Number: 4 Comment Originated: 06/22/2012 06/22/2012: There are line over text issues on sheets L-1 & L-2. Topic: Plat Department: Forestry C Contact: Tim Buchanan, 970.221.6361, tbuchanan(cDfcgov.com Topic: Landscape Plans Comment Number: 2 Comment Originated: 06/27/2012 06/27/2012: Species Selection: 1. Green ash is used as a street tree. One green ash is proposed as the north most street tree. Green Ash is not on the City Street Tree List. Select a species from the City Street Tree list to replace it. 2. Provide quantities and method of transplant (B&B) for each of the proposed landscape trees. Also provide this for the shrubs using 5 gallon as the minimum shrub size. 3. Autumn Blaze Maple does not survive in the soils found in Fort Collins. The City Forester recommends that an alternate species be selected. Department: Light And Power Contact: Doug Martine, 970.224.6152, dmartineOfcgov.com Topic: General Comment Number: 1�� Comment Originated: 06/13/2012 O6/13/2012: Light &Power Engineering (221-670/0 ill�ee���d� a E mmercial Service Information (C-1) form completed for each new or modified( lecfh �seNice. Depending on the total of the new loads, the existing transformer on thee Ca (`side/e of h existing Sterling House MAY also be capable of serving the new buildings. ltyitay be -necessary for Light & Power to install another transformer for the n I ui>t d gat a�i . ation to be coordinated. Comment Number: 2 � Comment Originated: 06/13/2012 O6/13/2012: Electric development rrvd ssyystem modification charges will apply. Comment Number: 06/13/2012: Comment Number: Department: Outside Agencies Contact: Don Kapperman, , Topic: General Comment Originated: 06/13/2012 Comment Originated: 06/13/2012 Comment Number: 1 Comment Originated: 06/27/2012 O6/27/2012: Comcast comments that there needs to be a 2" conduit return from data room to phone room to new building/data room. This must be painted to match. Department: PFA Contact: Ron Gonzales, 970.416.2864, rgonzales(&poudre-fire.org Topic: General a Department: Forestry Contact: Tim Buchanan, 970.221-6361, tbuchanan(a)fcgov.com Topic: Landscape Plans Comment Number: 1 Comment Originated: 06/27/2012 06/27/2012: Trees to Transplant: 1. Some of the trees are near the upper threshold size to transplant successfully. The risk of survival increases with increased size. Consult with a tree -transplanting contractor in an onsite inspection of the trees to verify feasibility of transplanting the 14 trees that are shown on the plans to be moved. Provide the contractor's evaluation and recommendation for tree spade size to be used for each of the trees to be transplanted. Incorporate the contractor sizelEcommendations in to the tree mitiaatbaaote tahla 2. Provide a tree planting detail for the transplanted trees. Typically a water basin is constructed around large trees to facilitate irrigation. Consider adding this in this in the detail. The area over the ball should be mulched. 3. Provide an irrigation schedule (frequency) for th t ns lanted trees for the first growing season or two as recommended by the transplant ctr Iso include this schedule for winter irrigation. Indicate the recommended gallons o at r pera*t`r%e to be applied during each irrigation. 4. Tree number 15a is a flo "'ng crab pp nd appears too broad to move. Tree #14 is the same species and smaller, butt's shown to be removed. Consider transplanting #14 in place of #15a. 5. Tree #28 is a honeylocust to transplant. It is on a slope that will provide some difficulty in transplanting. Tree 26a is a 10-inch caliper Bur oak in good condition. It also is on somewhat of a slope. The bur oak may be a better candidate tree to transplant. 6. Add these notes: Trees proposed to be transplanted shall be moved with a tree spade of a 100 inch minimum size or with a larger size tree spade up to 120 inch minimum size where recommended by a qualified transplanting contractor. An ISA Certified Arborist shall inspect all transplanted trees at a regular interval over the first two years. Recommendations on care shall be provided to the owner. Department: Engineering Development Review Contact: Andrew Gingerich, 970.221.6603, agingerich(ftgov.com Topic: Plat Comment Number: 1 Comment Originated: 06/26/2012 06/26/2012: It appears that the plat cover does not contain the most recent dedication, maintenance, etc. language. This language has been provided to JR Engineering on 6/2612012. Comment Number: 2 Comment Originated: 06/26/2012 06/26/2012: Provide easement vacation note from the Development Review Guidelines 3(h) that pertains to vacating existing easements per this plat unless otherwise noted. Comment Number: 4 Comment Originated: 06/26/2012 06/26/2012: All easements, proposed or existing, shown on the plat must have bearing, distance, curve, etc. Comment Number: 8 Comment Originated: 06/26/2012 06/26/2012: The existing drainage easement (Rec. No. 98104028) appears to be aligned for drainage patterns from the existing site plan. Is it still needed in this specific layout based on the new site plan? Specifically the north end that is very near the building wall. Additionally the Proposed detention pond easement on the northeast corner appears to conflict with a building corner. Department: Environmental Planning Contact: Lindsay Ex, 970.224.6143, lex(a.fcgov.com Topic: Landscape Plans L/ Comment Number: 1 Comment Originated: 06/26/2012 06/26/2012: Please provide iled spe 'ifications of the grass mixes proposed on site at the time of final plans. Department: Forestry Contact: Tim Buchanan, 970.221-6361, tbuchananofcgov.com Topic: Landscape Plans Department: Engineering Development Review Contact: Andrew Gingerich, 970-221-6603, ayingerich@fcaov.com Topic: Construction Drawings Comment Number: 9 Comment Originated: 06/26/2012 06126/2012: Please revise callouts in notes in the plan sheets that reference projects other than Brookdale Senior Living Community. Comment Number: 10 Comment Originated: 06/26/2012 O6/26/2012: Please revise and correct numerous line over text issues, cutoff text and existing linework on top of proposed linework. Comment Number: 12 Comment Originated: 06/26/2012 O6/26/2012: Sheet C4 - Provide the street cut limits note on this sheet for the proposed 0 services. Comment Number: 13 Comment Originated: 06/26/2012 06/26/2012: Sheet C4 - Show and label existing water, sewer and fire services on the overall 0 utility plan. Comment Number: 14 Comment Originated: 06/26/2012 O6/26/2012: Sheet C4 - Have exisitng utilities and specifically dry utilities been located along Rule Drive. The storm sewer that is proposed along Rue Drive is shown to exist within the 9' d Utility Easement. Additional utility easements may y'eed�o bye dedicated to accomodate future utilities or the proposed storm sewer may need to be�cated f' rt�her to the north to accomodate existing utilities. Comment Number: 15 Comment Originated: 06/26/2012 O6/26/2012: Sheet C4 - An easement wil4eed to Pie -provided for the waterline to the hydrant in the middle of the site. Please f Gi;ali�-th ,eas�5iient on the plat and show on the Overall Utility Plan. Comment Number: 16 Comment Originated: 06/26/2012 )) O6/26/2012: Sheet C5 - Please clari the pedestrian bridge note to add that the bridge is to be constructed with this project but that the design might be "by others". Topic: General Comment Number: 3 Comment Originated: 06/26/2012 O6/26/2012: Development agreements currently exist for both Sterling House P.U.D. and Wovenhearts. It is recommended that a new development agreement be drafted to update and clean up the existing development agreements into one document. Comment Number: 7 I elms _ Comment Originated: 06/26/2012 06/26/2012: The access ramp at the intersection of Lemay Ave and Rule Drive needs to be try ADA compliant. If it is not currently constructed to current ADA requirements than it will need to be reconstructed. "\ ment Number: 11 Comment Originated: 06/26/2012 016/26/2012: What is the purpose of the Broadband easement & right of entry that exists on Lot 1. How is this being addressed and is their any conflicts with the building addition and the Broadband easement? Comment Number: 17 ` - .Is, 0— )Comment Originated: 06/26/2012 06/26/2012: 'V„�� /�, ( Pv'� 1c,� ;-1 C Department: Current Planning Contact: Courtney Levingston, 970-416.2283, clevingston(Mcgov.com Topic: General Comment Number: 6 Comment Originated: 06/27/2012 06/26/2012: The memory care building has an existing iron fence. Please show on site plan. Will the new facility is proposed to have any sort of fencing? If so, please provide dence detail. Comment Number: 7 Comment Originated: 06/27/2012 06/27/2012: Please take off trees from the site plan. Proposed and existing trees should be on the landscape and tree mitigation plan. Comment Number: 8 Comment Originated: 06/27/2012 06/27/2012: Please provide a landscaping table that shows the number of each proposed tree and the percentage that species comprises of the total per LUC 3.2.1(D)(3) Comment Number: 7 Comment Originated: 06/27/2012 06/27/2012: 1 have a conern about windows on the new north elevation and privacy. The adjacent property to the north has a parking lot where the head in parking (and headlights) will be directly pointed towards the development. Previously this may not have been an issue because of the space. With the addition there needs to be additional landscaping. Comment Number: 8 Comment Originated: 06/27/2012 06/27/2012: irrigation plans are required. Comment Number: 9 Comment Originated: 06/27/2012 The City's Plant List can be found online at: htt hwww:(cgou:com/forestry/plant_list.pdf Additionally, please take a look found at: htti)://www.ext.coloste Recommendation List. This can be pdf Comment Number: 10 /� Comment Originated: 06/27/2012 O6/27/2012: Please submit a lighti plan. The photometric plan must be calibrated such that the light loss factor is 1.00. All fixtures must have specifications and be fully sheilded and down directional. Comment Number: 11 Comment Originated: 06/27/2012 06/27/2012: The July 19th Planning and Zoning Board hearing may not be feasible at this point. The work session for the July hearing is July 13. The next hearing would be Thursday, August 16, at 6:00 p.m. in Council Chambers, 300 LaPorte Ave. Work Session for that hearing would be August 10th. You do not need to attend the work session. Department: Engineering Development Review Contact: Andrew Gingerich, 970-221-6603, agingerich(Mcgov.com Topic: Construction Drawings Comment Number: 5 Comment Originated: 06/26/2012 06/26/2012: Provide demolition plan with the Civil Construction Plans. Comment Number: 6 Comment Originated: 06/26/2012 06/26/2012: Existing linework appears to be missing from numerous sheets (i.e. site plan) and included and in conflict with proposed linework on many other construction drawing sheets. City of Fort Collins June 27, 2012 Edward Johnson PDC Midwest, Inc. 1130 James Drive Suite 106 Heartland, WI 53029 Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6760 970.224.6134 - fax fcgov.com/deve/0pmentreview RE: Sterling House PUD Replat - Brookdale Senior Living Major Amendment (1008 Rule Dr), ease 0see3theoyo ng summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Courtney Levingston, at 970416-2283 or clevingston@fcgov.com. Comment Summary: Department: Current Planning Contact: Courtney Levingston, 970.416.2283, clevincis .cc m Topic: General \� Comment Number: 1 Comment Originated: 06/26/2012 06/26/2012: Please show additio bco t to the north and west. Specifically the parking spaces for the adjacent properties. Comment Number: 2 Comment Originated: 06/26/2012 06/26/2012: 1 noticed many exisiting benches on site. What benches are exisitng, what benches are to remain? Are there any new benches provided? Comment Number: 3 Comment Originated: 06/26/2012 06/26/2012: The landscape plan is difficult to read. Please remove items such as "relocate existing grease trap". The symbols are too similar. For example, I can not tell the different between the blue chip juniper and the tammy juniper. Comment Number: 4 Comment Originated: 06/26/2012 06/26/2012: Please provide a color elevation. Comment Number: 5 Comment Originated: 06/26/2012 06/26/2012: The tree mitigation plan is unreadable. Please turn off additional layers. Has this tree mitigation schedule been approved by Tim Buchanan, City Forester? There could be an issue with the number of trees. Please revise the tree mitigation table to show total number of existing trees on site. Total number of trees existing on site currently, the total number of existing trees to be protected, total number of trees removed and total number of trees transplated. The tree mitigation plan should be full sized and a separate sheet.