HomeMy WebLinkAboutMOUNTAIN VIEW EYE SPECIALISTS @ RIGDEN FARM - PDP - 5-11 - SUBMITTAL DOCUMENTS - ROUND 1 -A, . Mountain View Eye Specialists — Response to Conceptual Comments Page 8 of 8 Snow Load Live Load: 30 PSF / Ground Snow Load 30 PSF. Frost Depth: 30 inches. Wind Load: 100- MPH 3 Second Gust Exposure B. Seismic Design: Category B. Climate Zone: Zone 5 Energy Code Use 1. Single Family; Duplex; Townhomes: 2009 IRC Chapter 11 or 2009 IECC Chapter 4 2. Multi -family and Condominiums 3 stories max: 2009 IECC Chapter 4. 3. Commercial and Multi -family 4 stories and taller: 2009 IECC Chapter 5. Professionally, Jerry W. Davidson, P.E. For and on Behalf of Perception Design Group, Inc. Mountain View Eye Specialists — Response to Conceptual Comments Page 7 of 8 http://www.colocode.com/ftcollins/landuse/begin.htm. 8. If this proposal is unable to satisfy any of the requirements set forth in the LUC, a Modification of Standard Request will need to be submitted with your formal development proposal. Please see Section 2.8.2 of the LUC for more information on criteria to apply for a Modification of Standard. 9. Please see the Submittal Requirements and Checklist at: http://www.fcgov.com/developmentreview/applications.php. 10. The request will be subject to the Development Review Fee Schedule that is available in the Community Development and Neighborhood Services office. The fees are due at the time of submittal of the required documents for the appropriate development review process by City staff and affected outside reviewing agencies. Also, the required Transportation Development Review Fee must be paid at time of submittal. 11. When you are ready to submit your formal plans, please make an appointment with Community Development and Neighborhood Services at (970)221-6750. Pre -Submittal Meetings for Building Permits Pre -Submittal meetings are offered to assist the designer/builder by assuring, early on in the design, that the new commercial or multi -family projects are on track to complying with all of the adopted City codes and Standards listed below. The proposed project should be in the early to mid -design stage for this meeting to be effective and is typically scheduled after the Current Planning conceptual review meeting. Applicants of new commercial or multi -family projects are advised to call 416-2341 to schedule a pre -submittal meeting. Applicants should be prepared to present site plans, floor plans, and elevations and be able to discuss code issues of occupancy, square footage and type of construction being proposed. Construction shall comply with the following adopted codes as amended: 2009 International Building Code (IBC) 2009 International Residential Code (IRC) 2009 International Energy Conservation Code (IECC) 2009 International Mechanical Code (IMC) 2009 International Fuel Gas Code (IFGC) 2009 International Plumbing Code (IPC) as amended by the State of Colorado 2008 National Electrical Code (NEC) as amended by the State of Colorado Accessibility: State Law CRS 9-5 & ICC/ANSI A117.1-2003. Mountain View Eye Specialists — Response to Conceptual Comments Page 6 of 8 5. Owner will need to submit a C-1 form and One -line diagram to Light & Power Engineering for review. CURRENT PLANNING Contact: Emma McArdle, 970-221-6206, emcardleAfmov.com 1. The current configuration does not appear to meet the "build -to" line requirement of 3.5.3(13)(2)(b) which states that buildings shall be located no more than 15 feet from ROW of an adjoining street if it is smaller than a full arterial. The plan is revised to meet this requirement. 2. At least one main entrance shall open directly onto a connecting walkway with pedestrian frontage. (3.5.3(B)(1) LUC). The plan is revised to meet this requirement. 3. Sidewalks shall be provided along the private drive for pedestrian connectivity. The plan is revised to meet this requirement. 4. Landscaping is required meeting the standards of Article 3 of the LUC. (This includes landscaping of the portion of property south of the drive aisle and landscaping in the parkway along Timberline Rd.) A landscape Plan is attached to address this comment. 5. The proposed development project is subject to a Type 1 review and public hearing, the decision maker for Type 1 hearings is an Administrative Hearing Officer. The applicant for this development request is not required to hold a neighborhood meeting for a Type 1 hearing, but if you would like to have one to notify your neighbors of the proposal, please let me know and I can help you in setting a date, time and location for a meeting. Neighborhood Meetings are a great way to get public feedback and avoid potential hiccups that may occur later in the review process. 6. Please see the Development Review Guide at www.fcgov.com/drg. This online guide features a color coded flowchart with comprehensive, easy to read information on each step in the process. This guide includes links to just about every resource you need during development review. 7. This development proposal will be subject to all applicable standards of the Fort Collins Land Use Code (LUC), including Article 3 General Development Standards. The entire LUC is available for your review on the web at Mountain View Eye Specialists — Response to Conceptual Comments Page 5 of 8 standards at the Developer's expense prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 4. Please contact Joe Olson and Transportation Planning to schedule a scoping meeting and determine if a traffic study is needed for this project. Ward Stanford has waived the traffic report requirement. 5. All public improvements must be designed and built in accordance with the Larimer County Urban Area Street Standards (LCUASS). 6. This project is responsible for dedicating any right-of-way and easements that are necessary for this project. 7. Utility plans will be needed for this project. 8. A Development Agreement will be required with this project. 9. A Development Construction Permit (DCP) must be obtained prior to starting any work on site. 10. Parking setbacks and minimum dimensions are required. Please see LCUASS, Chapter 19. Dimensions are added to the Site Plan sheet 11. The site layout was minimal and all comments were based on what's shown. Other comments may come up when more information is presented with the full submittal. ELECTRIC ENGINEERING Contact: Rob Irish, 970-224-6167, rirish(a,fcsov.com 1. Any relocation or modification to existing electric facilities will be at the owners expense. 2. Owner will be responsible for Electric Capacity Fees and Building Site charges. 3. Electric for this site is available at the Southeast corner of the lot. Conduit has been stubbed out at this location. 4. A pad mount transformer location will need to be coordinated with Light & Power Engineering within 10' of an all weather drive -over surface. Mountain View Eye Specialists — Response to Conceptual Comments Page 4 of 8 mounted on a side of the building other than the side off of which it is addressed, the street name is required to be posted along with the numerals. 006 International Fire Code 505.1 5. TURNING RADII The required turning radii of a fire apparatus access road shall be a minimum of 25 feet inside and 50 feet outside 2006 International Fire Code 503.2.4 and Appendix D103.3 6. FIRE SPRINKLERS The following comments apply if the building will be fire sprinklered: FIRE DEPARTMENT CONNECTION Fire department connections shall be installed remote from the buildings, and located on the street or fire lane side of buildings, fully visible and recognizable from the street or nearest point of fire department vehicle access or as otherwise approved by the fire code official. 2006 International Fire Code 912.2 and PFA Fire Prevention Bureau Policy FIRE LINE REQUIREMENT Buildings that are required to be fire sprinklered shall have a minimum 6-inch fire line unless hydraulic calculations can support a smaller fire line. NFPA 13 (2007) 23.1.3 KEY BOXES REQUIRED Poudre Fire Authority requires a key box ("Knox Box") to be mounted in approved location(s) on every new building equipped with a required fire -sprinkler system or fire -alarm system. Knox Boxes are required to be installed approximately 60 inches above grade and no higher than 72 inches above grade. 2006 International Fire Code 506.1 ENGINEERING DEVELOPMENT REVIEW Contact: Susan Joy, 970-221-6581, sioy(i ,fcsov.com 1. Larimer County Road Impact Fees and Street Oversizing Fees are due at the time of building permit. Please contact Matt Baker at 224-6108 if you have any questions. 2. Transportation Development Review Fee (TDRF) is due at the time of submittal. For additional information on these fees, please see http://www.fegov.com/engineering/dev-review.php 3. Any damaged curb, gutter and sidewalk existing prior to construction, as well as streets, sidewalks, curbs and gutters, destroyed, damaged or removed due to construction of this project, shall be replaced or restored to City of Fort Collins Mountain View Eye Specialists — Response to Conceptual Comments Page 3 of 8 pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter. These requirements may be modified if buildings are equipped with automatic fire sprinkler systems. PLEASE NOTE: Existing hydrants meet this requirement. 2006 International Fire Code 508.1 and Appendix B 2. BUILDING AREA Proposed buildings that exceed 5,000 square feet for Type V construction shall be fire contained or fire sprinklered. 2006 International Fire Code New Table 903.1 and Section 702 3. REQUIRED ACCESS Fire access roads (fire lanes) shall be provided for every facility, building or portion of a building hereafter constructed or moved into or within the PFA�s jurisdiction when any portion of the facility or any portion of an exterior wall of the first story of the building is located more than 150 feet from fire apparatus access as measured by an approved route around the exterior of the building or facility. This fire lane shall be visible by painting and signage, and maintained unobstructed at all times. A fire lane plan shall be submitted for approval prior to installation. In addition to the design criteria already contained in relevant standards and policies, any new fire lane must meet the following general requirements: - Be designed as a flat, hard, all-weather driving surface (asphalt or concrete) capable of supporting fire apparatus weights. Compacted road base shall be used only for temporary fire lanes or at construction sites. - Have appropriate maintenance agreements that are legally binding and enforceable. - Be designated on the plat as an Emergency Access Easement. - Maintain the required minimum width of 20 feet throughout the length of the fire lane (30 feet on at least one long side of the building when the structure is three or more stories in height). If the building is equipped throughout with an approved automatic fire -sprinkler system, the fire code official is authorized to increase the dimension of 150 feet. PLEASE NOTE: The existing Emergency Access Easement fulfills this requirement. However, approved FIRE LANE - NO PARKING signs are required to be in place. 2006 International Fire Code 503.1.1, 503.2.3, 503.3, 503.4 and Appendix D 4. ADDRESS NUMERALS Address numerals shall be visible from the street fronting the property, and posted with a minimum six-inch high numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable). If the numerals are Mountain View Eye Specialists — Response to Conceptual Comments Page 2 of 8 Contact: Glen Schlueter, 970-224-6065, gschlueter(i fcgov.com 1. This site is part of the overall Rigden Farm drainage plan. A letter verifying compliance with that plan is needed from an engineer registered in Colorado. It should address the impervious area proposed and the drainage patterns. Provided 2. Detailed grading and erosion control plans are required now that a specific user has been identified. A detailed grading plan is provided. The erosion control element will be added latter per a conversation with Glen. 3. The city wide Stormwater development fee (PIF) is $6,313.00/acre ($0.1449/sq.ft.) for new impervious area over 350 sq.-ft. and there is a 1,045.00/acre ($0.024/sq.ft.) review fee. These fees are to be paid at the time each building permit is issued. Information on fees can be found on the City's web site at http://www.fcgov.com/utilities/builders-fees.php or contact Jean Pakech at 221- 6375 for questions on fees. PARK PLANNING Contact: Craig Foreman, 970-221-6618, cforeman(iDfcgov.com 1. No comments FIRE AUTHORITY Contact: Carie Dann, 970-219-5337, CDANNnpoudre-fire.org 1. WATER SUPPLY Fire hydrants, where required, must be the type approved by the water district having jurisdiction and the Fire Department. Hydrant spacing and water flow must meet minimum requirements based on type of occupancy. Minimum flow and spacing requirements include: - Commercial and multi -family dwellings 1,500 gpm at 20 psi residual pressure, spaced not further than 300 feet to the building, on 600-foot centers thereafter - Residential within Urban Growth Area, 1,000 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter - Residential outside Urban Growth Area, 500 gpm at 20 psi residual s j� Perception design group, inc.. 6732 W. Coal Mine Ave., Suite 419 Littleton, Colorado 80123 Voice 303-232-9098 Fax 303-232-5255 August 28, 2010 Ms. Emma McArdle City of Fort Collins Community Development Department 281 North College Avenue Fort Collins, Colorado 80522 RE: Mountain View Eye Specialists — Response to Conceptual Comments Dear Ms. McArdle, Comments to the Conceptual Review meeting notes are addressed in the body of the original comment letter below. Many of the comments below are informational in nature. I have typed the responses in bold to those comments requiring comment. Comments: ZONING Contact: Jenny Nuckols, 970-416-2313, inuckols(&fcgov.com 1. Landscaping along Timberline in the parkway needs to be added. Provided 2. Please provide detailed site, landscape plans, as well as elevations. Provided WATER -WASTEWATER ENGINEERING Contact: Roger Buffington, 970-221-6854, rbuffineton(&fcgov.com 1. Existing water and sewer facilities in the vicinity of this site include a 12-inch water main in Custer, an 8-inch water main in the drive at the northwest corner of this site and a sanitary sewer manhole in an easement on the north edge of the site. 2. The Landscape and Irrigation Standards for Water Conservation found at www.fcgov.com/standards will apply to the project. 3. Development fees and water rights will be due at building permit. STORMWATER ENGINEERING