HomeMy WebLinkAboutAPPLEBLOSSOM - 712 W. LAUREL ST. - PDP - 22-10 - REPORTS - DRAINAGE REPORTEXISTING
PROPOSED
4
LAUREL STREET
NORTHERN
ENGINEERING
200 South Colle8e Anme, Suite 100 PNONE970.221A158 FAA. 970.221.4159
FM Coffins, Colorado W524 w .nm0u:mugwg .ing.c
SURFACE
AREA (SF)
%1MPERV.
IMPERV.
AREA (SF)
ROOFTOP 1.837
100%
7,837
CONCRETE 388
100%
388
ASPI(ALT 0
100%
0
PERMEABLE 0
PAVERS
40%
0
LANDSCAPE 10,2BB
O%
0
TOTALS 12,521 TOTAL= 2,223
EXISTING & PROPOSED
IMPERVIOUS AREA
LAURELSTREET
SURFACE
AREA(SF)
%IMPERV.
IMPERV.
AREA(SF)
ROOFTOP 3.528
100%
3,528
CONCRETE SBi
100%
583
ASPR L 7.768
10D%
1,788
PERMEABLE 2,908
PAVERS
40%
1,1&
LANDSCAPE 3,755
O%
0
TOTALS 12,521 TOTAL= 7,021
712 W. Laurel Street
DRAWN BY: A. Reese EXHIBIT
SCALE: 1 in=20R
ISSUED: 03 SEPT 10 1
J
INORTHERN
ENGINEERING
•
Although stormwater quantity detention is not required, stormwater quality mitigation will be
addressed by both temporary and permanent Best Management Practices (BMPs). During
construction, the Contractor will follow the appropriate and applicable City of Fort Collins
standards for erosion and sediment control. Post construction water quality and erosion control
will be achieved by a fully established and stabilized site. All areas disturbed during construction
will receive permanent hardscape, landscape, or building structure.
This portion of the Old Town basin receives regional water quality mitigation in the Udall Natural
Area; therefore, on -site water quality treatment in not required. However, sustainable design
practices and environmental stewardship are part of the goals and vision of this project. As
such, this development will go above and beyond the minimum requirements for stormwater
management. A permeable paver system will be employed, not only to limit the increase in total
impervious area, but also to help cleanse and treat runoff prior to leaving the site. A depressed
rain garden adjacent to the Laurel Street right-of-way will also provide additional water quality
treatment and encourage on -site infiltration. Although not required, other opportunities may be
explored during the Final Plan phase.
While a good portion of historic runoff does travel north and east towards existing single-family
residences, a slight modification to current drainage patterns for the site is proposed in an
attempt to improve this condition. First and foremost, on -site infiltration will be encouraged to
the maximum possible extent. However, sub -surface soils conditions, combined with the
proximity to building foundations, demand an underdrain system. Therefore, a shallow
underdrain will relieve near surface waters and discharge into the proposed rain garden adjacent
to the sidewalk along Laurel Street. The rain garden itself will allow 6 to 12 inches of ponding /
infiltration prior to spilling through a sidewalk chase and into the existing flowline of Laurel
Street. The grading plan allows safe surface passage of excess stormwater towards the alley and
Laurel Street in emergency situations.
The proposed grading concept closely matches existing elevations and drainage patterns, and
only varies in an effort to improve the existing condition and to help ensure that adjacent
properties are not adversely impacted. On -site detention is proven to be unnecessary.
Stormwater quality has been considered, and will be addressed in a manner well above and
beyond the minimum requirements. Therefore, it is my professional opinion that the triplex and
duplex proposed at 712 W. Laurel Street (Replat of Lot 17 and Lot 18, Block 5, Westlawn
Addition) satisfy all applicable stormwater criteria.
Please do not hesitate to contact me if you have questions or require additional information.
Sincerely
/03/
'4QftftmmGW0 LEED
Nicholas W. Haws, PE AP
cc: Mark Goldrich & Prue Kaley — Owners
Dave Derbes, LEED AP — Brinkman Construction
Ian Shuff, AIA, LEED AP — Aller-Lingle-Massey Architects
Jim Birdsall, ASLA, RLA — The Birdsall Group
Page 2 of 2
D`:F'rofecs57A-OOri6ra!naa=_\Reoods\Dainaee Reunrturalna.e-Letter 03-03-lOdoc
J
NORTHERN
ENGINEERING
Drainage Letter Report
Date: September 3, 2010
ADDRESS: PHONE:970.221.4158 :
200 S. College Ave. Suite 100 WEBSITEWEBSITEnengineering.com
Fort Collins, CO 80524 FAX: 970.221.4159
Project: 712 W. Laurel Street
Replat of Lots 17 and 18, Block 5, Westlawn Addition
Fort Collins, Colorado
Attn: Mr. Wes Lamarque
City of Fort Collins Stormwater Utility
700 Wood Street
Fort Collins, Colorado 80521
Dear Wes:
Project No. 574-001
This letter serves to address the stormwater impacts of the above referenced residential
redevelopment. The existing home is situated towards the western portion of the site, but does
occupy portions of both lots. The site currently consists of rooftop, concrete walks and patio,
turf, trees, and other vegetation. It presently functions similar to a 'B' lot, with historic drainage
being split towards the northeast and southeast. The unpaved alley adjacent to the western
properly line has a high point such that it too drains to the north and towards Laurel Street on
the south. The total impervious area of the existing site is approximately 2,223 square -feet.
The proposed redevelopment will completely remove all existing above -grade structures and
hardscape. The new project will consist of a triplex on the western lot, a duplex on the eastern
lot, and a permeable paver courtyard between the two. A new parking lot will be constructed
north of the residential units, over half of which will consist of permeable pavers. The pedestrian
connections from the units south to Laurel Street will be made with shallow boardwalks,
allowing 100% of the rainwater to pass through the decking material. The total impervious area
of the proposed redevelopment is roughly 7,021 square -feet.
The off -site alley adjacent to the project will get paved with a cross-section according to LCUASS
Figure 7-12F. The existing curb cut and concrete apron to Laurel Street will remain as -is. The
area of paved alley draining south across the Laurel sidewalk will be approximately 650 square -
feet, which is less than the maximum 750 square -feet allowed by LCUASS.
The site is located in the Old Town master drainage basin, and therefore, on -site detention is not
required so long as the increase in impervious area is less than 5,000 square -feet. The total
increase in impervious area proposed with this development is approximately 4,798 square -feet
(7,021 — 2,223). A detailed breakdown of the existing and proposed impervious areas, along
with graphical site depictions can be found on the attached Exhibit 1.
Page 1 of 2
0:\Proiects\574-001�Oravtaee\ReoorslDrainaee Reo,MDminaoe-Letter 09-03-10.dos