HomeMy WebLinkAboutAPPLEBLOSSOM - 712 W. LAUREL ST. - FDP - 22-10/A - CORRESPONDENCE -Department: PFA Topic: Fire Number: 61 GENERAL NOTE Issue Contact: Carie Dann Created: 11 /2/2010 Please put a general note on the Site Plan that reads: "A residential fire sprinkler system approved by Poudre Fire Authority will be installed throughout the triplex." Response: The requested note will be added prior to printing mylars. Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington Topic: Landscape Plan Number: 62 Created: 11/2/2010 [11/2/10] Adjustthe tree placement in front of Bldg A to provide the required separation from the water and sewer services. Response: The trees have been adjusted. Page 5 Respmse: Detail 105 has been labeled as private, and the requested details have been added. Please label detail 106 as "Private" and if any of the curbs are to be constructed in Public ROW, then please use the appropriate City detail. Response: Detail 106 has been labeled as private, and the appropriate city curb detail has been added. Please remove detail 706 as that is for driveways taken off a public street. Response: Detail has been removed. Department: Forestry Issue Contact: Tim Buchanan Topic: Landscape Plan Number: 63 Created: 11 /2/2010 [11 /2/10] The parking space just to the west of the Norway maple is very close to the tree trunk. To protect the root system the edge of the parking space could be a landscape timber placed at grade and not a concrete curb that requires footer. If possible, by not making that area a parking space it would further protect the root system of this tree. Can this parking space be shifted to the west? Response: Keeping the parking space is very desirable for the owners. The proposed grading in this area has been designed so that the maximum cut (including subgrade) in the root zone does not exceed 3". Is there a storm drain shown between the buildings? It's not clear on the landscape plan what this dark dashed line is. If it is a new storm drain coring it under the root system would protect the roots on the east side of the tree. Response: The storm pipe is not expected to have any significant impact on the root system. Department: Light & Power Issue Contact: Doug Martine Topic: Light & Power Number: 34 Created: 10/19/2010 [10/19/10] The most southerly clean -out for the sewer service to building A appears to be precisely in the same location as 2 electric lines, and very close to the fiber optic line. If any of these lines needs to be relocated, the costs will be in addition to normal electric development charges. Response: The cleanout location has been moved to avoid the utility conflicts. It is understood that the cost to relocate any other utilities are in addition to normal charges. Number: 35 Created: 10/19/2010 [10/19/10] The utility plan shows the electric meter for building A on the west side, and the meter for building B on the east side of the house. These meters need to be on the opposite side of each house. Response: The meters have been moved. Number: 36 Created: 10/19/2010 [10/19/10] When final, an AutoCad drawing of the site utility plan needs to be sent to Terry Cox at TCOX @ FCGOV.COM. Acknowledged. Page 4 Number: 42 Created: 10/27/2010 [10/27/10] Please show existing features within at least 50' to the west. Response: The requested information has been provided. Number: 43 Created: 10/27/2010 [10/27/10] Please label all storm lines as public or private and work with Wes Lamarque in Stormwater if you have any questions. Response: The storm lines have been labeled as private. Number: 44 Created: 10/27/2010 [10/27/10] Please label all slope ratios on the grading sheet. Some of the slopes in the front look pretty steep and while we don't regulate what you do on private property unless it affects the neighbors or public row, this may be a maintenance problem for you in the future. There is one area of concern and that's along the east side of the property. Can you construct this area without going into the neighbor's yard? Or if the slope is steep enough, you may need a retaining wall here or it will wash out into the neighbor's yard with every good rain. Let me know what you think. Response: Additional slope arrows have been provided on the grading sheet. Slopes in the front do not exceed 4:1 except for short durations directly at the stairs. Along the eastern property line, slopes are for the most part 4:1 or less. There are a couple of short segments that are at 3:1, however there are no concentrated flows at these locations, and it is anticipated that the proposed landscaping will provide sufficient slope stabilization to mitigate any erosion concerns. Number: 46 Created: 10/27/2010 [10/27/101 Please dimension all drives aisles and parking spots. Response: All drive aisles and parking spots have been labeled. Number: 49 Created: 10/27/2010 [10/27/10] Please provide stationing for the driveway off the alley and dimension the driveway width. Response: Stationing has been provided as has a dimension for the driveway width. Number: 51 Created: 10/27/2010 [10/27/10] Please provide both east and west alley flowline profiles, station the driveway (show in profile and plan view), and show cross slopes in the plan view. Response: Both the east alley flowline and west alley edge are now profiled. The requested cross slopes have been added. Number: 53 [10/27/10] Detail Sheet: Created: 10/27/2010 Are details 708 and 710 needed? I don't see a crosspan shown on the plan sets. Response: The details have been removed. Please label detail 107 as "Private". Response: The detail has been labeled as "Private". You can leave detail 105 as is, IF labeled as "Private". All public sidewalks curb and gutters, etc must be constructed per LCUASS, so please include details 701, 803, 1601, 1602. Page 3 Number: 60 Created: 10/27/2010 [10/27/10] Per Pavement Management: The Laurel Street overlay was completed on 7/31/06. Any street cuts made within 5 years of that date will have triple street cut fees applied. Acknowledged. Topic: Landscape Plan Number: 55 Created: 10/27/2010 [10/27/101 Please remove the words "Final Compliance Plan" off the title. Response: Title removed. Number: 56 Created: 10/27/2010 [10/27/10] Please label and dimension all easements. Please include the sight distance note on the plan set and confirm that all landscaping within the sight distance easements comply with the height restrictions (see plat). Response: Easements have been labeled. Sight distance notes have been added to the plan. Number: 57 Created: 10/27/2010 [10/27/10] Please show all utilities. Response: All utilities are now shown. Number: 58 Created: 10/27/2010 [10/27/10] Please change the note as shown on the redline. The landscape plan is required to show some of these items and if there are any walls to be constructed, they must be clearly shown on ALL plan sets and include the top, bow. If a footing is required, additional comments may apply. Response: There are no walls proposed, the note was a leftover from a previous plan. The notes have been adjusted accordingly. Topic: Site Plan Number: 54 Created: 10/27/2010 [10/27/10] Please remove the words "Final Compliance Plan" off the title. Response: Title removed. Topic: Subdivision Plat Number: 37 Created: 10/27/2010 [10/27/10] Minor comment in the Statement of Ownership and Subdivision: Please change the H in Have caused to a lower case h. Response: The "H" has been changed to an "h". Number: 38 Created: 10/27/2010 110/27/10] Note 4: need to add who maintains this easement as well. Question... what happens if the owner of Appleblossom Sub decides to sell one of the lots off? Shouldn't the easement be dedicated to an HOA instead? Response: The note has been modified. Number: 39 Created: 10/27/2010 [10/27/10] Add a Note 5 that defines the ownership and maintenance of the 20' private access and drainage easement. Response: The note has been added. Topic: Utility Plan Number: 41 Created: 10/27/2010 [10/27/10] General Notes: Correction required to note number 19 and 41. Response: The notes have been corrected. Page 2 4in STAFF PROJECT REVIEW Citv of Port Collins Prue Kaley, Mark Goldrich Date: 11/3/2010 The Birdsall Group - Jim Birdsall 444 Mountain Ave. Berthoud, CO 80513 Staff has reviewed your submittal for 712 W. LAUREL STREET PDP - TYPE II AND FINAL PLANS (aka Appleblossom LLC), and we offer the following comments: ISSUES: Department: Engineering Issue Contact: Susan Joy Topic: General Number: 40 Created: 10/27/2010 [10/27/10] Can all construction take place within the lot boundaries and public row or will construction easements be required from the neighboring properties to the east and west? Response. Yes, all construction will take place within the lot boundaries and public ROW. No construction easements are needed at this time. Number: 45 Created: 10/27/2010 [10/27/10] All plan sets: Please dimension all new and existing sidewalks. The site plan has most of them dimensioned but some are missing. The utility plan needs all of them dimensioned. Response: Where walks are called out, they have been dimensioned. Number: 47 Created: 10/27/2010 [10/27/10] Anywhere a parking stall has been reduced to 17' to overhang a sidewalk by 2', the sidewalk width must be increased by 2'. Response: N/A Number: 48 Created: 10/27/2010 [10/27/10] Please see figure 7-12F for the driveway connection requirements to the alley (radius curb returns are not allowed, use flared ends instead). This is to reduce the speed at which people enter and exit the parking lot and keep the area generally safer for everyone in it. Response: The driveway now has flares rather than radii. Number: 50 Created: 10/27/2010 [10/27/10] Is the area immediately to the north of building B for parallel parking? I can't really tell. It looks like it but its not labeled or dimensioned as if they are. If they are parking spots, a 24' wide drive aisle is required for double loaded parking and there is only 20' shown. Either the parallel spots will have to be removed or they'll have to shift 4' to the south which will affect the building layout as well. Fdesponse: The parallel parking has been removed. Number: 52 Created: 10/27/2010 [10/27/10] An 8' utility easement has not been provided along the east side of the alley as required by current street standards. The utility companies must approve this by providing a comment accepting this condition with this round of review or by a separate email to me at sjoy@fcgov.com Acknowledged. Number: 59 Created: 10/27/2010 [10/27/10] Site, Landscape, Plat and Utility Plans must read comments under all sections and coordinate with each other. Acknowledged. Page I f-EStoo NSC C.ETTt K