HomeMy WebLinkAboutWILLOW BROOK, FILING THREE - PDP - 32-10 - CORRESPONDENCE - (6)Number: 24 Created: 12/7/2010 [12/7/10] Please provide the existing ROW widths on Rock Creek and Lady Moon on the Utility sheet. Number: 26 Created: 12/7/2010 [12/7/10] All ADA ramps are required to be directional. See redlines. Number: 28 Created: 12/7/2010 [12/7/10] According to the Master Street Plan, Cinquefoil is a collector level street. Therefore, the minimum driveway spacing for drives off of Cinquefoil would be 30 feet edge to edge. All of the drives off of Cinquefoil will need to conform to this. Number: 29 Created: 12/7/2010 [12/7/10] Please remove "PDP Plat" from the top of the plat within the utility plan. It should however be clearly noted that this plat is for reference only. Number: 30 Created: 12/7/2010 [12/7/10] The following City street cut note should be added to the demo, utility, and grading sheets. Limits of street cut are approximate. Final limits are to be determined in the field by the City Engineering Inspector. All repairs to be in accordance with City street repair standards. Number: 32 Created: 12/7/2010 [12/7/10] As noted in Conceptual Review, lots are not allowed to have double frontages except when adjacent to an arterial roadway. Is a tract of land owned and maintained by the HOA proposed with this development to address the requirement? It is difficult to tell on the current plans what is proposed. Is the tract proposed as the 9 foot utility easement? Why is there another 8 foot utility easement behind the existing easement? Also, the tract should not be called out as open space; it should be a utility and access easement. Number: 36 Created: 12/7/2010 [12/7/10] On the plat, please call out the existing stardust lane as being vacated by ordnance # Number: 41 Created: 12/8/2010 [12/8/10] City signature blocks are needed on all sheets within the utility plan. On sheets 9 and 10 they are missing. Number: 44 Created: 12/9/2010 [12/9/10] The north arrow on page 11 is incorrect Number: 45 Created: 12/9/2010 [12/9/10] Centerline and eventually flowline profiles of the internal streets need to be shown through Galileo Drive. Number: 46 Created: 12/9/2010 [12/9/10] Please call out the inside and outside radii of the curves on the internal streets. Page 2 imSTAFF PROJECT REVIEW ON of Fort Collins Jen Torrey Date: 12/10/2010 TST Inc 748 Whalers Way Fort Collins, CO 80525 Staff has reviewed your submittal for WILLOW BROOK, THIRD FILING PDP - TYPE I (Ref.#8-99), and we offer the following comments: ISSUES: Department: Engineering Issue Contact: Andrew Carney Topic: Utility Plan Number: 16 Created: 12/7/2010 [12/7/10] Please remove "Project Development" from the title of the utility plans. It should just read "Utility Plans For". Number: 17 Created: 12/7/2010 [12/7/10] Please complete General Note #19, it was left incomplete. Number: 18 Created: 12/7/2010 [12/7/10] Not needed prior to hearing but added as a reminder: Please add the following note to the cover sheet of the Utility Plans (Checklist item I.J.): I hereby affirm that these final construction plans were prepared under my direct supervision, in accordance with all applicable City of Fort Collins and State of Colorado standards and statutes, respectively; and that I am fully responsible for the accuracy of all design, revisions, and record conditions that I have noted on these plans. Number: 19 Created: 12/7/2010 (12/7/10] Not needed prior to hearing but added as a reminder: Please add the following note to the cover sheet of the Utility Plans (Checklist item I.M.): These plans have been reviewed by the Local Entity for concept only. The review does not imply responsibility by the reviewing department, the Local Entity Engineer, or the Local Entity for accuracy and correctness of the calculations. Furthermore, the review does not imply that quantities of items on the plans are the final quantities required. The review shall not be construed in and reason as acceptance of financial responsibility by the Local Entity for additional quantities of items shown that may be required during the construction phase. Number: 20 Created: 12/7/2010 [12/7/10] Not needed prior to hearing but added as a reminder: Finish grade elevations are needed for streets, lot corners, and finish floors/top of foundation of buildings for all lots. Number: 22 Created: 12/7/2010 [12/7/10] Not needed prior to hearing but added as a reminder: Please add the following statement on the utility and grading sheets: The top of foundation elevations shown are the minimum elevations required for protection from the 100-year storm. Page 1 Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque Topic: Stormwater Number: 21 Created: 12/7/2010 [12/7/10] Stormwater is ready for a hearing. Number: 23 Created: 12/7/2010 (12/7/10] At final, a detailed lot grading plan is required. Number: 25 Created: 12/7/2010 [12/7/10] On plat, please label storm sewer easement as drainage easement. Number: 27 Created: 12/7/2010 [12/7/10] The storm sewer in Endeavour Lane needs to be in the street. All the utilities should be able to fit. A utility coordination meeting may be needed. Comments from Current Planning: The perimeter fence along Lady Moon appears to match the existing perimeter fence along Kechter Road, with one exception. Please add the stone (or stone -like product) columns, with capstone, at regular intervals in order to match the Kechter Road fence. Matching the existing fence will bring a measure of cohesiveness to the overall neighborhood. Be sure to add the notes to the Site Plan and Plat that were discussed at the staff review meeting. Also, be sure to replace "Cambridge" with "Lady Moon." Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Sincerely: Ted Shepard Chief Planner Page 6 Department: Technical Services Issue Contact: Jeff County Topic: Landscape Plan Number: 10 Created: 12/6/2010 [12/6/10] There are many line -over -text issues on Landscape Plan sheet 2. Number: 11 Created: 12/6/2010 [12/6/10] Why are the sewer & water shown on Landscape Plan sheet 2? Topic: Site Plan Number: 7 Created: 12/6/2010 [12/6/10] There are many line -over -text issues on the Site Plan. Number: 8 Created: 12/6/2010 [12/6/10] Please add a legal description to the Site Plan. Number: 9 Created: 12/6/2010 [12/6/10] Why are the sewer & water shown on the Site Plan? Topic: Subdivision Plat Number: 2 Created: 12/6/2010 [12/6/10] The Subdivision Plat boundary & legal close. Number: 3 Created: 12/6/2010 [12/6/10] There are many line -over -text issues on the Subdivision Plat. Number: 4 Created: 12/6/2010 [12/6/10] Please change the title text on the Subdivision Plat sheet 1 to solid. Number: 5 Created: 12/6/2010 [12/6/10] Please correct the Basis of Bearings statement. It should read clockwise. Number: 6 Created: 12/6/2010 [12/6/10] Please remove "PDP Plat" from the title of the Subdivision Plat. Topic: Utility Plan Number: 12 Created: 12/6/2010 [12/6/10] Please correct the index on sheet 1 of the Utility Plans. Number: 13 Created: 12/6/2010 [12/6/10] Please contact Technical Services - 221-6588 or Surveying - 221-6605, about the benchmarks on sheet 1 & 2 of the Utility Plans. Number: 14 Created: 12/6/2010 [12/6/10] There are line -over -text issues on sheet 7 of the Utility Plans. Number: 15 Created: 12/6/2010 [12/6/10] Please add north arrows to sheet 11 of the Utility Plans. See redlines. Page 5 • Residential within Urban Growth Area, 1,000 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter • Residential outside Urban Growth Area, 500 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter. These requirements may be modified if buildings are equipped with automatic fire sprinkler systems. PLEASE NOTE: Fire hydrant location is acceptable. 2006 International Fire Code 508.1 and Appendix B Number: 33 Created: 12/7/2010 STREET NAMES Street names shall be reviewed and verified by LETA prior to being put in service. PLEASE NOTE: While proposed street name of Voyager is acceptable, the proposed street name of Endeavour is may not be permitted. The submitted plans spelled it two ways (Endeavour and Endeavor) - thus, it fails to meet the Larimer County Rules of the Streets requirement that the commonly accepted spelling be used. Please consider submitting an alternative suggestion. Additionally, you must also receive LETA approval for suggested names. P.F.A. will continue to discuss using this name with the various entities involved in street naming for additional feedback. 2006 International Fire Code 502.2 2006 International Fire Code 505.2 Number: 34 Created: 12/7/2010 ADDRESS NUMERALS Address numerals shall be visible from the street fronting the property, and posted with minimum six-inch high numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable). If the numerals are mounted on a side of the building other than the side off of which it is. addressed, the street name is required to be posted along with the numerals. PLEASE NOTE: If any front doors front to Tract A, PFA will require address numerals on both the front and back (street) sides of the residences. 2006 International Fire Code 505.1 Number: 35 Created: 12/7/2010 PHASING If phasing produces any dead-end streets longer than 150 feet, PFA will require the construction of a temporary turnaround at least 100 feet in diameter. PFA will also review for any other access or water supply issues. Department: Traffic Operations Issue Contact: Ward Stanford Topic: Landscape Plan Number: 43 Created: 12/8/2010 [12/8/10] The Landscape Plan does not indicate the tree specie being used on the public roadways. Please label the tree symbols on the plan. Topic: TIS Number: 42 Created: 12/8/2010 [12/8/10] Speeds stated for Harmony and for Kechter are 5 mph off. The evaluation was done with slower speeds which in most cases would be a more conservative analysis. Please revise. A memo form of revision is acceptable. Page 4 Number: 47 Created: 12/9/2010 [12/9/10] Not needed prior to hearing however in final compliance be sure to include detail 7-27 for each of the two proposed intersections and also include all of the required spot elevations and dimensions. Number: 48 Created: 12/9/2010 [12/9/10 ] Not needed prior to hearing however in final compliance please create a detail for each of the street widening locations and show them as detail 7-24 with all of the information and dimensions called out. Number: 49 Created: 12/10/2010 . [12/10/10] 1 have yet to hear a verdict from Transportation Planning regarding the ADA ramps crossing Galleo Drive therefore I will provide an update when a decision has been made. Department: Forestry Issue Contact: Tim Buchanan Topic: Landscape Plan Number: 37 Created: 12/8/2010 [12/8/10] Street trees need to be from the City Street Tree List and labeled as to type on the final landscape plan. Cimarron Ash is listed in the plant list, but ash is no longer on the street tree list. The note about transplanting trees along Cinquefoil should state that only trees that conflict with driveways will be transplanted. The current note sounds like they will all be transplanted. Planting note 16 should indicate that 10 feet separation from main lines and 6 feet from service lines. Department: Light & Power Issue Contact: Bruce Vogel Topic: Utility Plan Number: 38 Created: 12/8/2010 [12/8/10] Electric power for the project is located in Galileo Drive and Cinquefoil Lane and will not be a problem to bring into the site. Number: 39 Created: 12/8/2010 (1.2/8/10] The streetlight in the middle of lot #5 will be relocated to a nearby property line at time of construction. Number: 40 Created: 12/8/2010 [12/8/10] Normal electric development charges will apply to the site. Department: PFA Issue Contact: Carle Dann Topic: Fire Number: 31 Created: 12/7/2010 WATER SUPPLY. Fire hydrants, where required, must be the type approvedby the water district having jurisdiction and the Fire Department. Hydrant spacing and water flow must meet minimum requirements based on type of occupancy. Minimum flow and spacing requirements include: • Commercial and multi -family dwellings 1,500 gpm at 20 psi residual pressure, spaced not further than 300 feet to the building, on 600-foot centers thereafter Page 3