Loading...
HomeMy WebLinkAboutPROSPECT 7-ELEVEN STORE NO. 35506 - FDP - FDP120001 - CORRESPONDENCE -Department: Zoning Contact: Noah Beals, 970.416-2313, nbeals(a)fcuov.com Topic: General Comment Number: 1 Comment Originated: 06/13/2012 06/13/2012: The elevation drawings indicate utility equipment attached to both the north and west walls with a note that these are screened with landscaping. Since the landscaping usually takes time to grow into a fully effective screen and foliage is seasonal the note should also_ . include the equipment to be painted to match the building. Applicant indicated the RTU's would be screened by parapet wall. Since the parapet wall varies in height the RTU's should be painted to match the building also. A note on the plans should state the RTU's to painted to match building. I . Department: Stormwater Engineering r \ Contact: Wes Lamarque, 970.416.2418, wlamargue@fcgov.com Topic: General Comment Number: 1 Comment Originated: 06/07/2012 06/07/2012: Please provide all drainage details on thetility plan set. This includes a detail for i, the water quality falt area/pond. Please contact Basil Fiamdan at 224-6035 to obtain soil media eci�ti�s and eta se Comment Number: 2 Comment Originated: 06/07/2012 vo S Vim. a I O6/07/2012: Please provide a drainageseasement for the limits of the waterquality flat l area/pond. Q� Pond. 1� --w-4 oci,(YY1(�Fla% UjailiQlk Department: Technical Services IS `�Contact: Jeff County, 970-221.6588, jcountyna fcgov.com Topic: Building Elevations Comment Number: 4 06/13/2012: No comments. Topic: Construction Drawings Comment Number: 5 06/13/2012: No comments. Topic: Landscape Plans Comment Number: 2 O6/13/2012: No comments. Topic: Lighting Plan Comment Number: 3 O6/13/2012: Please add a north arrow to sheet P1 Topic: Site Plan Comment Number: 1 O6/13/2012: No comments. Comment Originated: 06/13/2012 Comment Originated: 06/13/2012 Comment Originated: 06/13/2012 Comment Originated: 06/13/2012 Comment Originated: 06/13/2012 Department: Water -Wastewater Engineering Contact: Roger Buffington, 970-221.6854, rbuffington a(7.fcgov.com Topic: Construction Drawings Co ment Number: 1 Comment Originated: 06/12/2012 06/12/2012: There is no re uirement for a separate irrigation service. Have you considered �J abandoning the existin 3/4" ater service and using the proposed 1" service for both domestic and irrigation? PC 0Sak)tQ 6ACf fk 0- Department: Zoning , ��k-/ \ '] Contact: Noah Beals, 970.416.2313, nbealsla.fcgov.com J� n Department: Engineering Development Review Contact: MarcVirata, 970.221.6567, mvirata@fcgov.com Topic: Construction Drawings Comment Number: 2 Comment Originated: 06/07/2012 06/07/2012: Please add LCUASS details 702 and 1601 to the details sheet. Comment Number: 3 Comment Originated: 06/07/2012 06/07/2012: Please correct references to LCUASS, which are shown as LCUUSA in some j instances. . S P1 Topic: General U� `t" Comment Number: 4 Comment Originated: 06/07/2012 06/07/2012: The legal descriptions for the easements and right-of-way dedications appear in concept and will be reviewed for accuracy/closure by Technical Services. We will need the fully signed deeds of dedication in order to complete sign -off of the construction plan mylars. a` -We ire'- lYQ , & s.e iavxj toy 3 Department: Environmental Planning Contact: Lindsay Ex, 970-224-6143, lex(a)fcgov.com Topic: General Comment Number: 1 Comment Originated: 06/08/2012 O6/08/2012: The native seed mix for the site is excellent. Otherwise, no comments. Department: PFA Contact: Ron Gonzales, 970.416-2864, rgonzales(aoudre-fire.org Tonic: General Comment Number: 1. Comment Originated: 06104/2012 06104/2012: permit to remove UST's is required prior to commencement of this work for the property owner. These shall be placed upon transports the day they �arpe scheduled for removal from the ground. There shall not be any storage on site of used 0M, Comment Number: 2. Comment Originated: 06/04/2012 06/04/2012: A permit is required to install new UST's prior to installing new UST's. If they are to be placed in existing hole, it must be deemed "clean" by report from State Oils prior to using the same hole. Comment Number: 3. Comment Originated: 06/04/2012 06/04/2012: Cutsheets on the new tanks and piping systems shall be submitted for review prior to installation. Comment Number: 4. Comment Originated: 06/04/2012 06/04/2012: The installing contractor shall schedule with the PFA a convenient day to install and shall provide 48-hrs notice prior to install. A PFA tank inspector is required to be on -site during all critical testing periods of the installation to witness and verify testing of tanks and piping systems. Department: Stormwater Engineering Community Development and City of Neighborhood Services 281 North Avenue iOrt Collin POB x5 Oollege Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax tcgov. com/devetopmentreview June 13, 2012 Sara Streeter Verdad Real Estate 1121 Grant St Denver, CO 80203 RE: Prospect 7-Eleven Store No. 35506, FDP120001, Round Number 1 Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Courtney Levingston, at 970-416-2283 or clevingston@fcgov.com. Comment Summary: Department: Current Planning Contact: Courtney Levingston, 970-416-2283, clevingstonnafcgov.com Topic: General Comment Number: 1 Comment Originated: 06/08/2012 06/08/2012: Please add a note on the elevations stipulating th use of clear glass to be used in all commercial storefront windows and doors and mirror glass with a reflectivity or opacity of greater than 60% is prohibited. (Land Use Code Section 3.5.1(E)) Comment Number: 2 Comment Originated: 06/08/2012 06/08/2012: Please change the signature block to say "Director of Community Development and Neighborhood Services" under the signature area. Comment Number: 3 Comment Originated: 06/13/2012 06/13/2012: Please make sure the property owner signs the mylars with a black sharpie and the signature dries the appropriate ammount of time so it does not smudge. Department: Engineering Development Review Contact: Marc Virata, 970.221.6567, mvirataOfcgov.com Topic: Construction Drawings Comment Number: 1 Comment Originated: 06/07/2012 06/07/2012: The stop sign shown at the driveway entrance to the south should be moved to the other side of the sidewalk, keeping the stop sign out of public right-of-way.