Contact: Mark Taylor, , mtavlorlrDfcgov.com
Topic: Floodplain
Comment Number: 1 Comment Originated: 10116/2012
Any and all construction activities in the flood fringe must be preceded by an approved
Floodplain Use Permit, $25 fee, and approved plans (at time of building permit). This can be
found online at: http://www.fcgov.com/utilities/what-we-do/stormwater/flooding/forms-documents
Please contact Mark Taylor, 970.416.2494, mtaylor@fcgov.com with questions.
Comment Number: 3 Comment Originated: 10/18/2012
10118/2012: On enlarged site plan sep. sheet, please show (call out) the separation between
flood fringe and monopine base.
Comment Number: 4 Comment Originated: 10/18/2012
10/1812012: Is the tower (monopine trunk) and the contents of waterproof? If so, please add the
following note on the site plan: "The contents of the tower and the tower itself is waterproof. In
the event of flooding, the City of Fort Collins is not responsible for any damage."
If not, please call Mark Taylor.
Contact: Wes Lamarque, 970.416-2418, wlamarguena.fcgov.com
Topic: General
Comment Number: 2
Comment Originated: 10/16/2012
10/16/2012: Please document on the site plan how much the new facility within the lease area
will increase the impervious area. (rooftop, concrete, asphalt, etc.)
Department: Technical Services
Contact: Jeff County, 970.221.6588, icountyna,fcgov.com
Topic: Building Elevations
Comment Number: 4 Comment Originated: 10/16/2012
10/16/2012: There are line over text issues on all(including color 11"x17") sheets A3.0 & A3.1.
Comment Number: 5 Comment Originated: 10/16/2012
10/16/2012: Please trim everything shown outside of the border on the color 11 "x17" sheets
A3.0 & A3.1.
Topic: Construction Drawings
Comment Number: 3 Comment Originated: 10/16/2012
10/16/2012: Please change the elevation & datum of the benchmark on sheet A2.1. The City of
Fort Collins requires the 1929 unadjusted datum.
Topic: General
Comment Number: 1
10/16/2012: Please add a legal description to sheet T1.0.
Comment Number: 2
10/16/2012: Please add a sheet index to sheet T1.0.
Comment Originated: 10/16/2012
Comment Originated: 10/16/2012
Department: Light And Power
Contact: Doug Martine, 970-224.6152, dmartinena.fcgov.com
Topic: General
Comment Number: 1 Comment Originated: 10/01/2012
10/01/2012: Light & Power Engineering will need a Commercial Service Information (C-1) form
completed. Electric development and system modifications will apply. Please coordinate
power requirements with Light & Power Engineering at (970)221-6700.
Department: PFA
Contact: Jim Lynxwiler, 970.416.2869, jlynxwilerCa ooudre-fire.org
Topic: General
Comment Number: 1
10/17/2012: FIRE LANE
Comment Originated: 10/17/2012
Shall be designated on the plat as an Emergency Access Easement.
Maintain the required 20 foot minimum unobstructed width & 14 foot minimum overhead
clearance.
Be designed as a flat, hard, all-weather driving surface capable of supporting 40 tons.
Be visible by signage and maintained unobstructed at all times.
2006 International Fire Code 503.2.3, 503.3, 503.4 and Appendix D
Comment Number: 2
10/17/2012: TURNING RADII
Comment Originated: 10/17/2012
The required turning radii of a fire apparatus access road shall be a minimum of 25 feet inside
and 50 feet outside.
International Fire Code 503.2.4 and Local Amendments
Comment Number: 3
10/17/2012: PREMISE IDENTIFICATION
Comment Originated: 10/17/2012
New and existing buildings shall be plainly identified. Address numbers shall be visible from
the street fronting the property, plainly visible, and posted with a minimum of six-inch numerals
on a contrasting background.
2006 International Fire Code 505.1
Comment Number: 4
10/17/2012: BATTERY STORAGE SYSTEMS
Comment Originated: 10/17/2012
Stationary storage battery systems used for standby power and having an electrolyte capacity
in excess of 50 gallons of stationary lead acid or 1,000 Ibs lithium ion shall comply with Section
608 and Table 608.1 of the International Fire Code.
Comment Number: 5
10117/2012: DIESEL GENERATOR
Comment Originated: 10/1712012
Storage systems for diesel fuel shall provide for spill control and secondary containment when
the storage vessel exceeds 55 gallons. Other conditions apply to combustible liquid storage.
Refer to Sections 2704 and 3404 of the 2006 International Fire Code for more details.
Department: Stormwater Engineering
Contact: Mark Taylor, , mtavlorofcgov.com
Department: Forestry
Contact: Tim Buchanan, 970-221.6361, tbuchanan(D.fcgov.com
Topic: General
Comment Number: 3 Comment Originated: 10/19/2012
10/19/2012: Watering:
Thoroughly soak the soil ball and surrounding soil at planting.
Following transplanting, and through the first three growing seasons, trees shall receive
supplemental watering at a rate of minimum of 50 gallons of water each week during the
growing season (from April through September); and 50 gallons every four weeks during the
winter (October through March). Water shall be applied over the top of the soils ball. If trees
appear stressed apply additional water at each irrigation cycle. Length of water cycles may be
modified slightly as determined appropriate by a qualified landscape contractor.
Comment Number: 4
Comment Originated: 10/19/2012
10/19/2012: Landscape contractor to contact the City Forester at the end of three seasons of
tank irrigation to determine if trees can survive without additional irrigation or if addition irrigation
will be required.
Topic: Landscape Plans
Comment Number: 1
Comment Originated: 10/16/2012
10/16/2012: Adding a few additional trees is possible with the spacing shown on the landscape
plan. This could provide better initial screening of the base per LUC 3.2.1(E).
Comment Number: 2
10/19/2012: Planting detail:
Include 8 inch water basin at edge of planting hole
Mulch 4 inches deep within planting basin
No need to wrap tree trunks on conifers
Don't over excavate the depth of the tree planting pit
Remove top half of wire basket and pull burlap back off the top of the ball
Remove all twine and labels
Surface of tree ball to be 1 inch higher that existing grade
Department: Light And Power
Contact: Alan Rutz, 970.224.6153, arutz(D.fcgov.com
Topic: General
Comment Number: 2
10116/2012: Anew transformer will need to be installed for this project.
Contact: Doug Martine, 970-224.6152, dmartine(rDfcgov.com
Topic: General
Comment Originated: 10/19/2012
Comment Originated: 10/16/2012
Department: Engineering Development Review
Contact: Marc Virata, 970.221.6567, mvirata(a)fcgov.com
Topic: General
Comment Number: 2 Comment Originated: 10/16/2012
10/16/2012: The "New 16-10" Access & Utility Easement" should be revised to 20' in width and
be dedicated as an "Emergency Access & Utility Easement" per discussion with PFA at the
10/17 Staff Review. The dedication of this easement (and any easements) to the City requires
deeds of dedication in an approved City format (the template will be emailed separately) along
with a $250 fee for each easement, and county recordation costs in an amount to be
determined. The required deed(s) of dedication will need to be in place prior to final plan
approval of the project (after public hearing).
Comment Number: 3
Comment Originated: 10/16/2012
10116/2012: The "10' Utility Easement" should be indicated as "Existing 10' Utility Easement".
Comment Number: 4 Comment Originated: 10116/2012
10/16/2012: The City typically uses a "Utility Plan" as a construction plan set that is filed
separately from the site plan and is approved by the City Engineer, requiring to be prepared
by a licensed engineer and indicates the public infrastructure proposed for construction with the
development. Does the "utility plan" submitted here have any associated public infrastructure
associated with it, or are the utilities pertaining to the operations specific to Verizon Wireless?
We may wish to have this sheet either incorporated into the site plan sheet and eliminate this
sheet, or label the sheet different than "Utility Plan" to not confuse our typical approach with
utility plans.
Comment Number: 5
Comment Originated: 10/16/2012
10/16/2012: Why is the "Utility Plan" sheet using all the same notation of "W" to label
telephone, gas, and chainlink fence? The information is unclear as a result. Please rectify.
Comment Number: 6
Comment Originated: 10/16/2012
10/16/2012: The right-of-way existing for both Vine Drive and Shields Street appears to be
sufficient abutting the property for the roadway classifications of these streets. Additional
dedication for utility easement as well as obligation for roadway improvements to these streets
may be required with future development/redevelopment of the parcel.
Department: Forestry
Contact: Tim Buchanan, 970.221.6361, tbuchananMcgov.com
Topic: General
Department: Current Planning
Contact: Courtney Levingston, 970.416.2283, clevinpston(afcgov.com
Topic: General
Comment Number: 14 Comment Originated: 10/19/2012
10/19/2012: The landscape plan notes need revision. Please address the topics listed under
LUC 3.2.1(1), with special care and notice regarding maintenance and replacement as you
propose no irrigation for the trees. Please add the following notes:
Organic soil amendments shall also be incorporated in accordance with the requirements of
Section 3.8.21 of the City of fort Collins Land Use Code
All plants shall be A -Grade or No. 1 Grade, free of any defects, of normal health, height, leaf
density and spread appropriate to the species as defined by American Association of
Nurserymen standards.
All landscaping shall be installed according to sound horticultural practices in a manner
designed to encourage quick establishment and healthy growth. All landscaping in each phase
shall either be installed or the installation shall be secured with a letter of credit, escrow or
performance bond for one hundred twenty-five (125) percent of the value of the landscaping
prior to the issuance of a building permit.
Trees and vegetation, irrigation systems, fences, walls and other landscape elements shall be
considered as elements of the project in the same manner as parking, building materials and
other site details. The applicant, landowner or successors in interest shall be jointly and
severally responsible for the regular maintenance of all landscaping elements in good
condition. All landscaping shall be maintained free from disease, pests, weeds and litter, and
all landscape structures such as fences and walls shall be repaired and replaced periodically
to maintain a structurally sound condition.
Any landscape element that dies, or is otherwise removed, shall be promptly replaced based
on the requirements of this Section.
Department: Engineering Development Review
Contact: MarcVirata, 970.221.6567, mvirata(&fcaov.com
Topic: General
Comment Number: 1
Comment Originated: 10/16/2012
10/16/2012: The title of the project appears to be FTC Fat Tire based upon the Title Sheefs
"Site Name". If that's the intended title of the project, I don't see this as a concern, though I'd
suggest "Verizon Wireless FTC Fat Tire" might be of benefit to have the name tied to the
wireless telecommunication use. (Note that this comment isn't intended to imply any approval
towards the use of "Fat Tire" in the title, which for all I know may be subject to concerns of
intellectual property of New Belgium Brewing Company.)
Department: Current Planning
Contact: Courtney Levingston, 970.416.2283, clevingston(a.fcgov.com
Topic: General
Comment Number: 6 Comment Originated: 10/15/2012
10/15/2012: On all elevations, please call out that the utility boxes will be painted to match the
building per LUC 3.5.1(1)(3).
Comment Number: 7
Comment Originated: 10/15/2012
10/15/2012: On all elevations, please call out the color and material of the pole "trunk".
Comment Number: 8 Comment Originated: 10/15/2012
10/15/2012: On the elevations, there is reference to a lighting cut sheet please remove and
provide light fixture detail on elevations. Per LUC 3.2.4, must be fully shielded and down
directional. Illustration on elevations should graphically reflect the code requirement.
Comment Number: 9
Comment Originated: 10/15/2012
10/15/2012: On title sheet (T1.0) please change note regarding co -location as follows -
Note: "Per LUC 3.8.13(B), no wireless telecommunication facility of equipment owner or lessee
or employee there of shall act to exclude or attempt to exclude any other wireless provider
from using the same building, structure or location."
Comment Number: 10
Comment Originated: 10/15/2012
10/15/2012: On title sheet (T1.0) please change stories from 1 to "3 - 75 feet"
Comment Number: 11 Comment Originated: 10/15/2012
1011512012: You will be required to resubmit plans with the changes formally and have another
round of review prior to going to hearing.
Comment Number: 12
Comment Originated: 10/16/2012
10/16/2012: The zoning on the title sheet IT 1) is incorrect. It says neighborhood commercial
and it should be limited commercial. Please revise.
Comment Number: 13
Comment Originated: 10/19/2012
10119/2012: The GPS antenna depicted on the elevation is shown to protrude above the
building which does not meet Section 3.8.13(C)(3) of the Land Use Code. Please lower the
GPS antenna so it does not rise above the top of the pre-fab equipment shelter.
City of
Fort Collins
October 19, 2012
Irene Cooke
Closser Consulting for Verizon Wireless
P.O. Box 423
Tabernash, CO 80478
RE: Verizon Wireless at 1052 W. Vine Dr., PDP120025, Round Number 1
Community Development and
Neighborhood services
281 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970.224.6134 - fax
fcgov. com/developmentreview
Please see the following summary of comments from City staff and outside reviewing agencies for your
submittal of the above referenced project. If you have questions about any comments, you may contact the
individual commenter or direct your questions through the Project Planner, Courtney Levingston, at
970416-2283 or clevingston@fcgov.com.
Comment Summary:
Department: Current Planning
Contact: Courtney Levingston, 970.416.2283, clevingstonnafcgov.com
Topic: General
Comment Number: 1
Comment Originated: 10/15/2012
10/15/2012: Please update the site and landscape plan to better clarify the surrounding context,
including clear labeling of Vine & Shields' edge of pavement (both sides), R.O.W. and
property line. Please see redlines.
Comment Number: 2 Comment Originated: 10/15/2012
10/15/2012: Please move the northeastern most Rocky Mountain Juniper to/near either the
southwestern corner or northwestern corner to help provide better screening and transition.
This also allows for potential future co -location ground equipment to the east of the monopine
tower.
Comment Number: 3 Comment Originated: 10/15/2012
10/15/2012: Remove the last note under the Plant Liston the landscape plan concerning
replacement conformance.
Comment Number: 4
Comment Originated: 10/15/2012
10/15/2012: The landscaping plan will need a water budget chart showing total annual water
useage. Please see LUC Section 3.2.1(E)(3)(b)(2).
Comment Number: 5 Comment Originated: 10/15/2012
10/15/2012: The enlarged site plan should be on a sheet separate from the full site plan.