Loading...
HomeMy WebLinkAbout716 MAPLE ST. DUPLEX EXPANSION - PDP - 2-11 - CORRESPONDENCE - (6)0 3. Will this structure have similar materials to the Grant Street Corners project next door? 4. The proposed development project is subject to a Type 2 (Planning and Zoning Board) review and public hearing. The applicant for this development request is required to hold a neighborhood information meeting prior to formal submittal of the proposal. Neighborhood meetings offer an informal way to get feedback from your surrounding neighbors and discover any potential hiccups prior to the formal hearing. Please contact me, at 221-6750, to assist you in setting a date, time, and location. I and possibly other City staff, would be present to facilitate the meeting. S. Please see the Development Review Guide at www.fcgov.com/drg. This online guide features a color coded flowchart with comprehensive, easy to read information on each step in the process. This guide includes links to just about every resource you need during development review. 6. This development proposal will be subject to all applicable standards of the Fort Collins Land Use Code (LUC), including Article 3 General Development Standards. The entire LUC is available for your review on the web at hftp://www.colocode.com/ftcollins/landuse/begin.htm. 7. If this proposal is unable to satisfy any of the requirements set forth in the LUC, a Modification of Standard Request will need to be submitted with your formal development proposal. Please see Section 2.8.2 of the LUC for more information on criteria to apply for a Modification of Standard. 8. Please see the Submittal Requirements and Checklist at: hftp://www.fcgov.com/currentplanning/submiftals.php. 9. The request will be subject to the Development Review Fee Schedule that is available in the Community Development and Neighborhood Services office. The fees are due at the time of submittal of the required documents for the appropriate development review process by City staff and affected outside reviewing agencies. Also, the required Transportation Development Review Fee must be paid at time of submittal. 10. When you are ready to submit your formal plans, please make an appointment with Community Development and Neighborhood Services at (970)221-6750. Page 6 of 6 • rt Collins sidewalks, curbs and gutters, destroyed, damaged or removed due to construction of this project, shall be replaced or restored to City of Fort Collins standards at the Developer's expense prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 4. Please contact Joe Olson and Transportation Planning to schedule a scoping meeting and determine if a traffic study is needed for this project. 5. All public improvements must be designed and built in accordance with the Larimer County Urban Area Street Standards (LCUASS). 6. Section 3.6.2(J)(2) of the Land Use Code requires the paving of the alley with the submitted proposal. However, with the understanding that the property would change from a duplex to two attached single family dwellings, it appears there is no overall increase in the number of units and would make for a potential justification to vary from the requirement on paving the alley as this provision of code allows for an exemption to the alley improvement requirement for carriage houses and habitable accessory buildings (presuming alley paving is not required by another department/entity, such as PFA), and an "equal to or better" argument could perhaps be made that the impact of this proposal is no different than a carriage house. If the applicant wishes to pursue not constructing the abutting alley a modification request to this section of code (as outlined in Section 2.8 of the Land Use Code) should be pursued. 7. Utility plans may be needed for this project. 8. A Development Agreement may be required with this project. 9. A Development Construction Permit (DCP) may need to be obtained prior to starting any work on site. ELECTRIC ENGINEERING Contact: Bruce Vogel, 970-224-6157, bvogel(&fcgov.com 1. Power is available from existing electric facilities in the NW corner of site in the alley. 2. Any costs to modify to our system, including a transformer upgrade, will be the responsibility of the owner. 3. Electric development charges will apply for the additional single family unit. CURRENT PLANNING Contact: Emma McArdle, 970-221-6206; emcardle(&fcgov.com 1. Will any trees being removed during construction? There are several very large trees on the site. Please contact Tim Buchanan before beginning construction regarding the health of these trees. 2. Does the alley connect in the rear? Page 5 of 6 0 rt Collins PARK PLANNING Contact: Craig Foreman, 970-221-6618, cforeman(aDfcgov.com 1. No comments FIRE AUTHORITY Contact: Carie Dann, 970-219-5337, CDANN(a.poudre-fire.org 1. ADDRESS NUMERALS Address numerals shall be visible from the street fronting the property, and posted with a minimum six-inch high numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable). PLEASE NOTE: Contact Tim Varrone with City GIS to discuss addressing options. 2006 International Fire Code 505.1 2. WATER SUPPLY Fire hydrants, where required, must be the type approved by the water district having jurisdiction and the Fire Department. Hydrant spacing and water flow must meet minimum requirements based on type of occupancy. Minimum flow and spacing requirements include: • Commercial and multi -family dwellings 1,500 gpm at 20 psi residual pressure, spaced not further than 300 feet to the building, on 600-foot centers thereafter • Residential within Urban Growth Area, 1,000 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter • Residential outside Urban Growth Area, 500 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter. These requirements may be modified if buildings are equipped with automatic fire sprinkler systems. 2006 International Fire Code 508.1 and Appendix B 3. RESIDENTIAL AUTOMATIC FIRE SPRINKLERS An automatic sprinkler system installed in occupancies in accordance with Section 903.3 shall be provided throughout all buildings with a Group R (Residential) fire area. Residential or quick -response standard sprinkler heads shall be used in dwelling units and guest -room portions of the building. 2006 International Fire Code 903.2.7 ENGINEERING DEVELOPMENT REVIEW Contact: Marc Virata, 970-221-6567, mvirata(a)fcgov.com 1. Larimer County Road Impact Fees and Street Oversizing Fees are due at the time of building permit. Please contact Matt Baker at 224-6108 if you have any questions. 2. Transportation Development Review Fee (TDRF) is due at the time of submittal. For additional information on these fees, please see hftp://www.fcgov.com/engineering/dev-review.php 3. Any damaged curb, gutter and sidewalk existing prior to construction, as well as streets, Page 4 of 6 Ft Collins 1. Existing water mains and sanitary sewers in the area include a 4-inch water main and a 6-inch sewer in Grant, a 10-inch sewer in Maple and a 4-inch water main and an 8-inch sewer in Loomis. 2. The existing water service to the site is a %-inch service connecting to the 4-inch main in Loomis. 3. Separate water and sewer services connecting to City mains will be required for each unit of the duplex. 4. If the number of living units on the site is not changing, no development fees will be due for this project. STORMWATER ENGINEERING Contact: Glen Schlueter, 970-224-6065, aschlueterAftgov.com 1. Drainage requirements and fees are based on new impervious area; therefore, it is important to document the existing impervious area. An exhibit showing the existing and proposed impervious areas is required. In the Old Town drainage basin, a drainage and erosion control report and construction plans are required if there is an increase in impervious area greater than 5000 square feet. These must be prepared by a Professional Engineer registered in Colorado. If there is less than 5000 square feet of new impervious area, a drainage letter should be sufficient to document the existing and proposed drainage patterns, and an erosion control plan is still required. The 5000 square feet of new impervious area is a one time allowance which needs to be documented in a drainage letter or report. 2. If there is an increase in impervious area greater than 5000 square feet, onsite detention is required with a 2 year historic release rate for water quantity. If there is less than 5000 but more than 350 square feet of new impervious area, a site grading plan is required. 3. Water quality treatment is also required as described in the Urban Storm Drainage Criteria Manual, Volume 3 - Best Management Practices (BMPs). Extended detention is the usual method selected for water quality treatment; however, the use of any of the BMPs is encouraged. In this case, bio-retention or disconnection of impervious surfaces may be appropriate. The discharge of the building downspouts into planting beds is another BMP that may be applied for this site. 4. There are no storm sewers in the area; therefore, the outfall for the site is the street curb and gutter or the alley. The path of the increased runoff will need to be documented and cannot have a negative affect on downstream properties. 5. The design of this site must conform to the drainage basin design of the Old Town Master Drainage Plan as well the City's Design Criteria and Construction standards. 6. Stormwater development fees are $6,313/acre ($0.1449/sq.ft.) for new impervious area over 350 sq. ft. In addition, there is a $1,045/acre ($0.024/sq.ft.) review fee. No fee is charged for existing impervious area. These fees are to be paid at the time each building permit is issued. Information on fees can be found on the City's web site at http://www.fcgov.com/utilities/builders-fees.php or by contacting Jean Pakech at 221- 6375. Page 3 of 6 CONCEPTUAL REVIEW STAFF COMMENTS Meeting Date: August 23, 2010 Item: 716 Maple Street PDP Applicant: Steve Whitall Fort Collins, CO Land Use Data: Fortytctfotlins /'�`�� This is a request to expand the existing over and under duplex, converting it to a single residence, build a new attached garage with access off of the alley to the west and also to build an additional residential unit with an attached garage as shown on the site plan. Comments: ZONING Contact: Peter Barnes, 970-416-2355, pbarnes(cDfcclov.com 1. Property is in the NCM zone. A Type 2 review is required since this is an existing duplex and the project involves keeping it as a duplex, but doing an addition (Sec. 4.8(13)(3)(a) of LUC). 2. 924 s.f. of floor area is maximum allowed in the rear 50% of the lot. The lot area of the rear 50% is 2800 s.f., times FAR of .33 = 924 s.f. (Sec. 4.8(D)(5) of LUC). It looks like the proposal consists of a 1500 sf 2-story addition and a portion of a 420 s.f. garage in the rear 50%. This will require a modification. 3. The 2-story addition in the rear appears to have a 5' setback from the side lot lines. At this setback, the maximum wall height allowed is 18' (Sec. 4.8(E)(4)). , 4. Assuming the 2 garages are 2-car garages, then each dwelling unit is limited to a maximum of 3 bedrooms. 5. The lot square footage must be at least twice as large as the floor area (including garages). With a 5600 s.f. lot, this means that max. floor area allowed is 2800 s.f.. If the rear unit is 1500 s.f. and each garage is 420 s.f., then the floor area of the front unit can't exceed 460 s.f.. If it's larger than that, a modification will be required. WATER -WASTEWATER ENGINEERING Contact: Roger Buffington, 970-221-6854, rbuffinatoriMcgov.com Page 2 of 6 of Fort Collins . August 23, 2010 Steve Whitall Fort Collins, CO RE: 716 Maple Street PDP Dear Steve, Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov. com/currentplanning Attached, please see a copy of Staffs comments concerning the request referred to as the 716 Maple Street PDP, which was presented before the Conceptual Review Team on August 23, 2010. The comments offered informally by staff during the Conceptual Review will assist you in preparing the detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you should have any questions regarding these comments or the next steps in the review process, please feel free to contact me at 970-221-6206. Si cerely, —Emma City Planner 14,AA 281 North College Avenue - P.O. Box 580 - Fort Collins, CO 80522 - 0580 — (970) 221-6750 - FAX (970) 224-6134