Loading...
HomeMy WebLinkAbout716 MAPLE ST. DUPLEX EXPANSION - PDP - 2-11 - P&Z PACKET - RECOMMENDATION/REPORT4 716 Maple Street Duple- Expansion, Project Development P,. , - #2-11 March 17, 2011 - Planning and Zoning Board Hearing Page 10 and many of the lots in the area have had lot line adjustments to accommodate wider homes and side yards. This narrow width plus the setbacks makes the option for side -by -side units facing Maple especially difficult and the option for both units to have rear yard space nearly impossible. o The proposed structure's location is also impacted by the remodel of the existing duplex, which is set back 26' from the edge of right-of-way, thus exceeding the required setback by 11'. Though the applicant could have chosen to move the structure up limiting their encroachment into the rear of the lot, this would have minimized the front unit's yard space. The current configuration allows both units to have a functional yard space. 0 RECOMMENDATION: Staff recommends the following: • Denial, based on the Project Development Plan's noncompliance with the applicable standard located in Section 4.8(D)(1) - Density/Intensity of Development, regarding the overall floor area permitted on the site. ; 716 Maple Street Duplex F -)ansion, Project Development Plan #2-11 March 17, 2011 — Planning and Zoning Board Hearing Page 9 • Section 4.8(D)(1) Density/Intensity of Development. Minimum lot area shall be the equivalent of two (2) times the total floor area of the building(s), and • Section 4.8(D)(5) Floor Area Ratio (FAR). Lots are subject to a maximum FAR of thirty-three hundredths (0.33) on the rear fifty (50) percent of the lot. 4. Modification of Standards are requested for Sections 3.6.2(J)(2), 4.8(D)(1) and 4.8(D)(5). Staff makes the following findings for each request: • Section 3.6.2(J)(2) — Design Construction Requirements. o The applicant's request meets the criteria in 2.8.2(H)(4) in that the request diverges from the standard only in a "nominal, inconsequential way when considered from the perspective of the entire development plan," because: o The proposal is not increasing the density on the lot or in the neighborhood, no other section of the alley is paved and the proposed would have similar impact of a carriage house or habitable structure, which are exempted from this requirement. • Section 4.8(D)(1) — Density/Intensity of Development. o The applicant's request does not meet the criteria in 2.8.2(H)(1 — 4). • Section 4.8(D)(5) — Floor Area Ratio (FAR). o 'The applicant's request meets the criteria in 2.8.2(H)(1), in thafthe "plan as submitted will promote the general purpose of the standard for which the modification is requested equally well or better than would a plan which complies with the standard for which a modification is requested;" because: o The intent of this standard is to protect neighboring property owner's privacy in their back yards and maintain adequate back yard space for properties in this zone district. The only property that is impacted by the proposed structure is the one to the east, which has recently been rebuilt by the applicant and is currently vacant. Any future owner, who purchases this structure, will do so with the knowledge of the proposed structure's presence. o The building design is constrained by the lot width of 35'. The minimum lot width for this zone district is 40' for two-family structures 716 Maple Street Duple Expansion, Project Development P. — #2-11 March 17, 2011 — Planning and Zoning Board Hearing Page 8 Please see the attached Applicant's Request Staffs Analysis of the Applicant's Request Staff has evaluated the applicant's request against the criteria provided in Section 2.8.2 of the LUC. This standard addresses a quantitative measure that impacts massing built on lots in an effort to maintain the qualitative aspect of the neighborhood. This is a very eclectic neighborhood which has significantly evolved since its platting in 1895. Very few lots maintain the 35' width that the neighborhood was originally platted as, and over time duplex units and larger multi -family dwellings have been built in the neighborhood on reconfigured lots. The overall lot FAR of the neighborhood ranges from the low 0.1 to 0.7 in at least one larger multi -family dwelling. Though this eclectic neighborhood is difficult to judge compatibility based on a metric, this is the tool the code utilizes at this time. In reviewing this proposal it is staffs determination that the request does not adequately justify the 1,040 square feet of additional floor area proposed above the permitted floor area. The addition of 1,040 square feet is not a nominal and inconsequential increase. Staff recommends denial of the Modification of Standard to Section 4.8(D)(1). FINDINGS OF FACT/CONCLUSIONS - - - After reviewing the 716 Maple Street Duplex Expansion, Project Development Plan, #2- 11, Staff makes the following findings of fact and conclusions: 1. The proposed land use is permitted in the NCM — Neighborhood Conservation, Medium Density Zone District of the Land Use Code. 2. The Project Development Plan complies with all applicable General Development Standards contained in Article 3 of the Land Use Code, with the exception of: • Section 3.6.2(J)(2) — Design Construction Requirements. All public alleys shall be constructed in accordance with the Larimer County Urban Area Street Standards. 3. The Project Development Plan complies with the applicable Land Use and Development Standards contained in Article 4, Division 4.8 of the Land Use Code, with the exception of: • 716 Maple Street Duplex F- -)ansion, Project Development Plan #2-11 March 17, 2011 — Planning and Zoning Board Hearing Page 7 to the public good and meets criteria 2.8.2(H)(1) in that the "plan as submitted will promote the general purpose of the standard for which the modification is requested equally well or better than would a plan which complies with the standard for which a modification is requested." The intent of this standard is to protect neighboring property owner's privacy in their back yards and maintain adequate back yard space for properties in this zone district. The only property that is impacted by the proposed structure is the one to the east, which has recently been rebuilt by the applicant and is currently vacant. Any future owner, who purchases this structure, will do so with the knowledge of the proposed structure's presence. The building design is constrained by the lot width of 35'. The minimum lot width for this zone district is 40' for two-family structures and many of the lots in the area have had lot line adjustments to accommodate wider homes and side yards. This narrow width plus the setbacks makes the option for side -by -side units facing Maple especially difficult and the option for both units to have rear yard space nearly impossible. The proposed structure's location is also impacted by the remodel of the existing duplex, which is set back 26' from the edge of right-of-way, thus exceeding the required setback by 11'. Though the applicant could have chosen to move the structure up limiting their encroachment into the rear of the lot, this would have minimized the front unit's yard space. The current configuration allows both units to have a functional yard space. For these reasons, staff has found that the proposed plan promotes the general purpose of the standard for which the modification is requested equally well than, a plan would that complieswith the standard. Staff recommends approval of the Modification of Standard to Section 4.8(D)(5). 3. Section 4.8(D)(1) — Density/Intensity of Development This standard states: "Minimum lot area shall be the equivalent of two (2) times the total floor area of the building(s), but not less than five thousand (5,000) square feet for a single family dwelling..." The lot size at 716 Maple Street is 5,600 square feet, which would allow a total floor area of 2,800 square feet. The applicant is proposing a total floor area of 3,840 square feet. 716 Maple Street Duplp- Expansion, Project Development F . - #2-11 March 17, 2011 - Planning and Zoning Board Hearing Page 6 This standard requires all alleys be paved, except those public alleys that provide access only for carriage houses and habitable accessory buildings in the NCM, NCL and NCB zone districts. Please see the attached Applicant's Request Staffs Analysis of the Applicant's Request Staff has evaluated the applicant's request against the criteria provided in Section 2.8.2(H) of the LUC. Staff finds that the applicant's request is not detrimental to the public good and meets the criteria of Section 2.8.2(H)(4) in that the request diverges from the standard only in a "nominal, inconsequential way when considered from the perspective of the entire development plan." Staffs analysis is as follows: the proposal is not increasing the density on the lot or in the neighborhood, no other section of the alley is paved and the proposed would have similar impact of a carriage house or habitable structure, which are exempted from this requirement. Therefore, staff finds that the request diverges from the standard only in a "nominal, inconsequential way when considered from the perspective of the entire development plan." Staff recommends approval of the Modification of Standard to Section 3.6.2(J)(2). 2. Section 4.8(D)(5) - Floor Area Ratio (FAR) This section states: "Lots are subject to a maximum FAR of thirty-three hundredths (0.33) on the rear fifty (50) percent of the lot." The total lot size of this site is 5,600 square feet, this would allow 924 square feet of floor area to be located on the real half of the lot. The applicant is proposing approximately 1800 square feet of floor area to be located on the rear of the lot. This exceeds the standard by 862 square feet. Please see the attached Applicant's Request Staffs Analysis of the Applicant's Request Staff has evaluated the applicant's request against the criteria provided in Section 2.8.2 (H) of the LUC. Staff finds that the request is not detrimental 716 Maple Street Duplex oansion, Project Development Plan — #2-11 March 17, 2011 — Planning and Zoning Board Hearing Page 5 housing and have been given this designation in accordance with an adopted subarea plan." This proposal complies with the purpose of the NCM District as it is an addition to an existing duplex structure maintaining the mid — low density of the area. 1. Section 4.8(D) — Land Use Standards The proposal is in compliance with the first part of Section 4.8(D)(1) as the minimum lot size for two family dwellings is 5,000 square feet and this lot is 5,600 square feet. The applicant is requesting two modifications of standards located within this Section, they are discussed in more detail in Subsection 4 of this report. 2. Section 4.8(E) — Dimensional Standards This is an existing lot that is 35' wide. Section 4.8(E)(1) requires that lots be a minimum of 40' for two-family structures, as this is an existing condition since 1895, this was not imposed upon the applicant, consistent with practice. The proposed addition is in compliance with the other standards of this section as the structure is a maximum of 2 stories in height and the setback standards are met by the proposed structure. 3. Section 4.8(F) — Development Standards The proposal complies with the applicable standards of this section as follows: all exterior walls are at'right angles to the side lot lines; the primary entrance is located along the front wall of the building; the second story does not overhang the first story walls; the porch is proposed as a single story; and the roof pitch is within the allowable pitch. 4. Modification of Standards A. Section 2.8.2 Modification Review Procedures As specified in Section 2.8.2 Modification Review Procedures, (H) (Standards), the decision maker may grant a modification of standards only if it finds that the granting of the modification would not be detrimental to the public good and meets one of the criteria set forth in Section 2.8.2(H)(1)-(4). The applicant is proposing three modifications as follows: 1. Section 3.6.2(J)(2) — Design Construction Requirements 716 Maple Street Duple-- Expansion, Project Development F, , — #2-11 March 17, 2011 — Planning and Zoning Board Hearing Page 4 The proposal complies with Section 3.2.2(K)(1) Residential Parking Requirements, in that it provides two off-street parking spaces for each 3 bedroom unit. B. Division 3.3 - Engineering Standards The proposal complies with the design standards, requirements, and specifications for the services as set forth in this section of the LUC. C. Division 3.5 - Building Standards 1. Section 3.5.1 - Building and Project Compatibility The proposed expansion will add a story to the existing structure. The neighborhood is comprised of single -story and two-story dwellings as well as a two-story multi -family building across the street. The proposed structure is of similar height to the dwellings to the east and west. Many of the older housing stock is of smaller stature but over time additions and new homes have been built in the surrounding area making the neighborhood a mix of one and two story structures. 2. Section 3.5.2 — Residential Building Standards The proposal complies with the applicable standards in this section as the garage doors are side loaded, therefore, they are not a dominant feature to the front of the facade. D. Division 3.6 — Transportation and Circulation 1. Section 3.6.2 — Streets, Streetscapes, Alleys and Easements The applicant is requesting a modification to the only applicable standard located within this section. It will be discussed in subsection 4 of this report. 3. ARTICLE 4 -Districts A. Division 4.8 — Neighborhood Conservation Medium Density District Expansions of existing duplexes are permitted in the NCM — Neighborhood Conservation Medium Density Zoning District, subject to a Planning and Zoning Board (Type 2) Review. The NCM District is: "intended to preserve the character of areas that have a predominance of developed single-family and low- to medium -density multi -family 716 Maple Street Duplex r- -)ansion, Project Development Plan - #2-11 March 17, 2011 — Planning and Zoning Board Hearing Page 3 COMMENTS: 1. Background The surrounding zoning and land uses are as follows: N: NCM; existing residential, primarily single-family with some multi -family residential S: NCM; existing single-family and multi -family residential (Comer Church Condos) E: NCM; existing multi -family residential W: NCM; existing single-family and some multi -family residential This property was platted in the West Side Addition as Lot 27 of Block 283 in 1895. Since then many lot line adjustments 2. ARTICLE 3 — General Development Standards The 716 Maple Street Duplex Expansion, PDP complies with of the applicable standards in Article 3 - General Development Standards of the LUC. Of specific note are Division 3.2 — Site Planning and Design Standards; Division 3.3 — Engineering Standards; Division 3.5 Building Standards and Division 3.6 — Transportation and Circulation. Further discussions of these particular standards follow. A. Division 3.2 — Site Planning and Design Standards 1. Section 3.2.1 - Landscaping and Tree; Protection" The proposal complies with Section 3.2.1(D)(1) and (2) in that a "full tree stocking" and a street tree are provided. The plan also complies with Section 3.2.1(E)(2) Landscape Area Treatment in that all area without structure or paving is proposed to have landscaping including foundation plantings and turf grass. The three mature trees existing on the site are proposed to be removed with construction. The applicant is working with the City Forester to make sure the proposed landscaping meets the mitigation requirements of removing the existing trees. This will be verified during final compliance if this application is approved by the Board.. . 2. Section 3.2.2 — Access, Circulation and Parking 716 Maple Street Duplp- Expansion, Project Development F 1- #2-11 March 17, 2011 — Planning and Zoning Board Hearing Page 2 EXECUTIVE SUMMARY: The 716 Maple Street Duplex Expansion, PDP, complies with the applicable requirements of the Land Use Code (LUC), more specifically: • the process located in Division 2.2 - Common Development Review Procedures for Development Applications of ARTICLE 2 - ADMINISTRATION; • the standards located in Division 3.2 - Site Planning and Design Standards; Division 3.3 — Engineering Standards; Division 3.4 — Environmental, Natural and Cultural Standards; Division 3.5 - Building Standards and Division 3.6 Transportation and Circulation of ARTICLE 3 - GENERAL DEVELOPMENT STANDARDS, with the exception of: o The applicant is requesting a Modification of Standard to Section 3.6.2(J)(2) Design Construction Requirements, regarding the paving of the alley along the west boundary of the lot, which staff has determined meets the criteria located in Section 2.8.2 for Modification of Standards; and • the proposed use (expansion of the existing duplex) is permitted, subject to a Planning and Zoning Board Review, and the standards located in Division 4.8 — Neighborhood Conservation, Medium Density District (NCM) of ARTICLE 4 — DISTRICTS, with the exception of: o The applicant is requesting a Modification of Standard to Section 4.8(D)(5) Floor Area Ratio (FAR), which limits the building square footage to be only 33% of the square footage of the rear half of the lot, which staff has determined meets the criteria located in Section 2.8.2 for Modification of Standards. The 716 Maple Street Duplex Expansion, PDP, does not comply with the following applicable standards of the Land Use Code: • The standard located in Section 4.8(D)(1) Density/Intensity of Developments, which requires the minimum overall lot area of the site be equivalent to two times the total floor area of the building area on the site. It is staffs determination that the applicant's justification for this Modification did not meet the criteria located in 2.8.2. Icity of Fort Collins Il �,v1 NO MEETING DATE 3 11-7 I STAFF E. A''}k -dle PLANNING & ZONING BOARD PROJECT: 716 Maple Street Duplex Expansion, Project Development Plan (PDP) — #2-11 APPLICANT: Aubrey Carson Carson Design Studio 413 Cormorant Ct. Fort Collins, CO OWNER: Jim Loftis and Judith Billica 716 Maple Street Fort Collins, CO PROJECT DESCRIPTION: is is a request do expand an existing duplex located at 716 Maple Street. -The property is located within the NCM, Neighborhood Conservation Medium Density zone district. The Land Use Code requires two-family (duplex) structures go through a Type 2 (Planning and Zoning Board) review when any structural additions or alterations are made to an existing duplex structure. The applicant its proposing the conversion of the existing over/under duplex into two side -by -side units separated by two 2-car garages serving each unit. The applicant is also requesting 3 modifications of standards with this proposal. One relates to paving of the hour -glass alley adjacent to the site; the second is for the rear floor area ratio (FAR), which limits the building square footage to be only 33% of the square footage of the rear half of the lot; and the last modification is to the minimum overall lot area of the site, which shall be equivalent to two times the total floor area of the buildings on the site. RECOMMENDATION: Denial, based on plan's noncompliance with Section 4.8(D)(1) regarding the overall floor area permitted on the site. Current Planning 281 N College Av PO Box 580 Fort Collins, CO 80522-0580 fcgov.com/currentplanning 970.221.6750