[2/22/11] Please add a legal description to the Site Plan.
Department: Zoning Issue Contact: Peter Barnes
Topic: Zoning
Number: 1 Created: 2/4/2011
[2/4/11] Need site plan of entire site.
Number: 2 Created: 2/4/2011
[2/4/11] The 60' tall pole requires that the pole be setback 60' from the lot lines. If it's
setback less than 60', then it needs to be designed to collapse rather than topple. Since
there's no overall site plan, I don't know what the setback is. If it's less than 60', then we'll
need plans or documentation explaining that it will collapse.
Be sure and return all of your redlined plans when you re -submit.
If you have any questions regarding these issues or any other issues related to this project,
please feel free to call me at (970) 221-6750.
Sincerely,
Courtney ' py
City Planner
Page 3
v
[2/10/11] Will there be any lighting, security or otherwise, associated with this structure? If
so, the light source shall be high pressure sodium and be fully shielded and down directional
(LUC Section 3.8.13(C)(9)).
Department: Engineering Issue Contact: Andrew Carney
Topic: General
Number: 10 Created: 2/22/2011
[2/22/11] This facility will require some sort of access easement/agreement so that access
to the facility is ensured. Is there an existing access easement for the existing parking lot? If
not a access easement will need to be dedicated via separate document from the public
street through the existing parking lot to the facility. If a easement is not desired, language
included in the lease agreement that ensures access to the facility will also suffice.
Number: 14 Created: 2/22/2011
[2/22/11] Engineering will accept a combination site/utility plan as long as no changes are
proposed to utility connects or any changes in site grading are proposed.
Number: 15 Created: 2/22/2011
[2/22/11] A letter of intent will be required for any off -site easements or access agreements
from the affected property owner.
Number: 16 Created: 2/22/2011
[2/22/11] The entire site will need to be shown on the site and/or utility plan. Currently it is
difficult to tell where on the site the proposed changes are located.
Number: 17 Created: 2/22/2011
[2/22/11] As noted in Comment #2, the setback of the pole must be equal to or larger than
its height. Under no circumstance may a pole fall into public ROW. Please either move the
pole so that it meets the setback criteria or demonstrate and document that the pole will
crumple rather than topple.
Department: Light & Power Issue Contact: Alan Rutz
Topic: Light and Power
Number: 11 Created: 2/22/2011
[2/22/11] A new single phase transformer 120/240 volt will be installed for this project.
Coordinate transformer location with Light and Power. Submit C-1 form with load
requirements.
Number: 12 Created: 2/22/2011
Electric development charges will apply.
Number: 13 Created: 2/22/2011
Electric meter must be accessible by Light and Power.
Department: Technical Services Issue Contact: Jeff County
Topic: General
Number: 19 Created: 2/22/2011
[2/22/11 ] Is this only a 2 sheet set of plans? If not, we need to see all plans prior to mylars.
Topic: Site Plan
Number: 18
Created: 2/22/2011
Page 2
M
STAFF PROJECT REVIEW
City of Fort Collins
Steve Warner - swarner@atecs.biz Date: 2/23/2011
ATECS, LLC - T-Mobile
7901 E. Lowry Blvd.
Denver, CO 80230
Staff has reviewed your submittal for T-Mobile Wireless Telecommunication Facility at 3519
Richmond Dr. PDP - Type I, and we offer the following comments:
ISSUES:
Department: Current Planning Issue Contact: Courtney Rippy
Topic: Fire
Number: 9 Created: 2/22/2011
[2122/11] BATTERY STORAGE
The project is required to meet applicable standards set for in Section 608 — Stationary
Storage Battery Systems of the 2006 International Fire Code.
Topic: General
Number: 3 Created: 2/10/2011
[2/10/11] Documentation of your effort to co -locate on existing facilities in the vicinity is
required. This documentation should include: all existing facilities in your desired increased
coverage area, why that co -location is not feasible and if other carrier was contacted, who
you spoke with and contact information (LUC Section 3.8.13(B)).
Number: 7 Created: 2/10/2011
[2/10/11] Please provide photo -simulations prior to the public hearing. Photo -simulations
should accurately represent the proposed plans in terms of scale and proposed
landscaping. (LUC Section 3.5.1(G)). Please label this documentation as "Exhibit F.
Number: 8 Created: 2/10/2011
[2/10/11 ] A color sample (color chip) of the proposed pain color for the monopole will be
needed prior to hearing. Color shades shall be used to facilitate blending into the
surroundings. The shades shall draw from the range of color shades that already exist on
the block (LUC Section 3.5.1 (F)).
Topic: Landscaping
Number: 4 Created: 2/10/2011
[2/10/11] Provide separate landscape.plans detailing existing and proposed improvements.
With proposed improvements, documentation of proposed species is needed. Please
reference Fort Collins Approved Plan List (LUC Section 3.8.13(C)(4)).
Number: 5 Created: 2/10/2011
[2/10/11] The proposed facility has frontage on Horsetooth and will need additional
landscaping. Street trees shall be planted in accordance with the policies of the City
Forester, Tim Buchanan (LUC 3.8.13.(C)(4)). His e-mail is tuchanan@fcgov.com.
Topic: Lighting
Number: 6
Created: 2/10/2011
Page 1