Loading...
HomeMy WebLinkAboutFAIRVIEW SHOPPING CENTER, FILING FOUR - FDP - FDP120007 - CORRESPONDENCE - REVISIONS (3)Department: Water -Wastewater Engineering Contact: Roger Buffington, 970.221.6854, rbuffington(a)fcgov.com Topic: Construction Drawings Comment Number: 2 Comment Originated: 07/30/2012 07/30/2012: Is the existing sewer service 4" or 6"? If 4", it is strongly suggested that the service be replaced with 6" to avoid potential maintenance/plugging problems at the connection between the existing 4" and the proposed 6" coming out of the building. The sewer service is maintained by the property owner from the building to the sewer main in the street including the connection at the main. Department: Zoning Contact: Noah Beals, 970.416.2313, nbeals(afcgov.com Topic: General Comment Number: 1 Comment Originated: 07/26/2012 07/26/2012: On Site Plan remove existing Building Envelope Comment Number: 2 Comment Originated: 07/26/2012 07/2612012: Why is the existing tree in the median south of the Accessibity spaces not protected? It Department: PFA Contact: Ron Gonzales, 970.416-2864, rponzalest7a.aoudre-fire.org Topic: General Comment Number: 5. 07131/2012: Department: Stormwater Engineering Contact: Wes Lamarque, 970.416.2418, wlamargue(a)fcgov.com Topic: Erosion Control Comment Number: 1 Comment Originated: 07/31/2012 Comment Originated: 07/30/2012 07/30/2012: The site disturbs more than 10,000 sq-ft so an Erosion Control Report and Plans need to be produced. Topic: General Comment Number: 2 Comment Originated: 07/30/2012 07/30/2012: Please provide all details and soil media specifications for the rain garden. Department: Technical Services Contact: Jeff County, 970.221-6588, icountvna fcgov.com Topic: Building Elevations Comment Number: 3 07/3012012: Please add "Fairview Shopping Center Filing Four" to all sheets. Topic: Lighting Plan Comment Number: 4 07/30/2012: Please add "Fairview Shopping Center Filing Four" to all sheets. Comment Number: 5 07/30/2012: Please add a north arrow to sheet E0.1. Topic: Plat Comment Number: 1 07/30/2012: The Subdivision boundary closes. Comment Number: 2 Comment Originated: 07/30/2012 Comment Originated: 07/30/2012 Comment Originated: 07/30/2012 Comment Originated: 07/30/2012 Comment Originated: 07/30/2012 07/3012012: Please change the symbol for "found #4 rebar". It does not match the symbol shown at the northwest corner of the boundary. Department: Water -Wastewater Engineering Contact: Roger Buffington, 970.221-6854, rbuffington(a)fcgov.com Topic: Construction Drawings Comment Number: 1 Comment Originated: 07/30/2012 07/30/2012: Move the curb stop and meter pit north into the landscaped area. 00 Department: Forestry Contact: Courtney Levingston, 970.416.2283, clevingston(a.fcgov.com . Topic: Landscape Plans Comment Number: 1 Comment Originated: 07/31/2012 07/31/2012: Please add the following notes to the Landscape Plan: "The soil in all landscape areas, shall be thoroughly loosened to a depth of not less than eight (8) inches and soil amendment shall be thoroughly incorporated into the soil of all landscape areas to a depth of at least six (6) inches by tilling, discing or other suitable method, at a rate of at least three (3) cubic yards of soil amendment per one thousand (1,000) square feet of landscape area." Please include these landscape notes: A permit must be obtained from the City forester before any trees or shrubs as noted on this plan are planted, pruned or removed on the public right-of-way. This includes zones between the sidewalk and curb, medians and other city property. This permit shall approve the location and species to be planted. Failure to obtain this permit may result in replacing or relocating trees and a hold on certificate of occupancy. The developer shall contact the City Forester to inspect all street tree plantings at the completion of the development. All trees need to have been installed and protected as shown on the landscape plan. Failure to obtain approval by the City Forester for trees shall result in a hold on certificate of occupancy. Comment Number: 2 Comment Originated: 07/31/2012 Department: PFA Contact: Ron Gonzales, 970.416.2864, ronzales( poudre-fire.org Topic: General Comment Number: 1. Comment Originated: 07/31/2012 07/31/2012: The address is required to be visible from the street fronting the property. Comment Number: 2. Comment Originated: 07/31/2012 07/31/2012: The unit numbers shall be visible from the fire lane, be a minimum 4 inches in width with a 1 inch stroke posted on a contrasting background. Comment Number: 3. Comment Originated: 07131/2012 07/3112012: This project will be fire sprinklered. The standard water supply is a 6 inch line. A 4 inch can be used, if the hydraulic calculations support the smaller line. Calculations must be submitted to verify the 4 inch line. Comment Number: 4. Comment Originated: 07/31/2012 07/31/2012: A 3 story building requires a 30 foot wide fire lane that does not exceed 150 feet in length; or if it is longer, a turn -around is required at the end of the fire lane. * Department: Engineering Development Review Contact: Marc Virata, 970.221.6567, mvirata@fcgov.com Topic: Construction Drawings Comment Number: 1 Comment Originated: 07/31/2012 07/31/2012: The floodplain exhibit on C4.1 of the construction plans incorrectly labels an attached 8' sidewalk along Elizabeth Street. Please label the general use of 10' wide sidewalks on the plan sets. Comment Number: 2 Comment Originated: 07/31/2012 07/31/2012: Please add the standard street patch note regarding limits of patch shown on the construction drawings. Comment Number: 5 Comment Originated: 07/31/2012 07/31/2012: Construction plan details should be added, to include a construction detail for the drive approaches, access ramps, sidewalk, etc. Comment Number: 6 Comment Originated: 07/31/2012 07/31/2012: Please ensure that with the final approved construction plan set that a copy of the plat is included in the set for reference. Topic: General Comment Number: 3 Comment Originated: 07/31/2012 07/31/2012: The two drive approaches should have more definitive indication on the plans (especially the construction set) of how they intend to be modified to allow for suitable crossing of the sidewalk. The plans (except for one note on the site plan specific to the eastern driveway) do not appear to have any indication of the drive approaches being rebuilt in order for the new sidewalk to not tie into driveways with both concrete and asphalt across this interface. The concrete scoring indicative of the sidewalk crossing through the driveway should be shown on the drawings. Comment Number: 4 Comment Originated: 07/31/2012 07/31/2012: The sidewalk across the eastern driveway should be designed to anticipate tying into a 12' wide sidewalk to the east proposed with redevelopment of that property. The plans should show a widening from 10' to 12' in order to make the tie in. A note on the plans can be placed acknowledging a deviation of the plan could be considered in the event that redevelopment of the property to the east is no longer apparent. . Comment Number: 7 Comment Originated: 07/31/2012 07/31/2012: Please change the title on all the'drawings provided by Aller-Lingle-Massey to Fairview Shopping Center Filing Four to coordinate with the other drawings. Topic: Plat Comment Number: 8 Comment Originated: 07/31/2012 07/31/2012: Carried over from the PDP, we'll need to see the private utility, access, and shared parking easement recorded prior to approval of the final plan/plat. Department: Forestry Contact: Courtney Levingston, 970.416.2283, clevingston(a fcgov.com Topic: Landscape Plans A r, City of Fort Collins August 01, 2012 Dave Derbes Brinkman Partners, LLC 3003 E Harmony Rd, Suite 300 Fort Collins, CO 80528 RE: 1409 W Elizabeth St. - Fairview Shopping Center Filing Four, FDP120007, Round Number 2 Community Development and Neighborhood Services 281 North College Avenue PO Box 580 Fort Collins, CO 80522 970.221.6750 970.224.6134 - fax fcgov.com/deve/0pmentrevlew Please see the following summary of comments from City staff and outside reviewing agencies for your submittal of the above referenced project. If you have questions about any comments, you may contact the individual commenter or direct your questions through the Project Planner, Courtney Levingston, at 970416-2283 or clevingston@fcgov.com. Comment Summary: Department: Current Planning Contact: Courtney Levingston, 970.416.2283, clevingston(Mcgov.com Topic: General Comment Number: 1 Comment Originated: 07/31/2012 07/31/2012: 06/12/2012: please provide detail on the retaining wall. Comment Number: 3 Comment Originated: 07/31/2012 07/31/2012: There are two trees on the south end of the site that we have questions about regarding protection. Please see redlines. Topic: Landscape Plans Comment Number: 1 Comment Originated: 07/31/2012 07/31/2012: Please modify note #5 on the landscape plans. Comment Number: 2 Comment Originated: 07/31/2012 07/31/2012: Please remove interior floor plan of the building from the landscape and tree mitigation plans. Comment Number: 3 Comment Originated: 07/31/2012 07/31/2012: Is the mulch rock or wood? Please note on plans. Wood is preferable. Topic: Site Plan Comment Number: 1 Comment Originated: 07/31/2012 07/31/2012: Please turn off all landscaping and countour lines on the site plan.