HomeMy WebLinkAboutWATER'S EDGE @ RICHARD'S LAKE - MOD. OF STAND. - 58-86I - CORRESPONDENCE - (24)13. This development request will be subject to the Development Review Fee
Schedule that is available in the Current Planning Department office. The
fees are due at the time of submittal of the required documents for the
appropriate development review process by City staff and affected outside
reviewing agencies.
14. The City's Current Planning Department will accept the development
requests and will coordinate the development review process. The required
submittal packages will be submitted to this department and distributed
accordingly to other City departments and outside reviewing agencies
involved in development review.
15. This development proposal is subject to the requirements as set forth in the
City's LUC, specifically Articles 2. Administration (Development Review
Procedures), Article 3. General Development Standards, Division 4.1 - Urban
Estate Zoning District, and Division 4.4 - Low Density Mixed -Use
Neighborhood Zoning District. Copies of these Articles and Divisions are
available in the Current Planning Department or on the City of Fort Collins
website @ www.fc o� v.com. Go to Departments, then the Current Planning
Department, to find the City's LUC.
16. Regarding a neighborhood meeting, it is not yet determined whether this
residential project will be subject to an administrative (Type 1) review or a
Planning and Zoning Board (Type 2) review. A neighborhood meeting must (or
should) be held prior to formal submittal of the project, depending on the
type of review it is subject to. Be it a Type 1 or a Type 2 review, the
proposed 394 new residential dwelling units on the 105 acres represent a
significant change on this undeveloped property and it will be better to
notify offected property owners and present the proposed plan to them at
an "informal" neighborhood meeting rather than have them become involved
for the first time at an eventual administrative or Planning and Zoning Board
public hearing. Per Section 2.2.6(D) of the LUC, the notification area would
be a minimum radius of 1,000' (in all directions from the property
boundaries) for the total of 394 dwelling units. Please contact Steve Olt of
the Current Planning Department, at 221-6341, to assist you in setting a
date, time, and location for the meeting.
10
• Colorado Butterfly Plant
C. A wetland delineation may be required.
d. Natural Habitat and Features Buffer Zone standards may apply.
• 100' from the lake.
e. Fort Collins native plants and grasses and revegetation will be
required in buffer zones.
f. Please consider designing bio-swales to provide water quality.
g. A Fugitive Dust Permit may be required. Please contact the Lorimer
County Environmental Health Department for their requirements.
Doug can be reached at 224-6143 if you have questions about these
comments.
11. Michael Chavez of the Poudre Fire Authority offered the following
comments:
a. Fire lanes will be required in the multi -family portion of the
development.
b. Some of the addressing for portions of the development may be
problematic.
C. Fire flows of 1,000 gallons per minute will be required for the single-
family residential. Fire flows of 1,500 gallons per minute will be
required for the multi -family residential.
Please contact Michael, at 416-2869, if you have questions about these
comments.
12. It may be beneficial to consider larger lots along the north side of this
property adjacent to Serramonte Highlands, providing a potentially more
compatible density transition between developments. This could be done
within the context of a development proposal satisfying the density
requirements (5 - 8 dwelling units per acre) set forth in the LMN District.
9
e. Light & Power will not have any problems with service to many of the
single-family lots; however, there may be issues associated with
services to the patio homes and A units.
f. Overall, this project looks to be very do -able.
g. A utility coordination should be held, preferably before formal
submittal of any plans, for this new development proposal.
Please contact Bruce, at 224-6157, if you have questions about these
comments.
9. Kurt Ravenschlag of the Transportation Planning Department offered the
following comments:
a. There must be a 6' wide detached sidewalk, with a 10' wide parkway,
along Turnberry Road.
b. There must be 4.5' wide sidewalks, with 6' wide parkways, along the
internalstreets.
C. Bicycle parking, satisfying the requirements set forth in Section
3.2.2(C)(4)of the LUC, must be provided.
Please contact Kurt, at 416-2040, if you have questions about these
comments.
10. Doug Moore of the Natural Resources Department offered the following
comments:
a. Section 3.4.1 Natural Habitats and Features of the LUC will apply to
this development proposal.
b. An ecological characterization study will be required. This study
needs to provide additional information related to sensitive or
specially valued plant and animal species (both State and Federal) and
animal habitat features, such as:
• Showy Prairie Gentian
• Prebles Meadow Jumping Mouse
• Ute Ladies' Tress Orchid
s
treatment. There has been a change in the rainfall requirements
since the approval of the previous filing of the Richard's Lake
development (from before the flood of 1997). Therefore, the volume
of detention required may need to be revised (upward). The
additional volume may be accommodated in the freeboard of the
existing pond, which is 2 times the "old" rainfall volume. If a release
rate can be negotiated with the No. 8 Ditch then the present rainfall
requirements must be used to size the revised pond. The contact for
the No. 8 Ditch is the Windsor Reservoir and Canal Company. Bill
Johnson, Superintendent, is the contact at 481-7671.
d. Any lots that drain into Richard's Lake will need to get the
permission of the Water Supply & Storage Company; and, they will
need to sign the construction plans. The contact person is Jim McFall,
Superintendent, at 482-3433.
e. Backyard swales within private lots are not allowed. Any swale must
be in a separate tract that is owned and maintained by the developer
or a Home Owner's Association.
Please contact Glen, at 224-6065, if you have questions about these
comments.
8. Bruce Vogel of the Light & Power Department offered the following
comments:
a. There is existing City power in Brightwater Drive to Parkside Drive.
Services can be fed from this street north into the undeveloped
property.
b. Coordinate all electric transformer and meter locations with Light &
Power.
C. The standard electric development charges will apply to this
development request. Please check with Light & Power for
information on how the charges are assessed on any new development.
d. There is an existing overhead electric line along the west side of this
property that must be undergrounded when new development occurs
on the property.
Please contact Mike and/or Webb, at 493-2044, if you have questions about
these comments.
5. Please contact someone at the Boxelder Sanitation District, at 498-0604,
for information about their requirements.
6. Craig Foreman of the Parks Planning Department offered the following
comments:
a. The proposed residential development on this property will be subject to
the City's parkland fees. Parkland fees, for both neighborhood and
community parks, will apply to each residential dwelling unit and will be
collected at the time of issuance of building permits. The fees are based
on the square footage of each dwelling unit.
b. The City owns the neighborhood parkland site in Richard's Lake. At this
time the park is scheduled for design and construction possibly in 2011.
c. Extra dirt is needed for the park.
d. There is a future community park site identified somewhere near
Anheuser-Busch.
Please contact Craig, at 221-6618, if you have questions about these
comments.
7. Glen Schlueter of the Stormwater Utility offered the following comments:
a. The site is located in the Boxelder/Cooper Slough Drainage Basin,
where there presently are no new development fee. This may change
as City Council is considering a new city-wide drainage fee instead of
the present fee that is based on a specific drainage basin.
b. The standard drainage and erosion control report and construction
plans are required and they must be prepared by a professional
engineer registered in the State of Colorado. Compliance with the
previous drainage study will need to be verified, especially the
amount of imperviousness used in that study.
C. On -site detention is required with a 2-year historic rate for water
quantity and extended detention is required for water ug ality
C-I
P. This development will be responsible for the ultimate design along
Turnberry Road. The Lind Property development, to the east, did the
1,000' off -site design that this development can tie into.
q. Interim improvements must be done now, with money in lieu of
construction.
r. The proposed street into the multi -family residential area needs to
be looked at.
S. Is this development plan meeting the Street System Block size
requirements set forth in Section 4.4(E)(1)(a) of the LUC?
Please contact Susan, at 221-6750 or 221-6605, if you have questions about
these comments.
3. Roger Buffington of the Water/Wastewater Department indicated that
this proposed residential development is located in the service areas for the
East Larimer County (ELCO) Water District and the Boxelder Sanitation
District. Please contact them directly for their requirements for water and
sanitary sewer services to this site.
4. Mike Scheid of ELCO offered the following comments:
a. ELCO can serve this proposed new development. They have an
existing 12" water main in Brightwater Drive.
b. This development cannot provide irrigation water with Water Supply
& Storage (WS&5) water. Raw water from another source will be
required. Please talk to Webb Jones of ELCO about the raw water
requirements for this proposed new development.
C. There is a strip of land, containing an existing 20" water line, along
the north line of this property that belongs to ELCO.
d. There could be water service conflicts in some of the tight (small lot)
areas of the development. A utility coordination meeting should be
held.
e. Please contact ELCO about their tap fee schedule.
5
would occur after the required public hearing for this development
proposal and just before the subdivision plat is filed.
g. No more than 4 single-family homes can be accessed from any one
private drive.
h. IMPORTANT: This new development proposal may have Adequate
Public Facilities (APF) issuesassociated with it. Section 3.7.3 of the
LUC sets forth the APF management system. The TIS for this new
development will help determine APF requirements and
responsibilities. Eric Bracke, the City's Traffic Engineer, will
determine if there is any capacity left on / at the affected streets
and intersections.
The streets will need to align with streets across Turnberry Ro ad, to
the east. If no median exists across the street then the proposed
median in Morningstar Way will need to be eliminated or pulled back.
Medians at the developer's option are not maintained by the City.
Irrigation and drainage must be provided to the median.
j. This development may be responsible for a repay or repays for
previously constructed improvements to Turnberry Road and
Brightwater Drive.
k. It is not certain that both Morningstar Way and Brightwater Drive
intersections with Turnberry Road can be full movement in the
future.
I. Development on this property will be responsible for dedicating all
necessary street ROW and easements associated with the
development.
M. A utility coordination should be held, preferably before formal
submittal of any plans, for this new development proposal.
n. A Development Agreement and a Development Construction Permit
will be required for development on this property.
o. A subdivision plat is required to create the intended residential lots
in this development. The plat will also dedicate the necessary street
ROW and easements.
4
C. The street tree requirement for all development is set forth in
Section 3.2.1(D)(2) of the LUC. Please review all of Section 3.2.1 for
the overall landscaping requirements.
d. The parking requirements associated with this development are set
forth in Section 3.2.2 of the LUC.
Please contact Jenny, at 416-2313, if you have questions about these
comments.
2. Susan Joy of the Engineering Department offered the following comments:
a. The standard utility plan submittal requirements will apply to the
development request.
b. Street oversizing fees will apply to this development request. The
fees are based on the vehicle trip generation for the proposed land
use(s) on the development plan. Please contact Matt Baker of
Engineering, at 224-6108, for detailed information on the fees. The
fees will be collected at the time of issuance of building permits.
C. A Transportation Impact Study (TIS), addressing all modes of
transportation, will be required with your development submittal.
Please contact Eric Bracke of the Traffic Operations Department,
at 224-6062, and Kurt Ravenschlag of the Transportation Planning
Department, at 416-2040, to determine what information will be
needed in the TIS pertaining to Level of Service (LOS) for vehicle,
pedestrian, bicycle, and transit modes of transportation.
d. The Lorimer County Road Impact Fees will apply to all development
on this property.
e. This development will be subject to the requirements set forth in the
Lorimer County Urban Area Street Standards (LUCASS) as they
pertain to public improvements.
f. Existing street rights -of -way (ROW) and easements associated with
the previous development plan and subdivision plat must be vacated as
part of this new development request if they differ from proposed
new ROW and easements. This requires City Council action and it
3
• The maximum density of any phase in a multiple -phase
development plan shall be 12 dwelling units per gross acre, and the
maximum density of any portion of a phase containing a grouping
of 2 or more multi -family structures shall be 12 dwelling units per
gross acre.
• Affordable housing projects (pursuant to an overall development
plan or project development plan) containing 10 acres or less may
attain a maximum density, taken as a whole, of 12 dwelling units
per gross acre.
• There is a requirement for a Neighborhood Center component in a
development plan in the LMN District, as set forth in Section
4.4(D)(3) of the Land Use Code (LUC).
• There is a requirement for a Small Neighborhood Park component
(either public or private) in a development plan in the LMN
District, as set forth in Section 4.4(D)(7) of the LUC. The future
City park May satisfy this requirement.
• There is a requirement for a Mix of Housing types in a
development plan in the LMN District, as set forth in Section
4.4(D)(2) of the LUC.
b. A portion of the property is in the UE - Urban Estate Zoning
District.
• Single-family detached dwellings and single-family attached
dwellings are permitted in this District, subject to an
administrative (Type 1) review and public hearing.
• Residential cluster developments are permitted in the UE
District, subject to a Planning and Zoning Board (Type 2) review
and public hearing. Criteria for Site Design for Residential
Cluster Development is set forth in Section 4.1(E)(2) of the LUC.
This section sets forth a requirement for at least 50% open
space in the cluster plan.
• Overall average density in the UE District shall not exceed 2
dwelling units per net acre.
4
MEETING DATE: August 22, 2005
ITEM: Single -Family and Multi -Family Residential (394
Dwelling Units), Recreation Center, and Future City
Neighborhood Park on 105 Acres
APPLICANT: Vignette Studios
c/o Don Tiller
144 North Mason Street, Suite 2
Fort Collins, CO. 80524
LAND USE DATA:
Request for 394 total residential dwelling units (single-family and multi -family), a
recreation center, and a future City neighborhood park on 105 acres located at the
northwest corner of Brightwater Drive and Turnberry Road. The property is in the
LMN - Low Density Mixed -Use Neighborhood and UE - Urban Estate Zoning
Districts in the City of Fort Collins.
COMMENTS:
1. Jenny Nuckols of the Zoning Department offered the following comment:
a. The majority of the property is in the LMN - Low Density Mixed -Use
Neighborhood Zoning District. Single-family detached dwellings and
multi -family dwellings (8 or less units/building) are permitted in this
District, subject to an administrative (Type 1) review and public
hearing.
• The LMN District has a density range requirement of a minimum
of 5 dwelling units/net acre to a maximum of 8 dwelling
units/gross acre on the property, taken as a whole.