Topic: Construction Drawings
Comment Number: 3 Comment Originated. 04/03/2012
04/03/2012: Is there a conflict between the sidewalk and the fire hydrant?
The revised sidewalk design allows the existing fire hydrant to remain in its current location.
Comment Number: 4 Comment Originated: 04/03/2012
04/0312012: See redlined plans for other comments.
See revised Utility Plans (to submitted during Final Plan phase) for corrections.
Topic: Landscape Plans
Comment Number: 1
Comment Originated: 04/03/2012
04/0312012: Show water and sewer lines on the landscape plan and adjust landscaping to
provide required separation distances. Include the sewer near the south property line.
'Nater and sewer lines have been added to landscape plan.
Department: Zoning
Contact: Noah Beals, 970.416.2313, nbeals(t1jfcgov.com
Topic: General
Comment Number: 1
Comment Originated: 03/20/2012
03/20/2012: With 6 studio, 6 one bedroom, 6 two bedroom, and 9 three bedroom units this
project is required 47 off street parking spaces. There are 41 spaces on the site, then six
addifional spaces are required. This means that six of the the spaces on the lot to the east
need to be signed for residential use only. The location of these signs should be identified on
the site plan. A sign has been called out on the south side of the existing Wendy's restaurant. This
will be reserved parking for the multi -family building to meet to required parking count.
Comment Number: 2 Comment Originated: 03/20/2012
03/2012012: The trash enclosure is not meeting the standards in the Land Use Code section
3.2 5. This section requires a walk-in access without having to open the main service gate.
Also it is unclear if the enclosure is built on a cement concrete pad, site plan needs to indicate
this. The trash enclosure detail has been revised. Please see LS501
Comment Number: 3
Comment Originated: 03/20/2012
03/20/2012: The elevation and site plan lack any locations of the necessary mechanical/utility
equipment. Please indicate these items on both elevations and site plan and notes of how
All mechanical equipment is on the roof and screened by parapets. The electric and gas
they are to be screened and/or palntedmeters stacks will be painted to match the adjacent building material where applicable
and will be shown on the Final Plan subm' di Comment Number: 5 mment Originated: 03/20/2012
0312012012: Site Plan should be cleaned up, remove the exisfing conditions of the subject
property.
Acknowledge,.
Department: Technical Services
Contact: Jeff County, 970-221-6588, Icountypfcgov com
Topic: Plat
Comment Number: 6
03/29/2012. There is a minor line over text issue.
See revised Plat for corrections.
Comment Number: 7
Comment Originated: 03/29/2012
Comment Originated: 03/29/2012
03/2912012: Please reference how West Elizabeth Street was dedicated.
See revised Plat.
Comment Number: 8 Comment Originated: 03/29/2012
03129/2012: Please provide monument records for all public land comers shown on the Plat.
Copies of the requested monument records have been provided electronically.
Comment Number: 9 Comment Originated: 03/29/2012
03/2912012: See redlines regarding the Basis Of Bearings statement.
See revised Plat for corrections
Comment Number: 10 Comment Originated: 03/2912012
0312912012: Please add a scale to the scale bar
See revised Plat.
Topic: Site Plan
Comment Number: 11 Comment Originated: 03/2912012
03/29/2012: Please provide a legend on the Topographic Survey sheet.
Comment Number: 12 Comment Originated: 03/29/2012
03/29/2012: There are line over text issues on the Topographic Survey sheet 8 sheet LS101
Line over text issues on LS101 have been revised
Department: Transportation Planning
Contact: Emma McArdle, 970.221.6197, emcardle(cDfcgov.com
Topic: General
Comment Number: 1 Comment Originated: 03/29/2012
03/2912012: For your information this corridor was identified as an enhanced travel corridor in
the City's Transportation Master Plan. It is anticipated that someday the Elizabeth comdor will
provide a strong transit connection between the Mason Bus Rapid Transit Enhanced Travel
Corridor, CSU, the Campus West area and the CSU Research Campus. Special transit routing
could be offered to Hughes Stadium for special events
Acknowledged
Comment Number: 2 Comment Originated: 0312912012
03/29/2012. A bus stop is currently located near this site east of the intersection of West
Elizabeth Street and City Park Avenue. No bus stop improvements shall be required of this
proposal at this time.
Scknowledged
Department: Water -Wastewater Engineering
Contact: Roger Buffington, 970-221-6854, rbufftngton(a)fcgov.com
Topic: Construction Drawings
Comment Number: 2
Comment Originated: 04/03/2012
04/0312012: Add note to coordinate with Water Utilities (970416-2165) on the abandonment of
the 1' water service.
See revised Utility Plans (to be submitted during Final Plan phase) for the requested note
Department: Stormwater Engineering
Contact: Wes Lamarque, 970-416-2418, wlamarquelcDfcgov.com
Topic: General
Comment Number: 1 Comment Originated. 04/04/2012
0410412012: Stormwater is ready for a hearing. Comments may apply during final compliance
Acr_nnwiedged
Department: Technical Services
Contact: Jeff County, 970-221-6588, icounty(cDfcgov.com
Topic: Building Elevations
Comment Number: 14
03/29/2012: No comments.
Topic: Construction Drawings
Comment Number: 17
Comment Originated: 03/29/2012
Comment Originated 03/29/2012
03129/2012: Please add descriptions to the benchmarkson sheet CO.0.
See revised Utility Plans (to be submitted during Final Plan phase) for corrections.
Comment Number: 18 Comment Originated: 03/29/2012
03129/2012: The bearing in the Basis Of Bearings statement on sheet CO doesn't match the
Subdivision Plat.
See revised Utility Plans (to be submitted during Final Plan phase) for corrections.
Comment Number: 19 Comment Originated 03/29/2012
03129/2012: There are line over text & text over text issues on sheets C 1.0, C4.0 & C4.1.
See revised Utddy Plans (tu be submitted during Final Plan phase) for corrections.
Topic: Landscape Plans
Comment Number: 13 Comment Originated: 03/29/2012
03129/2012: Sheet G001 is incorrectly labelled as a site plan.
Sheet GOO has been revised.
Topic: Lighting Plan
Comment Number: 15 Comment Originated: 03/29/2012
03/2912012: There are line over text issues on sheet EO 1
Sheet E0.1 has been revisec.
Comment Number: 16 Comment Originated: 03/29/2012
03129/2012: Please add a north arrow to sheet E01
Sheet E0.1 has been revised.
Topic: Plat
Comment Number: 1
Comment Originated:
03/29/2012
0312912012: The Subdivision Plat boundary doses.
Acknowledged
Comment Number: 2
Comment Originated:
03/29/2012
03/29/2012: Please increase the size of the text in the vicinity map.
See revised Plat for corrections.
Comment Number: 3
Comment Originated:
03/29/2012
03/2912012: Please rearrange the "line" labels along Elizabeth Street.
See revised Plal for corrections.
Comment Number: 4
Comment Originated:
03/29/2012
03/2912012: Please see the note regarding establishing the boundary.
See revised Plat for corrections.
Comment Number: 5
Comment Originated.
03129/2012
03/2912012: Please correct the surveyors name at the center of section 15
See revised Plat for corrections.
Department: Light And Power
Contact: Doug Martine, 970-224-6152, dmartine(�fcoov.com
Topic: General
Comment Number: 1 Comment Originated: 03/20/2012
03/20/2012, The "Private access and shared parking easement" on the south side of the site
will also need to be a utility easement.
See revised Plat.
Comment Number: 2 Comment Originated: 03/2012012
03/2012012: The builder will need to complete an electric commercial service (C-1) form, and
coordinate power locations and requirements with Light & Power Engineering (221-6700). Will
also need a 1-line diagram of the electric service. Electric utility charges as well as electric
sritem modification charges will apply.
cknowled edn the project for building unit.
Comment Numar: 3 8omment Originated: 33120/2012
03/2012012: Relocation of the power line serving the Wendy's transformer will require Light 8
Power to trench through the asphalt of a portion of the Wendy's site. Asphalt repairs will be the
responsibility of the developer. Relocation of this power line will need to be completed prior
to start of construction of the new building.
Ackno led ed
Comment Alum%er. 4 Comment Originated: 03/20/2012
03/20/2012: Each dwelling must be individually metered, and the meters must be outdoors,
accessable to utility personnel 24-7. The electric meters (owner provided) will need to be 5
terminal type with the 5th terminal in the 9 O'clock position.
Acknowledged. This will be provided along with the proposed building's construction documents.
Department: Outside Agencies
Contact: Don Kappernan, ,
Topic: General
Comment Number: 1
03/30/2012 Comcast is currently located on the west side of the building
Department: Park Planning
Contact: Craig Foreman, 970-221-6618, cforemanofcgov_com
Topic: General
Comment Number: 1
03/16/2012 No comments
Department: PFA
Contact: Ron Gonzales, 970-221-6635, rgonzales(�poudre-ftre.oro
Topic: General
Comment Number: 1.
Comment Originated: 03/30/2012
Comment Originated: 03116/2012
Comment Originated: 03/27/2012
03127/2012: A communication evaluation is required for this 3-story edifice to validate fire
department communications. If not, a bi-directional antenna is required to enhance PFA
communications within and out of the building.
Acknowledged.
Department: Stormwater Engineering
Department: Forestry
Contact: Tim Buchanan, 970-221-6361, tbuchananofcgov.com
Topic: Landscape Plans
Comment Number: 1 Comment Originated: 04/03/2012
04/03/2012.
The following Forestry comments are offered
A preliminary walk occurred with the City Forester to review existing trees and impact from the
proposed construction.
1. Provide in the next submittal a table listing all of the existing significant trees. Each significant
tree should be numbered and include information on species, size, condition, and intent to
either remove, transplant or protect. Also provide in the table the number of mitigation trees
required for any significant tree proposed to be removed and for trees to be protected.
Required mitigation trees should be upsized based on tree type
Shade Tree 3 inch caliper
Ornamental Tree 2.5 inch caliper
Evergreen Tree 8 feet height
A table has been added to LP101 outlining existing trees and mitigation requirements. In addition all mitigation trees will follow land
use code requirements.
2. Please provide a statement of why existing significant trees would need to be removed on
the current proposed plan. Existing significant trees need to be retained to the extent
reasonably feasible. Where it is not feasible to protect and retain then they need to be
replaced with upsized mitigation trees.
Because of the proposed building footprint, minimum density requirements for project feasibility, and existing site constraints and conditions
some of the existing significant trees will require removal and mitigation. All mitigation trees will follow land use code requirements.
3. Required mitigation trees should be kept on site if possible and can be used to meet
landscape requirements. Offsite mitigation needs to occur within one quarter mile.
All mitigation trees will he kept on site.
4. The proposed sidewalk running north and south on the west side of the east honeylocust in
front of the building appears to be only a few feet from the trunk of the tree. Pursue a design for
vthe walk that minimizes excavation into the root system, and or shifts the walk to the west further
away from the tree.
The sidewalk west of the Honeylocust on the north side of the building has been revised to angle northwest away from the existing tree
as much as possible.
Department: Internal Services
Contact: Lisa Schoenfeld, , Ischoenfeldidfcaov.com
Topic: General
Comment Number: 1 Comment Originated: 03/30/2012
03/3012012: Adopted by City Council last March, the new City of Fort Collins green building
codes went into effective January 1. 2012. These can be found at.
http./iwww.fcgov.conVbuilding/codes.php. Please call Lisa Schoenfeld at 416-2640 with any
Vquestions.
The developer and the project architect have already had a pre -submittal meeting with Russ Hovland on 519/12 to discuss the Green
Codes and 2009 IBC requirements.
Department: Light And Power
Contact: Doug Martine, 970-224-6152. dmartine(a),fcgov com
Department: Engineering Development Review
Contact: Marc Virata, 970-221-6567, mvirataiciffcgov.com
Topic: Plat
Comment Number: 4 Comment Originated 04/04/2012
04/04/2012. Just curious as to why the subdivision plat creates lot lines that results in equal lot
sizes but do not correspond to any "as -built" condition? The site, landscape and construction
plans show this line but does not label it, while also showing a more prominent (thicker and
dashed) line without indicating what this line is intended to represent (a "PDP" boundary?)
There needs to be coordination/venliication on the intent of the lines shown on the drewirt�s.
The rcit line corresponds to a previous property split, and matches current County parcels and a dressing
Comment Number. 5 Comment Originated: 04/04/2012
04/0412012: The private access and shared parking easement indicated on the plat would
need to be recorded prior to the recordation of the plat.
, ,'knnwledyled
Contact: Sheri Langenberger, 970-221-6573, slangenberger0fcgov.com
Topic: Fees
Comment Number: 1
Comment Originated: 03/20/2012
03120/2012: The Transportation Development Review Fee for the PDP that was paid was not
enough. PDP total should be $5,653.08 Amount paid was $5,505. $148.08 additional is owed
for PDP. The acreage amount on form was less than and did not match the size of the parcel
on the plat.
im C,,.•h,oer has already paid for the remaining balance of the Transportation Development Review Fee on 5/18/12.
Department: Environmental Planning
Contact: Lindsay Ex, 970-224-6143, lexafegoil
Topic: General
Comment Number: 1
Comment Originated: 04/03/2012
04/03/2012: Environmental Planning has no issues with these plans. Kudos to the landscape
architects for their plant selections and emphasis on native species.
Acknowledged.
Department: Forestry
Contact: Tim Buchanan, 970-221-6361, tbuchananofcgov.com
Topic: Landscape Plans
Department: Engineering Development Review
Contact: Marc Virata, 970-221-6567, mviratad),,fcgov.com
Topic: General
Comment Number: 3 Comment Originated: 04/04/2012
04/04/2012 The proposal of an 8 foot attached sidewalk is of question. The City's view is that
(per the Conceptual Review comments) an attached sidewalk matching the Campus West
Redevelopment is the ideal specification for an attached sidewalk. This sidewalk dimension for
the Campus West Redevelopment is 12 feet and ideally this proposal should match this width
(and is also the proposed width of the redevelopment property next door). The site visit with
Northern and Brinkman identified some potential restriction points to meeting the ideal width:
the tree in front of the Wendy's and a light pole along with a fire hydrant. We were realizing that
the tree in front of Wendy's would likely need to narrow from an ideal width in order to not
impact the tree but thought that the 12 foot width could be likely achieved along the rest of the
corridor The light pole and fire hydrant, while being existing restncbon points, we did not
necessarily conclude that these appurtenances could stay as is. With the drawing submitted it
shows that with the 8 fool attached sidewalk, the light pole would be fully in the sidewalk and
the fire hydrant is partially in the sidewalk as well. The City would conclude that these
appurtenances should be moved as they're awkwardly situated in the 8 foot attached sidewalk,
which would have the design then look towards more of the ideal sidewalk width. (Doug Martine
with Light and Power noted that the cost to move the pole so irs not within/abutting the sidewalk
is no different to achieve 2 foot separation from the proposed 8 foot sidewalk to vs. a more
ideal sidewalk width with further separation.) We would need to evaluate any proposal that does
not incorporate the 12' attached sidewalk through a variance request in coordination with
Planning. See response to Current Planning Site Plan Comment Number: 3, above. Sidewalk on north side of
properly has been revised to reflect changes that were discussed with City staff.
Comment Number: 6 Comment Originated: 04/04/2012
04/04/2012: The proposed 9 feet of additional right-of-way wouldn't be needed in its entirety.
The amount of right-of-way needed would only need to coincide with the back of sidewalk
ultimately decided to and agreed upon to be built per ID#3 (with the exception that Light and
Power and Water/Wastewater would need additional easement or right-of-way for relocated
appurtenances). Adhering to the 9 feet of additional right-of-way would appear to be
problematic in that part of the Werdy's patio would fall within this additional right-of-way.
Seer ed tat S of additional right-of-way is being dedicated to coincide with the new ba or wal
Commerr� umger: i� (omman��ngma�ed: 04/0412012
04/0412012: Both drive approaches would need to have additional concrete added in order for
the sidewalk to lead to a concrete section, not partial concrete/asphalt. The access ramp
leading to a curb for the eastern exit driveway is awkward as well with the curb needing to be
pulled back.
Concrete has been added at both drive locations, each extending to the back of the pedestrian crossing
Comment Number: 10 Comment Originted: 04/04/2012
04/04/2012
Topic: Plat
Comment Number: 2 Comment Originated: 04/0412012
04/0412012: The plat language has been updated. Please provide the more updated certificate
of dedication, repair and maintenance language
See revised Plat for corrected language.
Department: Current Planning
Contact: Courtney Levingston, 970416.2283, cievingston(rDfcgov.com
Topic: Site Plan
Comment Number: 1 Comment Originated: 04/03/2012
0410312012: Per LUC 3.2.2 (C)(2), please include a bike parking detail on the plans.
Additionally, please indicate the number of bike parking spaces that are being provided in your
site data table.
Bike rack detail has been added to LS501. Bike parking count has been added to LS101.
Comment Number: 2 Comment Originated: 04/03/2012
04/03/2012: Please put a note on the site plan regarding shared parking arrangement_
Shared parking arrangement note has been added to LS101.
Comment Number: 3 Comment Originated: 04/03/2012
04/03/2012: The development at 1401 W. Elizabeth is currently in the development review
process and proposing a 12' sidewalk. As proposed, the firehydrant is abutting the sidewalk
and needs to be 2' from the walk and the existing metal light pole in located within the
sidewalk. Both the hydrant and the lightpole should be moved back and the sidewalk width
increased. While the full 12' walk may not be an option, we are suggesting that 10' may be
Jmore appropriate in this case. A variance request is still required for a 10' walk.
See revised Site Plan. A formal variance request will be submitted to Engmn nng Development Review following the
PDP public hearing to document the final sidewalk design.
Department: Engineering Development Review
Contact: Marc Virata, 970-221-6567, mviratal�fcgov.com
Topic: Construction Drawings
Comment Number: 7
Comment Originated: 04/04/2012
04104/2012. Please indicate north flowline information and roadway lane striping on Elizabeth
Street to ascertain how the approximate area of the proposed patch situates with the "as-buir
condition of Elizabeth Street.
TMs be hown n the Utility Plans to be submitted during the Final Plan phase.
Commend �lumer Comment Orginated: 04/04/2012
04/04/2012: The construction drawings show a 10' utility easement, which per the plat is
intended to be vacated and should perhaps be removed from the labelling tl intended to be
vacated.
See revised Plat A 9.5' wide portion of the original UE not being dedicated as new right-of-way will remain.
Topic: General
Vic+ Ida
25/ f
� cc�
f'Jo
F-It '
City of
Fort Collins
April 06, 2012
Dave Derbies
Brinkman Partners, LLC
3003 E Harmony Rd, Suite 300
Fort Collins, CO 80528
Community Development and
Neighborhood Services
261 North College Avenue
PO Box 580
Fort Collins, CO 80522
970.221.6750
970 224.6134 - fax
fcgov comedeve/opmenaeview
v
v'
RE: 1409 W Elizabeth Street Student Apartments, PDP120009, Round Number 1 ° \
Please see the following summary of comments from City staff and outside reviewing agencies for your
submittal of the above referenced project. If you have questions about any comments, you may contact the
individual commenter or direct your questions through the Project Planner, Courtney Levingston, at
970416-2283 or clevingston@fcgov oom.
Comment Summary:
Department: Current Planning
Contact: Courtney Levingston, 970416-2283, ctevingston(cDfcl7ov.com
Topic: Building Elevations
Comment Number: 2
Comment Originated: 04/02/2012
04/02/2012: We will need a colored rendering of the elevations prior to hearing to assist in
assessin compatibility outlined in Section 3.5.1 of the land Use Code.
Coloredevabons and 3D mews have been provided and are attached with these comment responses.
Topic: General
Comment Number: 1
Comment Originated: 04/03/2012
04/03/2012: We will want to ensure that the development area on site plan, the development
agreement and the plat all match up and Clearly defined on each. Please label the PDP
development area on the site plan and remove the dashed line down the middle.
The PDP development area has been identified on sheet LS101.
Comment Number: 2 Comment Originated: 04/03/2012
04/0412012: Staff is wondering if bollards are the best option to contain C.B.&Potts spill over
parking. Would signage be a more appropriate first step and see if that addresses any
potential issues? While there is nothing that I am aware of in the Code that precludes bollards
(no PFA issues), Staff suggests reconsidering the bollard approach.
Acknowledged
Co
mmeM Number: 3 Comment Originated: 04/04/2012
04104/2012: Floodplain does not allow for basement storage units in this instance.
Acknowledged.
Topic: Site Plan