HomeMy WebLinkAboutSPRING CREEK FARMS NORTH - AMENDED ODP - ODP110001 - SUBMITTAL DOCUMENTS - ROUND 1 -VIGNETTE
6 f fl d l 0 5
\;uc4!
10. When you are ready to submit your formal plans, please make an appointment with
Community Development and Neighborhood Services at (970)221-6750.
\o1cd
Thank you for your time spent in reviewing these plans. If you have any further
questions, please feel free to contact any of the team members.
Yours Truly
Terence C. Hoaglund
RLA, ASLA, LEED AP
PO Box 1889
Fort Collins, CO 80524 (970) 472-9125
www.vignettestuclios.com
VIGNETTE
3. LUC 4.5(E)(1)(a) requires the local street system to be interconnected in a manner that
results in blocks of developed land bounded by connecting streets no greater than 12 acres
in size. Making a note on the CDP may help clairify how you plan on addressing this
standard.
This has been addressed iviih a not on the plans. Specific street networks will not be
lnaotirn until detailed PDP plans are prepared.
4. The proposed development project is subject to a Type 2 (Planning and Zoning Board) review
and public hearing. The applicant for this development request is required to hold a
neighborhood information meeting prior to formal submittal of the proposal. Neighborhood
meetings offer an informal way to get feedback from your surrounding neighbors and discover
any potential hiccups prior to the formal hearing. Please contact me, at 221-6750, to assist
you in setting a date, time, and location. I and possibly other City staff, would be present to
facilitate the meeting.
Noted, the neighborhood meeting has been held.
5. Please seethe Development Review Guide at www.fcaov.com/dra. This online guide features
a color coded flowchart with comprehensive, easy to read information on each step in the
process. This guide includes links to just about every resource you need during development
review.
Noted
6. This development proposal will be subject to all applicable standards of the Fort Collins Land
Use Code (LUC), including Article 3 General Development Standards. The entire LUC is
available for your review on the web athhttp://www.colocode.com/ftcollins/landuse/begn.htm.
-oted
If this proposal is unable to satisfy any of the requirements set forth in the LUC, a
Modification of Standard Request will need to be submitted with your formal development
proposal. Please see Section 2.8.2 of the LUC for more information on criteria to apply fora
Modification of Standard.
None are proposed at this time.
8. Please see the Submittal Requirements and Checklist at:httD7//www.fcaov.com/
developmentreview/applications. oho.
Voted
9. The request will be subject to the Development Review Fee Schedule that is available in the
Community Development and Neighborhood Services office. The fees are due at the time of
submittal of the required documents for the appropriate development review process by City
staff and affected outside reviewing agencies. Also, the required Transportation Development
Review Fee must be paid at time of submittal.
PO Box 1889
Fort Collins, CO 80524 (970) 472-9125
www.vignettestudios.com
VIGNETTTos
s l u d
street is longer than 660 feet. All structures beyond the 660-foot limit shall be fire sprinklered
if a second point of access cannot be provided. FCLUC 3.6.2(B)(C); 3.6.6(I); 2006
International Fire Code 503.2.5, Appendix D103.3 and D103.4
5. DEAD-END FIRE APPARATUS ACCESS ROADS Dead-end fire apparatus access roads in
excess of 150 feet in length shall be provided with an approved area for turning around fire
apparatus. 2006 International Fire Code 503.2.5 and Appendix D103.3 and D103A
6. TURNING RADII The required turning radii of a fire apparatus access road shall be a
minimum of 25 feet inside and 50 feet outside 2006 International Fire Code 503.2.4 and
Appendix D103.3
7. ADDRESS NUMERALS Address numerals shall be visible from the street fronting the
property, and posted with a minimum six-inch high numerals on a contrasting background.
(Bronze numerals on brown brick are not acceptable). If the numerals are mounted on a side
of the building other than the side off of which it is addressed, the street name is required to
be posted along with the numerals. 2006 International Fire Code 505.1
Noted.- These wil/ be speciJicullp addressed iriih each PDP
ENVIRONMENTAL PLANNING
Contact: Lindsay Ex, 970-224-6143, lex@fcgov.com
1. No comments on the amended ODP.
ENGINEERING DEVELOPMENT REVIEW
Contact: Susan Joy, 970-221-6581, sjoy@fcgov.com
1. No comments on the amended ODP. This project is responsible for all development
requirements and fees at the time of PDP submittal.
ELECTRIC ENGINEERING
Contact: Janet McTague, 970-224-6154, jmctague@fcgov.com
1. Power is available on Charles Bockman and on Nancy Gray. We'll need to coordinate
transformer and meter locations. Normal development charges will apply
Contact: Courtney Rippy, 970-416-2283, crioov@fcgov.com
CURRENT PLANNING
1. It appears that the police station is located where the plan shows the neighborhood park
location. Where will the new location of the park? Please reference section LUC section 4.5
(D)(6)
The park 10eatiM7 is now shown within Parcel A. The submitted ODP has been updated to
reflect cun•ent hnih condilions.
2. Why the need for all allowable uses instead of just adding multifamily? Putting all allowable
could be contentious with the neighborhood.
7 ho givcs he landowner the most,flexibi/i(r.
PO Box 1889
Fort Collins, CO 80524 (970) 472-9125
www.vignette5tudios.com
VIGNETTE\
tr„dr�,s
PARK PLANNING
Contact: Craig Foreman, 970-221-6618, cforeman@fcgov.com
1. No comments
FIRE AUTHORITY
Contact: Carle Dann, 970-219-5337, CDANN@poudre-fire.ora
1. RESIDENTIAL AUTOMATIC FIRE SPRINKLERS An automatic sprinkler system installed in
occupancies in accordance with Section 903.3 shall be provided throughout all buildings with
a Group R (Residential) fire area. Residential or quick -response standard sprinkler heads
shall be used in dwelling units and guest -room portions of the building. 2006 International
Fire Code 903.2.7
2. REQUIRED ACCESS Fire access roads (fire lanes) shall be provided for every facility,
building or portion of a building hereafter constructed or moved into or within the PFA's
jurisdiction when any portion of the facility or any portion of an exterior wall of the first story of
the building is located more than 150 feet from fire apparatus access as measured by an
approved route around the exterior of the building or facility. This fire lane shall be visible by
painting and signage, and maintained unobstructed at all times. A fire lane plan shall be
submitted for approval prior to installation. In addition to the design criteria already contained
in relevant standards and policies, any new fire lane must meet the following general
requirements:
• Be designed as a flat, hard, all-weather driving surface (asphalt or concrete) capable of
supporting fire apparatus weights. Compacted road base shall be used only for temporary
fire lanes or at construction sites.
• Have appropriate maintenance agreements that are legally binding and enforceable.
• Be designated on the plat as an Emergency Access Easement.
• Maintain the required minimum width of 20 feet throughout the length of the fire lane (26
feet on at least one long side of the building when the structure is three or more stories in
height).
• If the building is equipped throughout with an approved automatic fire -sprinkler system, the
fire code official is authorized to increase the dimension of 150 feet. 2006 International Fire
Code 503.1.1, 503.2.3, 503.3, 503.4 and Appendix D
3. WATER SUPPLY Fire hydrants, where required, must be the type approved by the water
district having jurisdiction and the Fire Department. Hydrant spacing and water flow must
meet minimum requirements based on type of occupancy. Minimum flow and spacing
requirements include:
Commercial and multi -family dwellings 1,500 gpm at 20 psi residual pressure, spaced not
further than 300 feet to the building, on 600-foot centers thereafter
Residential within Urban Growth Area, 1,000 gpm at 20 psi residual pressure, spaced not
further than 400 feet to the building, on 800-foot centers thereafter
Residential outside Urban Growth Area, 500 gpm at 20 psi residual pressure, spaced not
further than 400 feet to the building, on 800-foot centers thereafter.
These requirements may be modified if buildings are equipped with automatic fire sprinkler
systems.
2006 International Fire Code 508.1 and Appendix B
4. CUL-DE-SAC A dead-end street cannot exceed 660 feet in length. The turn -around at the end
of the street must have an outside turning radius of 50 feet or more, and an inside turning
radius of 25 feet. Short fire lanes are permitted to facilitate a second point of access when the
PO Box 1889
Fort Collins, CO 80524 (970) 472-9125
www.vignettestudios.com
VIGNETTE
t u d l u
March 9, 2011
Courtney Rippey
City Planner
Community Planning and Development
281 North College Avenue
Fort Collins Colorado 80524
Dear Courtney
The following is the applicant's response to the Spring Creek Farms CDP Conceptual
Review Comments dated February 7, 2011. Please find attached copies of the ODP
plans for your review.
Comments:
ZONING
Contact: Peter Barnes, 970-416-2355, abarnes@fcgov.com
1. No comment
WATER -WASTEWATER ENGINEERING
Contact: Roger Buffington, 970-221-6854, rbuffington@fcgov.com
1. The overall utility plan submitted with the CDP appears to be adequate. Detailed comments
will be provided with the next PDP submittal.
\„I L" /
STORMWATER ENGINEERING
Contact: Glen Schlueter, 970-224-6065, gschlueter@fggov.com
1. A drainage letter documenting the general drainage plan is required with an CDP. John
Gooch has already submitted a draft of the ODP drainage letter and has discussed our
comments. He plans to submit the revised letter at this conceptual review meeting.
2. The conceptual review for future PDPs will include any detailed drainage design
requirements. In general, the design of this site must conform to the drainage basin design of
the Foothills Drainage Master Drainage Plan as well the City's Design Criteria and
Construction standards.
3. The Stormwater development fee (PIF) is $6,313.00/acre ($0.1449/sq.ft.) for new impervious
area over 350 sq.-ft. and there is a $1,045.00/acre ($0.024/sq.ft.) review fee. No fee is
charged for existing impervious area. These fees are to be paid at the time each building
permit is issued. Information on fees can be found on the City's web site at http://
www.fcgov.com/utilities/business/builders-and-developers/plant-i nvestment-development-fees
or contact Jean Pakech at 221- 6375 for questions on fees.
A'oted a revised drainage letter is included with this submittal
PO Box 1889
Fort Collins, CO 80524 (970) 472-9125
www.vignettestudios com