11. Matt Fater of the Stormwater Utility offered the following comments:
a. This site is located within the McClellands/Mail Creek Basin, which has a
fee of $3,717 per acre. Development of the property is subject to the
runoff coefficient reduction.
b. The standard drainage and erosion control reports and plans are required
and they must be prepared by an engineer registered in the State of
Colorado.
C. This site has a 0.5 c.f.s./acre release rate requirement, so on -site
detention is required.
d. Drainage of the railroad right-of-way cannot be blocked or added to.
e. Any necessary off -site grading easements must be part of the "first"
submittal for this development.
Please contact Matt, at 221-6589, if you have questions about these comments.
12. To reiterate, the City will be changing from the performance -based, flexible
zoning ordinance known as the Land Development Guidance System to a new,
more conventional zoning ordinance called the Land Use Code, probably by the
end of March, 1997. Final draft copies of the LUC (dated 2/14/97) are available
to the public at the downtown Kinko's store for about $12.00. Based on the
current Draft Zoning Map, this property will see a change from HB-- Highway
Business to C - Commercial Zoning. The development review process will not
initially change dramatically, although changes to the process are being
considered. It will be important to stay in contact with the City Current Planning
Department so that, at the time you are ready to submit a development
proposal, you are fully aware of the review process and fees that the project will
be subject to.
Enclosed with these comments are relevant sections of the latest draft of the
LUC for your review. Don't hesitate to call Steve Olt, at 221-6341, if you have
any questions about the City's requirements.
8. Roger Buffington of the Water/Wastewater Department offered the following
comments:
a. There are existing 8" water and 8" sanitary sewer mains in Mason Street
that can be tapped into to serve this development. Any services into this
property that may exist must be used by the development or be
abandoned back to the main.
b. A sand and oil interceptor will be required for this use.
C. Plant investment fees and water rights will apply to this development and
the fees will be collected at the time of issuance of building permits.
d. The City's adopted water conservation standards, for irrigation systems
and landscaping, will apply to the additions. A copy of the ordinance and
requirements for the standards is available in the Water Department and
in the Current Planning Department.
Please contact Roger, at 221-6681, if you have questions about these
comments.
9. Sharon Getz of the Building Inspection Department offered the following
comments:
a. The building, being over 5,000 square feet in size, must be
compartmentalized into areas of less than that square footage or be
equipped with an automatic fire sprinkler system.
b. If a body shop is included there is a hazardous material classification for
that part of the building. If the body shop exceeds 3,000 square feet in
size then it must be sprinkled.
C. This request must comply with the new Non -Residential Energy Code.
Please contact Sharon, at 221-6760, if you have questions about these
comments.
10. Susie Gordon of the Natural Resources Department offered the following
comments:
a. The trash enclosure should be designed and sized to accommodate
recycling.
b. A fugitive dust plan may be required for this development. The Larimer
County Health Department would be the reviewing agency for this plan,
so please contact them directly.
C. Street oversizing fees of $19,443 per acre (for commercial development)
will apply and the fees will be collected at the time of issuance of building
permits.
d. It is important to show all access points onto Mason Street from the
properties on the east side to help determine where accesses for this
development could/should occur.
Please contact Mike, at 221-6750, if you have questions about these comments.
5. Fred Jones of the Transportation Department offered the following comments:
a. The proposed south access for this development should align with
Kensington Drive or be separated by at least 200'. The actual allowable
locations of -access points will be dependent on traffic operations in the
area, determined by the traffic impact analysis.
b. A Traffic Impact Analysis is required with this development proposal. The
analysis should address pedestrian connectivity and vehicle level of
service at the intersections in the area.
C. The City will be implementing new Transportation Impact Study
Guidelines after March 28, 1997 that will deal with the master street plan,
street standards, vehicle levels of service, transit development plan,
bicycle program plan, and a pedestrian plan. Please contact Eric Bracke,
at 221-6062, for additional information about the guidelines.
d. The required sidewalk along the frontage of Mason Street must be
designed to the City's minor arterial street standard.
Please contact Fred, at 221-6820, if you have questions about these comments.
6. Kathleen Reavis, the City's Transportation Planner dealing with
bicycle/pedestrian facilities, stated that more direct access from the sidewalk to
the building (minimizing the pedestrian and vehicular interface) must be
provided. Also, bicycle parking should be provided. This proposal will be subject
to the Site Planning and Design Standards (for all development) that are
described in Article 3 of the new LUC that could be adopted by City Council on
March 18, 1997 and go into effect on March 28th. There is a section in this
article on access, circulation, and parking.
7. Gayl-ene Rossiter of Transfort stated that they do not have City public transit at
this location yet; however, there are future plans to serve this area and they want
good pedestrian access provided to the site for when public transit is available.
b. The amount of parking shown on the concept plan is of concern. What is
this facility going to be used for: new car display, auto storage, etc? The
parking seems excessive for express lube, servicing, and maintenance.
C. The handicapped parking requirement is 1 space for every 25 spaces,
depending on the use of the site. If a portion of the parking is to be long
term or display then the amount can be decreased.
Please contact Gary, at 221-6760, if you have questions about these comments.
2. Bruce Vogel of the Light & Power Department offered the following comments:
a. The normal electric development charges will apply and will be assessed
on this project.
b. There is an existing (at grade) oval vault at the northeast corner of this
property.
C. The new transformer location should be coordinated with the Light &
Power Department.
Please contact Bruce, at 221-6700, if you have questions about these
comments.
3. Roger Frasco of the Poudre Fire Authority offered the following comments:
a. Mason Street is classified as a minor arterial street. A fire hydrant must be
provided on the west side of the street near the entrance to the site
closest to the building.
b. A Hazardous Materials Impact Analysis may be necessary for this
development. Please contact Ron Gonzales of the fire authority to discuss
the possible need for the analysis.
Roger and Ron can be reached at 221-6570 if you have questions about these
comments.
4. Mike Herzig of the Engineering Department offered the following comments:
a. Mason Street is classified as a minor arterial street. A 15' wide utility
easement is required along the frontage of the street, in addition to and
outside of the street right-of-way.
b. The City is encouraging shared access along Mason Street, to minimize
the number of access points along this arterial. An attempt should be
made to provide shared access with the properties to the north and south.
CONCEPTUAL REVIEW STAFF CO-IMENTS
City of Fort Collins
MEETING DATE: February 24, 1997
ITEM: Pedersen's Express Lube & Service Center
APPLICANT: Dana Lockwood
Dana W. Lockwood Architects
420 South Howes Street
Fort Collins, CO. 80521
LAND USE DATA:
Request for a 1-story, 15,000 square foot building on 3.51 acres located on the west
side of Mason Street just north of Kensington Drive. This facility would provide a new
location for administrative, express lube, and service capabilities for the existing
Pedersen Toyota Automobile Dealership, which are presently being done in a building
at the southwest corner of JFK Parkway and Troutman Parkway. The property is in the
FIB - Highway Business Zoning District.
COMMENTS:
1. , Gary Lopez of the Zoning Department offered the following comments:
a. The property is currently in the FIB - Highway Business Zoning District;
however, City Council will probably be adopting a new Land Use Code
Lj UC) on March 18, 1997 that would rezone the City and place this
property in the C - Commercial Zoning District. If adopted at second
reading, the new LUC would become effective on March 28th.
Offices; Retail stores with vehicle servicing; and, Minor vehicle
repair, servicing, and maintenance establishments are permitted
uses in the C District, subject to an administrative (Type 1) review
under the new LUC.
Major vehicle repair, servicing, and maintenance establishments;
Vehicle and boat sales establishments with outdoor storage; and,
Parking lots and parking garages (as principal use) are permitted
uses in the C District, subject to review by the Planning and Zoning
Board (Type II) under the new LUC.
CUMMUNITI PLANNING AND ENVIRONMENTAL SERVICES 281 .N Collt-a- ,',�,. ;'.; : 6:..
PLANING DFP4RTNIE\T
Commu y Planning and Environmental •vices
Current Planning
Citv of Fort Collins
February 27, 1997
Dana Lockwood
Dana W. Lockwood Architects
420 South Howes Street
Fort Collins, CO. 80521
Dear Dana,
For your information, attached is a copy of the Staffs comments concerning the request
for Pedersen's Express Lube & Service Center, which was presented before the
Conceptual Review Team on February 24, 1997.
This is a request for a 1-story, 15,000 square foot building on 3.51 acres located on the
west side of Mason Street just north of Kensington Drive. This facility would provide a
new location for administrative, express lube, and service capabilities for the existing
Pedersen Toyota Automobile Dealership, which are presently being done in a building
at the southwest corner of JFK Parkway and Troutman Parkway. The property is in the
HB - Highway Business Zoning District.
The comments are offered informally by Staff to assist you in preparing the detailed
components of the project application. Modifications and additions to these comments
may be made at the time of formal review of this project.
If you should have any questions regarding these comments or the next steps in the.
review process, please feel free to call me at 221-6750.
Sin rely,
4jv Olt
Project Planner
xc: Stormwater Utility/Glen Schlueter
Streets/Eric Bracke
File
LLB n,,,. „n . ,,.. i�... _ --