HomeMy WebLinkAboutPEDERSEN AUTO PLAZA - PDP/FDP - 26-97 - CORRESPONDENCE - UTILITY PLANS (8)REVISION COMMENT SHEET DATE: January 14, 1998 DEPT: Water/Wastewater PROJECT: #26-97 Pedersen Auto Plaza, Type II (LUC) PDP/FC All comments must be received by Steve Olt no later than the staff review meeting: Wednesday, January 28, 1998 -No connection may be made to a water service from the water main to a point 5' downstream of the meter pit. Define this distance on landscape and site plan for irrigation point of connection. -Provide the required landscape/utility separations on the landscape plans. -A 1" water service is shown on the overall utility plan and a V/2" service is shown on the site and landscape plan. Coordinate the landscape design with the civil design. -Provide stationing for sanitary sewer service measured from downstream manhole. -Include standard sanitary sewer service detail on detail sheet. See site, landscape and utility plans for other comments. loo Date: CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS X Plat X Site _ Drainage Report _Other X Utility X Redline Utility X Landscape