'DATE: July 21, 2004 TO: Comcast
PROJECT: #30-95C Poudre Valley Plaza P.U.D. Pad G,
The Promenade - Major Amendment - Type I
(LUC)
All comments must be received by Steve Olt no later than the staff
review meeting: _4
Fc
F
August 11, 2004 cGn®r, " O /GF�
Note - PLEAsE identify your redlines for future reference
Comcast Cable will need the builder to supply a 2-inch conduit from the pedestal out side
the building to the interior that meets our standards with a demarcation point on each
floor.
0
Name (please print)
CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS
flat mite _Drainage Report _Other
_Utility _Redline Utility �Landscape
Utilities
electric • stormwater • wastewater • water
City of Fort Collins Water Conservation Standards for Landscapes
COMMENT SHEET
Project Name: P,R,Ak a �:�r!¢� n u? C f u n
Date of Review:
Reviewed By: Laurie D'Audney, Water Conservation Specialist, 221-6877
I have reviewed this landscape plan and it does not comply with the standards marked below.
Landscape Plan Requirements
❑ 1. The landscape plan shall contain a general note calling for the review and approval by the City
of Fort Collins of any required landscape irrigation system, prior to the issuance of a Building
Permit.
4�12. The landscape plan shall include the total area (in square feet) for each landscape category.
Landscape categories are distinguished by their water requirements and intended maintenance
level. Examples of possible categories include, but are not limited to, high water turfgrass, low
water turfgrass, low water planting beds, moderate water planting beds, and non -plant areas
(paved areas, etc.).
❑ 3. Mulches shall be used for planting beds. The mulch can be either organic or inorganic, and
shall be applied to a minimum depth of 3 inches. In order to prevent large expanses of barren
mulch, there shall be a minimum plant cover of 50 percent within 5 years of planting.
(more)
700 Wood St. • P.O. Box 580 • Fort Collins, CO 80522-0580 • (970) 221-6700 • FAX (970) 221-6619 • TDD (970) 224-6003
e-mail: utilities@fcgov.com • www.fcgov.com/utilities
City staff has determined that the plans are in a condition that enables this
request for a Major Amendment to Pad (Building)6 of Poudre Valley Plaza to be
scheduled for an administrative (Type I) public hearing. The outstanding issues
(from City staff) must and can be addressed prior to the public hearing for the Major
Amendment or with submittal of the final drawings for review and approval of ter the
hearing. The number of copies of each document to re -submit are shown on the
attached Revision Routing Sheet. Be sure and return all red -lined plans when you
re -submit any plans.
If you have any questions regarding these issues or any other issues related to this
project, please feel free to call me at 221-6341.
Yours Truly,
Ok--
Steve Olt
City Planner
Cc: Marc Virata
Fred Croci
Royce Clark
Northern Engineering
Current Planning File #30-95C
Page 8
The following comments were expressed at the City staff review meeting on August 11,
2004:
Engineering:
1. The entry drive into Poudre Valley Plaza from Arbor Avenue must be concrete
from the flowline of the street to the property line.
2. Make the sheet title changes that were expressed in Comment #23 on page 2
of this letter.
Water/Wastewater:
1. The proposed 1" water service into this building is not sufficient. It could be a
1.5" line but probably should be a 2" line.
2. There should be 2 water taps into this building.
3. If there is to be a restaurant in this building then a grease interceptor must be
installed.
Stormwater:
1. The plans must show how the storm water is to be pumped back to the existing
detention pond. Also, the Homeowner's Association must approve the use of the
detention by this building.
Light & Power:
1. Please coordinate the transformer location(s) with Light & Power.
2. A C-1 commercial form must be filled out to help determine the electric needs
of this development.
Transportation Planning:
1. The pedestrian clear space between the columns on the front side and the
building face should be increased.
Page 7
Number: 11 Created: 8/5/2004
[8/5/04] Include the standard general note on the landscape plans pertaining to
landscape/utility separation distance and locates. Show all water and sewer line on the
landscape plans and maintain the required landscape/utility separation distances.
Number: 12 Created: 8/5/2004
[8/5/04] Curb stops must be located within a utility easement.
See site, landscape and utility plans for other comments.
Department: Water Wastewater Issue Contact: Roger Buffington
Topic: Utility plans
Number: 31 Created: 8/11/2004
[8/11/04] A 1-inch water service is not adequate for the number of residential units
shown.
Department: Zoning Issue Contact: Peter Barnes
Topic: zoning
Number: 2 Created: 8/3/2004
[8/3/04] Total overall width/length dimension of building needs to be shown on site
plan. The north/south and the east/west building dimensions don't reflect the total
width/length of the building.
Number: 3 Created: 8/3/2004
[8/3/04] A number of parking stalls are 8.5' wide. Such stalls are considered to be
long term parking stalls and must be labeled "employee parking" of "for residential
parking only" per Sec. 3.2.2(L)(3) and per the definition of "long-term parking" in
Article 5.
Number: 4 Created: 8/3/2004
[8/3/04] Show the distance between Buildings G and F.
Number: 5 Created: 8/3/2004
[8/3/04] Need a land use table or notes describing the intended use(s), number of
dwelling units, number of bedrooms per unit, legal description, lot size, etc.
Number: 6 Created: 8/3/2004
[8/3/04] Need to provide a layout of the basement parking garage in order to
determine design compliance.
Page 6
Department: Transportation Planning Issue Contact: David Averill
Topic: Transportation
Number: 13 Created: 8/5/2004
[8/5/04] Provide an enhanced pedestrian crossing from the proposed sidewalk ramp on
the west side of the building to the north/south walkway west of the drive aisle.
Provide a ramp at the west end of this crosswalk as it connects to the existing
walkway. Also, it's probably not consequential, but the proposed cut doesn't align
perfectly with the east/west walkway across the drive aisle. See redline for
clarification.
Number: 14 Created: 8/5/2004
[8/5/04] I am a little concerned with the clear space along the sidewalk adjacent to
the head in parking at the front of the building. The arcade supports split this
walkway intermittently to varying widths of 2' and 4' feet, with 7' to approximately
12' gaps. The Code requires a 6' minimum sidewalk width where head -in parking is
allowed unless wheel stops are provided, and I'm not sure that this design meets that
requirement.
Number: 15 Created: 8/5/2004
[8/5/04] Provide a handicap access ramp adjacent to the handicap parking stalls,
unless the parking area is proposed to be flush with the adjacent walkway. In that
case wheel stops need to be provided and shown on subsequent plans.
Department: Water Wastewater Issue Contact: Jeff Hill
Topic: Genera/
Number: 7 Created: 8/5/2004
[8/5/04] Clearly define that the existing water and sanitary sewer services are to be
abandoned at the mains. Include the standard general note to "Coordinate the
abandonment with the city utilities.
Number: 8 Created: 8/5/2004
[8/5/04] Clearly define all water and sewer abandonment procedures.
Number: 9 Created: 8/5/2004
[8/5/04] Provide separate water and SEWER services for each use (i.e. commercial vs.
residential). Is a 1-inch water service adequate for a 16 unit building? Provide flow
calculations for the 16 unit residential portion of this building.
Number: 10 Created: 8/5/2004
[8/5/04] Will a grease trap be needed on the commercial sanitary sewer service. If
so show and label location as well as include the appropriate detail.
Page 5
Number: 20 Created: 8/10/2004
[8/10/041 SPRINKLER REQUIREMENTS:
This proposed building shall be fire sprinklered.
Number. 21 Created: 8/10/2004
[8/10/041 FIRE LINE REQUIREMENT:
Buildings that are required to be fire sprinklered shall have a minimum 6-inch fire line
unless hydraulic calculations can support a smaller fire line.
Number: 22 Created: 8/10/2004
[8/10/041 KNOX BOX:
Poudre Fire Authority requires a "Knox Box" to be mounted on the front of every new
building equipped with a required fire sprinkler system or fire alarm system.
1997 UFC 902A PFA POLICY 88-20
Department: Police Issue Contact: Joseph Gerdom
Topic. General
Number: 32 Created: 8/11/2004
[8/11/04] Lighting and photometric plan needed, per Section 3.2.4 of the Land Use
Code. Note lighting levels around basement parking driveway access to Arbor and
interaction between light fixture location and plant materials.
Department: Stormwater Utility Issue Contact: Basil Hamdan
Topic: Erosion Control
Number: 29 Created: 8/10/2004
(8/10/04] Please provide an erosion control plan and appropriate calculations.
Topic: Underground Parking Pump System
Number: 27 Created: 8/10/2004
[8/10/04] Please how where the area that drains to the underground oil/sand
separator will be routed to the detention pond. If it is to be tied to the storm
drainage system, that clearly identify as such on the plans, and provide plans for the
connection from the pump to the detention pond.
Topic: Utility plans
Number: 28 Created: 8/10/2004
[8/10/04] Please add notes indicating that any disturbed areas during construction will
be reseeded or put back to equal or better condition.
Please provide a letter from the HOA allowing the construction of the storm line on
HOA owned property.
Page 4
Department: Light & Power Issue Contact: Rob Irish
Topic: Light d Power
Number: 1 Created: 8/2/2004
[8/2/04] Contact Light & Power with electrical load requirements.
Electric capacity fee & building site charges will apply.
Need to coordinate transformer location with Light & Power.
Any modification or relocation to existing electric facilities will be at owners expense.
Will need to provide C-1 form and One -Line diagram.
Contact Rob Irish 224.6167.
Department: PFA Issue Contact: Michael Chavez
Topic: 6enerai
Number: 17 Created: 8/10/2004
[8/10/041 REQUIRED ACCE55:A fire lane is required. The fire lane shall be visible by
painting and signage, and maintained unobstructed. Buildings three stories or more in
height must have access to a 30 foot unobstructed access roadway on at least (1) one
side for aerial operations. PFA Policy 85-5 (B); 1997 UFC 901.2.2.1; 901.3; 901.4.2;
902.2.1; FCLUC
Number: 18 Created: 8/10/2004
[8/10/041 PREMISES IDENTIFICATION: Approved numerals or addresses shall be
provided for all new and existing building in such a position as to be plainly visible and
legible from the street or road fronting the property. 1997 UFC 901.4.4
A. In Multi -story buildings the following requirements shall pertain.
1. The first floor units shall be designated with 100's.
2. The second floor units with 200's
3. The third floor units with 300's, and so forth.
B. All brass letters and numerals shall be posted on a black background.
C. Some multi -family layouts may require address postings from the back side as well
as
the front of the buildings.
D. A counter clockwise addressing pattern shall be maintained when ever possible.
E. An addressing scheme shall be submitted to the fire department for approval prior
to
being posted on the building.
Number: 19 Created: 8/10/2004
[8/10/04] WATER SUPPLY: Commercial
No commercial building can be greater then 300 feet from a fire hydrant.
Fire hydrants are required with a maximum spacing of 600 feet along an approved
roadway. Each hydrant must be capable of delivering 1500 gallons of water per minute
at a residual pressure of 20 psi. 1997 UFC 901.2.2.2
Page 3
Number: 35 Created: 8/16/2004
[8/16/04] There is a bed of existing Junipers underneath the street trees along
Arbor Avenue. The Landscape Plan does not show these Junipers. Are they to be
removed?
Topic: Site Plan
Number: 36 Created: 8/16/2004
[8/16/04] The columns along the front of the building should be moved out V to give a
2.5' clearance between curb and column and a 5' clearance, for better pedestrian
movement, between building and column.
Number: 37 Created: 8/16/2004
[8/16/04] Is there a wall along the south side of the entry drive into the underground
parking garage and, if so, how tall is it above the ground adjacent to it? Please show
this on the Site Plans and Landscape Plan.
Department: Engineering Issue Contact: Marc Virata
Topic: Genera/
Number: 23 Created: 8/10/2004
[8/10/04] Please rename all document titles to read Poudre Valley Plaza PUD, The
Promenade.
Number: 24 Created: 8/10/2004
[8/10/04] In general, there is existing sidewalk along Arbor Avenue adjacent to the
site that is not in good condition/has settled and needs to be replaced. Add a note on
the construction plat set indicating the following: "Sidewalk shall be replaced along
Arbor Avenue at the discretion of the City Engineering Inspector at the time of
construction."
Number: 25 Created: 8/10/2004
[8/10/04] The new access ramp at the southwest corner of the site out to Arbor
Avenue needs to have truncated domes in the construction, a detail will be provided.
Also, the irrigation control box shown partially in the sidewalk will need to be
relocated.
Number: 30 Created: 8/10/2004
[8/10/04] The driveway out to Arbor Avenue needs to show a concrete driveway fully
to the property line.
Page 2
Lockwood Architects, Inc.
c/o Dann Lockwood
217 Jefferson Street
Fort Collins, CO. 80524
STAFF PROJECT REVIEW
Date: 08/16/2004
Staff has reviewed your submittal for POUDRE VALLEY PLAZA, PAD 6 - MAJOR
AMENDMENT - TYPE I (LUC), and we offer the following comments:
ISSUES:
Department: Current Planning Issue Contact: Steve Olt
Topic: Building Arch. dr Agt.
Number: 16 Created: 8/10/2004
[8/10/04] Section 3.5.1(6) of the Land Use Code deals with "special" Building Height
Review of buildings that exceed 40' in height. Four elements are reviewed, being Views,
Light & Shadow, Privacy, and Neighborhood Scale. To be submitted for Special Building
Height Review are: a shadow analysis, a visual analysis, and a summary of key
conclusions. The shadow analysis has been submitted for review and does indicate that
this building will have no adverse shade/shadow impact on properties outside of the
project it will be a part of (Poudre Valley Plaza). However, no information has yet been
provided to demonstrate the visual impacts of the building on residential
neighborhoods to the east and south. It is important to graphically depict the potential
impacts on views of the foothills from the neighborhoods and, through a narrative, to
discuss the potential privacy and neighborhood scale implications.
8/16/04 ..... 3 copies of a visual analysis, with narrative submitted to the City for
review.
Topic: Landscape Plan
Number: 33 Created: 8/16/2004
[8/16/04] There should be additional landscaping at the southwest corner of the
building (see red -lined Landscape Plan), possibly to include shrubs and an ornamental
tree.
Number: 34 Created: 8/16/2004
(8/16/04] Some additional shrubs should be added around the southeast corner of the
trash enclosure.