Loading...
HomeMy WebLinkAboutMASON ST. NORTH, MAJOR AMEND. - FDP - 4-97C - SUBMITTAL DOCUMENTS - ROUND 1 -March 24, 2004 Project No: 1558-02-01 Re: Responses to Comments Dated 02/25/04 Mason Street North; Ft. Collins, Colorado Previously Lot 12 and Tract A, Martinez P.U.D. Attachments March 2, 2004 Letter from Terracon January 16, 2002 Letter from Terracon responding to Geotechnical Comments Responses from Wolff -Lyon Architects Copies of agreement forms for Burlington Northern Railroad Copy of final plat for Martinez P.U.D. (recorded) Page 14 March 24, 2004 Project No: 1558-02-01 Re: Responses to Comments Dated 02/25/04 Mason Street North; Ft. Collins, Colorado Previously Lot 12 and Tract A, Martinez P.U.D. 162. "Created: 121612001. The thrust block on the fire hydrant on Mason Court will not have undisturbed earth behind it; therefore, restrain all joints between hydrant and the 12x12x8 tee on the east side of Mason Court. Can hydrant be placed on east side of Mason Court? R. Acknowledged: The joints between hydrant and the 12x12x8 tee on the east side of Mason Court will be restrained with mega lugs. 163. "Created: 121612001. Maintain 5 foot separation between raised planter boxes and water service/meter pits. " R. Acknowledged: The planter box has been reconfigured to enclose the water service/meter pit near Building B. 164. "Created: 121612001. See additional comments on plans. " R. Acknowledged: The additional comments have been revised on the current set of Final Utility Plans. If you have any questions, please call me at (970) 226-5334. Sincerely, Seth W. Tourney, E.I. Shear Engineering Corporation SWT/BWS cc: Jim Leach; Wonderland Hill Development Company Mickey Willis, Paradigm Realty Korkut Onaran; Wolff - Lyon Architects Mike Lang; Sear Brown Group Katie Moore; City of Fort Collins Engineering Wes Lamarque; City of Fort Collins Stormwater Utility Jeff Hill; City of Fort Collins Water Wastewater Craig Foreman; City of Fort Collins Parks and Rec. Ron Gonzales; Poudre Fire Authority Page 13 March 24, 2004 Project No: 1558-02-01 Re: Responses to Comments Dated 02/25/04 Mason Street North; Ft. Collins, Colorado Previously Lot 12 and Tract A, Martinez P.U.D. 150. "Created: 1113012001. Lower storm sewer in order to allow water main to cross above storm sewer and to prevent a lowering of water main. " R. Acknowledged: Done. 151. "Created: 1113012001. Provide appropriate scales for all plan and profile views. " R. Acknowledged: Done. Water Wastewater Issue Contact: Roger Buffington Topic: Utility Plans 157. "Created: 121612001. Plan sheet 13 includes details which appear to be for a subdrain. Is there a subdrain on the project? What is this detail to be used for? " R. Notes have been added to these details for clarity. 158. "Created: 121612001. Plan sheet 13 includes a manhole base detail that is not a City standard detail. What is this detail to be used for? " R. Please refer to Item 5 on the Master Improvements Plan. 159. "Created: 121612001. Re -align the water main at the SE corner of the building. " R. Acknowledged: Done. 160. "Created: 121612001. Move 6-inch water line on NW side of building into the drive as noted on the plans. " R. Acknowledged: Done. 161. "Created: 121612001. What is the elevation of the abandoned 36-inch storm sewer in Cherry Street at the point of crossing with the 8-inch water main? If there is a conflict, remove abandoned storm sewer 5 feet each side of water main and plug ends of storm sewer with concrete. " R. There is not a conflict between the 36-inch storm sewer and the 8-inch water main. The water main is well above the storm sewer. See Sheet 3 of the Final Utility Plans for elevations here. Page 12 March 24, 2004 Project No: 1558-02-01 Re: Responses to Comments Dated 02/25/04 Mason Street North; Ft. Collins, Colorado Previously Lot 12 and Tract A, Martinez P.U.D. 166. "Created: 1211012001. Please provide calculation & cross-section for area just west of Building C to verify 100 year flows will turn corner and not inundate the underground parking. See drainage plan. " R. Acknowledged: The 100-year flow will turn this corner. Please refer to Flow Tram West of Building C in Appendix I of the Final Drainage and Erosion Control Report. 167. "Created: 1211012001. Please provide an outfall for the sub -basin south of the railroad tracks. The parking lot drains to the east along the south side of the railroad tracks to a low lying area. With some regrading to the south of the railroad tracks and the inlet in sub - basin 1 d enlarged, flows from the south parking lot may be able to dump into the box culvert at this inlet. " R. Acknowledged: Done. An inlet is now proposed for this area south of the railroad tracks. Water Wastewater Issue Contact: Jeff Hill Topic: General 146. "Created: 1113012001. Place all water and sewer mains in roadways/drives when possible. " R. Acknowledged: Done. 147. "Created: 1113012001. Provide elevation views for buildings 'A' and 'B' for our review. All individual buildings must provide their own services. " R. Acknowledged: After coordinating with Wolff -Lyon Architects, it is our understanding that they will be providing these drawings. 148. "Created: 1113012001. Eliminate all unnecessary water line fittings when possible. " R. Acknowledged: Done. 149. "Created: 1113012001. Show all proposed water and sewer services on the overall utility plans ( including proposed irrigations taps). " R. Acknowledged: Done. Page 11 March 24, 2004 Project No: 1558-02-01 Re: Responses to Comments Dated 02/25/04 Mason Street North; Ft. Collins, Colorado Previously Lot 12 and Tract A, Martinez P.U.D. 113. "Created: 1112012001. Please provide identifier for benchmarks. (repeat comment) " R. Acknowledged: The benchmarks have been revised to reflect the City of Fort Collins Vertical Control aluminum caps. 114. "Created: 1112012001. Please provide a P.E. signature and stamp for next submitted reports. " R. Acknowledged: Done. 115. "Created: 1112012001. Erosion Control Comments:" R. Acknowledged: "Please provide calculations" R. Acknowledged: Done. "The BMP's noted in the report are not translated to the plan well or are not shown on the plan —please correct. " R. Acknowledged: Done. 116. "Created: 1112012001. Please revise QI00 values in the plans and report. Incorrect intensity was used for all QI00 calculations. Incorrect intensities were also used to calculate the Q2 but the error was on the conservative side. " R. Acknowledged: Done. Topic: Drainage 165. "Created: 1211012001. The proposed 48-inch storm sewer near Building C is within a few feet of the building. Please investigate whether or not the waterline could be relocated farther south, thus allowing for the storm sewer to be moved at least 10 feet from the building. See Sheet 6. This may require an easement within the railroad easement. If this is not possible, an alternative would be to use water tight pipe like DIP, for the area in front of Building C. " R. The plans have been revised to use Ductile Iron Pipe (DIP) for this stretch of storm sewer. Page 10 E March 24, 2004 Project No: 1558-02-01 Re: Responses to Comments Dated 02/25/04 Mason Street North; Ft. Collins, Colorado Previously Lot 12 and Tract A, Martinez P.U.D. 156. "Created: 121512001. Please use phantom lines for existing features so that a differentiation can be made between what is existing and what is proposed. (This applies to all sheets) " R. Acknowledged: Done. 168. "Created: 1211212001. Please note that under the variance for parking setbacks along Mason Court, a minimum of 20' must be maintained. Please configure parking to meet this requirement. " R. Acknowledged: Done. Topic: Utility Plans 48. "Created: 91412001. Please provide more information regarding the median shown in Cherry. Grading information and cross-section(s) are needed. It is assumed that the developer will build it. If landscaping is proposed, please include a line for irrigation, and know that it will be the responsibility of the developer to maintain the landscaping. The median should be enlarged to provide adequate visibility, but not encroach on left turn stacking lengths at either Mason or Howes or the movement of turning buses off of Mason onto Cherry. The design should also take into consideration that Howes will most likely be a 2-way street in the future. The ends should also be made less blunt. It has also been suggested that this would be a good place for art in public places. " R. Acknowledged: The plans provided more information regarding the median shown in Cherry Street. No irrigated landscape is being proposed for this median. 144. "Created: 1112912001. The design and construction of the median in Cherry needs to be completed with this project. Please re -include the median in this plan set. Construction of the median will most likely be required by the time of Certificate of Occupancy for the buildings. " R. Acknowledged. Stormwater Utility Issue Contact: Wes Lemarque 112. "Created: 1112012001. Please provide Swale cross -sections and calculations for all swales. (repeat comment)" R. Acknowledged: Done. Page 9 March 24, 2004 Project No: 1558-02-01 Re: Responses to Comments Dated 02/25/04 Mason Street North; Ft. Collins, Colorado Previously Lot 12 and Tract A, Martinez P.U.D. Topic: Site Plan 30. "Created: 91412001. Please match easements with Utility plan and Plat." R. Acknowledged: Done. 36. "Created: 91412001. Please see plan for additional comments." R. Acknowledged. 41. "Created: 91412001. Please show all ramps." R. Acknowledged: Done. 123. "Created: 1112312001. There are still areas where the 6' minimum sidewalk width is not being met where cars overhang the sidewalk. " R. Acknowledged: The sidewalk widths have been adjust to a 6' minimum where cars could overhang the sidewalk. 124. "Created: 1112312001. There is inadequate backing distance behind the westernmost garage south of the railroad tracks. " R. Acknowledged: The pavement has been extended to provide adequate backing distance. 126. "Created: 1112312001. Where is the public access easement(s) for the area south of the RR tracks? " R. Acknowledged: Public access easements for the area south of the railroad tracks will be proposed on the plat upon availability. 127. "Created: 1112312001. The utility easement along the south side of Mason Court should be 9 feet per LCUASS figure 7-9F. Please provide this width. " R. There has been a variance approved by the City Engineer to accommodate this issue. Please refer to the attached letter from Katie Moore dated l 2/21 /2001. 128. "Created: 1112312001. Please note that for the certain portion of building A that crosses over the electric easement, that the easement has been vacated above a certain elevation and that portion of the building is permissible there. " R. Acknowledged. Page 8 M March 24, 2004 Project No: 1558-02-01 Re: Responses to Comments Dated 02/25/04 Mason Street North; Ft. Collins, Colorado Previously Lot 12 and Tract A, Martinez P.U.D. 65. "Created: 91512001. Please label in writing that all driveways are concrete to the ROW" R. This label is provided on the .Larimer County Urban Area Street Standard Drawing 7-29A Standard Driveway approach (Types I & II), which is included in the Final Utility Plans. 134. "Created: 1112312001. Where are the sight distance easements? " R. The sight distance easements can be found on the site plan prepared by Wolff -Lyon Architects, and the sight distance easements can be found on Sheet 3 in the Final Utility plans. 135. "Created: 1112312001. Please show striping on Cherry Street. (repeat) " R. Acknowledged: Done. 136. "Created: 1112312001. It appears that an offsite easement is needed for work to be done to the west of the property just north of Cherry. " R. Plans have been revised to keep all construction within the boundaries of this property. However, it should be noted that the same interested parties own the adjacent property. Topic: Sheet 4 69. "Created: 91512001. Regarding general note 6: All easements should be shown on the utility plans. " R. Acknowledged: Done. Topic: Sheet 5 137. "Created: 1112312001. Where is MH A-1 shown on the plan view of the sanitary sewer? " R. MH A-1 was previously mislabeled in the profile view, and this has been revised to MH A- 3. Topic: Sheet 6 138. "Created: 1112312001. Please show the street cut to be made on Cherry. " R. Acknowledged: Done. Please refer to the Master Improvements Plan. Page 7 n March 24, 2004 Project No: 1558-02-01 Re: Responses to Comments Dated 02/25/04 Mason Street North; Ft. Collins, Colorado Previously Lot 12 and Tract A, Martinez P.U.D. 119. "Created: 1112312001. Please include a legal description of the height limitation on the Light and Power easement as it passes underneath the building. " R. Please refer to response by Wolff -Lyon Architects attached with this letter. 120. "Created: 1112312001. Please verify that the gas company and light and power are amenable to the areas where their exclusive easements are infringed upon. " R. Acknowledged: After coordination with Janet .McTagg in the light and power department, she acknowledged the manhole near Building A within a portion of their easement. She stated that this would be fine, and she agreed to contact Katie Moore to verify their approval. 121. "Created: 1112312001. Please provide a line for the Railroad to sign on." R. When we were designing Martinez P.U.D., the railroad did not request a signature on the final plat. To maintain consistency with past formats between this Final Plat and the Martinez P.U.D. final plat, a railroad signature block will not be provided on this final plat. This was confirmed with the railroad. Agreements are currently being coordinated with the Burlington Norther Santa Fe Railroad through Staubach Global Services. The agreements will be provided to you immediately upon execution of those agreements. Refer to copies of the agreements attached with this response for your immediate reference. Topic: Sheet 3 56. "Created: 91512001. Please use phantom lines for existing features/buildings adjacent to site. " R. Acknowledged: Done. 61. "Created: 91512001. Please calculate sight distance easements needed using figure 7-16 (LCUASS) and show on the plat and utilityplans and site and landscape plans. " R. Acknowledged: Done. 62. "Created: 91512001. Drainage is not allowed over public sidewalks (7.7.4 and 9.4.11 A & B, LCUASS). Please use under -walk pans as shown in detail 7-31. " R. Acknowledged: Done. Page 6 March 24, 2004 Project No: 1558-02-01 Re: Responses to Comments Dated 02/25/04 Mason Street North; Ft. Collins, Colorado Previously Lot 12 and Tract A, Martinez P.U.D. 122. "Created: 1112312001. The building outlines/footprints don't seem to match from the Site plan to the landscape plan. " R. Acknowledged: Done. These have been corrected to match. Topic: Plat 42. "Created: 91412001. Please correct wording as redlined and add Sight Distance Easement language. " R. Acknowledged: This will be provided upon availability. 44. "Created: 91412001. Please clearly label all existing and proposed easements and ROW." R. Acknowledged: This will be provided upon availability. 45. "Created: 91412001. Please label all adjoining properties. " R. Acknowledged: This will be provided upon availability. 46. "Created: 91412001. These easements do not match what is shown on the site plan. Please coordinate. " R. Acknowledged: This will be provided upon availability. 47. "Created: 91412001. Please see plat for additional comments." R. Acknowledged. 117. "Created: 1112312001. Please dedicate a 9' utility easement along Mason Court as shown in LCUASS Figure 7-9F. " R. Please refer to response by Wolff -Lyon Architects attached with this letter. Also, note that this easement has been granted a variance to 8' in a letter from Katie Moore dated December 31, 2001. 118. "Created: 1112312001. Please add a note to the cover sheet referring to the vacation of old easements if they are not shown on this plat (repeat). " R. Acknowledged: This will be provided upon availability. Page 5 March 24, 2004 Project No: 1558-02-01 Re: Responses to Comments Dated 02/25/04 Mason Street North; Ft. Collins, Colorado Previously Lot 12 and Tract A, Martinez P.U.D. R. Acknowledged: Mickey Willis has been coordinating with Craig Foreman of the parks department. Parks Department approvals on the Final Utility Plans will reflect their approvals of work performed on park property. 139. "Created: 1112312001. Please provide a detail of the retaining wall. " R. Acknowledged: Done. There are two (2) retaining wall details represented on the plans. The "Ready Rock" retaining wall detail is for the retaining wall required on the north side of the new parking spaces on the north side of the existing private drive. The other retaining wall detail is for the drive into the underground parking for Building C. 140. "What is the elevation of the basement floor? (repeat) " R. The basement floor elevation in Building C is 4907.17 ft. This elevation is shown in the Final Utility Plans now. 154. "Created: 121512001. Presently, new grading is shown under the railroad tracks. Shouldn't that be adjusted so that the tracks are not affected?" R. Acknowledged: Done. Topic: Landscape Plan 37. "Created: 91412001. Please match with other plans/plat. " R. Acknowledged: Done. 38. "Created: 91412001. Landscaping in median in bulb of cul-de-sac needs to meet Sight distance easement restrictions. Please see the attached form for restrictions and include these restrictions on both the landscape plan and the plat. " R. Acknowledged: Sight distance easement restrictions have been added. 39. "Created: 91412001. Further sight distance easement areas should be identified for the next submittal. Please note that landscaping in these areas needs to meet the restrictions as well. See LCUASS Drawing 7-16 for calculation of sight distance easements. The 110' shown is inadequate. " R. Acknowledged: Done. Page 4 March 24, 2004 Project No: 1558-02-01 Re: Responses to Comments Dated 02/25/04 Mason Street North; Ft. Collins, Colorado Previously Lot 12 and Tract A, Martinez P.U.D. 142. "Created: 1112312001. No design has been shown for the subdrains needed for building C per the soils report. Please show how subdrains will tie into an approved discharge facility. " R. Acknowledged: A 12" RCP is being provided from the basement of Building C and discharging into the water quality pond system on parks land to the north of the property. This will exist within the drainage easement on park's land. This was coordinated with the actual building design. Subdrains for the actual building will be designed with the building and incorporated with the building plans. 143. "Created: 1112912001. The driveway between buildings A and B may be 18' in width; the driveway between buildings B and C may be 22' in width, and the driveway access off of Cherry must be a minimum of 24' in width per the Variance Request approvals and denials. " R. Acknowledged: Done. 145. "Created: 1112912001. The comments numbered lower than 117 are repeat comments. " R. Acknowledged: The comments numbered lower than 117 are being accommodated on an item -by -item basis. 152. "Created: 1113012001. Please refer to the redlined utility plan checklist for further comments. " R. Acknowledged. Topic: Geotechnical Report 153. "Created: 1113012001. Subsurface report does not address issues as outlined in LCUASS 5.6" R. Please see the attached letter from Terracon dated March 2, 200i' and response letter dated January 16, 2002. Topic: Grading 75. "Created: 91512001. Offsite grading/other work performed on Parks' land requires their approval. Please provide a letter from the Parks department stating their approval of what is shown on their property. " Page 3 March 24, 2004 Project No: 1558-02-01 Re: Responses to Comments Dated 02/25/04 Mason Street North; Ft. Collins, Colorado Previously Lot 12 and Tract A, Martinez P.U.D. 133. "Created: 1112312001. Please provide a signature line for the railroad. " R. When we were designing Martinez P.U.D., the railroad did not request a signature on the final utility plan set. To maintain consistency with past formats between these Final Utility Plans and the Martinez P.U.D. final utility plans a railroad signature block will not be provided on this plan set. This was confirmed with the railroad. Agreements are currently being coordinated with the Burlington Northern Santa Fe Railroad through Staubach Global Services. The agreements will be provided to you immediately upon execution of those agreements. Refer to copies of the agreements attached with this response for your immediate reference. Topic: Drainage 155. "Created: 121512001. Please provide a legal description and sketch of the required drainage area on Parks' land. These will be used to file a Notice of Facility Location in lieu of an Easement. " R. A drainage easement on the park's property to the north was recorded under separate document according to the recorded plat for Martinez P.U.D. Please refer to the copy of the recorded final plat of Martinez P.U.D. attached for your immediate reference. The same easement will be identified on the final plat for Mason Street North as well. Topic: General 54. "Created: 91512001. Please see sheet for any additional comments" R. Acknowledged. 74. "Created: 91512001. Any work done within the RR ROW/easement requires approval by the railroad. Please provide a letter of intent from the Railroad regarding these improvements (grading, landscaping, pedestrian crossing, etc.). " R. Acknowledged: Coordination with Gene Biddle with Staubach Global Services representing the Burlington Northern Same Fe Railroad is currently underway to achieve approvals from the BNSF. Agreements are currently being coordinated. The agreements will be provided to you immediately upon execution of those agreements. Refer to copies of the agreements attached with this response for your immediate reference. 141. "Created: 1112312001. Please provide the under -walk drain detail from LCUASS. " R. Acknowledged: Done. Page 2 March 24, 2004 Project No: 1558-02-01 City of Fort Collins Planning P.O. Box 580 Ft. Collins, Colorado 80524 Attn: Steve Olt Re: Responses to Staff Project Review Comments Dated 02/25/04 Mason Street North; Ft. Collins, Colorado Previously Lot 12 and Tract A, Martinez P.U.D. Dear Mr. Olt, This letter provides responses to review comments concerning Staff Project Review for Mason Street North (Major Amendment to Martinez P.U.D.), #4-97B dated February 25, 2004, even though many of these comments are from 2001. The Final Utility Plans, Final Plat, and Final Drainage and Erosion Control Report redlines have been addressed with this resubmittal. The responses follow the numbering order presented in the summaries. Engineering Issue Contact: Katie Moore Topic: Cover sheet 55. "Created: 91512001. Please correct general notes as shown." R. Acknowledged: Done. 130. "Created: 1112312001. Please list the Developer and Owner of this project. (repeat) " R. Acknowledged: Done. 131. "Created: 1112312001. Please lighten the vicinity map so that it is legible/reproducible. " R. Acknowledged: Done. 132. "Created: 1112312001. Please show the indemnification statement separately from the signature block and include only on the cover sheet. " R. Acknowledged: The indemnification statement has been separated from the signature block and is only included on the cover sheet. 4836 S. College, Suite 12 Ft. Collins, CO 80525 (970) 226-5334 Fax (970) 282-0311 www.shearengineering.com