HomeMy WebLinkAboutPEDERSEN AUTO PLAZA - PDP/FDP - 26-97 - P&Z PACKET - RECOMMENDATION/REPORTPedersen Auto Plaza, Project Development Plan, #26-97
March 19, 1998 P & Z Meeting
Page 15
standards located in Section 3.2.1(E)(4) - Parking Lot Perimeter
Landscaping, Section 3.2.2(J) - Setbacks of ARTICLE 3 - GENERAL
DEVELOPMENT STANDARDS. An alternative landscape plan, in
accordance with Alternative Compliance [Section 3.2.1(N)] in the LUC,
has been submitted for consideration.
" standards located in Section 3.5.3(B)(2) - Relationship of Buildings to
Streets, Walkways and Parking (build -to line) of ARTICLE 3 -
GENERAL DEVELOPMENT STANDARDS. A request for a modification
to the standards has been submitted for consideration.
C. The PEDERSEN AUTO PLAZA, PDP is compatible with the surrounding land
uses.
RECOMMENDATION:
Staff recommends approval of the request.for an alternative landscape and tree
protection plan [to Section 3.2.2(J)] in accordance with Section 3.2.1(N) - Alternative
Compliance of the LUC.
Staff recommends approval of the request for modification to standards as set forth in
Section 3.5.3(B)(2) - Orientation to Build -to Lines for Streetfront Buildings and
Section 3.5.3(B)(2)(b) - Build -to Line of the LUC.
Staff recommends approval of the PEDERSEN AUTO PLAZA, Project Development
Plan - #26-97.
Pedersen Auto Plaza, Project Development Plan, #26-97
March 19, 1998 P & Z Meeting
Page 14
Zoning District, subject to Planning and Zoning Board (Type II) review. The purpose of
the C - District is:
Intended to be a setting for development, redevelopment and infill of a wide
range of community and regional retail uses, offices and personal and business
services. Secondarily, it can accommodate a wide range of other uses including
creative forms of housing.
While some Commercial District areas may continue to meet the need for auto -
related and other auto -oriented uses, it is the City's intent that the Commercial
District emphasize safe and convenient personal mobility in many forms, with
planning and design that accommodates pedestrians.
This proposal complies with the purpose of the C - District as it provides community and
regional retail and ancillary uses in a community/regional shopping area of Fort Collins
(the South College Avenue corridor). The retail portion of the operation is the new auto
showroom, display, and sales. The ancillary uses are the auto servicing, express lube
services, auto body repair, auto parts storage, retail parts sales portions of the
operation, for both this facility and the existing Pedersen Toyota -Volvo -Saab facility
block to the east on Kensington Drive. This Pedersen facility would replace their
existing auto service and repair facility located on the east side of South College
Avenue at the intersection of Troutman and JFK Parkways. This is an auto -oriented
facility in an area along South College Avenue that includes a number of auto
dealerships, auto maintenance and repair shops, and auto parts and supply stores. The
site has been designed to provide and emphasize safe and convenient pedestrian
movement from the Mason Street sidewalk system to the public entries into the facility
along the east side.
Section 4.17(E) Development Standards
The proposal satisfies the applicable development standards in the C - Commercial
Zoning District.
5. Findings of Fact/Conclusion:
A. The PEDERSEN AUTO PLAZA, PDP contains uses permitted in the C -
Commercial Zoning District, subject,to. review by the Planning and Zoning Board.
B. The PEDERSEN AUTO PLAZA, PDP meets all applicable standards as put forth
in the Luc, including Division 3.2 - Site Planning and Design Standards,
Division 3.5 - Building Standards, and Section 3.6 - Transportation and
Circulation, with the following exceptions:
Pedersen Auto Plaza, Project Development Plan, #26-97
March 19, 1998 P & Z Meeting
Page 13
(C) the granting of a modification from the strict application of any standard
would result in a substantial benefit to the City by reason of the fact that
the proposed project would substantially address an important community
need specifically and expressly defined and described in the City's
Comprehensive Plan, adopted policy, ordinance or resolution (such as, by
way of example only, affordable housing or historic preservation) or would
substantially alleviate an existing, defined and described problem of city-
wide concern (such as, by way of example only, traffic congestion or
urban blight), and the strict application of such a standard would render
the project practically infeasible.
Staff finds that the project as submitted, based on the land use and its contextual
compatibility with the surrounding land uses, is neither detrimental to the public
good nor impairs the intent and purposes of this chapter of the City Code; and
that it will protect the public interests and purposes of the standards for which
this modification is requested equally well than would a plan which complies with
the standards for which the modification is requested. The design of the
pedestrian/vehicle interface would minimize potential conflicts between
pedestrians entering the site and cross vehicular movements. Therefore, staff is
recommending that the Planning and Zoning Board approve the request for a
modification to the standards.
C. Division 3.6 - Transportation and Circulation
Section 3.6.4. Transportation Level of Service Requirements
The proposal satisfies the applicable Transportation Level of Service standards (see
the attached Traffic Impact Study), including the following:
General Standard. This development proposal satisfies Section 3.6.4(8), which
requires that all development plans adequately provide vehicular, pedestrian and
bicycle facilities necessary to maintain the adopted transportation Level of
Service standards contained in Part II of the City of Fort Collins Multi -Modal
Transportation Level of Service Manual for the following modes of travel: Motor
vehicle, bicycle and pedestrian.
4. ARTICLE 4 - DISTRICTS
A. Division 4.17 - Commercial District
Vehicle major repair, servicing and maintenance establishments and vehicle sales and
leasing establishments with outdoor'storage are permitted in the C - Commercial
Pedersen Auto Plaza, Project Development Plan, #26-97
March 19, 1998 P & Z Meeting
Page 12
Build -to Line. Section 3.5.3(B)(2)(b) states that:
Buildings shall be located no more than 15' from the right-of-way of an
adjoining street if the street is smaller than a full arterial or has on -street
parking.
The building as proposed maintains an 80' setback from South Mason Street.
The proposed site layout would provide for two direct pedestrian sidewalk
connections from the detached sidewalk along Mason Street to the entryways on
the front of the building. However, they would both have identified pedestrian
crossings across internal driveways. The applicant has submitted a request for
modification of the aforementioned standards for the following reasons:
"The Build -To Line is intended to promote pedestrian oriented streetfronts.
Recent development along Mason Street has not built to this standard,
establishing a pattern of existing buildings which are not pedestrian -
oriented in the spirit of this Article. This standard is not consistent with the
established character of the existing Mason Street corridor.
This specific project is located on a curve in Mason Street makes this
standard even more difficult.
Most important, the nearly single focus of this project is auto related. By
its nature, people will be driving their cars to this facility for the services
offered. Few people will be walking to and from this development. Cars
will be delivered, serviced, stored and displayed on this site. The facilities
must efficiently accommodate the automobile. The building itself must
accommodate the entry and exit of the auto from all sides, limiting the
minimum distance to any property line.
The Build -To Line standard will not accommodate this use on this site."
Modification requests may be granted if the Planning and Zoning Board
determines that:
(A) the granting of the modification would neither be detrimental to the public
good nor impair the intent and purposes of this Chapter; and
(B) the plan as submitted will advance or protect the public interests and
purposes of the standard for which the modification is requested equally
well or better than would a plan which complies with the standard for
which a modification is requested; or
Pedersen Auto Plaza, Project Development Plan, #26-97
March 19, 1998 P & Z Meeting
Page 11
pedestrians entering the site and cross vehicular movements. Therefore, staff is
recommending that the Planning and Zoning Board approve the request for a
modification to the standard.
Building materials. The proposed structures will consist of the following
building materials:
The building will be of a stucco finish, off-white and medium gray in color,
similar to the Pedersen Toyota -Volvo -Saab dealership on South College
Avenue, % block to the east.
The roof will be constructed of standing seam metal, similar to that on the
Pedersen Toyota -Volvo -Saab dealership.
These materials comply with the standard in Section 3.5.1(F)(1), which states:
Building materials shall either be similar to the materials already being
used in the neighborhood, or, dissimilar materials are being proposed,
other characteristics such as scale and proportions, form, architectural
detailing, color and texture, shall be utilized to ensure that enough
similarity exists for the building to be compatible, despite the differences in
materials. '
The materials on this building will be similar to those used on the existing
Pedersen Toyota -Volvo -Saab dealership and the commercial facilities in the
block to the south and east. They are constructed of a combination of masonry
block and stucco and are all off-white, light gray, and medium gray in color.
Section 3.5.3. Mixed -Use; Institutional and Commercial Buildings
The proposal does not satisfy the Relationship of Buildings to Streets, Walkways
and Parking standards, more specifically:
Orientation to Build -to Lines for Streetfront Buildings. Section 3.5.3(B)(2)
states that:
Build -to lines based on a consistent relationship of buildings to the street
sidewalk shall be established by development projects, in order to form
visually continuous, pedestrian -oriented streetfronts with no vehicle use
area between building faces and the street.
Pedersen Auto Plaza, Project Development Plan, #26-97
March 19, 1998 P & Z Meeting
Page 10
accommodate the entry and exit of the auto from all sides, limiting the
minimum distance to any property line.
The Build -To Line standard will not accommodate this use on this site."
Paragraphs 1 and 3, above, apply to this section of the LUC and, therefore, the
applicant's request for a modification to the standard is applicable. There is a
perceived character along the South Mason Street corridor (commercial uses
that generally have an auto -related emphasis). This project is auto -oriented and
the nature of the uses in the facility suggest that it provide for entry and exit of
autos from all sides.
Modification requests may be granted if the Planning and Zoning Board
determines that:
(A) the granting of the modification would neither be detrimental to the public
good nor impair the intent and purposes of this Chapter; and
(B) the plan as submitted will advance or protect the public interests and
purposes of the standard for which the modification is requested equally
well or better than would a plan which complies with the standard for
which a modification is requested; or
(C) the granting of a modification from the strict application of any standard
would result in a substantial benefit to the City by reason of the fact that
the proposed project would substantially address an important community
need specifically and expressly defined and described in the City's
Comprehensive Plan, adopted policy, ordinance or resolution (such as, by
way of example only, affordable housing or historic preservation) or would
substantially alleviate an existing, defined and described problem of city-
wide concern (such as, by way of example only, traffic congestion or
urban blight), and the strict application of such a standard would render
the project practically infeasible.
Staff finds that the project as submitted, based on the land use and its contextual
compatibility with the surrounding land uses, is neither detrimental to the public
good nor impairs the intent and purposes of this chapter of the City Code; and
that it will protect the public interests and purposes of the standard for which this
modification is requested equally well than would a plan which complies with the
standard for which the modification is requested. The design of the
pedestrian/vehicle interface would minimize potential conflicts between
Pedersen Auto Plaza, Project Development Plan, #26-97
March 19, 1998 P & Z Meeting
Page 9
B. Division 3.5 - Building Standards
Section 3.5.1. Building and Project Compatibility
The PEDERSEN AUTO PLAZA, PDP does not satisfy all applicable Building and
Project Compatibility standards, more specifically:
Building orientation. The building placement and orientation on this proposal
does not comply with Section 3.5.1(D), which states that:
To the maximum extent feasible, primary facades and entries shall face
the adjacent street. Except as allowed in the Industrial zone district, a
main entrance shall face a connecting walkway with a direct pedestrian
connection to the street without requiring all pedestrians to walk through
parking lots or cross driveways.
The building as proposed orients the primary entries to South Mason Street.
Because of the auto service, maintenance, and repair uses, there is an 80'
setback from the street to allow for vehicular circulation into, through, and around
the building. Parking is also being proposed near the building entries. The site
layout would provide for two direct pedestrian sidewalk connections, each with
driveway crossings, from the detached sidewalk along Mason Street to the
entryways on the front of the building. They will both have identified, striped
pedestrian crossings at the internal driveway. The applicant has submitted a
request for modification of the standards set forth in Sections 3.5.3(8)(2) and
3.5.3(8)(2)(b) for the following reasons:
"The Build -To Line is intended to promote pedestrian oriented streetfronts.
Recent development along Mason Street has not built to this standard,
establishing a pattern of existing buildings which are not pedestrian -
oriented in the spirit of this Article. This standard is not consistent with the
established character -of the existing Mason Street corridor.
This specific project is located on a curve in Mason Street makes this
standard even more difficult.
Most important, the nearly single focus of this project is auto related. By
its nature, people will be driving their cars to this facility for the services
offered. Few•people will be walking to and from this development. Cars
will be delivered; serviced, stored and displayed on this site. The facilities
must efficiently accommodate the automobile. The building itself must
Pedersen Auto Plaza, Project Development Plan, #26-97
March 19, 1998 P & Z Meeting
Page 8
Board shall take into account whether the alternative preserves and incorporates
existing vegetation in excess of minimum standards, protects natural areas and
features, maximizes tree canopy cover, enhances neighborhood continuity and
connectivity, fosters nonvehicular access, or demonstrates innovative design and
use of plant materials and other landscape elements.
The Landscape Plan as submitted proposes to construct the curbline of the auto
display area up to the north easement line for future pedestrian trail between
South Mason Street and the railroad corridor. Within this easement will be a
combination of deciduous and evergreen shrubs that may or may not be able to
be incorporated into the future pedestrian trail alignment at the time it is
constructed. At the time the trail is constructed the property owner may or may
not install a fence along the curbline of the parking area, just outside of the
easement. The property owner would receive a zero setback from the easement
line in exchange for providing the 12' wide access easement for the future trail.
Staff is recommending that the alternative Landscape Plan be approved based
on the final plan enhancing neighborhood continuity and connectivity, and
fostering nonvehicular access between the South College Avenue commercial
corridor and the future multi -modal transportation corridor along the Burlington
Northern Railroad tracks.
Required number of parking spaces. The development proposal satisfies the
parking requirements set forth in the LUC for the vehicle servicing and
maintenance, general retail (auto sales), and general office uses in this project.
There are 137 proposed parking spaces on -site, equaling 4.6 spaces per
1,000 square feet of leasable floor area. Section 3.2.2(K)(2)(a) sets forth
maximum parking requirements for non-residential land uses. They range
from 3 spaces per 1,000 square feet (for general office), to 4 spaces per
1,000 square feet (for retail), -to 5 spaces per 1,000 square feet (for
vehicle servicing and maintenance) of leasable floor area, depending on
the type of use. There is no category for allowable parking for the auto
display areas, being the property owner's product line. Therefore, staff
finds that the parking to be provided is in compliance with the
requirements of the LUC, based on the breakdown of the proposed auto -
related uses.
Pedersen Auto Plaza, Project Development Plan, #26-97
March 19, 1998 P & Z Meeting
Page 7
Direct on -site access to pedestrian and bicycle destinations. The
development proposal satisfies the standard [Section 3.2.2(C)(6) that the on -site
pedestrian and bicycle circulation system must be designed to provide, or allow
for, direct connections to major pedestrian and bicycle destinations including, but
not limited to, parks, schools, neghborhood centers, neighborhood commercial
districts and transit stops that are located either within the development or
adjacent to the development as required, to the maximum extent feasible. The
on -site pedestrian and bicycle circulation system must provide, or allow for, on -
site connections to existing or planned off -site pedestrian and bicycle facilities at
points necessary to provide direct pedestrian and bicycle travel from the
development to similar major pedestrian destinations located within the
neighborhood. In order to provide direct pedestrian connections to these
destinations, addtional sidewalks or walkways not associated with a street, or the
extension of a sidewalk from the end of a cul-de-sac to another street or
walkway, may be reqired.
There is an identified multi -modal transportation corridor planned within the
exsting Burlington Northern Railroad right-of-way to the west of this site. Some
improvements to this corridor are planned to occur within approximately 8 years.
The City has requested that this- property owner dedicate a 12' wide access
easement along the south property line to accommodate a future 8' wide paved
trail for pedestrian and bicycle access to the corridor from South Mason Street
and the commercial corridor along Sout College Avenue. The subdivision plat,
Site Plan, and Landscape Plan do provide the necessary access easement to
enable the City to construct an 8' wide trail at some point in time in the future.
Setbacks. The 5' wide landscape setback requirement as set forth in Section
3.2.2(J) is not being met along the south property line because of the requested
12' wide pedestrian access easement to the future multi -modal transportation
corridor along the railroad tracks to the west (Sections 3.2.2(C)(6) and 3.6.4(B)J.
The applicant has submitted a request for approval of an alternative landscape
and tree protection plan that may be substituted for a landscape plan that would
meet the standards of this section of the LUC. This is in conformance with
Section 3.2.1(N) - Alternative Compliance, which allows the Planning and Zoning
Board to review and approve an alternative plan if it finds that the proposed
alternative plan accomplishes the purposes of this section equally well or better
than would a plan which complies with the standards of this section.
In reviewing the proposed alternative plan for purposes of determining whether it
accomplishes the purposes of this section as required, the Planning and Zoning
Pedersen Auto Plaza, Project Development Plan, #26-97
March 19, 1998 P & Z Meeting
Page 6
The trash enclosure and used oil container are attached to the building on the
west side, away from South Mason Street, and will be set back 200' to 225' from
the north and south property lines and adjacent non-residential uses. They will
be set back 115' from the west property line and 300' to 350' from the nearest
residential dwelling unit. The enclosures will be of a masonry material, with a
standing seam metal roof to match the large building, and will be screened from
adjacent properties by a combination of the large building and plant materials in
the parking lots and along the perimeter of the site.
Section 3.2.2. Access, Circulation and Parking,
The proposal satisfies the applicable Access, Circulation and Parking standards,
including the following:
Bicycle parking. Bicycle parking is provided on site that meets or exceeds the
required number of bicycle parking spaces, as well as the location, as defined in
the following standard fSection 3.2.2(C)(4)(a)l
A minimum number of bicycle parking spaces shall be provided, equal in
number to at least rive (5) percent of the total number of automobile
parking spaces provided by the development, but not less than one.
Two pad sites for the placement of bicycle racks, to accommodate 8 - 10
bicycles, are located near the front and rear entryways to the building. This
represents a minimum' of 6% of the total of 137 automobile parking spaces
(excluding the auto display/sales) on the site.
Directness and continuity of walkways. The development proposal satisfies
the standards (Sections 3.2.2(C)(5)(a)(b)] that walkways within the site shall be
located and aligned to directly and continuously connect areas or points of
pedestrian origin and destination, and shall not be located and aligned solely
based on the outline of a parking lot configuration that does not provide such
direct pedestrian access. Also, where it is necessary for the primary pedestrian
access to cross drive aisles or internal roadways, the pedestrian crossing shall
emphasize and place priority on pedestrian access and safety.
The development proposal provides for a sidewalk network that includes a
detached walkway along the minor arterial street. Primary pedestrian walkways
and driveway crossings will be provided from the detached sidewalk to the
building. The driveway,crossings will be defined with striping on the pavement to
differentiate them from the vehicular lanes.
Pedersen Auto Plaza, Project Development Plan, #26-97
March 19, 1998 P & Z Meeting
Page 5
Trees are being provided in the 15' wide perimeter setback along South Mason
Street, adjacent to the parking lot and behind the sidewalk, and integrated with
the streetscape in the street right-of-way are at a spacing of 25'. This meets the
standard for Parking Lot Perimeter Landscaping.
The second standard reference [Section 3.2.1(E)(4)(b)] states that:
Parking lots with 6 or more spaces shall be screened from adjacent uses
and from the street. Screening from the street and all non-residential uses
shall consist of a wall, fence, planter, earthen berm, plant material or a
combination of such elements, each of which shall have a minimum height
of 30". Such screening shall extend a minimum of 70%. of the length of the
street frontage of the parking lot and also 70% of the length of any
boundary of the parking lot that abuts any non-residential use. Plant
material used for the required screening shall achieve required opacity in
its winter seasonal condition within 3 years of construction of the vehicular
use area to be screened.
The screening for the South Mason Street frontage will consist of a combination
of earthen berms (1.5' high) and shrubs, totaling a minimum of 30" in height,
extending a minimum of 70% of the street frontage along the parking lots.
Screening along the north and west property lines will consist of a mix of
deciduous and evergreen shrubs meeting the requirements of the LUC.
Screening along the south property line will consist of a 6' high solid wood fence
meeting the requirements of the LUC.
The third standard referenced (Section 3.2.1(E)(5)] states that:
Six (6) percent of the interior space of all parking lots with less than 100
spaces, and ten (10) percent of the interior space of all parking lots with
100 spaces or more shall be landscape areas.
This development proposal meets or exceeds the standard for Parking Lot
Interior Landscaping, providing a minimum of 10% interior landscaping in the
auto display and sales area parking lots, and in the auto service and repair area
parking lots.
Screening. The proposal complies with the standard relating to the screening
(Section 3.2.1(E)(6)] of areas of low visual interest or visually intrusive site
elements (such as trash collection, open storage, service areas, loading docks,
and blank walls) from off -site view.
Pedersen Auto Plaza, Project Development Plan, #26-97
March 19, 1998 P & Z Meeting
Page 4
residence is 200' to 250' and includes the railroad tracks and the New Mercer Irrigation
Canal. It was determined that the impacts of this development on the adjacent
neighborhood could be mitigated through the physical separation and design of the
project and, therefore, a neighborhood meeting was not held.
3. ARTICLE 3 - GENERAL DEVELOPMENT STANDARDS
This PEDERSEN AUTO PLAZA, PDP proposal does not meet all of the applicable
standards in ARTICLE 3 - GENERAL DEVELOPMENT STANDARDS of the LUC.
There have been requests submitted for review for modifications to those standards
which have not been met. Of specific note are Division 3.2 - Site Planning and
Design Standards, Division 3.5 - Building Standards, Division 3.6 - Transportation
and Circulation. Further discussions of these particular standards follow.
A. Division 3.2 - Site Planning and Design Standards
Section 3.2.1. Landscaping and Tree Protection
The proposal satisfies the applicable Landscaping and Tree Protection standards,
including the following:
Street trees. The proposed street tree planting is in accordance with Section
3.2.1(D)(2)(a), providing trees at 30' to 40' on -center in the 5' wide parkway
(between curb and sidewalk) along South Mason Street, a 2-lane minor arterial
street.
Parking lot landscaping - perimeter and interior. Parking lot landscaping for
this project is in accordance with the standards, including those related to
Parking Lot Perimeter Landscaping (Section 3.2.1(E)(4)(a) and (b)]and Parking
Lot Interior Landscaping (Section 3.2.1(E)(5)].
The first standard referenced (Section 3.2.1(E)(4)(a)] states that:
Trees shall be provided at a ratio of one (1) tree per twenty-five (25) lineal
feet along a public street. Trees may be spaced irregularly in informal
groupings or be uniformly spaced, as consistent with larger overall
planting patterns and organization. Perimeter landscaping along a street
may be located in and should be integrated with the streetscape in the
street right-of-way.
Pedersen Auto Plaza, Project Development Plan, #26-97
March 19, 1998 P & Z Meeting
Page 3
existing auto service and repair facility located on the east side of South College
Avenue at the intersection of Troutman and JFK Parkways. This is an auto -oriented
facility in an area along South College Avenue that includes a number of auto
dealerships, auto maintenance and repair shops, and auto parts and supply stores. The
site has been designed to provide and emphasize safe and convenient pedestrian
movement from the Mason Street sidewalk system to the public entries into the facility
along the east side.
COMMENTS:
1. Background:
The surrounding zoning and land uses are as follows:
N: C; vacant
S: C; existing retail (United Building Center)
W: C, RL; existing residential, railroad and irrigation ditch corridors (Flagstone
Patio Homes PUD, Burlington Northern Railroad, New Mercer
Canal)
E: C; existing commercial/retail (South College Avenue retail corridor)
This property was annexed into the City as part of the Horsetooth-Harmony Annexation
in July, 1978.
The property was subdivided •as part of Tract "B" of the Fossil Creek Commercial Plaza
Subdivision, approved by City Council on November 6, 1978.
2. ARTICLE 2 - ADMINISTRATION
Section 2.2.2. Step 2: Neighborhood Meetings
The PEDERSEN AUTO PLAZA, PDP contains proposed land uses that are permitted
as Type II uses, subject to review by the Planning and Zoning Board. The proposed
uses are auto servicing, express tube services, auto body repair, auto parts storage,
retail parts sales, auto sales, and auto showroom. The LUC requires that a
neighborhood meeting be held for development proposals that are subject to Board
review unless the Director determines that the development proposal would not have
significant neighborhood impacts. The Current Planning Director and staff determined
that the proposed auto -related facility is in the community/regional shopping corridor
between South College Avenue and the Burlington Northern Railroad right-of-way, and
that the physical separation between the west side of this facility and the nearest
Pedersen Auto Plaza, Project Development Plan, #26-97
March 19, 1998 P & Z Meeting
Page 2
standards located in Division 3.2 - Site Planning and Design Standards,
Division 3.5 - Building Standards, Division 3.6 - Transportation and
Circulation of ARTICLE 3 - GENERAL DEVELOPMENT STANDARDS;
and the applicable district standards located in ARTICLE 4 - DISTRICT
STANDARDS of the LUC (Division 4.17 C - Commercial Zoning District).
The PDP does not comply with the following requirements of the LUC:
" standards located in Section 3.2.1(E)(4) - Parking Lot Perimeter
Landscaping, Section 3.2.2(J) - Setbacks of ARTICLE 3 - GENERAL
DEVELOPMENT STANDARDS. An alternative landscape plan, in accordance
with Alternative Compliance in the LUC, has been submitted for consideration.
standards located in Section 3.5.3(B)(2) - Relationship of Buildings to
Streets, Walkways and Parking (build -to line) of ARTICLE 3 - GENERAL
DEVELOPMENT STANDARDS. A request for a modification to the standards
has been submitted for consideration.
Vehicle major repair, servicing and maintenance establishments and vehicle sales and
leasing establishments with outdoor storage are permitted in the C - Commercial
Zoning District, subject to Planning and Zoning Board (Type II) review. The purpose of
the C - District is:
Intended to be a setting for development, redevelopment and infill of a wide
range of community and regional retail uses, offices and personal and business
services. Secondarily, it can accommodate a wide range of other uses including
creative forms of housing.
While some Commercial District areas may continue to meet the need for auto -
related and other auto -oriented uses, it is the City's intent that the Commercial
District emphasize safe and convenient personal mobility in many forms, with
planning and design that accommodates pedestrians.
This proposal complies with the purpose of the C - District as it provides community and
regional retail and ancillary uses in a community/regional shopping area of Fort Collins
(the South College Avenue corridor): The retail portion of the operation is the new auto
showroom, display, and sales. The ancillary uses are the auto servicing, express lube
services, auto body repair, auto parts storage, retail parts sales portions of the
operation, for both this facility and the existing Pedersen Toyota -Volvo -Saab facility
block to the east on Kensington Drive. This Pedersen facility would replace their
ITEM NO. 7
MEETING DATE 3 19/98
STAFF Steve Olt
Citv of Fort Collins PLANNING AND ZONING BOARD
STAFF REPORT
PROJECT: Pedersen Auto Plaza, Project Development Plan - #26-97
(Replat of a Portion of Tract B, Fossil Creek Commercial Plaza)
APPLICANT: Dana Lockwood
Lockwood Architects
420 South Howes Street, Suite 101 B
Fort Collins, Colorado 80521
OWNERS: Gerry and Jo Anne Pedersen
4455 South College Avenue
Fort Collins, CO. 80525
PROJECT DESCRIPTION:
This is a request for a Project Development Plan (PDP) for an auto related facility that
includes auto servicing, express lube services, auto body repair, auto parts storage,
retail parts sales, auto sales, and auto showroom. The property is located on the west
side of the South Mason Street at the northwest corner of the intersection of South
Mason Street and Kensington Drive, 500' west of South College Avenue, and 500' north
of West Harmony Road. The applicant proposes to construct one [predominantly] 2-
story building, with associated parking and auto display areas, on 3.51 acres. The total
floor area is approximately 30,000 square feet and [site] building coverage is
approximately 21,700 square feet. The property is in the C - Commercial Zoning
District.
RECOMMENDATION: Approval
EXECUTIVE SUMMARY:
This Project Development Plan complies with the applicable requirements of the Land
Use Code (LUC), more specifically:
the process located in Division 2.2 - Common Development Review
Procedures for Development Applications of ARTICLE 2 -
ADMINISTRATION;
COMMUNITY PLANNING AND ENVIRONMENTAL,SERVICES 281 N. College Ave. P.O. Box 580 Fort Collins, CO 80522-0580 (970) 221-6750
PLANNING DEPARTMENT