Stormwater:
1. The stubs need to be in a public easement.
2. label the storm drains on the utility plans.
Light 6 Power:
1. The large building should be master metered.
2. The gang meters should be at one location.
3. Services have to be in a utility easement with the multiple lots.
4. A utility coordination should be scheduled for this development
proposal.
Water/Wastewater:
1. Routing of water and sanitary sewer services (mostly water) on
individual lots is problematic.
2. There is a meter pit shown on the fire line but not on the domestic
water line. This appears to be a labeling problem.
3. The grease trap location is problematic.
4. A utility coordination should be scheduled for this development
proposal.
This completes staff (and outside reviewing agencies) review and comments at
this time. Additional comments and red -lined plans may be forthcoming. Another
round of staff review is determined to be necessary. This proposal is subject
to the 90-day revision re -submittal requirement (from the date of this
comment letter, being August 15, 2005) as set forth in Section 2.2.11(A)
of the Land Vse Code. Be sure and return all of your red -lined plans when you
Page 6
Number: 80 Created: 8/3/2005
[8/3/05] Correctly show the meter pit on the domestic service rather than on
the fire line.
Number: 81 Created: 8/3/2005
[8/3/05] See site, landscape and utility plans for other comments.
Topic: Utility Pons
Number: 32 Created: 2/25/2005
[8/3/05]
[4/12/05] Water mains within the city of Fort Collins Service area are to be
constructed with Ductile Iron Pipe. Clearly define this on the plan set.
[2/25/05] Water services may not be PVC from the main to a point 5 feet
downstream of the meter pit.
**********************************************************************
The following comments and concerns were expressed at the staff review
meeting on August 3, 2005:
Engineering:
1. City staff will need to see a new plat with the proposed lots for the
dwelling units in the cottage buildings. Staff suggests keeping the plat
the original way.
2. The reference to "by others" on the plans should be changed to be more
specific.
3. The proposed roof drain outside of an easement could be problematic.
4. A utility coordination should be scheduled for this development
proposal.
Page 5
Topic: Utility Pons
Number: 71 Created: 8/2/2005
[8/2/05] Please label all existing and proposed storm lines on the overall utility
plans.
Please make sure that the storm sewer stubs that are to be built by the
Northwest. Roads project are coordinated with JR Engineering, in order to make
sure the locations and elevations of these stubs match in both plan sets.
Department: Transportation Planning Issue Contact: David Averill
Topic: 6enerol
Number: 72 Created: 8/2/2005
[8/2/05] A minor comment -please refer to the revised walkway that leads
from the street sidewalk on Kansas. Where this walkway crosses the
north/south drive aisle the ramps should be directional, and not radial
(directing pedestrians into the main drive aisle) as shown. Refer to redlined
site plan for clarification. Thanks.
Department: Water Wastewater Issue Contact: Jeff Hill
Topic: 6entrol
Number: 75 Created: 8/3/2005
[8/3/05] Provide 10-feet separation between fire hydrants and water/sewer
services
Number: 76 Created: 8/3/2005
[8/3/05] Use tapping saddle rather than tees on existing water lines.
Number: 77 Created: 8/3/2005
[8/3/05] Indicate lengths of all D.I.P.
Number: 78 Created: 8/3/2005
[8/3/05] Label all cleanouts in traffic areas as traffic rated and provide the
standard detail on the detail sheet.
Number: 79 Created: 8/3/2005
[8/3/05] Provide access to the proposed grease trap location for cleaning.
Indicate sizes of all sanitary sewer services.
Page 4
Department: Light 6 Power Issue Contact: Monica Moore
Topic: General
Number: 70 Created: 7/18/2005
[7/18/05] Utility plan still shows the gas and electric meters sharing the same
wall of the building. Gas meters are to be located on one end of the building
and the electric meters are to be located on the opposite end. There will be
ONE location on each building where all the meters for the duplex units and all
the meters for the 3-plex units will all be ganged together. Please contact
Light and Power, at 221-6700, to coordinate this location.
Topic: Utility Plans
Number: 54 Created: 4/8/2005
[7/18/051
[4/8/05] Electric meters will be ganged at one end of the building or another -
NOT both ends. Contact Light and Power 221-6700 to coordinate location of
meters.
Department: Natural Resources
Topic: General
Number: 83
[8/4/05] No issues.
Issue Contact: Doug Moore
Created:8/4/2005
Department: Stormwater Utility Issue Contact: Basil Hamdan
Topic: Drainage Report
Number: 73 Created: 8/2/2005
[8/2/05] It was assumed that Basin 2 had an overall average overland flow
length of 650 ft, since Basin 2 is mostly roof area, it is not clear how this 650
ft overland flow length was arrived at.
Topic: Plat
Number: 74 Created: 8/2/2005
[8/2/05] Please show a utility and drainage easement for all areas where storm
sewers are stubbed into the site from surrounding streets.
Page 3
ti
Topic: Plot
Number: 87
Created:8/15/2005
[8/15/05] The Technical Services Department offered the following
comments:
a. The outside boundary and legal description do close.
b. All easements must be locatable.
c. Show different easements with different line types ... EAE S UE.
d. Subdivision name. It it the loth or 11th Filing?
Number: 88 Created: 8/15/2005
[8/15/05] Megan Harrity of the Larimer County Assessor's Office indicated
that the owner of record is as recorded for Parcel #87290-00-006 in Lorimer
County. The subdivision plot. does not specify the current owner.
Department: Engineering Issue Contact: Marc Virata
Topic: 5eneml
Number: 82 Created: 8/3/2005
[8/3/05] Please amend the "by others" indications on the construction plan set
to instead reference the appropriate plan set in which the work -to be done is
indicated.
Number: 84 Created: 8/5/2005
[8/5/05] Please move the storm drain roof line away from the typical 9' utility
easement width along Kansas Drive on the northeast area of the site.
Number: 85 Created: 8/5/2005
[8/5/05] With the apparent amending of the plat to provide individual lots for
the units, an additional round of review is required and a utility coordination
meeting is required.
Number: 86 Created: 8/5/2005
[8/5/05] I will not work on scheduling a utility coordination meeting until it is
confirmed that the project will be amended to provide individual lots for the
units. Please notify me of the outcome either way.
Page 2
STAFF PROJECT REVIEW
City of Fort Collins
Davis Partnership, Architects Date: 08/15/2005
c/o Lynn Moore, FASLA
2301 Blake St, Suite 100
Denver, CO 80205
Staff has reviewed your submittal for RIDDEN FARM, 10TH FILING,
SPECTRUM INDEPENDENT LIVING - FINAL PLANS, and we offer the
following comments:
ISSUES:
Department: Current Planning Ism Contact: Steve Olt
Topic: 6 WM1
Number: 89 Created: 8/15/2005
[8/15/05] Carl Jenkins of the U.S. Postal Service indicated that centralized
delivery, using a minimum of 1 centralized box unit (CBU, Type II), is required
for the duplex cottages and centralized apartment type boxes for the main
building. Revise the plan to show the required CBU location as approved by the
U.S. Postal Service. In all cases the CBU's must be located in the public right-
of-way or a designated easement. Please be advised that the responsibility of
purchase and maintaining the CBU's with concrete pads is that of the
owner/developer/ HOA. Prior to occupancy within the development appooved
mail receptacles must be in place. A delivery agreement must be in place prior
to any delivery of mail. Contact Carl Jenkins, Growth Coordinator, U.S. Postal
Service, 301 Boardwalk Drive, Fort Collins, CO., phone #(970)225-4130, cell
#(970)214-3668,fax #(970)225-4139.
Number: 90 Created: 8/15/2005
[8/15/05] It appears that the biggest outstanding issue is with regards to the
developer's proposal to create individual lost for each of the dwelling units in
the 4 cottage buildings. This could have significant impacts on provision. of
utilities. Because of this, another round of development review is absolutely
necessary.
Page 1