Loading...
HomeMy WebLinkAboutRIGDEN FARM, FILING ONE, REPLAT OF LOT M1 - PDP - 56-98X - CORRESPONDENCE - (5)If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at 221-6341. Yours Truly, 5f eve Olt City Planner cc: Sheri Wamhoff Current Planning File #56-98X Page 4 Department: -Water Wastewater Issue Contact: Jeff Hill Topic: 6enerol Number: 9 Created: 3/18/2004 [3/18/04] Provide separate water and sewer services for each individual lot per Municipal code 26-256. Department: Zoning Issue Contact: Jenny Nuckols Topic: ZONING Number: 1 Created: 3/4/2004 [3/4/04] No Comments. The following comments / concerns were expressed at staff review on March 17, 2003: Engineering: 1. A Sight Distance easement is needed on the subdivision plat. 2. Some of the text on the subdivision plat is too small. It is difficult to read and will not reproduce well. Water/Wastewater: 1. Presently, water and sanitary sewer services come into Lot 2 to service both lots. Separate services may be necessary for each lot, dwelling unit. This completes staff (and outside reviewing agencies) review and comments at this time. Additional comments and red -lined plans may be forthcoming. Another round of staff review is determined to be necessary. This proposal is subject to the 90-day revision re -submittal requirement (from the date of this comment letter, being March 23, 2004) as set forth in Section 2.2.11(A) of the Land Use Code. Be sure and return all of your red -lined plans when you re -submit The number of copies of each document to re -submit is shown on the attached Revisions Routing Sheet. Page 3 0 0 Number: 5 Created: 3/16/2004 [3/16/04] Technical Services had the following comments: 1. Boundary Closes 2. Easement text is too small. 3. Plat needs standard city notes about restrictions in sight easement. Department: Light & Power Issue Contact: Monica Moore Topic: ZONING Number: 2 Created: 3/5/2004 [3/5/04] If electric service is installed as shown on utility plan with 1 service split into two meters, there will be no additional development charges. Department: Natural Resources Topic: Genera/ Number: 8 [3/17/04] No issues. Issue Contact: Doug Moore Created:3/17/2004 Department: PFA Issue Contact: Michael Chavez Topic: General Number: 6 Created: 3/16/2004 [3/16/04] Address numerals shall be visible from the street fronting the property, and posted with a minimum 6 inch numerals on a contrasting background. Number: 7 Created: 3/16/2004 [3/16/041 No commercial building can be greater then 300 feet from a fire hydrant. Each hydrant shall be capable or delivering 1,500 gallons per minute, with a residual pressure of 20 pounds per square inch. Department: Police Topic: General Number: 3 [3/10/04] No comments. Department: Stormwater Utility Topic: General Number: 10 [3/19/04] No Comments. Issue Contact: Joseph Gerdom Created:3/10/2004 Issue Contact: Basil Hamdan Created:3/19/2004 Page 2 e 6aSTAFF PROJECT REVIEW City of Fort Collins Robert Smith Construction, Inc. Date: 03/23/2004 c/o Robert Smith 7830 Eagle Ranch Road Fort Collins, CO. 80528 Staff has reviewed your submittal for RIGDEN FARM, 1ST FILING, REPLAT OF LOT M1 - TYPE I (LUC), and we offer the following comments: ISSUES: Department: Current Planning Topic: 6enerai Issue Contact: Steve Olt Number: 11 Created: 3/23/2004 [3/23/04] QWEST has indicated that, as a replat of the lot, the builder needs to provide 2" conduit for service props from the pedestal at the east property line (at the northwest corner of 2950 Des Moines Drive). Homeowners will not have service unless the builder provides conduit per modified P.U.C. tariff. Number: 12 Created: 3/23/2004 [3/23/04] Rick Lee of the Building Department indicated that there are no outstanding building code concerns at this time. The construction is currently regulated under the 1997 Uniform Building Code. Number: 13 Created: 3/23/2004 [3/23/04] The Technical Services Department offered the following comments: a. The easement text is too small. b. The subdivision plat needs the standard City note about restrictions in the Sight Easement. C. The Site Plan has problems with lines and text. Most text is too small or printed with too bold of line. It is very difficult to distinguish line types. d. The Landscape Plan is at too small of a scale to scan or print well. Department Engineering Issue Contact: Sheri Wamhoff Topic: Genera/ Number: 4 Created: 3/16/2004 (3/16/04] Need to add sight distance easement language to the plat. Page l