HomeMy WebLinkAboutLIBERTY FARMS - PDP - 31-06A - CORRESPONDENCE - (10)Number: 85 Created: 9/15/2007 [9/15/07] The reverse curves used in the northwest corner of the Rbt need to be revised to eliminate the curve C12 (as shown on pg 2 of the Plat). Vehicles do not follow a path such as the curb is shown. They will straighten it out. It becomes excess pavement collecting trash and debris. While this curve will not be necessary for vehicles entering the roundabout from the north, it will be necessary for vehicles navigating the circle from the south or east. Number: 86 Created: 9/15/2007 [9/15/07] Please provide fastest path info indicating the expected circulating speed of the Rbt. We will submit our calculations for the roundabout design separately. This information probably should not be included on the construction plans. Be sure and return all of your redlined plans when you re -submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at (970) 221-6750. Sincerely, Shelby Sommer Associate City Planner Page 16 This information is now on the plans. Number: 68 Created: 8/31 /2007 [8/31/07] Provide 10 feet of separation between City 24" water main and proposed 12" water main in Timberline. The waterline has been moved to the other side of the street. Number: 69 Created: 8/31 /2007 [8/31/071 Show all utility crossings in profile of 12" water main. The waterline profile has been updated. Department: Zoning Issue Contact: Gary Lopez Topic: Zoning Number: 6 Created: 8/23/2007 [8/23/07] No comments ISSUES: Department: Traffic Operations Issue Contact: Ward Stanford Topic: Traffic Number: 80 Created: 9/15/2007 [9/15/07] Per LCUASS Fig 8-1, a southbound left turn lane must be provided on Timberline. Understood. Please refer to traffic study memorandum included with resubmittal. Number: 81 Created: 9/15/2007 [9/15/07] On sheet 2 of the Plat, Dickerson Rd is stated as 57' ROW, but drawn as an 84' ROW. Please correct labeling. Revised. Number: 82 Created: 9/15/2007 [9/15/07] What were the growth factors used in the TIS? What other TIS's were used in the evaluation of this project? Please refer to traffic study memorandum included with resubmittal. Number: 83 Created: 9/15/2007 [9/15/07] Why were Lost Time adjustments used? Why was the called PHF not used in the analysis? Please refer to traffic study memorandum included with resubmittal. Number: 84 Created: 9/15/2007 [9/15/07] Need to provide all LCUASS data for mini -roundabouts, plus full dimensions of interior island, truck apron, inscribed radius, lane widths (circulating and approach), ped crossing widths, splitter island, landscaping in and around Rbt, and any other pertinent design data. . The roundabout is now detailed on the horizontal control plan Page 15 [8/29/07] ROUNDABOUT VEGETATION/LANDSCAPING: Please use landscaping that will not exceed 42 inches in height (with the exception of canopy trees). Understood. Appropriate changes have been made. Number: 70 Created: 8/31 /2007 [8/31/07] STREET NAME: The proposed Dickerson cannot be allowed because it's too close to the existing Didrickson. Dickerson Road has been renamed to Collamer Road. Department: Stormwater-Water-Wastewaterlssue Contact: Basil Hamdan. Topic: Ditch crossing Number: 53 Created: 8/28/2007 [8/28/07] Ditch crossing agreements need to be obtained from the ditch company at final. Verified with Mayer Sommermeyer that this is a common request they support- there is a standard agreement that is used. Topic: Grading Plan Number: 50 Created: 8/28/2007 [8/28/07] Grading Plan is preliminary in nature; more details are needed at final. Understood. Topic: Master Planned Improvements Number: 52 Created: 8/28/2007 [8/28/07] The site needs to accommodate a 247 cfs flow from the Cooper Slough basin into the Dry Creek basin. At this point all we are looking for is to reserve the right of way to pass this flow. The historic spill from the ditch does not affect this site. The site needs to reserve a minimum of 15 foot easement for a future drainage channel along the east property line. A 20' drainage easement was provided on the east property line. Preliminary design of the overflow channel was included in the drainage report. Topic: Off -site storm Number: 51 Created: 8/28/2007 [8/28/07], Please provide detailed design at final showing location and capacity of outfall swale. The off -site storm discharges into a swale provided by WaterFeld P.U.D. Additional information can be included in the final drainage report. Department: Stormwater-Water-Wastewaterlssue Contact: Roger Buffington Topic: WaterMastewater Number: 67 Created: 8/31 /2007 [8/31/07] Label size and owner of each water main in Timberline. Page 14 diagonal of the property).. All structures beyond the 660-foot limit shall be fire sprinklered if a second point of access cannot be provided. FCLUC 3.6.2(B)(C);3.6.6(I); 97UFC 902.2.2.3 Understood. A modification of standards request for the dead end turn arounds on Collamer Road south of the round about and Cherryhurst Road east of the round about is included with this resubmittal. Number: 57 Created: 8/29/2007 [8/29/071 FIRE LANE TO TIMBERLINE: Does this Emergency Access Eaesment extend all the way to Timberline Road? Also, does the EAE meet our turning radius requirement? Per discussion with city staff September 6 and followup, it has been determined with PFA that the two emergency access roads are not required on lots 1-3. All EAEs have been verified to meet turning radius requirements. Horizontal control plans and the plat indicate the dimensions of these easements. Number: 58 Created: 8/29/2007 [8/29/07] EAST FIRE LANE: What is the purpose of the east fire lane? Per discussion with city staff September 6 and followup, it has been determined with PFA that the two emergency access roads are not required on lots 1-3. Number: 59 Created: 8/29/2007 [8/29/07] ADDRESSING: Building 2 should be addressed off Cherryhurst Road. Understood. Number: 60 Created: 8/29/2007 [8/29/07] FIRE DEPARTMENT CONNECTION: Fire department connections shall be installed remote from the buildings, and located on the street or fire lane side of buildings, fully visible and recognizable from the street or nearest point of fire department vehicle access or as otherwise approved by the fire code official. If possible, a fire hydrant shall be located within 100 feet of the FDC. 2006 International Fire Code 912.2.1 and PFA Bureau Policy Acknowledged. Fire lines are currently shown for each building and fire department connections will be better established at final when floor plans are developed for each building. Number: 61 Created: 8/29/2007 [8/29/07] FIRE HYDRANT RELOCATION: Please move the fire hydrant shown at Timberline on the north side of Cherryhurst, directly south so it's on the south side of Cherryhurst. The fire hydrant has been moved. Number: 62 Created: 8/29/2007 Page 13 Topic: Landscape Plan Number: 1 Created: 8/15/2007 [8/15/07] A landscape plan showing locations of planned street lights has been sent to Vignette Studios showing planned streetlights. These lights will need to be shown on the landscape plan, and street tree locations adjusted to provide a minimum of 40 feet of clearance between the lights and the trees (15 feet if the tree is an ornamental type). The planned street lights have been added to the plans, with appropriate modifications to the landscape plan made to accommodate spacing. Department: PFA Issue Contact: Carie Dann Topic: Fire Number: 54 Created: 8/29/2007 [8/29/07] WATER SUPPLY: Fire hydrants, where required, must be the type approved by the water district having jurisdiction and the Fire Department. Hydrant spacing and water flow must meet minimum requirements based on type of occupancy. Minimum flow and spacing requirements include: Commercial, 1,500 gpm at 20 psi residual pressure, spaced not further than 300 feet to the building, on 600-foot centers thereafter; residential within Urban Growth Area, 1,000 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter; residential outside Urban Growth Area, 500 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter. These requirements may be modified if buildings are equipped with automatic fire sprinkler systems. 97UFC 901.2.2.2 Acknowledges. The buildings will be equipped with automatic fire sprinkler systems given their size. Fire hydrants have been provided to meet the -spacing requirements listed. Number: 55 Created: 8/29/2007 [8/29/07] CUL-DE-SAC: The cul-de-sacs are required to have a turnaround with a minimum diameter of 100 feet. There are no cul-de-sacs included in this site design. A modification of standards request for the dead end turn arounds on Collamer Road south of the round about and Cherryhurst Road east of the round about is included with this resubmittal. Number: 56 Created: 8/29/2007 [8/29/07] CUL-DE-SAC: A dead-end street cannot exceed six -hundred -sixty (660) feet in length. The turn -around at the end of the street must have an outside turning radius of fifty (50) feet or more, and an inside turning radius of twenty-five (25) feet. Short fire lanes are permitted to facilitate a second point of access when the street is longer than 660 feet. Separation of the access points at the minimum must meet the Rule of Remoteness (one-half the length of the Page 12 Topic: Technical services Number: 73 Created: 8/31/2007 [8/31/07] Show property ownership to the north - Weld, Larimer Canal ? The owner of the ditch is now shown on the plat. Number: 74 Created: 8/31/2007 (8/31/07] Conflict with Dickerson Rd. - please discuss with JR Wilson. Dickerson Road has been renamed to Collamer Road. Number: 75 Created: 8/31/2007 [8/31/07] Add street names to the vicinity map. The vicinity map has been revised. Number: 76 Created: 8/31/2007 (8/31/07] What are the two Book & Page areas near the NW corner? In the ROW. These are easements and are now more clearly shown on the plat. Number: 77 Created: 8/31/2007 [8/31/07] Who is the access easement dedicated to (85060800) ? Can it be vacated by this Plat? Please verify. This easement is being vacated by this plat. Number: 78 Created: 8/31/2007 [8/31/071 See redlines for additional minor comments. Acknowledged. Department: Light & Power Issue Contact: Doug Martine Topic: Electric Utility Number: 2 Created: 8/15/2007 [8/15/071 The developer will need to coordinate the power needs for each building and a location for the electrical transformers with Light & Power Engineering. Note that transformers must have a minimum of 3 feet of clearance on 3 sides to any wall, structure or fence, and 8 feet of clearance in front. Also, transformers must be located within 10 feet of an all-weather surface accessible to electric utility line trucks. This detail will be provided as part of initial final submittal. Number: 3 Created: 8/15/2007 [8/15/07] The source of power to this site will be the existing electric vault on the west side of Timberline, south of this site. The developer may be required to provide off -site easements and/or permits as necessary to bring power to this site. The existing transformer is within the existing right of way on the west side of Timberline. 70.5 feet of right of way was dedicated with the Waterfield P.U.D. Page 11 Number:41 . Created: 8/28/2007 [8/28/07] Please provide a standard City signature approval block in the lower right hand corner of all sheets. Because of the scale and shape of the development it was not possible to provide the signature block in this location on every sheet. / understand this request, but cannot find that this is a hard requirement. Number: 42 Created: 8/28/2007 [8/28/07] How will the future canal crossing be constructed ? The prelim. Off - site design just shows the road going over the canal at grade. More detail for the crossing has been provided on the revised utility plans. Number: 43 Created: 8/28/2007 [8/28/07] Provide intersection details on sheet 23 for T-intersection with Timberline and mini roundabout per LCUASS 7-27,8-13,8-14 and 8-15. More detailed information is now on the intersection details. Number: 44 Created: 8/28/2007 [8/28/07] Complete construction details will be required at the final compliance stage. Acknowledged. Number: 45 Created: 8/28/2007 [8/28/07] See redlines for additional minor comments. Return redlines with your next submittal. All changes to the Utility drawings must also be reflected on the Site and Landscape plans. Acknowledged. Number: 71 Created: 8/31 /2007 [8/31/07] As discussed at the staff review meeting, some street stubs may be shortened and money escrowed for future construction to avoid building turn- arounds. Detailed engineered cost estimates will be required for review.of those portions of streets not constructed. Full design is still required and off -site preliminary design as well. Full street design is being provided, but the revised plans are proposing paving dead ends at a later date. Type 3 barricades are provided just after the drive entrances. Since the tracts provide access easements for the lots, they will allow the public to utilize the parking areas as turn around areas. Number: 72 Created: 8/31 /2007 [8/31/07] Please consult with JR in Technical services regarding street naming conflicts. Dickerson Road has been renamed to Collamer Road. Page 10 [8/27/07) Offsite Sewer - Show, label and dimension the off -site easement for the proposed sewer on Timberline. Clearly show the R.O.W. limits on the plan view. A letter of intent or signed deed of dedication must be received for the easement prior to scheduling a public hearing. The offsite sewer is located within the right of way of Timberline road, no easement is necessary. Number: 35 Created: 8/27/2007 [8/27/07] No profile information was provided for the sewer, storm drains and water mains proposed. Will be reviewed with the next submittal. Profiles are now provided for all of the necessary utilities. Number: 36 Created: 8/27/2007 [8/27/07] Sheets 15 & 16 were not included in the plan set for the Timberline design. Need to provide any interim and ultimate design information with cross sections every 50 feet and a preliminary off -site design for 1000 feet in both directions. These sheets are provided in the current set. Number: 37 Created: 8/27/2007 [8/27/07] Please provide an intersection detail for the intersection of Cherryhurst and Timberline. Show all dimensions and elevations per LCUASS 7-27. An intersection detail sheet has been provided with this information Number: 38 Created: 8/28/2007 [8/28/07] Call out all standard driveways, sidewalks, pedestrian ramps and curb & gutter on the street design plans (Typ.) Acknowledged Number: 39 Created: 8/28/2007 [8/28/07] LCUASS standards do not allow single point grade breaks to exceed 0.4% algebraic grade difference. Please provide vertical curves or additional grade breaks at these locations. See redlines - street design profiles for clarification. Add slope and elevation information where needed per the redlines. All proposed street grades must tie back into existing grades. Please show locations of proposed inlets at low points on the profile. Profiles have been revised. Number: 40 Created: 8/28/2007 [8/28/07] Arterial cross sections - please provide the following information on at least one cross section (labeled typ.): Dimensions, ROW limits, pavement cross slopes, max side slopes 4:1 max. All proposed grades must be shown tying back into existing grades in the cross sections. Any grading outside the ROW limits may require an easement for road construction (i.e. slope easement). Additional information has been provided. Page 9 street name must be selected from an approved list of street names. Please contact JR Wilson in Technical Services for approved street names. Acknowledged. Number: 28 Created: 8/27/2007 [8/27/07] Plat - Please hatch fill the new ROW dedication area. The separation distance from the centerline of Timberline to the centerline of the private drive access on Cherryhurst must be no less than 460 feet. The Plat shows a separation of only 400 feet. Please revise or submit a variance request with justification. Will the private drives be named? Please consult with PFA for naming and addressing on private drives. Per September 6 staff review, given the site constraints staff agreed to allow an engineering variance to the private drive spacing on Cherryhurst. In addition, it was agreed that all buildings can be addressed off either Cherryhurst Road or Collamer Road. As a result the private drives will not be named. Number: 29 Created: 8/27/2007 [8/27/07] Please fix line over text and labeling throughout the plan set to comply with the LCUASS Appendix E scannability requirements. See redlines for clarification. Done. Number: 30 Created: 8/27/2007 [8/27/07] Please show all proposed limits of street cuts needed for utility work and add the standard street cut note provided where applicable. See redlines for clarification. Additional street cuts are shown with the applicable notes Number: 31 Created: 8/27/2007 [8/27/071 Grading - Please provide adequate spot elevations on the grading plans to check drainage with arrows showing surface drainage patterns. Additional information has been added to the plans. Number: 32 Created: 8/27/2007 [8/27/07] Grading - Some drainage is being directed to low spots where water will pond. Please see redlines for clarification. Additional information has been added to the plans. Number: 33 Created: 8/27/2007 [8/27/07] Grading - Label topo lines with elevations and call out all inflow/outflow gutters and curb openings. Details must be provided at the final compliance stage. Additional information has been added to the plans. Number: 34 Created: 8/27/2007 Page 8 Aknowledged. The plans have been revised and updated to include additional information. Number: 23 Created: 8/27/2007 [8/27/07] Please provide review comments from Boxelder Sanitation and Elco Water District with your next submittal. It was understood that the City forwarded plans to the appropriate agencies. Since this was not the case, these agencies are reviewing the revised plans and we will submit review comments when they are received from them. Number: 24 Created: 8/27/2007 [8/27/07] Plat Cover Sheet - Please provide a different vicinity map that shows one -line named streets and project location without shading and topography. The vicinity map will not scan well and does not comply with LCUASS Appendix E. The vicinity map has been revised. Number: 25 Created: 8/27/2007 [8/27/07] The proposed street layout does not comply with section 3.6.3.f for street stub connections at no more than 660 feet measured along the project boundary to developable parcels. Please provide a street stub connection every 660 feet or request for modification based on justification. Per September 6 staff review, two pedestrian connections are provided from the developments pedestrian network to the property to the south. Given the Larimer and Weld Canal on the north, it was agreed that no additional connections are required on the north other than provisions for extension of Collamer Road when the adjacent north property is developed. Number: 26 Created: 8/27/2007 [8/27/07] The proposed street stub connections do not comply with City Land Use Code Section 3.6.6.D.4.f.2 for dead ends. No dead end may exceed 660. feet without standard cul-de-sac turn arounds provided. Please also see comments from PFA for access and dead end lengths. Decision has been made that we are not required to build extension/turn around for Collamer beyond the north edge of round about, given the length of the dead end is less than 150' A modification of standards is included with this resubmittal to address the dead-end created for Cherryhurst Road east of the round about and Collamer Road south of the round about. Number: 27 Created: 8/27/2007 [8/27/07] Plat - Dickerson at the canal crossing is mislabeled as 57 feet of ROW. Should be changed to 84 feet. Dickerson will be an arterial and the Page 7 Number:14 . Created:8/27/2007 [8/27/07] Is there any fencing proposed? What about trash enclosures? Please identify on site plan and provide elevations. Location of and detail for fencing and trash enclosures has been provided. Number: 46 Created: 8/28/2007 [8/28/07] Per Section 3.5.3 Variation in Massing of buildings is required. Horizontal masses shall not exceed a height:width ratio of 1:3 without substantial variation in massing that includes a change in height and a projecting or recessed elements. The Rectangular and V Shaped Building types are especially problematic and need more variation in the large horizontal massing, but all of the elevations could use some work. Additional detail has been provided for the elevations. Department: Current Planning Issue Contact: Dana Leavitt Topic: Site Plan Number: 63 Created: 8/29/2007 [8/29/07] Natural Area buffer,for the canal is not being met. During a site visit in June, it was agreed that an average 50' buffer would be appropriate. With the inclusion of two emergency access drives located within the buffer, this approach will need to be re-evaluated. Per the September 6 review with city staff, several changes have been made. The emergency access roads have been removed from the plan per agreement with PFA. Further, the parking area on the northwest portion of site has been modified to maintain at least a 25' minimum buffer, with an average buffer exceeding 50'. Department: Current Planning Issue Contact: Shelby Sommer Topic: Technical services Number: 79 Created: 9/4/2007 [9/4/07] Although the street names were selected from the approved street name list for Arterial/Collector streets, Dickerson is too similar to other street names in use. Please select another name from the approved street name list and then we will cross-reference it with the existing names to make sure there isn't another conflict. Thanks. Dickerson Road has been renamed to Collamer Road. Department: Engineering Issue Contact: Randy Maizland Topic: Engineering Number: 22 Created: 8/27/2007 [8/27/07] The Utility Plan set is incomplete. Review comments are only as complete as the information provided. No street design plans were included for Timberline Road. Several plan and profile sheets do not have a profile design provided. Page 6 this is a step in the right direction, it appears that patios have been proposed on each building that does not meet the requirement as a means to avoid the standard. In order for this alternative to be considered you'll need to provide information as to how these patios add pedestrian interest, comfort and visual continuity along the sidewalk. At this stage I don't see how these patios are an acceptable alternative to the build -to standard. Per discussion with city staff September 6, the buildings on the south portion of the development have been reconfigured to face Collamer Road, in response to this concern. Number: 12 Created: 8/27/2007 [8/27/07] The majority of the proposed buildings have footprints greater than 10,000 square feet. Per Division 4.5(E)(2)(1) for any building with a footprint in excess of 10,000 sq. ft., walls that are greater than 75 feet in length shall incorporate recesses or projections created by wall plane returns of at least 30 feet; any such building shall be differentiated into multiple sections of mass in order to achieve proportions that are compatible in scale with adjacent residential neighborhoods. Please revise plans so that walls over 75 feet in length are recessed/projected as specified in this section. The building elevations appear to do this, but it is not clear on the site plan if you are actually satisfying this standard. Additional detail has been provided for the building elevations and the site plan building footprints to meet the building standards. Number: 48 Created: 8/28/2007 [8/28/07] Please clearly define the small neighborhood park area on the site plan. The location of the park should be a highly visible area formed by the street layout and pattern of lots and easily observed from streets. As proposed, the park does not accomplish this standard as it is not visible from any street, with the exception of Timberline. Please see Division 4.5(D)(6) for Small Neighborhood Park standards. The site design has been modified to make the park more visible from Cherryhurst Road. These changes include re -orientation of the Lot 8 building and modification of the parking and pedestrian paths on the north side of the park. Topic: Building Elevations Number: 13 Created: 8/27/2007 [8/27/07] The base treatments on the buildings need to be a little more recognizable and defined. For "L" and Building Type 1 it appears to be cultured stone, but for the "Rectangular" and ' V" shaped building, there is no defined base treatment - the cultured stone actually extends all the way up to the second floor in some areas. Also, please label the maximum building height on the elevations. Additional detail has been provided for the elevations. Page 5 Landscape material size and species will be specified in final plans. Department: Current Planning Issue Contact: Shelby Sommer Topic: Lighting Plan Number: 15 Created: 8/27/2007 [8/27/07] FYI - "Tracts" is misspelled on the lighting plan statistics table. Otherwise, lighting plan looks fine. This has been corrected. The plan was updated to the new site plan. Department: Current Planning Issue Contact: Dana Leavitt Topic: Plat Number: 65 Created: 8/29/2007 [8/29/07] A note will be required on the plat explaining the allowable uses within the natural area buffer zone. The following note has been added to the plat. "Allowable uses within the natural area buffer zone Latimer and Weld Canal are defined by Fort Collins Land Use Code 3.4.1(e)." Department: Current Planning Issue Contact: Shelby Sommer Topic: Site Plan Number: 8 Created: 8/27/2007 [8/27/07] Please clearly identify which buildings/units will be used for Independent Living facilities. Per the definition of Independent Living in the Land Use Code, such facilities must occupy no more than 25 percent of the total GROSS AREA of a long-term care development. Please include calculations confirming the total gross area of the independent living facility with respect to the total gross site area of the whole development. Per discussions with Shelby Sommer and Peter Barnes, it was determined the 25% calculation can be based either on total gross area or total floor space. Given the mix of uses and difficulty in specifying the specific gross area attributable to the independent living uses, it was decided to use floor space as the basis for this determination. Number: 9 Created: 8/27/2007 [8/27/07] Please include lot sizes on the site plan in addition to the floor area estimates. Done. Number: 10 Created: 8/27/2007 [8/27/07] Please show adjacent property uses on the site plan. Adjacent property uses and zoning provided. Number: 11 Created: 8/27/2007 [8/27/07] As stated in the Conceptual Review letter, this proposal does not satisfy the "build -to" line requirements in Section 3.5.3(B)(2). The response says that patios have been provided as a means to meet this standard. While Page 4 Department: Current Planning, Issue Contact: Shelby Sommer Topic: Landscape Plan Number: 16 Created: 8/27/2007 [8/27/07] Please include size and species of each landscape item. Landscape material size and species will be specified in final plans. Number: 17 Created: 8/27/2007 [8/27/071 Please show proposed landscape treatment for all areas not covered by buildings, parking, etc. including the park area (turf?), setback areas.... Hatching has been added to identify turf and shrub areas. Detailed specification will be provided in final plans. Number: 18 Created: 8/27/2007 [8/27/07] Foundation plantings are required along high visibility/use areas of buildings. Hatching has been added to identify turf and shrub areas. Detailed specification will be provided in final plans. Number: 19 Created: 8/27/2007 [8/27/07] The parking lot west of Tract C does not appear to feature any interior landscaping - 6% interior landscaping is required. Per discussion with city staff September 6, it was determined this parking lot does meet the intent of interior landscaping. Measuring the parking lot as being 63 feet wide (as measured between back of head -in parking curbs) and 131 feet in length (measured from back of curb on north side to back of street walk on south side) total parking area. is 8,253 square feet. The four landscape areas in each corner of lot are 1,192 square feet, resulting in landscaping in 14.4% of parking lot. Number: 20 Created: 8/27/2007 [8/27/07] Parking bays shall extend no more than 15 parking spaces without an intervening landscape island. Please see redlines for problem area(s). Plan has been modified as requested. Number: 21 Created: 8/27/2007 [8/27/07] Please clearly identify the locations, species, size and condition of all significant existing trees, each with your intent to remove, transplant or protect. Add tree protection specification notes to the landscape plan so that existing trees will be protected appropriately. A plan sheet has been added containing this information. Department: Current Planning Topic: Landscape Plan Number: 64 [8/29/07] Provide a plant list. natural area buffer. Issue Contact: Dana Leavitt Created: 8/29/2007 Native plant species will be required within the Page 3 1. There must be maintained a maintenance and operation road on the south side of the ditch (the low side) that is at least 25 feet wide from the edge of the ditch perpendicularly measured out. In scaling off the drawings it appears to me that along a portion of the northeasterly corner of this subdivision, primarily along Tract C and a portion of Lot 4 that the access road has not been provided at a width of 25 feet. Per phone conversation September 20 with Mayo Sommermeyer, current plan is acceptable as long as buildings and/or improvements do not encroach into the 25 feet access road buffer measured from top of ditch. It is acceptable for lot lines to encroach upon the 25' access road buffer. The current road will not be improved by the ditch company. -2. There should be some type of fencing along the northerly boundary.of the subdivision to keep out or discourage people from the subdivision from accessing the ditch maintenance road and the irrigation ditch. The ditch at that point is quite wide and carries a large amount of water. If a person or animal were to find themselves in the ditch when we are running a full ditch it is likely they may not survive. A fence also keeps the ditch bank and the ditch shelf from being a depository for unwanted personal items or yard refuse. Per review. with Dana Leavitt, a 4 foot high rail fence with wire mesh is provided along Larimer and Weld Canal border. This requirement was discussed with Mayo Sommermeyer and received his verbal approval. By way of caution, the developer should be aware of the fact that there is probably some degree of "seep" from this ditch when it is running. There are many areas along the ditch where there is significant seep, which may have an effect on how foundations, barrier walls, and other construction details are approached and handles. It will be recommended by me that the developer confer with our ditch superintendent, Mr. Bill Johnson, at 222-0090 to determine what seep history there may be in that area. Acknowledged. . Number: 47 Created: 8/28/2007 [8/28/07] The following departments/agencies have no concerns with this proposal: Water Conservation, Park Planning, GIS, Real Estate Services, Comcast Thanks! Department: Current Planning Issue Contact: Dana Leavitt Topic: Grading Plan Number: 66 Created: 8/29/2007 [8/29/071 Add Tree Protection notes to the plan. Tree protection notes have been added. Page 2 STAFF PROJECT REVIEW City of Fort Collins Response to LIBERTY FARMS PDP — TYPE II comments embedded. DON TILLER Date: 09/04/2007. VIGNETTE STUDIOS 144 N MASON ST STE 2 FT COLLINS, CO 80524 Staff has reviewed your submittal for LIBERTY FARMS PDP - TYPE II, and we offer the following comments: ISSUES: Department: Advance Planning Topic: Site Plan Number: 49 [8/28/07] No comments. Issue Contact: Pete Wray Created: 8/28/2007 Department: Current Planning Issue Contact: Shelby Sommer Topic: General Number: 4 Created: 8/23/2007 [8/23/07] Please see the attached Building Codes and Standards that will apply to this proposal. Please schedule the required pre -submittal meeting as noted. Understood. Pre -submittal meeting will be scheduled prior to building permit application. Number: 5 Created: 8/23/2007 [8/23/07] Bonnie Ham (Growth Coordinator - US Postal Service): Developer must provide mailboxes for residents receiving mail directly. The location, number and type of mailboxes is negotiable. Please contact Bonnie at 301 E. Boardwalk, Fort Collins, CO 80525 or bonnie.j.ham@usps.gov for more information. Per guidance provided by Bonnie Ham, the mail delivery will be provided to a central building mail room. This will eliminate the need for change in address as residents move within the facility as their needs dictate. Number: 7 Created: 8/27/2007 [8/27/07] Mayo Sommermeyer (Representing Larimer and Weld Canal): I am general counsel for the Laimer and Weld Irrigation Company. I have reviewed the submissions of August 8, 2007 with the accompanying project comments sheet. Our major supply ditch, the Laimer and Weld Canal, runs on the northern boundary of this subdivision. We have two major concerns: Page 1