HomeMy WebLinkAboutTALON ESTATES - PDP - 42-05A - CORRESPONDENCE - (8),a REVISION City of Fort Collins COMMENT SHEET Current Planning DATE: March 141 2007 TO: Technical Services PROJECT PLANNER: Steve Olt #42-05A TALON ESTATES PDP — TYPE I Please return all comments to the project planner no later than the staff review meeting: March 28, 2007 Note -.Please identify Your redlines for future reference I . e'-U P V'A4_' r � LE6 AL C 10SE, ❑ No Problems ❑ Problems or Concerns (see below, attached, or DMS) 01 TYE /Z co /J ff (106,41) "C m / 31 Name (ple print) CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS _Plat _Site _Drainage Report _Other _Utility _Redline Utility _Landscape 6a City of Fort Collins FORT COLLINS-LOVELAND WATER DISTRICT \ SOUTH FORT COLLINS SANITATION DISTRICT V March 26, 2007 Mr. Steve Olt City of Fort Collins P.O. Box 580 Fort Collins, CO 80525 RE: Talon Estate PDP Dear Mr. Olt, RECEIVED fM2P CURRENT PLANNING The Fort Collins - Loveland Water District has reviewed the above mentioned project and submits the following comments. The existing District water services are to be connected to the new Fort Collins water line after the water line has been put into service. The District's existing water line must remain in service until all water services have been relocated. The District will require a signature block on the construction sheets that affect District facilities. All work on or around District facilities are to be coordinated with the District. The property needs to be excluded from the District boundaries. The Petition for Exclusion packet can be obtained at the District's office Please do not hesitate to contact me at 226-3104, ext. 104, if you have any questions or require additional information. Respectfully, �— Mr. Try W. Farrill, P.E. District Engineer xc: Mr. Michael D. DiTullio, District Manager Mr. Kevin Forbes, P.E., Stewart & Associates 5150 Snead Drive, Fort Collins, CO 80525 Phone (970) 226-3104 Fax (970) 226-0186 Yours Truly, mftobk� Steve Olt City Planner cc: Susan Joy George & Nadine Holter Current Planning file #42-05A Page 7 J Number: 128 Created: 3/ 29 / 2007 [3/29/071 Stormwater is ready for a hearing. Additional comments may follow at Final Compliance. Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington Topic: Water/Wastewater Number: 85 Created: 2/ 12/2007 [3/27/07] There are discrepancies on service line locations within the utility plans between the overall utility plan and the sanitary sewer plan and profile sheets. It still appears that some of the sewer services are shown on the high side of the lots which may eliminate basements [2/ 12/07] Coordinate locations of water/sewer services between utility plans and landscape plans. Some of the sewer services on the landscape plan are toward the high side of the lots. Number: 87 Created: 2/ 12/2007 [3/27/07] How much clear distance between water main and storm sewer at the point of crossing? 12" required. [2/ 12/07] Show 16" water main on storm sewer plan and profile sheet. Also include the FCLWD water main. (Has set of utility plans been provided to the district for review?) Number: 88 Created: 2/ 12/2007 [3/27/071 [2/ 12/07] Add FCLWD signature block. Number: 119 Created: 3 / 27 / 2007 [3/27/07] Revise grading to minimizes cuts on Falcon Drive over 16-inch water main and thereby, eliminate the need for insulation. Number: 129 Created: 3 / 29 / 2007 [3/ 29 / 07] See redlined plans for other comments. This development proposal may now be scheduled for an Administrative Public Hearing. Contact me to work with you in scheduling the date, time, and place for this hearing. Be sure and return all red -lined plans when you formally submit Final Compliance Plans. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at 221-6341. Page 6 .. Number: 112 Created: 3 / 23 / 2007 [3/23/071 Streetlights will be installed with this development. Department: PFA Issue Contact: Carte Dann Topic: Fire Number: 14 Created: 1 / 3 / 2007 [3/28/07] Both Longwing Drive and Broadwing Road are acceptable street names. [1/3/07] STREET NAME: Talon Drive cannot be used, because it is too similar to an existing street name. Also, because this street makes a 90- degree turn, it is required to become a second, new street with a separate name. Contact me with prospective street names and I can confirm whether they're acceptable. Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque Topic: Erosion/Sediment Control Number: 117 Created: 3/ 27/ 2007 [3/27/071 Please add the City's standard erosion control notes dated September 2003 to the plan set and delete any other notes related to erosion control. Topic: Stormwater Number: 18 Created: 1 / 4 / 2007 [3/27/07] The City requires a detailed grading plan for residential lots to include all the detailed information that is needed for the lot to be constructed per plan. This includes the building envelope, building FF elevations, lot corner spot elevations, high points or break point spot elevations within the lot that show a minimum of 2% grade to the lot corners, and actual final grading contours that show grading around the structures. A variance would be required to do anything less. The City recommends a meeting to discuss alternatives for a variance. This can be done now or after hearing. Also, why are the FF elevations so high above the sidewalk elevations? Is the plan to have garden level back yards, walkouts? Driveways may be extremely steep with these FF elevations. [2/ 15/07] [ 1 / 4 / 07] At final compliance, a detailed grading plan will be required showing final grades and building F.F. elevations. Number: 118 Created: 3 / 27 / 2007 [3/27/07] Since the FCLWD line is being abandoned, can the storm sewer be moved south to 10 feet north of the proposed sanitary sewer. Page 5 Number: 120 Created: 3 / 28 / 2007 [3/28/07] Hi Justin! Great submittal! I didn't have enough time this week to review the plans for Final Compliance items, sorry!! I will look at the plans in greater detail with your first round of Final Compliance review but everything looks good for hearing. Great job! : ) Topic: Utility Plans - Plan & Profiles Number: 40 Created: 1 / 6/ 2007 [3/23/07] [2/7/07] Repeat. Until this information is shown, the street grades may need to be adjusted to meet the minimum cover requirements. [1/6/07] Plan and Profile sheets - Please show the water line (keep in mind minimum cover requirements set forth in section 12.2.2. Show and station all proposed driveways, provide missing slope info & missing VC info, and for both street widenings - show, label and dimension in accordance with 7- 24. You can provide a detail off to the side if scannability becomes an issue. (Per Mike Herzig, R1 = 20'-36') Number: 72 Created: 2 / 8 / 2007 [3/23/07] (FC) You are doing this, just the notation is wrong on a couple of sheets. No biggie. See red -lines. [2 / 8/ 07] Final Compliance - mid -block cross -pans must be 12' minimum. Number: 130 Created: 3 / 30 / 2007 [3/30/07] If the District's water line is to be abandoned, it must be abandoned in accordance with LCUASS 22.1.2.A.2.c keeping in mind that you still have to meet minimum cover requirements required by 12.2.2. If you can't get the minimum cover over the abandoned pipe, then you'll need to remove the old pipe and backfill in accordance with 22.2.3. Department: Light & Power Issue Contact: Alan Rutz Topic: Light & Power Number: 109 Created: 3 / 23 / 2007 [3/23/07] The main electric system will be installed on the north side of Falcon Drive between the curb and sidewalk. A proposed storm drain shown in this area will need to be moved. Number: 110 Created: 3 / 23 / 2007 [3/23/07] The overhead electric line along Falcon Drive belongs to the City of Ft Collins. This line will be removed and undergrounded when this project is developed. Number: 111 Created: 3 / 23 / 2007 [3/23/07] Show location of the existing gas line and the proposed extension of the gas line along Falcon Drive. Page 4 Number: 116 Created: 3 / 23 / 2007 [3/23/071 (FC) New plantings are shown on the south side of Falcon Drive at the Broadwing Road intersection. This development is not required to plant or maintain them in any way. Just wanted to make sure that you knew that. Topic: Plat Number: 101 [3/23/071 Created: 2/ 14/2007 [2/ 14/07] From Technical Services - Add note about wildlife buffer, see redlines. Topic: Site Number: 64 Created: 2 / 8 / 2007 [3/23/07] [2/8/07] Dimension all sidewalks and parkways. Number: 71 Created: 2 / 8 / 2007 [3/23/071 (FC) [2/8/07] Tract A easements do not match the plat. Number: 113 Created: 3 / 23 / 2007 [3/23/07] (FC) Use a radius instead of angle points where the sidewalk meanders around. Also, suggest increasing the width of the sidewalk by 2' and just doing concrete to the existing fence because you can't use gravel or mulch in that area (see 16-1 in Chapter 16 of LCUASS). Landscaping this area is tough ... very hard to maintain BUT whatever you come up with that doesn't contradict 16-1 is ok by me : ) Number: 114 Created: 3 / 23 / 2007 [3/23/07] (FC) Missing a driveway at Falcon Drive bend. Topic: Utility Plans - General Number: 34 Created: 1 / 5/ 2007 [3/23/071 (FC) Just carrying the comment forward to final compliance. [2/7/07] Repeat. Driveways need to be shown on the plans designed in accordance with 706. Per LCUASS 9.4.2, driveways must be perpendicular to the CL of the road, plus or minus 10 degrees, for a minimum of 25' from the curb. [ 1 / 5/ 07] All existing driveways along Falcon Drive must be built in accordance with detail 706. Page 3 ti • Number: 126 Created: 3 / 29 / 2007 [3/29/071 The Property Boundary lines along the north and east sides of the property, although labeled as asked for, seems inconsistent (line weight) from the Property Boundary lines along the west and south sides of the property. Number: 127 Created: 3 / 29 / 2007 [3/29/07] Under PROPERTY DESCRIPTION on the Site Plan, the reference to Replat of Tract 'A' is incorrect. This property has not been platted and there is no Tract 'A' to replat; therefore, this should be changed to Talon Estates, situated in ... Topic: Stormwater Number: 122 Created: 3 / 29 / 2007 [3/29/07] Ed Wendel of the Pleasant Valley & Lake Canal Company has indicated that it appears that his concerns with storm drainage have been met with the storm drain connection to Taft Hill Road. Topic: Utility Plans Number: 95 Created: 2/ 13/2007 [3/29/07] Carried over only as a reminder. [2/ 13/07] Len Hilderbrand of Xcel Energy offers the following comments: a. An existing gas main ends at 448' west of the west right-of-way line of South Taft Hill Road. The main is a 3/4" MW steel pipe. b. To serve the proposed new lots in this development, the existing 3/4" main will need to be re -enforced to a new 1-1/4" main. Please contact Len directly if you need additional information regarding his comments. Topic: Utility Plans -General Number: 121 Created: 3 / 29 / 2007 [3/29/071 A copy of the comment letter (dated 3/26/07) received from Terry Farrill, Fort Collins -Loveland Water District, is attached to this City Staff comment letter. Department: Engineering Issue Contact: Susan Joy Topic: Landscape Plans Number: 115 Created: 3/ 23/ 2007 [3/23/071 (FC) Driveways need to match the utility plans. Page 2 r STAFF PROJECT REVIEW City of Fort Collins Stewart & Associates, Inc. Date: 04/02/2007 c/o Kevin Forbes, P.E. 103 South Meldrum Street Fort Collins, CO 80521 Staff has reviewed your submittal for TALON ESTATES, PDP - TYPE 1, and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Steve Olt Topic: General Number: 125 Created: 3 / 29 / 2007 [3/29/07] City staff has determined that the latest set of revised plans as submitted are in a condition to enable staff to schedule an Administrative Public Hearing. Comments expressed in this letter may be addressed with the Applicant's formal Final Compliance Plan submittal for review, after the public hearing. Topic: Landscape Plans Number: 123 Created: 3 / 29 / 2007 [3/29/07] The Landscape Plan specifies 1.25" caliper street trees, which are permitted by the table in Section 3.2.1(D)(4) Tree Species and Minimum Sizes of the Land Use Code, for street trees on a Residential Local Street. However, a neighbor has expressed a request for this development to provide as much landscaping as possible to help mitigate the visual impact of a number of new homes across Falcon Drive from the existing homes. The standard minimum street tree size is 2.0" caliper. Although not required by the City, it would be a significant and more considerate gesture if this developer would initially plant at least 2.0" caliper street trees along the Falcon Drive frontages. If the developer is willing, please make this change in the Plant List on the Landscape Plan. Number: 124 Created: 3 / 29 / 2007 [3/29/071 On the Landscape Plan, please label, or indicate "Typical" somewhere, the Property Boundary. Topic: Site Number: 49 Created: 2 / 2 / 2007 [3/29/071 However, the Property Boundary must be labeled on the Site & Landscape Plans so that it can be distinguished from the lot lines. [2/2/07] Please label the Property Boundary on the Site Plan. Falcon Drive should not be shown to be included in the Property Boundary as it appears to be on the Site Plan. The Landscape Plan and Subdivision Plat are correct. Page I