HomeMy WebLinkAboutTALON ESTATES - FDP - 42-05A/B - CORRESPONDENCE - (13)Number: 264 Created: 10/19/2010
[10/19/10] Please correct the Basis Of Bearings statement on sheets C5.1, C5.2 & C5.3.
Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington
Topic: WaterMastewater
Number: 265 Created: 10/19/2010
[10/19/10] Move the proposed water main in the N/S portion of Falcon Drive out into the
street to provide separation from the UG electric and gas that are now shown on the plans.
Provide 10 feet of separation from the dry utilities and minimum of 5 feet from the curb and
gutter.
Number: 266 Created: 10/19/2010
[10/19/10] Label the lengths of water main between values, fittings, etc., etc.
Be sure and return all of your redlined plans when you re -submit.
If you have any questions regarding these issues or any other issues related to this project,
please feel free to call me at (970) 221-6750.
Yours Truly,
Steve Olt
City Planner
Page 2
6
aSTAFF PROJECT REVIEW
City of Fort Collins
KEVIN FORBES, P.E. Date: 10/20/2010
STEWART & ASSOCIATES, INC.
103 S. MELDRUM ST.
FORT COLLINS, CO 80521
Staff has reviewed your submittal for TALON ESTATES PDP - TYPE I AND FINAL PLANS,
and we offer the following comments:
ISSUES:
Department: Engineering Issue Contact: Susan Joy
Topic: General
Number: 260 Created: 8/13/2010
r [10/19/10]
[8/13/10] The parkway width on the Site Plan does not match the parkway width shown on
the Utility Plans.
Topic: Soils Report
reumber: 170 Created: 10/5/2007
iport.
0/19110][8/5/10] [1/24/08] Thank you for submitting the additional soils investigation Based on the recommendations of the report, please provide evidence from the
Colorado Department of Public Health and Environment that the levels found within the site
are acceptable for the proposed development.
[10/5/07] As a condition of approval, this development was to provide evidence of a soils
report evaluating the presence of soil contaminants on the subject property. This
information was not received within the submitted soils report or by separate document.
Topic: Utility Plans
Number: 259 Created: 8/13/2010
/ [10/19/10]
[8/13/10] Please show where the existing gas line is along the east west portion of Falcon
Drive or how it ties into the north south gas line along Falcon.
Topic: Utility Plans -Cover
Number: 246 Created: 8/10/2010
(10/19/10] Please change the month to October or the month you print the mylars for
signature. Thanks!!
[8/10/10] Change the date under the legal description to the month in which you submit
mylars and the year. No date of the month is required.
Department: Technical Services Issue Contact: Jeff County
Topic: Plat
Number: 262 Created: 10/19/2010
[10/19/10] The Subdivision Plat boundary & legal close.
Topic: Utility Plans
Number: 263 Created: 10/19/2010
[10/19/10] Please correct the benchmark descriptions on sheets C2.1 & C4.0.