Loading...
HomeMy WebLinkAboutKING SOOPERS FUELING STATION (CEDARWOOD PLAZA) - FDP - 40-07/A - CORRESPONDENCE - (5)City of Fort Collins Planning and Zoning PO Box 580 Fort Collins, CO 80522-0580 Fay: 970-416-2020 FINAL PLAN COMMENT SHEET DATE: October 27, 2008 TO: Technical Services PROJECT PLANNER: Steve Olt IZ M # 40-07/A KING SOOPERS FUELING CENTER / CEDARWOOD PLAZA — TYPE I Please return all comments to the project planner no later than the staff review meeting: NOVEMBER 26, 2008 Note - Please identify Your redlines for future reference 1, MIMOR LIAM 04652 ?iXT 15506S, 5NCer5 04 3 Wr-Z£ THE om-Y 5K68T5$ +245cE'1vE7> P-4e ❑ No Problems 0 Problems or concerns (see below, attached, or DMS) lal GM -Zrq-G 111 z to l o g Name (please print) CHECK HERE IF YOU WISH TO RECEIVE COPIES OF REVISIONS X Plat XSite _Drainage Report _Other XUtility _Redline Utility LLandscape Department: PFA Issue Contact: Carie Dann Topic: Fire Number: 123 Created: 12/3/2008 [ 12/3/08] PFA has no additional comments at this time. Department: Stormwater-Water-Wastewater Issue Contact: Wes Lamarque Topic: Stormwater Number: 107 Created: 11 /21 /2008 [11/21/08] The City would like a more manicured grass in the parkway where the water quality treatment is being proposed. Irrigation would be allowed even though this is a water quality treatment area. Sod can not be used due to the clay soils that sod is farmed in, however a blue grass, fescue, or similar type grass seed mix can be used. Number: 108 Created: 11/21/2008 [ 11/21/08] Please see other minor comments on the red -lined plans. Department: Stormwater-Water-Wastewater Issue Contact: Roger Buffington Topic: Water/Wastewater Number: 71 Created: 4/l/2008 [ 12/2/08] Contact John Nelson (970-221-6677) regarding backflow requirements. If it is a reduced pressure principle device, it must be installed above ground rather than in a pit. [5/19/08] Back flow preventer must be upstream of frost -proof yard hydrant. Will the backflow preventer be in a pit (separate from water meter pit)? If yes, show pit on the utility plan? If no, how will the water service and backflow preventer be winterized? [4/1/08] .Frost free yard hydrants not allowed unless proper backflow prevention is provided. Contact John Nelson (221-6677) for information regarding notes and details to be included on utility plans. Randy Maizland should be contacted (970-221-6605) to determine if another formal round of review and staff review is needed. Be sure and return all red -lined plans if / when you re- submit. If you have any questions regarding these issues or any other issues related to this project, please feel free to call me at 970-221-6341. Yours 46 lyav " Steve Olt City Planner cc: Randy Maizland, Engineering Wes Lamarque, Stormwater King Soopers Current Planning File #40-07A Page 3 Number: 114 Created: 11 /26/2008 [11/26/08] Please show all proposed asphalt cuts as perpendicular intersecting lines. Radius cuts are not likely to happen. Number: 115 Created: l l /26/2008 [11/26/08] Please remove note 28 from the access ramps shown on the driveways. The ramps will be constructed per the driveway detail 707 and not 1606 or 1607 which are to be used at the street corner only. The driveway ramps should utilize the curb option rather than a flare option on the back side. See red -lines for clarification. Show curb rather than flare on the plans. Number: 116 Created: 11 /26/2008 [11/26/08] The driveways are called out with 20 foot radius but it is not drawn correctly on the plans. Please show the driveway radius correctly at 20 feet continuous from back of sidewalk to flow line. See Detail 707 and red -lines for clarification. Number: 117 Created: 11 /26/2008 [11/26/08] Please remove the horizontal groove lines from the H.C. ramps at the intersection corner. Groove lines should not be tooled into the ramp as this is no longer the standard. Only truncated domes are necessary per the LCUASS detail. Number: 118 Created: 11 /26/2008 [11/26/08] Please correct all line over text conflicts on the Grading Plan sheet. See red- lines. These conflicts do not meet scannability requirements of LCUASS Appendix E. Number: 119 Created: 11 /26/2008 [11/26/08] The Cut-off Wall being used to keep water from draining / seeping under the street section on Taft Hill should be extended in at right angles on both ends for at least 3 feet. See red -lines for clarification. Number: 120 Created: l 1/26/2008 [11/26/08] Please specify some method of sealing the joint between the top of the cut-off wall and the curb & gutter section so that water cannot infiltrate through the joint. See the detail on the bottom of sheet 5 for clarification. Number: 121 Created: 11 /26/2008 [11/26/08] See scannability comments on Detail Sheet 6. Additionally, the sidewalk chase drain detail 709 was revised and updated 2007. Please use the updated detail and also insert City of Fort Collins Stormwater Detail D-10 on the detail sheet. I can provide you with this detail if you do not have access to it. Topic: Technical Services Number: 122 Created: 11 /26/2008 [11/26/08] Minor line over text conflicts should be corrected. See red -lines provided. Page 2 STAFF PROJECT REVIEW City of Fort Collins Galloway & Company Date: 12/8/2008 c/o Matthew Duhaime 5350 DTC Parkway Greenwood Village CO 80111 Staff has reviewed your submittal for KING SOOPERS FUELING CENTER, FINAL PLANS - #40-07A, and we offer the following comments: ISSUES: Department: Current Planning Issue Contact: Steve Olt Topic: Planning Number: 125 Created: 12/8/2008 [ 12/8/08] Steve Olt of the Current Planning Department has no concerns with the Final Plan submittal documentation and, therefore, has no further comments to offer. Topic: Zoning Number: 124 Created: 12/8/2008 [12/8/08] Peter Barnes of the Zoning Department has no concerns and has no additional comments to offer. Department: Engineering Issue Contact: Randy Maizland Topic: Engineering Number: 109 Created: 11 /26/2008 [11/26/08] Please submit a signed deed of dedication and legal exhibits for right-of-way (ROW) on Taft Hill and Elizabeth as reviewed and approved by the City Attorney regarding deed language. Number: 110 Created: 11 /26/2008 11/26/08]- Please submit an off -site temporary construction and public access easement signed deed of dedication and legal exhibits for the cross lot access being constructed into the King Soopers parking lot area. Number: 111 Created: 11 /26/2008 [ 11/26/08] Please revise the title block on the Utility Plan set to match the title at the top of the cover sheet (Typ.). See redlines for clarification. Number: 112 Created: 11 /26/2008 [11/26/08] The project title does not need to be provided at the top of every sheet in the Utility Plan set. You may leave it if desired but it is not preferred. Number: 113 Created: 11 /26/2008 [ 11/26/08] Please enlarge and use bolder text for the Alta Survey FOR REFERENCE ONLY designation in the bottom right corner of the sheet. Page 1