Loading...
HomeMy WebLinkAboutRIDGEWOOD HILLS RESIDENCES - N.A. (33-10) - SUBMITTAL DOCUMENTS - ROUND 1 - CORRESPONDENCECAy of ort Co ins 5. Section 3.5.2(C)(1) of the Land Use Code sets forth requirements for buildings Orientation to a Connecting Walkway. Building Types "B" and "C" on the development plan may not satisfy the requirements and may prompt the need for a Modification of Standard. 6. The proposed development project is subject to a Type 1 review and public hearing, the decision maker for Type 1 hearings is an Administrative Hearing Officer. The applicant for this development request is not required to hold a neighborhood meeting for a Type 1 hearing, but if you would like to have one to notify your neighbors of the proposal, please let me know and I will can help you in setting a date, time and location for a meeting. Neighborhood Meetings are a great way to get public feedback and avoid potential hick -up that may occur later in the review process. 7. Please see the Development Review Guide at www.fcgov.com/drg. This online guide features a color coded flowchart with comprehensive, easy to read information on each step in the process. This guide includes links to just about every resource you need during development review. 8. This development proposal will be subject to all applicable standards of the Fort Collins Land Use Code (LUC), including Article 3 General Development Standards. The entire LUC is available for your review on the web at hftp://www.colocode.com/ftcollins/landuse/begin.htm. 9. If this proposal is unable to satisfy any of the requirements set forth in the LUC, a Modification of Standard Request will need to be submitted with your formal development proposal. Please see Section 2.8.2 of the LUC for more information on criteria to apply for a Modification of Standard. 10. Please see the Submittal Requirements and Checklist at: hftp://www.fcgov.com/currentplanning/submiftals.php. 11. The request will be subject to the Development Review Fee Schedule that is available in the Community Development and Neighborhood Services office. The fees are due at the time of submittal of the required documents for the appropriate development review process by City staff and affected outside reviewing agencies. Also, the required Transportation Development Review Fee must be paid at time of submittal. 12. When you are ready to submit your formal plans, please make an appointment with Community Development and Neighborhood Services at (970)221-6750. Page 8 of 8 / .Collins 12. A 100' temporary turnaround is required at the end of Avondale. You may construct one either onsite or offsite. If offsite, an access easement and temporary construction easement is required from the neighboring property owner. A letter of intent from that owner is required prior to scheduling a public hearing with the acutual easements dedicated prior to final plan approval. A cash escrow to remove the turnaround in the future plus a 25% contingency is required prior to the issuance of the first building permit. If constructing the turnaround onsite, then a cash escrow for the removal of the turnaround plus constructing the remaining street frontage is due as above. 13. No structures of any kind (including overhangs, footers, foundations, etc.) are allowed withing an easement. ELECTRIC ENGINEERING Contact: Justin Fields, 970-224-6150, ifields(g-fcgov.com 1. Meter, streetlight, and transformer locations need to be coordinated with Light and Power Engineering (970-221-6700). A cost estimator for Light and Power charges is available at the website: http://www.fcgov.com/electric/fee-estimate.php BUILDING INSPECTION Contact: Russell Hovland, 970-416-2341, rhovland(a)fcgov.com 1. Commercial and multi -family development proposals are required to have a pre -submittal meeting with the Building Department prior to formal submittal. See attached letter with more detailed information. CURRENT PLANNING Contact: Steve Olt, 970-221-6341, solt(&fcgov.com 1. Minimum parking requirements for residential development are set forth in Section 3.2.2(K) (1) of the City's Land Use Code. They are based on the number of bedrooms per each dwelling unit. 2. The LMN, Low Density Mixed -Use Neighborhood District, which Tract'N' is in, has a minimum residential density requirement of 5 dwellings per net acre and a mxximum residential requirement of 8 dwelling units per gross acre. However, if the project is proposed to be qualified affordable housing on 10 acres or less then the density can be up to 12 dwelling units per gross acre. 3. The MMN, Medium Density Mixed -Use Neighborhood District, which Tract'T' is in, has a overall minimum average density requirement of 12 dwelling units per net acre. 4. City staff is strongly recommending that the applicant/developer conduct a neighborhood meeting prior to formal submittal of a Project Development Plan. Even though the proposed development will be subject to an Administrative (Type 1) review and public hearing in front of a Hearing Officer, which does not require a neighborhood meeting, there could be concerns about or opposition to the development proposal. Because of that possibility it is far better to introduce yourself and the plan to neighbors at an informal meeting than at the public hearing near the end of the development review process. Page 7 of 8 Cfty of Fort Collins to be placed on both the front and rear of every unit. 2006 International Fire Code 505.1 11. CUL-DE-SAC Any fire apparatus access road that exceeds 150 feet in length is required to have a a turnaround with a diameter of at least 100 feet. 12. CLUBHOUSE If the clubhouse has an occupant load of 50 or more, it will become an Assembly occupancy and must meet applicable requirements for means of egress, fire sprinklers and occupant load signs. ENGINEERING DEVELOPMENT REVIEW Contact: Susan Joy, 970-221-6581, sioy(cDfcgov.com 1. Larimer County Road Impact Fees and Street Oversizing Fees are due at the time of building permit. Please contact Matt Baker at 224-6108 if you have any questions. 2. Transportation Development Review Fee (TDRF) is due at the time of submittal. For additional information on these fees, please see hftp://www.fcgov.com/engineering/dev-review.php 3. Any damaged curb, gutter and sidewalk existing prior to construction, as well as streets, sidewalks, curbs and gutters, destroyed, damaged or removed due to construction of this project, shall be replaced or restored to City of Fort Collins standards at the Developer's expense prior to the acceptance of completed improvements and/or prior to the issuance of the first Certificate of Occupancy. 4. Please contact Joe Olson and Transportation Planning to schedule a scoping meeting and determine if a traffic study is needed for this project. 5. Any public improvements must be designed and built in accordance with the Larimer County Urban Area Street Standards (LCUASS). 6. This project is responsible for dedicating any right-of-way and easements that are necessary for this project. 7. Utility plans and a development agreement will be required for this project. 8. A Development Construction Permit (DCP) will need to be obtained prior to starting any work on the site. 9. Avondale Rd was designed with the Ridgewood Hills 3rd Filing and you may use and construct the road along your frontage using that design. Your design must tie into it. However, if you wish to change Avondale's street elevation for instance, then a new design will be required plus the 1000' of preliminary offsite design. 10. Parking setbacks apply, please see chapter 19 of the Larimer County Urban Area Standards. 11. Please see the Ridgewood Hills PUD 3rd Filing plat for existing easements on the property. If replatting, then the existing access easement can be vacated by plat. If not replatting, then additional TDR Fees apply per dedication or vacation. Page 6 of 8 Cfty of rt Collins ��— fire -alarm system. 2006 International Fire Code 506.1; PFA BUREAU POLICY 88-20 5. FIRE DEPARTMENT CONNECTION Fire department connections shall be installed remote from the buildings, and located on the street or fire lane side of buildings, fully visible and recognizable from the street or nearest point of fire department vehicle access or as otherwise approved by the fire code official. 2006 International Fire Code 912.2 and PFA Fire Prevention Bureau Policy 6. REQUIRED ACCESS Fire access roads (fire lanes) shall be provided for every facility, building or portion of a building hereafter constructed or moved into or within the PFA's jurisdiction when any portion of the facility or any portion of an exterior wall of the first story of the building is located more than 150 feet from fire apparatus access as measured by an approved route around the exterior of the building or facility. This fire lane shall be visible by painting and signage, and maintained unobstructed at all times. A fire lane plan shall be submitted for approval prior to installation. In addition to the design criteria already contained in relevant standards and policies, any new fire lane must meet the following general requirements: - Be designed as a flat, hard, all-weather driving surface (asphalt or concrete) capable of supporting fire apparatus weights. Compacted road base shall be used only for temporary fire lanes or at construction sites. - Have appropriate maintenance agreements that are legally binding and enforceable. - Be designated on the plat as an Emergency Access Easement. - Maintain the required minimum width of 20 feet throughout the length of the fire lane (30 feet on at least one long side of the building when the structure is three or more stories in height). If the building is equipped throughout with an approved automatic fire -sprinkler system, the fire code official is authorized to increase the dimension of 150 feet. 2006 International Fire Code 503.1.1, 503.2.3, 503.3, 503.4 and Appendix D 7. TURNING RADII The required turning radii of a fire apparatus access road shall be a minimum of 25 feet inside and 50 feet outside 2006 International Fire Code 503.2.4 and Appendix D103.3 8. HAZARDOUS MATERIALS Toxic, corrosive, or reactive materials, or flammable/combustible liquids (as defined in the Uniform Fire Code) if used, stored, or handled on site, must have a Hazardous Materials Impact Analysis (HMIA) completed and supplied to the Planning Department and the Fire Department. (What do you have? How much? How do you prevent it from being a public threat?) PLEASE NOTE: This comment pertains to a swimming pool. FCLUC3.4.5 9. CABANA? What exactly is the cabana and what are its features? 10. ADDRESS NUMERALS Address numerals shall be visible from the street fronting the property, and posted with a minimum six-inch high numerals on a contrasting background. (Bronze numerals on brown brick are not acceptable). Due to building configuration, address numerals will be required Page 5 of 8 City of Fort Collins the original system did not include water quality treatment. 3. The design of this site must conform to the drainage basin design of the Fossil Creek Drainage Master Drainage Plan as well the City's Design Criteria and Construction standards. 4. Stormwater development fees are $6,313/acre ($0.1449/sq.ft.) for new impervious area over 350 sq. ft. In addition, there is a $1,045/acre ($0.024/sq.ft.) review fee. No fee is charged for existing impervious area. These fees are to be paid at the time each building permit is issued. Information on fees can be found on the City�,s web site at hftp://www.fcgov.com/utilities/builders-fees.php or by contacting Jean Pakech at 221- 6375. PARK PLANNING Contact: Craig Foreman, 970-221-6618, cforeman(&fcgov.com 1. No comments FIRE AUTHORITY Contact: Carie Dann, 970-219-5337, CDANN(&poudre-fire.org WATER SUPPLY Fire hydrants, where required, must be the type approved by the water district having jurisdiction and the Fire Department. Hydrant spacing and water flow must meet minimum requirements based on type of occupancy. Minimum flow and spacing requirements include: - Commercial and multi -family dwellings 1,500 gpm at 20 psi residual pressure, spaced not further than 300 feet to the building, on 600-foot centers thereafter - Residential within Urban Growth Area, 1,000 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter - Residential outside Urban Growth Area, 500 gpm at 20 psi residual pressure, spaced not further than 400 feet to the building, on 800-foot centers thereafter. These requirements may be modified if buildings are equipped with automatic fire sprinkler systems. 2006 International Fire Code 508.1 and Appendix B 2. RESIDENTIAL AUTOMATIC FIRE SPRINKLERS An automatic sprinkler system installed in occupancies in accordance with Section 903.3 shall be provided throughout all buildings with a Group R (Residential) fire area. Residential or quick -response standard sprinkler heads shall be used in dwelling units and guest -room portions of the building. 2006 International Fire Code 903.2.7 3. FIRE LINE REQUIREMENT Buildings that are required to be fire sprinklered shall have a minimum 6-inch fire line unless hydraulic calculations can support a smaller fire line. NFPA 13 (2007) 23.1.3 4. KEY BOXES REQUIRED Poudre Fire Authority requires a key box ("Knox Box") to be mounted in approved location(s) on every new building equipped with a required fire -sprinkler system or Page 4 of 8 CRY of Fort Collins WATER -WASTEWATER ENGINEERING Contact: Roger Buffington, 970-221-6854, rbuffington(cDfcgov.com 1. Water and wastewater service in this area are provided by the Fort Collins -Loveland Water District and the South Fort Collins Sanitation District. TRANSPORTATION PLANNING Contact: Matt Wempe, 970-416-2040, mwempe 1. Avondale Road is designated as a collector street in the Master Street Plan. The plans need to show striping for on -street parking and bicycle lanes consistent wtih Avondale west of Triangle. 2. The eastern pedestrian crosswalk of the Avondale and Triangle roundabout must have the same enhanced crosswalk treatment as the other three roundabout crossings. 3. Where will bicycle parking be located? The ideal location is a hard surface, secure, well -lit, and protected from the elements. In -building bicycle parking is encouraged. 4. Directional ADA ramps are required for all pedestrian crossings. S. Pedestrian crossings and ramps will be required at Woodrow and Triangle and Avondale and the private driveway. 6. How will the sidewalk between the tennis courts and the clubhouse connect across the parking lot? STORMWATER ENGINEERING Contact: Glen Schlueter, 970-224-6065, gschlueter(cDfcgov.com 1. The design engineer needs to review the drainage study for Ridgewood Hills Third Filing dated June 2000. In that report, Tract N was left to drain as it did historically, but in the future, the plan was to drain it through either Pond 1 to the north or a pond to the south. Tract T does drain to the south pond through a 36 inch pipe, but it appears the percent impervious used was for the existing undeveloped land. Therefore, the SWMM will need to be updated with the proposed percent imperviousness. It appears both ponds may be oversized so there may be volume available for additional detention. The as -built volumes need to used in the model as well. The latest rainfall intensity curves need to be applied since the modeling used was the old rainfall. In addition there is a 'Preliminary Drainage and Erosion Control Study for Ridgewood Hills Fourth Filing" prepared by Loonan and Associates, Inc. that designed a drainage system for both of these parcels. It was never approved but it may aid the design engineer in designing the system for this proposal. 2. Water quality treatment is also required as described in the Urban Storm Drainage Criteria Manual, Volume 3 - Best Management Practices (BMPs). Extended detention in the existing ponds is probably the easiest way to treat the runoff. However, if the existing ponds are used, the water quality capture volume will need to be calculated for the entire area draining to them. An option would be to provide onsite water quality treatment since Page 3 of 8 CONCEPTUAL REVIEW STAFF COMMENTS Meeting Date: June 28, 2010 Item: Ridgewood Hills Residential Applicant: Marc Hendricks 7350 East Progress Place, # 208 Greenwood Village, CO 80111 marc@hendrickscommunities.com Land Use Data: "ICof .- ColElns The Conceptual Development Plan for Ridgewood Hills Multi -family project consists of a plan for development of two parcels, each approximately 5 acres in size. Tract N is zoned as LMN, with a very small corner of the tract zoned MMN. Development of this site will include 40 residences contained in 5 separate, two story buildings. Each building is proposed to contain 8 apartment residences, in order to comply with the permitted uses for the LMN district. Two bedroom units are proposed. Tract T is zoned MMN in its entirety. The development proposal includes 136 residences, in 4 separate buildings on this parcel. The buildings will include a mix of one and two bedroom units. The buildings will be three -level structures with two -level ends. The buildings will vary in size, with 44 residences in the largest building and 16 residences in the smallest building. There is a clubhouse of approximately 3,500 square feet proposed on this site. Comments: ZONING Contact: Jenny Nuckols, 970-416-2313, jnuckols(a�fcgov.com 1. The properties are located in the LMN and MMN zoning districts (Low -density mixed -use and Medium -density Mixed -use) Both districts require a Type 1 review process. 2. Parking for residential is based on the number of bedrooms per unit. See Section 3.2.2(K) for minimum standards as well as 3.2.2(K)(5)for handicap parking space requirements. 3.2.2(C)(4) for bicycle parking. 3. Provde trash/recyclabe enclosures to meet needs of the development. Enclosures should be built to match the buildings. 4. Provide a landscape plan showing all site landscaping, street trees, perimeter landscaping around buildings. Note plant counts and types. See 3.2.1 for landscape standards and requirements. 5. Provide buidling elevations showing building heights, colors, materials etc. Page 2 of 8 City of Fort Collins June 28, 2010 Marc Hendricks 7350 East Progress Place, # 208 Greenwood Village, CO 80111 RE: Ridgewood Hills Residential Dear Marc, Community Development and Neighborhood services 281 North College Avenue PO Box 580 Fort Collins. CO 80522 970.221.6750 970,224.6134 - fax fcgov. com/currentplanning Attached, please see a copy of Staffs comments concerning the request referred to as the Ridgewood Hills Residential, which was presented before the Conceptual Review Team on June 28, 2010. The comments offered informally by staff during the Conceptual Review will assist you in preparing the detailed components of the project application. Modifications and additions to these comments may be made at the time of formal review of this project. If you should have any questions regarding these comments or the next steps in the review process, please feel free to contact me at 970-221-6341. Sincerely, / &%, U Steve Olt City Planner 281 North College Avenue - P.O. Box 580 - Fort Collins, CO 80522 - 0580 — (970) 221-6750 - FAX (970) 224-6134