Loading...
HomeMy WebLinkAboutKAUFMAN & ROBINSON OFFICE DEVELOPMENT - PDP - 40-08 - REPORTS - RECOMMENDATION/REPORTKaufman & Robinson Office Development, Project Development Plan, #40-08 December 2, 2009 Administrative Hearing Page 11 C. The Kaufman & Robinson Office Development, PDP complies with applicable Land Use and Development Standards contained in ARTICLE 4 - DISTRICTS, Division 4.28 - Industrial of the LUC, with the following exceptions: • The standard located in Subsection 4.28(E)(2)(b) — Orientation, which requires that a building face abut the required minimum landscaped yard for at least 30% of the building frontage. • The standard located in Subsection 4.28(E)(3)(a)2, which requires a minimum 30' deep landscaped yard be provided on the subject property along the street right-of-way for Blue Spruce Drive. • The standard located in Subsection 4.28(E)(3)(a)3, which requires a minimum 80' deep landscaped yard be provided along any boundary line that adjoins a zone district that is predominantly characterized by permitted residential uses. The undeveloped property directly east is in the LMN, Low Density Mixed -Use Residential District. Staff has determined that the development plan as submitted is not detrimental to the public good and that the plan as submitted will promote the general purpose of the standards for which the modifications are requested equally well than would a plan which complies with the standards for which the modifications are requested, as set forth in Section 2.8.2(H)(1) of the LUC. RECOMMENDATION: Staff recommends approval of the request for a modification of the standard in Subsection 4.28(E)(2)(B) of the Land Use Code. Staff recommends approval of the request for a modification of the standard in Subsection 4.28(E)(3)(a)2 of the Land Use Code. Staff recommends approval of the request for a modification of the standard in Subsection 4.28(E)(3)(a)3 of the Land Use Code. Staff recommends approval of the Kaufman & Robinson Office Development, Project Development Plan - #40-08. Kaufman & Robinson Office Development, Project Development Plan, #40-08 December 2, 2009 Administrative Hearing Page 10 • Regarding the standard located in Subsection 4.28(E)(2)(b) — Orientation, which requires that a building face abut the required minimum landscaped yard for at least 30% of the building frontage. The applicant is proposing to provide a parking lot containing 9 spaces between the front of the building and Blue Spruce Drive. The distance between the front of the building and the property line would be 80' and the 30' deep landscaped yard would not be included. The plan would be consistent with the majority of the block faces in this developed area along Blue Spruce Drive, with parking between the buildings and the property lines and street, on both the east and west sides. • Regarding the standard located in Subsection 4.28(E)(3)(a)2, which requires a minimum 30' deep landscaped yard be provided on the subject property along the street right-of-way (ROW) for Blue Spruce Drive. The plan as submitted contains a parking lot with 9 spaces between the building and the ROW. The plan would be consistent with the majority of the block faces in this developed area along Blue Spruce Drive, with parking between the buildings and the property lines and street, on both the east and west sides. • Regarding the standard located in Subsection 4.28(E)(3)(a)3, which requires a minimum 80' deep landscaped yard be provided along any boundary line that adjoins a zone district that is predominantly characterized by permitted residential uses. The undeveloped property directly east is in the LMN, Low Density Mixed -Use Residential District. The building will be set back from the east property line a distance of 80' with a detention pond located in this setback area. No landscaping is being proposed in the detention pond; therefore, the plan as submitted does not fully satisfy this section of the LUC. However, there is an existing pond with significant vegetation (trees and shrubs) on the property to the east that will provide an additional landscaped separation of about 300' between this building and future residential. S. Findings of Fact/Conclusion: A. The Kaufman & Robinson Office Development, PDP proposal contains uses permitted in the Industrial District, subject to an administrative review and public hearing. B. The Kaufman & Robinson Office Development, PDP meets applicable standards as put forth in ARTICLE 3 - GENERAL DEVELOPMENT STANDARDS of the LUC, including Division 3.2 - Site Planning and Design Standards; Division 3.3 - Engineering Standards; Division 3.5 - Building Standards; and, Division 3.6 - Transportation and Circulation. Kaufman & Robinson Office Development, Project Development Plan, #40-08 December 2, 2009 Administrative Hearing Page 9 amount of fenestration facing the proposed project. The majority of the openings that do face the proposed project site are overhead doors with an industrial look. The parking for the commercially zoned lot extends to the street with no landscaping of any kind. The proposed project is on an infill lot, developing one of the few remaining vacant properties in this subdivision. The planned orientation of street/parking/building is consistent with all of the properties in this subdivision to the south, and the building location proposed creates a uniform setback with these properties. There is no requirement for a district buffer south of Red Cedar Circle as there exists industrial zoning on both sides of Blue Spruce Drive. The combined requirement of the district buffer and building frontage on the buffer, eliminates the possibility of placing parking to the west of the building, resulting in a building side or'end condition' facing the street, with the building entry located on an 'off-street' side. Allowing parking between the street and the building provides for the primary building entrance located facing the street. This orientation provides a more architecturally detailed and visually attractive fagade to face the district boundary. The subdivision creating these lots was filed in 1974, and the current owners purchased the property in 1996; both occurred prior to adoption of the current district buffer standard in 1997. To mitigate the request to waive the district buffer requirements and ensure that the intent of the Land Use Code is met, we have proposed increasing the landscaping along Blue Spruce Drive to include one additional tree and six additional shrubs as screening to the parking. Additionally, a pedestrian link has been provided from the new sidewalk along Blue Spruce Drive, across the parking to the main entry. Given the age of this development, the nature of this infill development and the character of the neighboring properties, we feel that this modification is not unreasonable or a substantial departure from the intent of the requirements in the Land Use Code. Staffs Evaluation: In evaluating the proposed modifications of standards set forth in Subsections 4.28(E)(2)(b), 4.28(E)(3)(a)2, and 4.28(E)(3)(a)3, staff has determined that the development plan as submitted is not detrimental to the public good and that the plan as submitted will promote the general purpose of the standards for which the modifications are requested equally well than would a plan which complies with the standards for which the modifications are requested. Kaufman & Robinson Office Development, Project Development Plan, #40-08 December 2, 2009 Administrative Hearing Page 8 system, the strict application of the standard sought to be modified would result in unusual and exceptional practical difficulties, or exceptional or undue hardship upon the owner of such property, provided that such difficulties or hardship are not caused by the act or omission of the applicant; or (4) the plan as submitted will not diverge from the standards of the Land Use Code that are authorized by this Division to be modified except in a nominal, inconsequential way when considered from the perspective of the entire development plan, and will continue to advance the purposes of the Land Use Code as contained in Section 1.2.2. " The applicant has proposed that the modifications of the standards would not be detrimental to the public good and that they meet the requirements of Section 2.8.2(H)(1) of the LUC. Applicant's Request: 1) Per section 4.28(E)(3)(a.3) of the Land Use Code, an 80-foot buffer is required between this Industrial zoned property and the adjacent Low Density Mixed -Use Neighborhood to the east. This project provides for an 80-foot strip of property free of buildings and parking, but seeks a modification of this standard to provide additional landscape screening. Section 2.8.2(H)(1) of the Land Use Code allows for such a modification of the standard when the submitted application promotes the purposes of the code and equally meets the provisions of the modified standard. The existing Evergreen West pond and surrounding vegetation create a visual screen that exceeds the requirements of the 80- foot buffer. 2) Per section 4.28(E)(3)(a.2) of the Land Use Code, a 30-foot district boundary buffer is required between Industrial zoned property and the CN Commercial property west of Blue Spruce Drive. Section 4.28(E)(2)(b) of the Land Use Code then requires that 30% of the building frontage abut to this buffer. This project seeks a modification of these standards to waive the requirement of the district buffer and to waive the requirement of positioning the building to abut this buffer. Per section 2.8.2(H)(1) of the Land Use Code, a modification of these standards may be granted where the submitted plan promotes the general purpose of the standard. The standards for district buffers are in effect to visually screen differing land uses, in this case, industrial and commercial uses. While zoned commercially, the neighboring lot has been developed industrially, both in use and visual character of the development. The vertical structure is a concrete and metal building with a small Kaufman & Robinson Office Development, Project Development Plan, #40-08 December 2, 2009 Administrative Hearing Page 7 of the building frontage. The applicant is proposing to provide a parking lot containing 9 spaces between the front of the building and Blue Spruce Drive. The distance between the front of the building and the property line would be 80' and the 30' deep landscaped yard would not be included. The applicant has submitted a request for a modification of this standard. • The standard located in Subsection 4.28(E)(3)(a)2, which requires a minimum 30' deep landscaped yard be provided on the subject property along the street right-of-way (ROW) for Blue Spruce Drive. The plan as submitted contains a parking lot with 9 spaces between the building and the ROW. The applicant has submitted a request for a modification of this standard. • The standard located in Subsection 4.28(E)(3)(a)3, which requires a minimum 80' deep landscaped yard be provided along any boundary line that adjoins a zone district that is predominantly characterized by permitted residential uses. The undeveloped property directly east is in the LMN, Low Density Mixed -Use Residential District. The plan as submitted does not fully satisfy this section of the LUC. The applicant has submitted a request for a modification of this standard. As specified in Section 2.8.2 Modification Review Procedures, (H) (Standards), the Planning and Zoning Board may grant a modification of standards only if it finds that the granting of the modification would not be detrimental to the public good, and that: (1) the plan as submitted will promote the general purpose of the standard for which the modification is requested equally well or better than would a plan which complies with the standard for which a modification is requested, or (2) the granting of a modification from the strict application of any standard would, without impairing the intent and purpose of this Land Use Code, substantially alleviate an existing, defined and described problem of city-wide concern or would result in a substantial benefit to the city by reason of the fact that the proposed project would substantially address an important community need specifically and expressly defined and described in the City's Comprehensive Plan or in an adopted policy, ordinance or resolution of the City Council, and the strict application of such a standard would render the project practically infeasible; or (3) by reason of exceptional physical conditions or other extraordinary and exceptional situations, unique to such property, including, but not limited to, physical conditions such as exceptional narrowness, shallowness or topography, or physical conditions which hinder the owner's ability to install a solar energy Kaufman & Robinson Office Development, Project Development Plan, #40-08 December 2, 2009 Administrative Hearing Page 6 D. Division 3.6 - Transportation and Circulation Section 3.6.4. Transportation Level of Service Requirements The City of Fort Collins Traffic Engineer and Transportation Planning Department have determined that, based on the information provided in the Transportation Impact Study, the proposal satisfies the requirements for Transportation Level of Service standards for development. 4. ARTICLE 4 - DISTRICTS A. Division 4.28 - Industrial District Offices and light industrial uses are permitted in the I - Industrial District, subject to an administrative (Type 1) review. The I District is: Intended to provide a location for a variety of work processes and work places such as manufacturing and distributing, indoor and outdoor storage, and a wide range of commercial and industrial operations. The Industrial District also accommodates complementary and supporting uses such as convenience shopping, child care centers and housing. While these Districts will be linked to the city's transportation system for multiple modes of travel, some may emphasize efficient commercial trucking and rail traffic as needed. Industrial and manufacturing processes used in this District may, by necessity, be characteristically incompatible with residential uses. This proposal complies with the purpose of the I District as it is a small infill development project that provides light industrial and office uses on a property that is surrounded by primarily developed properties containing industrial, commercial, and office uses, with residential uses in close proximity to the northeast and southeast. Section 4.28(D) Land Use Standards The proposal satisfies the applicable land use standards in the I - Industrial District. Section 4.28(E) Development Standards The proposal satisfies applicable development standards in the I - Industrial District, with the following exceptions: • The standard located in Subsection 4.28(E)(2)(b) — Orientation, which requires that a building face abut the required minimum landscaped yard for at least 30% Kaufman & Robinson Office Development, Project Development Plan, #40-08 December 2, 2009 Administrative Hearing j Page 5 1 for direct connections to major pedestrian and bicycle destinations, including the existing neighborhood park to the east and the shopping center to the west of the development. Required number of parking spaces. Section 3.2.2(K)(2)(a) sets forth maximum parking allowances for non-residential land uses. The development proposal does not exceed the parking allowance set forth in the LUC for the non- residential uses (light industrial and office) in this project. B. Division 3.3 - Engineering Standards Section 3.3.1. Plat Standards The proposal complies with the general plat requirements as set forth in this section. Section 3.3.5. Engineering Design Standards The project complies with all design standards, requirements and specifications for services as stated in this section of the LUC. C. Division 3.5 — Building Standards Section 3.5.1(B). Architectural Character The building will be compatible with the established architectural character of the surrounding area, being industrial/commercial/office. Section 3.5.1(C). Building Size, Height, Bulk, Mass, Scale The building is proposed to be one story and 22' in height, with a flat roof. It will be a long, linear structure very similar to the existing buildings to the north and south. Section 3.5.1(E). Materials The building materials will be predominantly metal on the north, south, and east sides. The front side facing Blue Spruce Drive, to the west, will be a combination of concrete panels, metal & ivy "green screens", and stone veneer at the entry. The materials are very similar to the existing materials already used in the surrounding area. Kaufman & Robinson Office Development, Project December 2, 2009 Administrative Hearing Page 4 Transportation and Circulation. Further discussions of these follow. A. Division 3.2 - Site Planning and Design Standards Section 3.2.1. Landscaping and Tree Protection The proposal satisfies the applicable Landscaping and Tree including the following: Section 3.2.1(D)(2). Street trees. Plan, #40-08 rticular standards n standards, The proposed street tree planting is in accordance with Section '3.2.1(D)(2)(b), providing trees at 30' on -center in an area behind attached sidewalk or at 25' on -center in a parkway between curb and detached sidewalk along Blue Spruce Drive. Section 3.2.1(E)(4). Parking Lot Perimeter Landscaping The proposal satisfies the parking lot perimeter landscaping requirements set forth in Sections 3.2.1(E)(4)(a) & (b), providing a combination of deciduous shrubs and trees in a planting area between the parking lot and Blue Spruce Drive and in a planting area between the parking lot and the south property line. Section 3.2.1(E)(5). Parking Lot Interior Landscaping The proposal satisfies the requirement set forth in Section 3.2.1(E)(5) pertaining to 6% of the interior space of a parking lot with less than 100 spaces shall be landscape areas. There is 6.1 % interior landscaping being provided. Section 3.2.2. Access, Circulation and Parking The proposal satisfies the applicable Access, Circulation and Parking standards, including the following: Bicycle Facilities. The development proposal satisfies the standard set forth in Section 3.2.2(C)(4)(a) in that a rack for 2 bicycles is being provided next to the main entry of the building. This exceeds the minimum of 1 bicycle parking space required as 5% of the total vehicle parking spaces on -site. I Direct On -site Access to Pedestrian and Bicycle Destinations. The development proposal satisfies the standard set forth in Section 3.2.2(C)(6) in that the on -site pedestrian and bicycle circulation system is designed to provide i Kaufman & Robinson Office Development, Project Development Plan, #40-08 December 2, 2009 Administrative Hearing Page 3 This proposal complies with the purpose of the I District as it is a small infill development project that provides light industrial and office uses on a property that is surrounded by primarily developed properties containing industrial, commercial, and office uses, with residential uses in close proximity to the northeast and southeast. COMMENTS: 1. Background: The surrounding zoning and land uses are as follows N: I; existing industrial, commercial S: I; existing industrial, commercial E: LMN; existing pond & wetland, undeveloped W: CS; existing industrial, commercial i The property was annexed into the City as part of the Pine Tree Park Annexation in November, 1972. i The property was subdivided as Lots 3 & 4, Block 5 of Evergreen Park Subdivision in 1973. The property remained as Lots 3 & 4, Block 5 with Replat (No. 1) of Evergreen Park Subdivision in March, 1974. 2. ARTICLE 2 - ADMINISTRATION Section 2.2.2. Step 2: Neighborhood Meetings The proposed development is for light industrial and office uses! which are permitted in the I - Industrial District subject to an administrative (Type 1) review and public hearing. The LUC does not require that a neighborhood meeting be heldlfor development proposals that are subject to an administrative review and none was held for this development proposal. i 3. ARTICLE 3 - GENERAL DEVELOPMENT STANDARDS The Kaufman & Robinson Office Development, PDP proposal meets the applicable standards in ARTICLE 3 - GENERAL DEVELOPMENT STANDARDS of the LUC. Of specific note are Division 3.2 - Site Planning and Design Standards; Division 3.3 - Engineering Standards; Division 3.5 - Building Standards; and, Division 3.6 - I Kaufman & Robinson Office Development, Project Development Plan, #40-08 December 2, 2009 Administrative Hearing Page 2 I and, Division 3.6 - Transportation and Circulation of ARTICLE 3 - GENERAL DEVELOPMENT STANDARDS; • and applicable district standards located in Division 4.28 Industrial District of ARTICLE 4 - DISTRICTS. The Kaufman & Robinson Office Development, PDP proposal does not comply with, and requires modifications of, three (3) standards set forth in ARTICLE 4 - DISTRICTS, Division 4.28 Industrial District, Section 4.28(E) Development Standards of the LUC. The standards are located in Subsection 4.28(E)(2)(b) under Building Design, and Subsections 4.28(E)(3)(a)2 and 4.28(E)(3)(a)3 under Site Design, as follows: • The standard located in Subsection 4.28(E)(2)(b) — Orientation, which requires that a building face abut the required minimum landscaped yard for at least 30% of the building frontage. The applicant has submitted a request for a modification of this standard. • The standard located in Subsection 4.28(E)(3)(a)2, which requires a minimum 30' deep landscaped yard be provided on the subject property along the street right-of-way for Blue Spruce Drive. The applicant has submitted a request for a modification of this standard. • The standard located in Subsection 4.28(E)(3)(a)3, which requires a minimum 80' deep landscaped yard be provided along any boundary line that adjoins a zone district that is predominantly characterized by permitted residential uses. The undeveloped property directly east is in the LMN, Low Density Mixed -Use Residential District. The applicant has submitted a request for a modification of this standard. Offices and light industrial uses are permitted in the I - Industrial. District, subject to an administrative (Type 1) review. The I District is: Intended to provide a location for a variety of work processes and work places such as manufacturing and distributing, indoor and outdoor storage, and a wide range of commercial and industrial operations. The Industrial District also accommodates complementary and supporting uses such as convenience shopping, child care centers and housing. While these Districts will be linked to the city's transportation system for multiple modes of travel, some may emphasize efficient commercial trucking and rail traffic as needed. Industrial and manufacturing processes used in this District may, by necessity, be characteristically incompatible with residential uses. of F�co�rt` Collins ITEM NO y MEETING DATE STAFF 't✓ HEARING OFFICER PROJECT: Kaufman & Robinson Office Development, Project Development Plan (PDP) - #40-08 APPLICANT: BASIS Architecture c/o Matthew Heiser 1692 Big Thompson Avenue Estes Park, CO. 80517 OWNERSHIP: Kaufman & Robinson, Inc. 1306 Blue Spruce Drive, Suite A Fort Collins, CO. 80524 PROJECT DESCRIPTION: This is a request for a technology -based design and manufacturing company that is in a growth mode. This is a 2-phase development on 1.76 acres. Phase 1, fronting on Blue Spruce Drive, will consist of 9,500 square feet of General Office & Small Industry uses in a single -story metal building not to exceed 22 feet in height. Phase 2 will be a 4,875 square foot addition to the rear of the building for Small & Light Industrial uses. A total of 22 on -site parking spaces are being provided. The company will employ between 12 and 30 people. The subject properties are on the east side of Blue Spruce Drive, essentially at the intersection with Red Cedar Circle, and are zoned I - Industrial. They are Lots 3 & 4, Block 5 of Evergreen Park and are addressed as 1324 & 1330 Blue Spruce Drive. RECOMMENDATION: Approval EXECUTIVE SUMMARY: The Kaufman & Robinson Office Development, PDP proposal complies with applicable requirements of the Land Use Code (LUC), more specifically: • the process located in Division 2.2 - Common Development Review Procedures for Development Applications of ARTICLE 2 - ADMINISTRATION; • Standards located in Division 3.2 - Site Planning and Design Standards; Division 3.3 - Engineering Standards; Division 3.5 — Building Standards, Current Planning 281 N College Av PO Box 580 Fort Collins, CO 80522-0580 fcgov.com/currentplanning 970.221.6750